Search NASA⌕ Search

SEARCH · Search NASA

Results for “Indoor simulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

238 records · Page 14

Global Air Quality and Health Co-benefits of Mitigating Near-term Climate Change Through Methane and Black Carbon Emission Controls

Tropospheric ozone and black carbon (BC), a component of fine particulate matter (PM < or = 2.5 microns in aerodynamic diameter; PM2.5), are associated with premature mortality and they disrupt global and regional climate. Objectives: We examined the air quality and health benefits of 14 specific emission control measures targeting BC and methane, an ozone precursor, that were selected because of their potential to reduce the rate of climate change over the next 20-40 years. Methods: We simulated the impacts of mitigation measures on outdoor concentrations of PM2.5 and ozone using two composition-climate models, and calculated associated changes in premature PM2.5‑ and ozone-related deaths using epidemiologically derived concentration-response functions. Results: We estimated that, for PM2.5 and ozone, respectively, fully implementing these measures could reduce global population-weighted average surface concentrations by 23-34% and 7-17% and avoid 0.6-4.4 and 0.04-0.52 million annual premature deaths globally in 2030. More than 80% of the health benefits are estimated to occur in Asia. We estimated that BC mitigation measures would achieve approximately 98% of the deaths that would be avoided if all BC and methane mitigation measures were implemented, due to reduced BC and associated reductions of nonmethane ozone precursor and organic carbon emissions as well as stronger mortality relationships for PM2.5 relative to ozone. Although subject to large uncertainty, these estimates and conclusions are not strongly dependent on assumptions for the concentration-response function. Conclusions: In addition to climate benefits, our findings indicate that the methane and BC emission control measures would have substantial co-benefits for air quality and public health worldwide, potentially reversing trends of increasing air pollution concentrations and mortality in Africa and South, West, and Central Asia. These projected benefits are independent of carbon dioxide mitigation measures. Benefits of BC measures are underestimated because we did not account for benefits from reduced indoor exposures and because outdoor exposure estimates were limited by model spatial resolution.

air quality↗

Technical Background and Validation Report on the Residential Water Inhalation Risk Calculator Presented in the Risk Assessment Information System

Indoor air quality (IAQ) is critical for human health. Poor IAQ is linked to respiratory issues, cardiovascular diseases, and cancer. Indoor pollutants are emitted by typical household items such as cleaning products, personal care items, building materials, and tap water - an understudied volatile organic compound (VOC) source. This document presents the Residential Water Inhalation Risk Calculator (RWIRC), which estimates daily VOC exposure concentrations from various household water uses, such as showering and dishwashing, to assess exposure risks for the most vulnerable occupant. Integrated into the Risk Assessment Information System (RAIS) and sponsored by the US Department of Energy (DOE), the calculator divides a house into three compartments: shower, bathroom, and other spaces, accounting for daily water usage patterns and calculating VOC concentrations. Exposure data generated using the calculator can assist health assessors in estimating excess lifetime cancer risk (ELCR) and hazard index (HI) from VOC inhalation. Unlike traditional exposure models that utilize Andelman’s constant, the RWIRC continuously assesses variability in VOC concentrations and environmental conditions using differential equations to track VOC concentrations and air exchange between compartments. The calculator also provides unique volatilization fractions for each chemical and appliance, enhancing accuracy of the exposure concentration estimation. The RWIRC is accessible online and allows users to customize parameters (i.e., number of bathrooms, water temperature, and exhaust fan conditions) and input VOC characteristics (i.e., tap water and ambient air concentrations). This document provides a step-by-step guide on implementing the calculator. It also provides comparisons with the ATSDR-SHOWER calculator, using eight VOCs with varying physicochemical properties to reveal differences in algorithms and output concentrations. Simulations also assess how bathroom door positions and exhaust fan usage affect VOC exposure. The calculator results can enhance EPA risk screening levels for inhalation exposure to VOCs from tap water, offering a sophisticated tool for assessing inhalation risks and improving public health protection.

54 ENVIRONMENTAL SCIENCES↗

Intercomparison of Aerosol Instrumental Responses Using AEROTRAK, SMPS, and APS in a Simulated Building

In this work, three aerosol instruments were intercompared by using data collected from field campaigns in a simulated building environment during the last quarter of 2020 from October to December at Oak Ridge National Laboratory. The three aerosol instruments—AeroTrak Model 9110, Scanning Mobility Particle Spectrometer (SMPS) 3080L + 3025A, and Aerodynamic Particle Sizer (APS) 3320—were manufactured by TSI Inc. to perform in situ measurements of particle number concentration in the air. These instruments were co-located in one room in which an aerosol generator was used to produce a defined aerosol population for the instruments to sample and detect in each campaign. The SMPS measured aerosol particles with diameters from 0.01 to 0.7 µm, APS measured aerosol particles with diameters from 0.5 to 20 µm, and AeroTrak measured aerosol particles with diameters from 0.1 to 10 µm. The results suggest that although AeroTrak is fast and easy to use, it does not provide measurements comparable with those obtained by SMPS and APS. The differences in particle counts were orders of magnitude in size (i.e., the AeroTrak data were unreasonably small in the tested scenarios). The results clearly indicate that AeroTrak should not be used in ambient applications in which the level of particle concentration is expected to be high. This would cause difficulty to a campaign in which the dilution factor is unknow a priori. The high particle concentration could also lead to an erroneous aerosol size distribution (e.g., a bimodal size distribution was measured as opposed to a single-mode one). The number concentration limit that AeroTrak is expected to run reliably (i.e., with a counting coincidence error less than ±10%) is approximately three to four per cubic centimeter. This suggests that the instrument is best used in a clean room environment, not in an ambient or indoor application, such as the Flexible Research Platform campaigns.

47 OTHER INSTRUMENTATION↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗