Search NASA⌕ Search

SEARCH · Search NASA

Results for “Injections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The effects of gas-fluid-rock interactions on CO2 injection and storage: Insights from reactive transport modeling

Possible means of reducing atmospheric CO{sub 2} emissions include injecting CO{sub 2} in petroleum reservoirs for Enhanced Oil Recovery or storing CO{sub 2} in deep saline aquifers. Large-scale injection of CO{sub 2} into subsurface reservoirs would induce a complex interplay of multiphase flow, capillary trapping, dissolution, diffusion, convection, and chemical reactions that may have significant impacts on both short-term injection performance and long-term fate of CO{sub 2} storage. Reactive Transport Modeling is a promising approach that can be used to predict the spatial and temporal evolution of injected CO{sub 2} and associated gas-fluid-rock interactions. This presentation will summarize recent advances in reactive transport modeling of CO{sub 2} storage and review key technical issues on (1) the short- and long-term behavior of injected CO{sub 2} in geological formations; (2) the role of reservoir mineral heterogeneity on injection performance and storage security; (3) the effect of gas mixtures (e.g., H{sub 2}S and SO{sub 2}) on CO{sub 2} storage; and (4) the physical and chemical processes during potential leakage of CO{sub 2} from the primary storage reservoir. Simulation results suggest that CO{sub 2} trapping capacity, rate, and impact on reservoir rocks depend on primary mineral composition and injecting gas mixtures. For example, models predict that the injection of CO{sub 2} alone or co-injection with H{sub 2}S in both sandstone and carbonate reservoirs lead to acidified zones and mineral dissolution adjacent to the injection well, and carbonate precipitation and mineral trapping away from the well. Co-injection of CO{sub 2} with H{sub 2}S and in particular with SO{sub 2} causes greater formation alteration and complex sulfur mineral (alunite, anhydrite, and pyrite) trapping, sometimes at a much faster rate than previously thought. The results from Reactive Transport Modeling provide valuable insights for analyzing and assessing the dynamic behaviors of injected CO{sub 2}, identifying and characterizing potential storage sites, and managing injection performance and reducing costs.

54 ENVIRONMENTAL SCIENCES↗

Simulation of carbon dioxide injection at the FutureGen2.0 site: Class VI permit model and local sensitivity analysis

Numerical simulation was conducted to evaluate supercritical CO 2 (scCO 2 ) storage in the Mt. Simon sandstone at the FutureGen 2.0 site in Morgan County, Illinois. The simulations illustrate the recent modeling effort conducted to successfully obtain a Class VI permit under the Underground Injection Control Program of the U.S. Environmental Protection Agency. The scCO2 was injected into a highly stratified reservoir, distributed among four lateral wells. Results show that each of the multiple reservoir layers with low permeability traps a fraction of the scCO 2 beneath it so that the injected scCO 2 does not reach the top of the reservoir by the end of the simulation period. Hence, all of the injected scCO 2 is considered to be safely trapped by the stratified structure within the reservoir. A local sensitivity analysis (LSA) was conducted for injectivity and plume size at the end of the 20 year injection period. The LSA indicates that the imposed initial conditions and the hydraulic properties of the injection layer contribute the most to the sensitivity. Overall, the simulation outputs are very sensitive to only a small fraction of the inputs. However, the parameters that are important for controlling CO 2 injectivity are not the same as those controlling the plume area. The three most sensitive inputs for injectivity are the horizontal permeability and the residual aqueous saturation of the injection layer, and the initial fracture-pressure gradient. For the plume area, the most sensitive inputs are the horizontal permeability of the injection layer and the residual aqueous saturation of the two adjacent layers above the injection layer. Furthermore, the advantages of requiring just a single set of simulation results, scalability to the proper parameter errors, and straightforward calculation of the composite sensitivities make the proposed analysis attractive for guiding site characterization, injection well design, estimating AoR uncertainty and, and monitoring network design.

54 ENVIRONMENTAL SCIENCES↗

First Ever Polymer Flood Field Pilot to Enhance the Recovery of Heavy Oils on Alaska’s North Slope – Polymer Injection Performance

Alaska North Slope (ANS) holds an estimated 20-30+ billion barrel heavy oil resources, yet the development pace has been very slow due to high development costs and low oil recovery using conventional waterflood and EOR methods. The objective of this pilot is to perform a field experiment to validate the use of an advanced polymer flooding technology to unlock the vast heavy oil resources on ANS. The advanced polymer flooding technology combines polymer flooding, low salinity water flooding, horizontal wells, and if necessary, injection conformance control treatments into one integrated process to significantly improve oil recovery from heavy oil reservoirs. Two pairs of horizontal injection and production wells have been deployed in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field to conduct a polymer flood pilot. The pilot will acquire scientific knowledge and field performance data to optimize polymer flood design in the Schrader Bluff heavy oil reservoirs on ANS. Polymer injection started on August 28, 2018 using a custom made polymer blending and pumping unit. This paper focuses on the facility setup and polymer injection performance into the horizontal injectors drilled and completed in the Schrader Bluff heavy oil reservoir. Partially hydrolyzed polyacrylamide (HPAM) polymer was selected and the initial target viscosity was set at 45 centipoise. Polymer injection rate was set at 2200 bbl/day for one injector (J-23A) and 1200 bbl/day for the other (J-24A) based on production voidage. Injection pressure was controlled at below fracture pressure to prevent fracturing the reservoir and causing fast breakthroughs. Step rate and pressure falloff tests indicate that short term polymer injectivity is similar to water injectivity, which means that injectivity is mostly controlled by fluid mobility deep in the reservoir rather than that in the vicinity of the injection wellbore. Long term injection data indicate that polymer injectivity has been decreasing in both injectors as the reservoir is filled by polymer. No polymer has been observed in the production stream 7 months after the start of polymer injection compared with a 3-month breakthrough time with waterflood. This indicates that polymer significantly delays breakthrough time which will lead to increased sweep efficiency.

Ning, Samson↗

Characterization and Alteration of Wettability States of Alaskan Reserviors to Improve Oil Recovery Efficiency (including the within-scope expansion based on Cyclic Water Injection - a pulsed waterflood for Enhanced Oil Recovery)

Numerous early reports on experimental works relating to the role of wettability in various aspects of oil recovery have been published. Early examples of laboratory waterfloods show oil recovery increasing with increasing water-wetness. This result is consistent with the intuitive notion that strong wetting preference of the rock for water and associated strong capillary-imbibition forces gives the most efficient oil displacement. This report examines the effect of wettability on waterflooding and gasflooding processes respectively. Waterflood oil recoveries were examined for the dual cases of uniform and non-uniform wetting conditions. Based on the results of the literature review on effect of wettability and oil recovery, coreflooding experiments were designed to examine the effect of changing water chemistry (salinity) on residual oil saturation. Numerous corefloods were conducted on reservoir rock material from representative formations on the Alaska North Slope (ANS). The corefloods consisted of injecting water (reservoir water and ultra low-salinity ANS lake water) of different salinities in secondary as well as tertiary mode. Additionally, complete reservoir condition corefloods were also conducted using live oil. In all the tests, wettability indices, residual oil saturation, and oil recovery were measured. All results consistently lead to one conclusion; that is, a decrease in injection water salinity causes a reduction in residual oil saturation and a slight increase in water-wetness, both of which are comparable with literature observations. These observations have an intuitive appeal in that water easily imbibes into the core and displaces oil. Therefore, low-salinity waterfloods have the potential for improved oil recovery in the secondary recovery process, and ultra low-salinity ANS lake water is an attractive source of injection water or a source for diluting the high-salinity reservoir water. As part of the within-scope expansion of this project, cyclic water injection tests using high as well as low salinity were also conducted on several representative ANS core samples. These results indicate that less pore volume of water is required to recover the same amount of oil as compared with continuous water injection. Additionally, in cyclic water injection, oil is produced even during the idle time of water injection. It is understood that the injected brine front spreads/smears through the pores and displaces oil out uniformly rather than viscous fingering. The overall benefits of this project include increased oil production from existing Alaskan reservoirs. This conclusion is based on the performed experiments and results obtained on low-salinity water injection (including ANS lake water), vis-a-vis slightly altering the wetting conditions. Similarly, encouraging cyclic water-injection test results indicate that this method can help achieve residual oil saturation earlier than continuous water injection. If proved in field, this would be of great use, as more oil can be recovered through cyclic water injection for the same amount of water injected.

02 PETROLEUM↗

Multiturn injection of EBIS ions in booster

Ions from EBIS are injected into Booster after acceleration by an RFQ and a Linac. The velocity of the ions at Booster injection is c{beta} where c is the velocity of light and (1) {beta} = 0.0655. The kinetic energy is (2) W = mc{sup 2}({gamma}-1) where m is the ion mass and (3) {gamma} = (1-{beta}{sup 2}){sup -1/2}. Putting in numbers one gets a kinetic energy of approximately 2 MeV per nucleon for each ion. The revolution period at injection is 10.276 {micro}s. The ions in the EBIS trap are delivered in a beam pulse that ranges from 10 to 40 {micro}s in length. This amounts to 1 to 4 turns around the machine. The transverse emittance (un-normalized) of EBIS beams just prior to injection into Booster is 11{pi} mm milliradians in both planes. This is an order of magnitude larger than the nominal 1{pi} mm milliradians for Tandem beams. Injection proceeds by means of an electrostatic inflector in the C3 straight section and four programmable injection dipoles in the C1, C3, C7, and D1 straights. These devices have been in use for many years for the injection of ions from Tandem as described in [1] and [2]. The inflector brings the incoming beam to the edge of the Booster acceptance and the dipoles produce a closed orbit bump that initially places the closed orbit near the septum at the in ector exit. During injection the orbit bump must be collapsed at a rate that keeps the injected beam from hitting the septum while continuing to allow beam to be injected into the machine acceptance. The process is discussed in [2] and [3]. There it is assumed that the injected beam moves with the closed orbit as the bump collapses. In the present report this is shown to be a valid approximation if the bump collapses sufficiently slowly. It is also shown that by judiciously choosing the horizontal tune and the initial distance of the closed orbit from the septum one can inject up to 4 turns of EBIS beams without loss on the septum. The reason for wanting to inject over a period of 4 rather than fewer turns is that this allows the beam to be distributed over a larger area of the Booster acceptance, thereby reducing the space charge force on the beam particles.

43 PARTICLE ACCELERATORS↗

Effect of post injections on mixture preparation and unburned hydrocarbon emissions in a heavy-duty diesel engine

This work explores the mechanisms by which a post injection can reduce unburned hydrocarbon (UHC) emissions in heavy-duty diesel engines operating at low-temperature combustion conditions. Post injections, small, close-coupled injections of fuel after the main injection, have been shown to reduce UHC in the authors’ previous work. In this work, we analyze optical data from laser-induced fluorescence of both CH 2 O and OH and use chemical reactor modeling to better understand the mechanism by which post injections reduce UHC emissions. The results indicate that post-injection efficacy, or the extent to which a post injection reduces UHC emissions, is a strong function of the cylinder pressure variation during the post injection. However, the data and analysis indicate that the pressure and temperature rise from the post injection combustion cannot solely explain the UHC reduction measured by both engine-out and optical diagnostics. In conclusion, the fluid-mechanic, thermal, and chemical interaction of the post injection with the main-injection mixture is a key part of UHC reduction; the starting action of the post jet and the subsequent entrainment of surrounding gases are likely both important processes in reducing UHC with a post injection.

33 ADVANCED PROPULSION SYSTEMS↗

Maximization of ICRF power by SOL density tailoring with local gas injection

We report that experiments have been performed under the coordination of the International Tokamak Physics Activity (ITPA) on several tokamaks, including ASDEX Upgrade (AUG), JET and DIII-D, to characterize the increased Ion cyclotron range of frequency (ICRF) antenna loading achieved by optimizing the position of gas injection relative to the RF antennas. On DIII-D, AUG and JET (with the ITER-Like Wall) a 50% increase in the antenna loading was observed when injecting deuterium in ELMy H-mode plasmas using mid-plane inlets close to the powered antennas instead of divertor injection and, with smaller improvement when using gas inlets located at the top of the machine. The gas injection rate required for such improvements (similar to 0.7 x 10(22) el s(-1) in AUG, similar to 1.0 x 10(22) el s(-1) in JET) is compatible with the use of this technique to optimize ICRF heating during the development of plasma scenarios and no degradation of confinement was observed when using the mid-plane or top inlets compared with divertor valves. An increase in the scrape-off layer (SOL) density was measured when switching gas injection from divertor to outer mid-plane or top. On JET and DIII-D, the measured SOL density increase when using main chamber puffing is consistent with the antenna coupling resistance increase provided that the distance between the measurement lines of sight and the injection location is taken into account. Optimized gas injection was also found to be beneficial for reducing tungsten (W) sputtering at the AUG antenna limiters, and also to reduce slightly the W and nickel (Ni) content in JET plasmas. Modeling the specific effects of divertor/top/mid-plane injection on the outer mid-plane density was carried out using both the EDGE2D-EIRENE and EMC3-EIRENE plasma boundary code packages; simulations indeed indicate that outer mid-plane gas injection maximizes the density in the mid-plane close to the injection point with qualitative agreement with the AUG SOL density measurements for EMC3-EIRENE. Field line tracing for ITER in the 15 MA Q(DT) = 10 reference scenario indicates that the planned gas injection system could be used to tailor the density in front the antennas. Lastly, benchmarking of EMC3-EIRENE against AUG and JET data is planned as a first step towards the ITER SOL modelling required to quantify the effect of gas injection on the SOL density in front of the antennas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geologic carbon sequestration injection wells in overpressured storage reservoirs: estimating area of review

The Area of Review (AoR) under the US Environmental Protection Agency's (EPA) Class VI CO 2 injection permit is defined as the region surrounding the geologic carbon sequestration (GCS) project where underground sources of drinking water (USDWs) may be endangered. Estimation of the AoR is based on the calculated reservoir pressurization due to CO 2 injection and the associated potential to lift saline water into potable groundwater aquifers through open flow paths (e.g. wells) assuming the system is hydrostatic. In cases where the storage reservoirs are not initially hydrostatic, and in particular where they are overpressured, AoR estimation methods need to be altered. Here in this paper, we present and apply an approach to evaluating potential endangerment of USDW based on comparing brine leakage through a hypothetical open flow path in a no-injection scenario and brine leakage in a CO 2 -injection scenario. We present six possible ways to normalize injection-related leakage relative to no-injection leakage. We calculate leakage using semi-analytical solutions for single-phase flow and model reservoir pressurization and flow up (single) leaky wells located progressively farther from the injection well. For an example case of relative overpressure and using an injection-rate-based approach, results show 50-60% larger open-well-leakage rates for wells located at 2 km and 10% increase for wells located at 10 km from the injection well relative to the no-injection case. If total brine leakage is considered, the results depend strongly on the assumed pre-injection to post-injection time frames and on the methods of normalization used to calculate incremental leakage.

54 ENVIRONMENTAL SCIENCES↗

Wallula Basalt Pilot Demonstration Project: Post-injection Results and Conclusions

Deep underground geologic formations are emerging as a reasonable option for long-term storage of CO 2 , including large continental flood basalt formations. At the GHGT-11 and GHGT-12 conferences, progress was reported on the initial phases for Wallula Basalt Pilot demonstration test (located in Eastern Washington state), where nearly 1,000 metric tons of CO 2 were injected over a 3-week period during July/August 2013. The target CO 2 injection intervals were two permeable basalt interflow reservoir zones with a combined thickness of ~20 m that occur within a layered basalt sequence between a depth of 830-890 m below ground surface. During the two-year post-injection period, downhole fluid samples were periodically collected during this post-injection monitoring phase, coupled with limited wireline borehole logging surveys that provided indirect evidence of on-going chemical geochemical reactions/alterations and CO 2 disposition. A final detailed post-closure field characterization program that included downhole fluid sampling, and performance of hydrologic tests and wireline geophysical surveys. Included as part of the final wireline characterization activities was the retrieval of side-wall cores from within the targeted injection zones. These cores were examined for evidence of in-situ mineral carbonization. Visual observations of the core material identified small globular nodules, translucent to yellow in color, residing within vugs and small cavities of the recovered basalt side-wall cores, which were not evident in pre-injection side-wall cores obtained from the native basalt formation. Characterization by x-ray diffraction identified these nodular precipitates as ankerite, a commonly occurring iron and calcium rich carbonate. Isotopic characterization (δ 13 C, δ 18 O) conducted on the ankerite nodules indicate a distinct isotopic signature that is closely aligned with that of the injected CO 2 . Both the secondary mineral nodules and injected CO 2 are measurably different from the isotopic content of basalt, injection zone groundwater and for naturally occurring calcite. Final post-injection wireline geophysical logging results also indicate the presence of free-phase CO 2 at the top of the two injection interflow zones, with no vertical migration of CO 2 above the injection horizons. Furthermore, these findings are significant and demonstrate the feasibility of sequestering CO 2 in a basalt formation.

54 ENVIRONMENTAL SCIENCES↗

Central Appalachian Basin Unconventional (Coal/Organic Shale) Reservoir Small Scale CO 2 Injection Test

The Virginia Center for Coal and Energy Research (VCCER) project, “Injecting Carbon Dioxide into Unconventional Storage Reservoirs in the Central Appalachian Basin, with an Emphasis on Enhanced Coalbed Methane Recovery (ECBM), to Validate Prior Geological Characterization,” successfully completed two unique field projects: (1) a 510 ton scale ‘huff-and-puff’ carbon dioxide (CO 2 ) injection into a legacy horizontal Chattanooga Shale well in Morgan County, Tennessee and (2) a 13,263 ton CO 2 injection into 3 legacy coalbed methane (CBM) wells in Buchanan County, Virginia. The results from this Morgan County shale injection test confirm the injectivity and storage potential of CO 2 in organic shales formations while enhancing gas recovery. During the flowback phase, gas composition and flow rate were frequently monitored. Results indicated that there was a significant increase in gas flow rate during the first five months of the flowback phase and there was also a significant increase in gas quality, such that the percent composition of NGLs (natural gas liquids), including ethane, propane, and butane, increased. The primary objective of the research is to test the injectivity of CO 2 into unmineable coal seams and the potential for enhanced coalbed methane recovery (ECBM) by stressing the coals under continuous injection for a one-year period. The results from the Buchanan County ECBM test provided data to better understand the effect of matrix swelling, due to the adsorption of CO 2 on the coal surface, on injectivity and ECBM. During the greater than 13,000-ton injection, injectivity was maintained and coal swelling reduced by injecting into multiple wells at a moderate injection rate. Flowback has recently commenced and will be instrumental in determining the ECBM potential of central Appalachian coals and identifying commercialization opportunities.

03 NATURAL GAS↗

Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During the time that enhanced AC was injected, the average mercury removal for the month long test was approximately 74% across the test baghouse module. ACI was interrupted frequently during the month long test because the test baghouse module was bypassed frequently to relieve differential pressure. The high air-to-cloth ratio of operations at this unit results in significant differential pressure, and thus there was little operating margin before encountering differential pressure limits, especially at high loads. This limited the use of sorbent injection as the added material contributes to the overall differential pressure. This finding limits sustainable injection of AC without appropriate modifications to the plant or its operations. Handling and storage issues were observed for the TOXECON ash-AC mixture. Malfunctioning equipment led to baghouse dust hopper plugging, and storage of the stagnant material at flue gas temperatures resulted in self-heating and ignition of the AC in the ash. In the hoppers that worked properly, no such problems were reported. Economics of mercury control at Big Brown were estimated for as-tested scenarios and scenarios incorporating changes to allow sustainable operation. This project was funded under the U.S. Department of Energy National Energy Technology Laboratory project entitled 'Large-Scale Mercury Control Technology Field Testing Program--Phase II'.

01 COAL, LIGNITE, AND PEAT↗

Effect of Split-Injection Strategies on Engine Performance and Emissions under Cold-Start Operation

The recently concluded partnership for advancing combustion engines (PACE) was a US Department of Energy consortium involving multiple national laboratories focused on addressing key efficiency and emission barriers in light-duty engines. Generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior was a major pillar in this program. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon, and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster three-way catalyst light-off, and engine out emissions during that period. In this study, engine performance, emissions, and catalyst warmup potential were monitored while the engine was operated using a single direct injection (baseline case) as well as a two-way-equal-split direct injection strategy. These injection strategies were analyzed at a range of cold-start-operation relevant retarded spark timings of up to 25 degrees after top dead center of firing (dATDCf). A stoichiometric 2-bar NIMEP steady-state condition was used for all cases to simulate cold-start operation. Significant improvement in engine stability was observed with the two-way-split injection strategy at the retarded spark timings allowing for up to 2.5x increase in exhaust heat rate when engine operation is stability constrained. Similar fuel-loss-to-oil trends with exhaust heat rate were observed for both single and two-way-split injection strategies. However, the two-way split injection was observed to produce higher NOx emissions per unit exhaust heat rate. A single data point run with three-way-split direct injection at a very retarded spark-timing of 30 dATDCf pointed to further improvements in engine stability and reduction in fuel-loss-to-oil as compared to single injection strategy. Engine stability decreased as spark timing was initially retarded with a single injection but was observed to plateau and stabilize beyond spark timing of 10 dATDCf. Finally, for the two-way-split-injection strategy, retarding the start of injection (SOI) timing of the second injection led to a decrease in engine stability as well as an increase in soot emissions.

42 ENGINEERING↗

Adaptive engine injection for emissions reduction

NOx and soot emissions from internal combustion engines, and in particular compression ignition (diesel) engines, are reduced by varying fuel injection timing, fuel injection pressure, and injected fuel volume between low and greater engine loads. At low loads, fuel is injected during one or more low-pressure injections occurring at low injection pressures between the start of the intake stroke and approximately 40 degrees before top dead center during the compression stroke. At higher loads, similar injections are used early in each combustion cycle, in addition to later injections which preferably occur between about 90 degrees before top dead center during the compression stroke, and about 90 degrees after top dead center during the expansion stroke (and which most preferably begin at or closely adjacent the end of the compression stroke). These later injections have higher injection pressure, and also lower injected fuel volume, than the earlier injections.

33 ADVANCED PROPULSION SYSTEMS↗

Utilizing the Heliophysics/Geospace System Observatory to Understand Particle Injections: Their Scale Sizes and Propagation Directions

The injection region's formation, scale size, and propagation direction have been debated throughout the years, with new questions arising with increased plasma sheet observations by missions like Cluster and THEMIS. How do temporally and spatially smallscale injections relate to the larger injections historically observed at geosynchronous orbit? How to account for opposing propagation directions—earthward, tailward, and azimuthal—observed by different studies? To address these questions, we used a combination of multisatellite and ground–based observations to knit together a cohesive story explaining injection formation, propagation, and differing spatial scales and timescales. We used a case study to put statistics into context. First, fast earthward flows with embedded small–scale dipolarizing flux bundles transport both magnetic flux and energetic particles earthward, resulting in minutes–long injection signatures. Next, a large–scale injection propagates azimuthally and poleward/tailward, observed in situ as enhanced flux and on the ground in the riometer signal. The large–scale dipolarization propagates in a similar direction and speed as the large–scale electron injection. We suggest small–scale injections result from earthward–propagating, small–scale dipolarizing flux bundles, which rapidly contribute to the large–scale dipolarization. We suggest the large–scale dipolarization is the source of the large–scale electron injection region, such that as dipolarization expands, so does the injection. Here, the >90–keV ion flux increased and decreased with the plasma flow, which died at the satellites as global dipolarization engulfed them. We suggest the ion injection region at these energies in the plasma sheet is better organized by the plasma flow.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamics of ionization-induced electron injection in the high density regime of laser wakefield acceleration

The dynamics of ionization-induced electron injection in high density (∼1.2 × 10{sup 19} cm{sup −3}) regime of laser wakefield acceleration is investigated by analyzing the betatron X-ray emission. In such high density operation, the laser normalized vector potential exceeds the injection-thresholds of both ionization-injection and self-injection due to self-focusing. In this regime, direct experimental evidence of early on-set of ionization-induced injection into the plasma wave is given by mapping the X-ray emission zone inside the plasma. Particle-In-Cell simulations show that this early on-set of ionization-induced injection, due to its lower trapping threshold, suppresses the trapping of self-injected electrons. A comparative study of the electron and X-ray properties is performed for both self-injection and ionization-induced injection. An increase of X-ray fluence by at least a factor of two is observed in the case of ionization-induced injection due to increased trapped charge compared to self-injection mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization and evaluation of metal injection molding by using X-ray tomography

6061 aluminum alloy and 316L stainless steel green bodies were obtained by using different injection parameters (injection pressure, speed and temperature). After injection process, the green bodies were scanned by X-ray tomography. The projection and reconstruction images show the different kinds of defects obtained by the improper injection parameters. Then, 3D rendering of the Al alloy green bodies was used to demonstrate the spatial morphology characteristics of the serious defects. Based on the scanned and calculated results, it is convenient to obtain the proper injection parameters for the Al alloy. Then, reasons of the defect formation were discussed. During mold filling, the serious defects mainly formed in the case of low injection temperature and high injection speed. According to the gray value distribution of projection image, a threshold gray value was obtained to evaluate whether the quality of green body can meet the desired standard. The proper injection parameters of 316L stainless steel can be obtained efficiently by using the method of analyzing the Al alloy injection. - Highlights: • Different types of defects in green bodies were scanned by using X-ray tomography. • Reasons of the defect formation were discussed. • Optimization of the injection parameters can be simplified greatly by the way of X-ray tomography. • Evaluation standard of the injection process can be obtained by using the gray value distribution of projection image.

36 MATERIALS SCIENCE↗

Effect of laser parameters on electron injection into laser wakefields in plasma with a counterpropagating additional laser pulse

The interaction of a pump laser pulse with a counterpropagating additional laser pulse and resulting electron injection into the wakefield of the pump pulse in rarefied plasmas is analyzed. The impact of laser parameters on the injected electron number is discussed. When the injection pulse is moderately intense, the injected electron number increases with the injection pulse duration until it reaches some critical value beyond which the injected electron number is saturated. The critical pulse duration is estimated analytically and confirmed by particle-in-cell simulations. When the injection pulse intensity is decreased, the pump pulse intensity should be increased for the injection to occur. In this case, the injection pulse can only slightly affect the wakefield of the pump pulse. The injected electron number can increase with growing injection pulse duration continuously up to some limit that the wakefield can support.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation asymmetries during disruptions on DIII-D caused by massive gas injection

One of the major challenges that the ITER tokamak will have to face during its operations are disruptions. During the last few years, it has been proven that the global consequences of a disruption can be mitigated by the injection of large quantities of impurities. But one aspect that has been difficult to study was the possibility of local effects inside the torus during such injection that could damage a portion of the device despite the global heat losses and generated currents remaining below design parameter. 3D MHD simulations show that there is a potential for large toroidal asymmetries of the radiated power during impurity injection due to the interaction between the particle injection plume and a large n = 1 mode. Another aspect of 3D effects is the potential occurrence of Vertical Displacement Events (VDE), which could induce large poloidal heat load asymmetries. This potential deleterious effect of 3D phenomena has been studied on the DIII-D tokamak, thanks to the implementation of a multi-location massive gas injection (MGI) system as well as new diagnostic capabilities. This study showed the existence of a correlation between the location of the n = 1 mode and the local heat load on the plasma facing components but shows also that this effect is much smaller than anticipated (peaking factor of ∼1.1 vs 3-4 according to the simulations). There seems to be no observable heat load on the first wall of DIII-D at the location of the impurity injection port as well as no significant radiation asymmetries whether one or 2 valves are fired. This study enabled the first attempt of mitigation of a VDE using impurity injection at different poloidal locations. The results showed a more favorable heat deposition when the VDE is mitigated early (right at the onset) by impurity injection. No significant improvement of the heat load mitigation efficiency has been observed for late particle injection whether the injection is done “in the way” of the VDE (upward VDE mitigated by injection from the upper part of the vessel vs the lower part) or not.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗