Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlet diffusers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Pressure activated stability-bypass-control valves to increase the stable airflow range of a Mach 2.5 inlet with 40 percent internal contraction

The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. The inlet stable airflow range provided by various stability-bypass entrance configurations in alternate combination with several stability-bypass exit controls was determined for both steady-state conditions and internal transient pulses. Transient results were also obtained for the inlet with a choke point at the diffuser exit. Instart angles of attack were determined for the various stability-bypass entrance configurations. The response of the inlet-coldpipe system to internal and external oscillating disturbances was determined. Poppet valves at the stability-bypass exit provided an inlet stable airflow range of 28 percent or greater at all static and transient conditions.

Mitchell, G. A.↗

The design and performance of axially symmetrical contoured wall diffusers employing suction boundary layer control

This paper presents a procedure for the design and the performance prediction of axially symmetrical contoured wall diffusers employing suction boundary layer control. An inverse problem approach was used in the potential flow design of the diffuser wall contours. The experimentally observed flow characteristics and the stability of flows within the diffuser are also described. Guidelines for the design of low suction (less than 10 percent of the inlet flow) and thus high effectiveness contoured wall diffusers are also provided based on the results of the experimental program.

Nelson, C. D., Jr.↗

Control of flow separation and mixing by aerodynamic excitation

The recent research progress in the control of shear flows using unsteady aerodynamic excitation conducted at the NASA Lewis Research Center is reviewed. The program is of fundamental nature concentrating on the physics of the unsteady aerodynamic processes. This field of research is a fairly new development with great promise in the areas of enhanced mixing and flow separation control. Enhanced mixing research reported in this paper include influence of core turbulence, forced pairing of coherent structures, and saturation of mixing enhancement. Separation flow control studies included are for a two-dimensional diffuser, conical diffusers, and single airfoils. Ultimate applications of this research include aircraft engine inlet flow control at high angle of attack, wide angle diffusers, highly loaded airfoils as in turbomachinery, and ejector/suppressor nozzles for the supersonic transport. An argument involving the Coanda Effect is made here that all of the above mentioned application areas really only involve forms of shear layer mixing enhancement. The program also includes the development of practical excitation devices which might be used in aircraft applications.

Rice, Edward J.↗

CFD application to subsonic inlet airframe integration

The fluid dynamics of curved diffuser duct flows of military aircraft is discussed. Three-dimensional parabolized Navier-Stokes analysis, and experiment techniques are reviewed. Flow measurements and pressure distributions are shown. Velocity vectors, and the effects of vortex generators are considered.

Anderson, Bernhard H.↗

Evaluation of five conical center-body supersonic diffusers at several angles of attack

Five supersonic inlets having conical center bodies were investigated in a 16-inch ram jet engine with and without combustion at Mach numbers of 1.7, 1.9, and 2.0 and angles of attack from 0 degrees to 10 degrees. Four of the inlets were of the low-mass-flow-ratio type whereas the fifth inlet was of the high-mass-flow-ratio type. The stable operating range of the four low-nass-flow-ratio inlets decreased considerably as the angle of attack was increased despite an increase of the cone angle or the use of boundary-layer bleed. The stable range of the high-mass-flow-ratio inlet increased considerably both at 0 degrees and at greater angles of attack as the free-stream Mach number was decreased. Free-stream Mach number, angle of attack, and inlet type had negligible effects on combustion efficiency, temperature ratio, or combustion-chamber inlet Mach number in the supercritical region.

Englert, Gerald W↗

A novel centrifugal diffuser test device

A large scale (2 in.-wide test vanes at 50-in. inlet diameter), low speed (100-200 ft/sec) steady flow radial cascade wind tunnel for diffuser studies was designed, built and tested. The apparatus was shown to provide flow angles (from radial) in the range of 58-72 deg with suitable spanwise profiles. The novel flow angle control mechanism was shown to work, but measured flow angles were somewhat smaller than expected. The mechanism for controlling case-wall boundary layer profile did not behave as predicted. Attempts to predict the generated flow both analytically and with computational codes are compared with initial measurements. The low speed apparatus will be used to obtain detailed data for diffuser design and analysis code verification, and to provide experience toward the design of a high speed device.

Shreeve, R. P.↗

Methods for reducing pollutant emissions from jet aircraft

Pollutant emissions from jet aircraft and combustion research aimed at reducing these emissions are defined. The problem of smoke formation and results achieved in smoke reduction from commercial combustors are discussed. Expermental results of parametric tests performed on both conventional and experimental combustors over a range of combustor-inlet conditions are presented. Combustor design techniques for reducing pollutant emissions are discussed. Improved fuel atomization resulting from the use of air-assist fuel nozzles has brought about significant reductions in hydrocarbon and carbon monoxide emissions at idle. Diffuser tests have shown that the combustor-inlet airflow profile can be controlled through the use of diffuser-wall bleed and that it may thus be possible to reduce emissions by controlling combustor airflow distribution. Emissions of nitric oxide from a shortlength annular swirl-can combustor were significantly lower than those from a conventional combustor operating at similar conditions.

Butze, H. F.↗

Methods for reducing pollutant emissions from jet aircraft.

The purpose of this paper is to define the problem of pollutant emissions from jet aircraft and to review NASA-Lewis combustion research aimed at reducing these emissions. The problem of smoke formation and results achieved in smoke reduction from commercial combustors are discussed. Experimental results of parametric tests performed on both conventional and experimental combustors over a range of combustor-inlet conditions are presented. Combustor design techniques for reducing pollutant emissions are discussed. Improved fuel atomization resulting from the use of air-assist fuel nozzles has brought about significant reductions in hydrocarbon and carbon monoxide emissions at idle. Diffuser tests have shown that the combustor-inlet airflow profile can be controlled through the use of diffuser-wall bleed and that it may thus be possible to reduce emissions by controlling combustor airflow distribution. Emissions of nitric oxide from a shortlength annular swirl-can combustor were significantly lower than those from a conventional combustor operating at similar conditions.

Butze, H. F.↗

Preliminary Investigation of a New Type of Supersonic Inlet

A supersonic inlet with supersonic deceleration of the flow entirely outside of the inlet is considered. A particular arrangement with fixed geometry having a central body with a circular annular intake is analyzed, and it is shown theoretically that this arrangement gives high pressure recovery for a large range of Mach number and mass flow and therefore is practical for use on supersonic airplanes and missiles. For some Mach numbers the drag coefficient for this type of inlet is larger than the drag coefficient for the type of inlet with supersonic compression entirely inside, but the pressure recovery is larger for all flight conditions. The differences in drag can be eliminated for the design Mach number. Experimental results confirm the results of the theoretical analysis and show that pressure recoveries of 95 percent for Mach numbers of 1.33 and 1.52, 92 percent for a Mach number of 1.72, and 86 percent for a Mach number of 2.10 are possible, with the configurations considered. If the mass flow decreases, the total drag coefficient increases gradually and the pressure recovery does not change appreciably. The results of this work were first presented in a classified document issued in 1946.

DIFFUSERS, SUPERSONIC↗

Zero-angle-of-attack Performance of Two-dimensional Inlets near Mach Number 3

An extensive program was undertaken to investigate the effect of several geometric variables on the performance of two-dimensional inlets. This investigation included inlets having single-wedge, double-wedge, and isentropic compression ramps with various side-plate configurations and subsonic diffusers. The tests were conducted over a range of Reynolds number based on inlet height from 0.50 to 2.67(sup x)10(sup 6). Generally, the performance levels of the two-dimensional inlets were somewhat below those obtained previously with comparable axisymmetric models. At Mach number 3.05 the optimum total-pressure recovery was obtained with an isentropic inlet which compressed the external flow to a Mach number of 1.88. Rectangular side plates and a long high-exit-Mach-number subsonic diffuser with filleted corners were used with this inlet. A critical total-pressure recovery of 0.71 was realized with a corresponding mass-flow ratio of 0.965. Subcritical stability to a mass-flow ratio of 0.60 was obtained.

Woollett, Richard R↗

Dynamic Distortion in a Short S-Shaped Subsonic Diffuser with Flow Separation

An experimental investigation of the time varying distortion at the diffuser exit of a subscale HiMAT forebody and inlet was conducted at Mach 0.9 in the Lewis 8 by 6 foot Supersonic Wind Tunnel. A transitory separation was detected within the subsonic diffuser. Vortex generators were installed to eliminate the flow separation. Results from a study of the instantaneous pressure variations at the diffuser exit are presented. The time unsteady total pressures at the diffuser exit are computer interpolated and presented in the form of a movie showing the transitory separation. Limited data showing the instantaneous distortion levels is also presented.

Stumpf, R.↗

Dynamic distortion in a short s-shaped subsonic diffuser with flow separation

An experimental investigation of the time varying distortion at the diffuser exit of a subsonic HiMAT forebody and inlet was conducted at Mach 0.9 in the Lewis 8 by 6 foot Supersonic Wind Tunnel. A transitory separation was detected within the subsonic diffuser. Vortex generators were installed to eliminate the flow separation. Results from a study of the instantaneous pressure variations at the diffuser exit are presented. The time unsteady total pressures at the diffuser exit are computer interpolated and presented in the form of a movie showing the transitory separation. Limited data showing the instantaneous distortion levels are also presented. Previously announced in STAR as N83-26838

Stumpf, R.↗

Measurements in an annular combustor-diffuser system

Results of three-component Laser Doppler Velocimeter (LDV) measurements in an annular combustor-diffuser system are presented in this paper. The LDV measurements were made at several locations in the prediffuser and dump regions of the combustor-diffuser test rig for three different inlet velocity profiles. The prediffuser average inlet Mach number was maintained at 0.305 during these tests. The LDV data are compared with predictions obtained from a boundary-fitted, two-dimensional elliptic analytical model. The agreement between the LDV data and the predicted results is very good for mean velocities. However, measured turbulence intensities are higher than the predicted values in the region adjacent to the prediffuser walls.

Srinivasan, R.↗

Preliminary Report on Experimental Investigation of Engine Dynamics and Controls for a 48-inch Ram-jet Engine

Engine dynamics and controls data are presented for a ram-jet engine which was operated in a free-jet facility at a Mach number of 2.76 and altitudes from 68,000 to 82,000 feet. The predominant engine dynamic characteristics was dead time, with values ranging from 0.018 to 0.053 sec. The control systems were designed to hold a constant ratio of a diffuser static pressure to an inlet-cone reference static pressure. Response times and percent overshoot to fuel-flow disturbances that would have caused subcritical operation without control are included for a wide range of control settings. For all settings, the control response was fast enough (0.08 to 0.5 sec) to prevent subcritical operation.

Vasu, George↗

Experimental investigation of an axial-flow-compressor inlet stage operating at transonic relative inlet Mach numbers V : rotor blade-element performance at a reduced blade angle

At a corrected speed of 1100 feet per second, the low-blade-angle rotor operated with a relative inlet Mach number of 1.2, a diffusion factor of 0.65, and an axial velocity ratio of 0.71 in the tip region (11 percent of passage height away from the outer wall). The measured minimum-loss coefficient was 0.35, and this value falls above a previous correlation of rotor losses with diffusion factor. Through a comparison with data for three other rotors, the occurrence of high losses was related to a high suction-surface Mach number. These comparisons also indicated that axial velocity ratios between 0.73 and 1.10 have no independent effect on losses.

Schwenk, Francis C↗

Preliminary Investigation of Effect on Performance of Dividing Conical-spike Nose Inlets into Halves at Mach Numbers 1.5 to 2.0

Inserting a splitter plate in the subsonic diffuser caused a pressure-recovery loss of about 1 percent for an inlet with a long nearly constant-area throat section. The loss was due to the increased surface area. Another inlet, which had a comparatively rapid area increase immediately after the throat, experienced pressure-recovery losses of 5 and 6 percent at Mach numbers of 1.8 and 2.0, respectively, and about 1 percent at Mach 1.5.

Allen, John L↗

Performance Characteristics of a Normal-shock Side Inlet Located Downstream of a Canard Control Surface at Mach Numbers of 1.5 and 1.8/

The performance characteristics of a downward canted normal-shock side (scoop) inlet located downstream of a triangular control surface are presented for free-stream Mach numbers of 1.5 and 1.8 in terms of total pressure recovery and mass flow ratio for various boundary-layer removal systems,angles of attack, control surface deflections and adverse yaw. An engine operating condition for a hypothetical turbojet engine is established, and the match point characteristics of the engine-inlet configuration are summarized. 520::It is shown that the diffuser performance increases with increased boundary-layer removal and decreases because of the presence of the wake from the forward control surface. At the higher angles of attack the wake passes over the inlet and does not affect the inlet performance. Adverse yaw reduces the total pressure recovery values below those for the unawed case. Magnitudes of the total pressure recovery were below the theoretical normal-shock recovery for the respective test Mach numbers.

INLETS, SIDE - DUCTED BODIES↗

The effect of prewhirl on the internal aerodynamics and performance of a mixed flow research centrifugal compressor

The internal three-dimensional steady and time-varying flow through the diffusing elements of a centrifugal impeller were investigated using a moderate scale, subsonic, mixed flow research compressor facility. The characteristics of the test facility which permit the measurement of internal flow conditions throughout the entire research compressor and radial diffuser for various operating conditions are described. Results are presented in the form of graphs and charts to cover a range of mass flow rates with inlet guide vane settings varying from minus 15 degrees to plus 45 degrees. The static pressure distributions in the compressor inlet section and on the impeller and exit diffuser vanes, as well as the overall pressure and temperature rise and mass flow rate, were measured and analyzed at each operating point to determine the overall performance as well as the detailed aerodynamics throughout the compressor.

Bryan, William B.↗