Search NASASearch

SEARCH · Search NASA

Results for “Instrumentation and Methods for Astrophysics (astro-ph.IM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3,343 records · Page 14

The Canadian Galactic Emission Mapper (CGEM) A Cosmic Microwave Foreground Experiment

The Canadian Galactic Emission Mapper (CGEM) is a 4-meter single-dish radio telescope located at the Dominion Radio Astrophysical Observatory (DRAO) in Penticton, Canada. CGEM is designed to map polarized Galactic synchrotron emission across the entire northern sky at 8-10 GHz with 1 MHz frequency resolution and ∼ 0.5 degree angular resolution. Its goal is to obtain high-fidelity, low-noise maps of polarized Galactic synchrotron radiation, at frequencies where synchrotron dominates, in order to provide a reliable template for CMB B−mode foreground cleaning. We will show on sky performance of CGEM’s single-pixel azimuthally-symmetric telescope, its coherent, dual-polarized radiometer, and show maps made from commissioning data from the first few months of operation.

Cosmic microwave background

Nuclear Safety [Vol. 36, No. 2, July-December 1995]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. THE CHORNOBYL ACCIDENT: 195 The Chornobyl Accident Revisited, Part III: Chernobyl Source Term Release Dynamics and Reconstruction of Events During the Active Phase, A. R. Sich; GENERAL SAFETY CONSIDERATIONS: 218 Second ANS Workshop on the Safety of Soviet-Designed Nuclear Power Plants, R. A. Bari; 234 Elements of a Nuclear Criticality Safety Program, C. M. Hopper; 243 Rickover, Excellence, and Criticality Safety Programs, R. E. Wilson; ACCIDENT ANALYSIS: 249 Transient Analysis of the PIUS Advanced Reactor Design with the TRAC-PF1/MOD2 Code, B. E. Boyack, J. L Steiner, S. C. Harmony, H. J. Stumpf, and J. F. Lime; 278 The Hierarchy-By-Interval Approach to Identifying Important Models that Need Improvement in Severe-Accident Simulation Codes, T. J. Heames, M. Khatib-Rahbar, J. E. Kelly, R. P. Jenks-Johnson, and Y.-S. Chen; 290 RELAP5/MOD3 Code Coupling Model, R. P. Martin; 299 Missiles Caused by Severe Pressurized-Water Reactor Accidents, R. Krieg; DESIGN FEATURES: 310 Validation of COMMIX with Westinghouse AP-600 PCCS Test Data, J. G. Sun, T. H. Chien, J. Ding, and W T. Sha; ENVIRONMENTAL EFFECTS: 321 Spent Nuclear Fuel Characterization for a Bounding Reference Assembly for the Receiving Basin for Off-Site Fuel, S. D. Kahook, R. L. Garrett, L. R. Canas, and M J. Beckum; OPERATING EXPERIENCES: 332 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 335 Reactor Coolant System Blowdown at Wolf Creek on September 17, 1994, J. V. Kauffman and S. L. Israel; RECENT DEVELOPMENTS: 344 Reports, Standards, and Safety Guides, D. S. Oueener; 349 Proposed Rule Changes as of June 30, 1995; ANNOUNCEMENTS: 320 Symposium on Acceptability of Risk From Radiation—Application to Manned Space Flight; 320 24th DOE/NRC Nuclear Air Cleaning and Treatment Conference; 361 Radiation Biology and Radiation Protection— Modern Developments and Tendencies in Radiation Biology; 362 1997 IEEE Sixth Conference on Human Factors and Power Plants; 354 The Authors; 360 Reviewers of Nuclear Safety, Vol. 36.

05 NUCLEAR FUELS

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Hubble Space Telescope: Battery Capacity Trend Studies

Battery cell wear out mechanisms and signatures are examined and compared to orbital data from the six on-orbit Hubble Space Telescope (HST) batteries, and the Flight Spare Battery (FSB) Test Bed at Marshall Space Flight Center (MSFC), which is instrumented with individual cell voltage monitoring. Capacity trend data is presented which suggests HST battery replacement is required in 2005-2007 or sooner.

Rao, M. Gopalakrishna

Next-Generation Hard X-ray Missions: SuperHERO and HEROIX

High-energy X-ray observations have transformed our understanding of astrophysical systems where non-thermal processes dominate, from shock-accelerated particles in supernova remnants to relativistic jets and hot coronae in active galactic nuclei. NuSTAR’s pioneering focusing images of the hard X-ray sky have demonstrated the immense scientific potential of this band, while also highlighting how limited angular resolution constrains our ability to fully characterize complex physical processes in faint extended sources and resolving faint sources in crowded sky regions. In this presentation, I will discuss a pathway to overcome these challenges through NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology. Specifically, I will discuss the SuperHERO hard X-ray telescope to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon flight observing the Crab Nebula, and the High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept to achieve an integrated effective area of 570 cm2 at 30 keV with 5 arcsec HPD angular resolution.

AGN

Scientific Highlights and Status of the Mars Science Laboratory Mission, Years 9 through 12

We present the scientific highlights and status from years 9-12 of NASA’s Mars Science Laboratory mission, with its Curiosity rover. A thermochemolysis-based sample analysis revealed a variety of organic molecules preserved in clay mineral-rich lake/lake margin deposits of the Glen Torridon region. The stratigraphically higher clay-sulfate mineral transition on Aeolis Mons was found to be associated with a lithological change from lacustrine to dry aeolian depositional environments. Water intermittently returned to the surface after the increase in aridity, including during the deposition of wave ripple strata which indicate a climate capable of sustaining an ice-free lake in the early Hesperian. The overlying Mg sulfate-bearing unit has both poly- and monohydrated Mg sulfates and is also enriched in iron carbonate of a purity consistent with chemical sedimentation and therefore atmospheric sequestration. A channel-incised canyon within Gediz Vallis and distal alluvial deposits recorded numerous fluvial and debris flow events after the deposition, lithification, and erosion of the clay- and sulfate-bearing units. Bright clasts found in Gediz Vallis canyon are composed of native sulfur. The investigation of the modern atmosphere and environment focused on the influence of the crater and mountain topography and captured high-altitude noctilucent and iridescent clouds. Radiation monitoring now spans an 11-year solar cycle. Rover systems and science instruments remain capable of addressing mission scientific objectives. All ten scientific instruments continue to return high-value data despite degradation of the Chemistry and Camera instrument’s high-voltage system, loss of multispectral imaging capability, and loss of active neutron spectroscopy. The mission has mitigated the loss of redundant brakes on two arm joints, additional wheel wear, and highly reduced capability of the redundant flight computer. Efficiency improvements in rover energy utilization and operations staffing have allowed the mission team to maintain a high level of productivity despite declining rover power generation and funding.

Mars

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Computation of Optimal Interplanetary Low-Thrust Trajectories With Bounded Thrust Magnitude By Means of the Generalized Newton-Raphson Method

The generalized Newton-Raphson method, an iterative procedure for solving nonlinear operator equations, has been extended in application to variational problems with bounded control variables. A minimum fuel interplanetary low thrust orbital transfer problem is worked out in detail to demonstrate the practical aspects of the algorithm as well as its computational effectiveness. The control variables are the thrust magnitude, limited from zero to some prescribed maximum value, and the thrust steering angle.

Computation

Ground-Based Microwave Measurements of ClO and O3 Over Scott Base, Antarctica

We present measurements from a new microwave instrument that has been deployed at Scott Base, Antarctica, primarily to measure ClO. The new instrument allows for the extension of the time series of lower stratospheric ClO measurements begun in 1996 at this site, while some of the technical improvements offer the possibility of making additional measurements. We show measurements of ClO and O 3 in both the upper and lower stratosphere near both the fall and spring equinox and document the diurnal variations of these measurements throughout the season. The ground-based measurements are compared with Aura Microwave Limb Sounder (MLS) measurements, which are available twice per day, and with a NASA Goddard 2D model (GSFC2D) simulation. We show that, in agreement with the GSFC2D model diurnal variations, upper stratospheric ClO mixing ratios gradually increase throughout the daylight hours, while in the lower stratospheric austral spring, when heterogeneous chemistry associated with polar stratospheric clouds occurs, daily maximum ClO mixing ratios of near 2 ppbv occur near noon. We also show measurements of stratospheric O 3 , primarily in the upper stratosphere, which, while exhibiting a low bias of ∼15%–20% relative to Aura MLS, show temporal variations in good agreement with MLS.

stratospheric ozone

A method for battery activation

A technique to activate nickel cadmium batteries is described. The method shortened the time required for activation, eliminated the temperature rise in the batteries, and produced a voltage on the discharge that was better than when the C/20 was run for 48 hours during tests. Various methods of activation are described and evaluated. Results of alternate conditioning charge schemes are presented along with voltage/temperature characteristics for multiple level nickel cadmium battery chargers.

Halpert, G.