Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Vigilance and task load - In search of the inverted U

The 'Inverted-U Hypothesis' states that for a given task, there is an optimal level of workload or demand that yields the highest level of performance. A departure in either direction will result in a monotonically lower performance level, hence an inverted-U-shaped relationship between task demand and quality of performance. Most studies to date have failed to demonstrate the left-hand branch of the curve, that is, the regime in which performance presumably rises as load increases. The purpose of this study was to explore whether low-level additional demand on the monitor would result in improved performance. Four groups of subjects performed a visual monitoring task for 48 min, then two of the four groups were given additional tasks, and a third had potentially distracting information on its display. Results indicated that the two groups with additional demand detected more signals than did the control group or the control-plus-distraction group. There were no significant differences in false alarms.

Wiener, E. L.↗

High-altitude observations of an intense inverted V event

Inverted-V events which generally occur in the pre-midnight sector over the auroral zone are frequently associated with reversals in the convection electric field. Such a reversal is observed by the University of Iowa quasispherical LEPEDEA on board ISEE 1 at an altitude of 13 RE on May 1, 1978. The bulk of the plasma shows a large shear over a five-minute interval. The associated change in the convection electric field is 5.1 mV/m. Large values of the field-aligned current are simultaneously detected. The potential structure appears to extend to the satellite location. Using a theoretical model, the field-aligned current due to the electric field discontinuity has been calculated. The magnitude of the parallel potential drop and width of the inverted-V region agree well with observation.

Huang, C. Y.↗

Program Predicts Nonlinear Inverter Performance

Program developed for ac power distribution system on Shuttle orbiter predicts total load on inverters and node voltages at each of line replaceable units (LRU's). Mathematical model simulates inverter performance at each change of state in power distribution system.

Al-Ayoubi, R. R.↗

Shock associated noise of inverted-profile coannular jets. I - Experiments

The reduction of shock-associated noise in inverted-velocity-profile coannular jets is quantified and explained by conducting extensive optical and acoustic measurements for a suitable range of outer-stream and inner-stream presure-ratio combinations, and by interpreting the measured noise results with the aid of new theoretical models. It is shown that the shock noise from the outer stream is virtually eliminated when the inner stream is operated at a Mach number just above unity, regardless of all the other jet operating parameters. Furthermore, this reduction can be achieved at inverted-velocity-profile as well as normal-velocity-profile conditions.

Tanna, H. K.↗

A diagonally inverted LU implicit multigrid scheme

A new Diagonally Inverted LU Implicit scheme is developed within the framework of the multigrid method for the 3-D unsteady Euler equations. The matrix systems that are to be inverted in the LU scheme are treated by local diagonalizing transformations that decouple them into systems of scalar equations. Unlike the Diagonalized ADI method, the time accuracy of the LU scheme is not reduced since the diagonalization procedure does not destroy time conservation. Even more importantly, this diagonalization significantly reduces the computational effort required to solve the LU approximation and therefore transforms it into a more efficient method of numerically solving the 3-D Euler equations.

Yokota, Jeffrey W.↗

A diagonally inverted LU implicit multigrid scheme

A new Diagonally Inverted LU Implicit scheme is developed within the framework of the multigrid method for the three-dimensional unsteady Euler equations. The matrix systems that are to be inverted in the LU scheme are treated by local diagonalizing transformations that decouple them into systems of scalar equations. Unlike the Diagonalized ADI method, the time accuracy of the LU scheme is not reduced since the diagonalizing procedure does not destroy time conservation. Even more importantly, this diagonalization significantly reduces the computational effort required to solve the LU approximation and therefore transforms it into a more efficient method of numerically solving the three-dimensional Euler equations.

Yokota, J. W.↗

Theoretical investigation of the oceanic inverted barometer response

Dynamic tidal theory is generalized in order to predict the oceanic response to atmospheric pressure variations. The oceans are found to exhibit distinct dynamic behavior when forced at periods less than one week; depending on the harmonic type of forcing, the amplitude of the response can differ by about 20 percent or more from the static response. Even at roughly two months the traditional 'inverted barometer' may not be sufficiently accurate for applications in which detection of long-term sea level trends or vertical crustal motion is the goal. For forcing at periods of order one year the oceanic response differs by at most a few percent from the static (not the inverted barometer) response; thus calculations of meteorological excitation of the annual and Chandler wobbles can employ the static approximation without reservation.

Dickman, S. R.↗

A design procedure for the phase-controlled parallel-loaded resonant inverter

High-frequency-link power conversion and distribution based on a resonant inverter (RI) has been recently proposed. The design of several topologies is reviewed, and a simple approximate design procedure is developed for the phase-controlled parallel-loaded RI. This design procedure seeks to ensure the benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. The load is considered to be a linear impedance (or an ac current sink). The design procedure is verified using a 2.5-kVA 20-kHz RI. Also obtained are predictable worst-case ratings for each component of the resonant tank circuit and the inverter switches. For a given load VA requirement, below-resonance operation is found to result in a significantly lower tank VA requirement. Under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible.

King, Roger J.↗

Suspended Patch Antennas With Electromagnetically Coupled Inverted Microstrip Feed for Circular Polarization

The paper demonstrates a suspended nearly square patch antenna with offset feed and a square patch antenna with truncated corners for circular polarization. The antennas are excited by an electromagnetically coupled inverted microstrip feed. In addition a new transition between conventional microstrip and inverted microstrip is proposed. The measured results include the axial ratio and the impedance bandwidth of the antennas.

Simons, Rainee N.↗

Experimental Investigation of Composite Pressure Vessel Performance and Joint Stiffness for Pyramid and Inverted Pyramid Joints

The focus of this study is on the suitability in the application of classical laminate theory analysis tools for filament wound pressure vessels with adhesive laminated joints in particular: pressure vessel wall performance, joint stiffness and failure prediction. Two 18-inch diameter 12-ply filament wound pressure vessels were fabricated. One vessel was fabricated with a 24-ply pyramid laminated adhesive double strap butt joint. The second vessel was fabricated with the same number of plies in an inverted pyramid joint. Results from hydrostatic tests are presented. Experimental results were used as input to the computer programs GENLAM and Laminate, and the output compared to test. By using the axial stress resultant, the classical laminate theory results show a correlation within 1% to the experimental results in predicting the pressure vessel wall pressure performance. The prediction of joint stiffness for the two adhesive joints in the axial direction is within 1% of the experimental results. The calculated hoop direction joint stress resultant is 25% less than the measured resultant for both joint configurations. A correction factor is derived and used in the joint analysis. The correction factor is derived from the hoop stress resultant from the tank wall performance investigation. The vessel with the pyramid joint is determined to have failed in the joint area at a hydrostatic pressure 33% value below predicted failure. The vessel with the inverted pyramid joint failed in the wall acreage at a hydrostatic pressure within 10% of the actual failure pressure.

Verhage, Joseph M.↗

Buckling Design Studies of Inverted, Oblate Bulkheads for a Propellant Tank

An investigation of the deformation and buckling characteristics of a composite, oblate bulkhead that has an inverted geometry and is subjected to pressure-only loading is presented for three bulkhead geometries and thicknesses. The effects of a stiffening support ring at the bulkhead to cylinder interface are also evaluated. Buckling analyses conducted using the axisymmetric shell code BOSOR4 are discussed for several bulkhead configurations. These results are analytically verified using results from the Structural Analysis of General Shells (STAGS) code for a selected bulkhead configuration. The buckling characterization of an inverted, oblate bulkhead requires careful attention as small changes in bulkhead parameters can have a significant effect on the critical buckling load. Comparison of BOSOR4 and STAGS results provided a very good correlation between the two analysis methods. In addition, the analysis code BOSOR4 was found to be an efficient sizing tool that is useful during the preliminary design stage of a practical shell structure. Together, these two aspects should give the design engineer confidence in sizing these stability critical structures. Additional characterization is warranted, especially for a composite tank structure, since only one bulkhead configuration was examined closely.

Smeltzer, Stanley S., III↗

Power supply circuit for an ion engine sequentially operated power inverters

A power supply circuit for an ion engine suitable for a spacecraft has a voltage bus having input line and a return line. The power supply circuit includes a pulse width modulation circuit. A plurality of bridge inverter circuits is coupled to the bus and the pulse width modulation circuit. The pulse width modulation circuit generates operating signals having a variable duty cycle. Each bridge inverter has a primary winding and a secondary winding. Each secondary winding is coupled to a rectifier bridge. Each secondary winding is coupled in series with another of the plurality of rectifier bridges.

Cardwell, Jr., Gilbert I.↗

Machine Learning for Dynamical Modeling of a Flexible Inverted Pendulum System

The inverted pendulum system, a canonical example of an unstable mechanical system, is often used to model the control problems encountered in the flight of rockets in the initial stages of launch, when the airspeed is too small for aerodynamic stability. A system with a flexible pendulum is a variant that more accurately simulates rocket flight nonlinearities (particularly, the flex modes of the rocket). To increase NASA capability of modeling dynamical systems for which closed form solutions are not clear or easily developed, this project aims to provide a machine learning approach that produces a learned dynamical model of the PENNY robot (a rover with a flexible inverted pendulum) from operational data. The developed approach can then be generalized to other complex dynamical systems, including but not limited to rockets and other robotic systems.

M. A. DuPuis↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states.For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management system↗

Propulsion System Design using a Dual 3-Phase PM Synchronous Reluctance Machine with X-Type Multi-Level GaN Inverter

— A propulsion system design is exhibited here that comprises of an X-type GaN power module based dual multi-level inverter and a PM Synchronous Reluctance motor. With the critical benefits of multi-level operation, namely low common mode EMI noise, low switching loss, low current Total Harmonic Distortion (THD), smoother torque and lower iron loss, this topology targets high system-level efficiency and high power density while using reduced rare earth (RE) elements in its motor. General Motors and Purdue University jointly designed and developed this 800V class, highly scalable traction drive that can deliver 200+ kW of power suitable for C-SUV to truck vehicle class. The 3-phase electric machine design utilizes dual winding with 6 terminals to work in line with the GaN X-type inverter, and results in a tractive solution that ensures higher machine efficiency while reducing cost and uncertainty related to use and availability of heavy rare earth/rare earth elements in its rotor.

MOMEN, FAIZUL [General Motors LLC, Detroit, MI (Un↗

Optimal Hairpin Winding Configuration for EV Traction Motors to Enhance Active CMV Cancellation Capability of NPL.X Inverter

Active common-mode voltage (CMV) cancellation in neutral-point-less (NPL.X) inverter is an effective approach for reducing common-mode electromagnetic interference and alleviating voltage stress associated with high-speed switching in EV traction drives. However, the existing hairpin winding configuration often exhibits impedance imbalance due to slot leakage inductance and manufacturing constraints, limiting the effectiveness of active CMV cancellation. This paper investigates symmetric hairpin winding configurations for a dual-three-phase EV traction machine to improve impedance symmetry. Considering the manufacturing constraints of six-layer hairpin windings, four feasible symmetric winding configurations are analyzed. Two-dimensional finite-element analysis is performed to extract the impedance parameters of each configuration. The extracted impedance parameters are used to quantify the impedance mismatch between complementary phase pairs and evaluate its influence on active CMV cancellation. The results show that the fully interleaved winding configuration achieves perfectly balanced phase impedances with 0 % mismatch, whereas the mismatch in the other configurations ranges from approximately 2.4 % to 0.8 %. Consequently, the resulting total CMV overshoot is significantly suppressed to near zero voltage under high-voltage and high switching frequency operating conditions, demonstrating the importance of winding symmetry for maximizing the active CMV cancellation capability of the NPL.X inverter.

Lee, Kangbeen [Purdue Univ., West Lafayette, IN (U↗

Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems with Coupled and Full-Order Dynamics from Control Systems and Power Networks

The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. Here, in this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.

14 SOLAR ENERGY↗

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗