Search NASA⌕ Search

SEARCH · Search NASA

Results for “Iodine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Review and Experimental Comparison of the Durability of Iodine Waste Forms in Semi-Dynamic Leach Testing

To ensure the safe disposal of radioiodine-containing nuclear wastes, a durable iodine waste form (IWF) is required. Many IWFs have been developed and evaluated for chemical durability using a wide range of test methods, making direct comparisons difficult as highlighted in this work through a review of available IWF corrosion data. To move toward a common dataset, a semi-dynamic leach test suite was experimentally demonstrated using several IWF types, providing standard comparisons. The results highlighted clear differences in corrosion resistance between various IWFs. This test suite is suggested for future studies to generate comparable data for a common dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iodine Removal from Carbonate-Containing Alkaline Liquids Using Strong Base Resins, Hybrid Resins, and Silver Precipitation

The ability of several material types to remove aqueous iodine from a mildly alkaline, carbonate-rich nuclear waste stream was evaluated: strong base anion exchange resins (SBAR), hybrid resins, Ag-containing materials and Bi-containing hybrid resins. A combination of batch testing and flow through column testing were used in the evaluation. In batch testing, hybrid resins CHM-20, SIR-110-CE and RTBI were shown to have high efficiency for the removal of both iodide and iodate simultaneously, while Ag-containing materials and SBAR demonstrated high capacity for iodide removal. One example of each material type (CHM-20, A532E and Ionex 400) were further evaluated for their sorption isotherms and column performance. The Langmuir isotherm, or a Langmuir-Freundlich hybrid isotherm, best described the sorption of iodide to the CHM-20 hybrid resin and Purolite A532E. The Freundlich isotherm best described the uptake of iodate to CHM-20 and A532E and for both iodide and iodate to the Ag-containing Ionex-400. In column testing the Purolite A532E had exceptional performance for overall iodide removal. With the capacity demonstrated the A532E resin would exceed Class C waste classification before breakthrough initiated, and column change outs in processing would be dictated by eventual waste classification, not breakthrough. The Ionex 400, a Ag-zeolite, was observed to degrade over time in the column in the mild alkaline conditions whereas the hybrid CHM-20 was limited in the single pass through design and would be best suited for applications where iodide and iodate are present and recirculation of the column effluent is feasible. Here this work highlights the feasibility of commercially available materials to separate radioiodine from liquid environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absolute Band Intensity of the Iodine Monochloride Fundamental Mode for Infrared Sensing and Quantitative Analysis

Iodine monochloride (ICl) is a gaseous off-product of molten salt reactors; monitoring this heteronuclear diatomic is of great interest for both environmental and safety purposes. In this paper we investigate the possibility of infrared monitoring of ICl by measuring the far-infrared absorption cross section of its fundamental band near 381 cm -1 . We have performed quantitative studies of the neat gas in a 20 cm cell at 25, 35, 50 and 70 oC at multiple pressures up to ~ 9 Torr and investigated the temperature and pressure dependence of the band’s infrared cross section. Quantitative measurements were problematic due to sample adhesion to the cell walls and windows as well as reactions/possible hydrolysis of ICl to form HCl gas. Effects were mitigated by measuring only the neat gas, using short measurement times and subtracting out the partial pressure of the HCl(g). The integrated band strength is shown to be temperature independent and was found to be equal to 9.1 x 10 -19 (cm 2 /molecule) cm-1. As expected, the temperature dependence of the band profile showed only a small effect over this limited temperature range. Furthermore, we have also investigated using the absorption data along with inverse least squares multivariate methods for the quantitative monitoring of ICl effluent concentrations under different scenarios using infrared (standoff) sensing and compare these results with traditional Beer’s Law (univariate) techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iodine’s Wild Ride Leading to Photoinstability in Halide Perovskite Solar Cells

Understanding processes that contribute to efficiency losses during long-term operation of perovskite solar cells is crucial for achieving operational stability. Although maximum power point tracking optimizes outdoor performance, it is not uncommon that devices are kept under open-circuit conditions during sunny hours. Under these conditions, charge carriers accumulate at the interfaces rather than flowing through the circuit. In the case of the MAPbI 3 /spiro-OMeTAD interface studied here, hole accumulation leads to formation of I2 and subsequent oxidation of spiro-OMeTAD. By employing in situ absorption measurements, we show that the decrease in power conversion efficiency follows the spiro-OMeTAD oxidation while operating the device under open-circuit conditions. In short-circuit conditions, where photogenerated charge carriers are extracted in the external circuit, the I 2 -induced oxidation of spiro-OMeTAD and the device instability are minimized. The photoinduced expulsion of iodine from MAPbI 3 into spiro-OMeTAD discussed in this work provides new insight into the photoinstability of perovskite solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorption of Radioactive Iodine Using Nanocarbon on ETS-10 as Adsorbent

Here, laboratory-synthesized nanocarbon pelletized with titanosilicate (ETS-10) as a support matrix has been investigated for the capture of radioactive iodine present as methyl iodide (CH 3 I) in the off-gas streams produced during aqueous reprocessing of used nuclear fuel. The mass fraction of carbon in the sorbent matrix was 0.10. The effects of residence time and CH 3 I concentration were investigated using a continuous flow column setup to quantify the adsorption and desorption capacities of adsorbent under dynamic conditions from an air stream containing CH 3 I present at concentrations representative of those expected in the off-gas streams. Air with CH 3 I gas as a source in the column resulted in quantifiable CH 3 I adsorption with 0.98 mg/g of adsorption capacity. Laboratory-made nanocarbons had a larger adsorption capacity than those of the other carbons reported in the literature. Additionally, the adsorption capacity of nanocarbon on ETS-10 is compared to that of nanocarbon coated on cordierite in previous studies.

ETS-10↗

Iodine interstitials as a cause of nonradiative recombination in hybrid perovskites

The identification of deep-level defects that act as detrimental nonradiative recombination centers is critical for optimizing the optoelectronic performance of hybrid perovskites. Although extensive studies have been devoted to revealing the nature of deep-level defects in hybrid perovskites, it is still unclear what defects are responsible for the experimentally observed nonradiative recombination rates. Employing first-principles approaches, we quantitatively show that the iodine interstitial is a dominant nonradiative recombination center in methylammonium-lead iodide. Finally, this important insight points to a target for defect engineering in order to further improve the performance of hybrid perovskites.

36 MATERIALS SCIENCE↗

Iodine Mass Tracking Research and Development Needs for Pyrochemical Fuel Cycles

This report was generated jointly by Argonne National Laboratory (ANL) and Idaho National Laboratory to provide a high-level summary of the current knowledge on the behavior of fission product iodine during reprocessing of used nuclear fuel, as well as provide recommended path forward for research and development activities to fill particular knowledge gaps. The focus of this work is on pyrochemical processing as is applied to light water reactor (LWR) oxide-based used nuclear fuels (UNF), however, some discussion of electrorefiner behavior from metal fuel processing equipment is also included.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Control of iodine and tellurium for use in domestic molybdenum-99 production efforts

Three initial proof-of-concept experiments were performed to test the removal of I and Te from solutions containing Mo for potential abatement during chemical processing to purify 99 Mo. All three proof-of-concept experiments produced results indicating that further optimization could provide methods for I and/or Te abatement from multiple matrices. Decamp and Happel (2013) describe the use of CL resin from Eichrom Technologies loaded with Ag + combined with Amberlite XAD-4 in the chromatographic separation of irradiated fission products in 1 M HNO 3 to separate iodine species where iodide and iodate react with Ag + and I2 adheres to the Amberlite resin. The method worked well under processing conditions in a medical isotope facility although many separation methods use higher concentrations of HNO 3 which could adversely impact the Ag + loading. The experiment performed here used a roughly 2 mL column of CL resin loaded with Ag + and Amberlite XAD-4 to separate µg quantities of I, Te, and Mo in 3 M HNO 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

First Observations of Iodine Oxide from Space

We present retrievals of IO total columns from the Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY) satellite instrument. We analyze data for October 2005 in the polar regions to demonstrate for the first time the capability to measure IO column abundances from space. During the period of analysis (i.e. Southern Hemisphere springtime), enhanced IO vertical columns over 3 x 10(exp 13) molecules cm(exp -2) are observed around coastal Antarctica; by contrast during that time in the Arctic region IO is consistently below the calculated instrumental detection limit for individual radiance spectra (2-4 x 10(exp 12) molecules cm(exp -2) for slant columns). The levels reported here are in reasonably good agreement with previous ground-based measurements at coastal Antarctica. These results also demonstrate that IO is widespread over sea-ice covered areas in the Southern Ocean. The occurrence of elevated IO and its hitherto unrecognized spatial distribution suggest an efficient iodine activation mechanism at a synoptic scale over coastal Antarctica.

emissions↗

The Development and Deployment of a Ground-Based, Laser-Induced Fluorescence Instrument for the In Situ Detection of Iodine Monoxide Radicals

High abundances of iodine monoxide (IO) are known to exist and to participate in local photochemistry of the marine boundary layer. Of particular interest are the roles IO plays in the formation of new particles in coastal marine environments and in depletion episodes of ozone and mercury in the Arctic polar spring. This paper describes a ground-based instrument that measures IO at mixing ratios less than one part in 1012. The IO radical is measured by detecting laser-induced fluorescence at wavelengths longer that 500 nm. Tunable visible light is used to pump the A23/2 (v = 2) ← X23/2 (v = 0) transition of IO near 445 nm. The laser light is produced by a solid-state, Nd:YAG-pumped Ti:Sapphire laser at 5 kHz repetition rate. The laser-induced fluorescence instrument performs reliably with very high signal-to-noise ratios (>10) achieved in short integration times (<1 min). The observations from a validation deployment to the Shoals Marine Lab on Appledore Island, ME are presented and are broadly consistent with in situ observations from European Coastal Sites. Mixing ratios ranged from the instrumental detection limit (<1 pptv) to 10 pptv. These data represent the first in situ point measurements of IO in North America.

marine boundary layer↗

Overview of Iodine Propellant Hall Thruster Development Activities at NASA Glenn Research Center

NASA is continuing to invest in advancing Hall thruster technologies for implementation in commercial and government missions. There have been several recent iodine Hall propulsion system development activities performed by the team of the NASA Glenn Research Center, the NASA Marshall Space Flight Center, and Busek Co. Inc. In particular, the work focused on qualification of the 200 W Busek BHT-200-I and the continued development of the 600 W BHT-600-I Hall thruster propulsion systems. This paper presents an overview of these development activities and also reports on the results of short duration tests that were performed on the engineering model BHT-200-I and the development model BHT-600-I Hall thrusters.

Hall Thrusters↗

Overview of Iodine Propellant Hall Thruster Development Activities at NASA Glenn Research Center

NASA is continuing to invest in advancing Hall thruster technologies for implementation in commercial and government missions. There have been several recent iodine Hall propulsion system development activities performed by the team of the NASA Glenn Research Center, the NASA Marshall Space Flight Center, and Busek Co. Inc. In particular, the work focused on qualification of the Busek BHT-200-I, 200 W and the continued development of the BHT-600-I Hall thruster propulsion systems. This presentation presents an overview of these development activities and also reports on the results of short duration tests that were performed on the engineering model BHT-200-I and the development model BHT-600-I Hall thrusters.

Electric Propulsion↗