At least 253 records · Page 14

Numerical simulation of ion charge breeding in electron beam ion source

The Electron Beam Ion Source particle-in-cell code (EBIS-PIC) tracks ions in an EBIS electron beam while updating electric potential self-consistently and atomic processes by the Monte Carlo method. Recent improvements to the code are reported in this paper. The ionization module has been improved by using experimental ionization energies and shell effects. The acceptance of injected ions and the emittance of extracted ion beam are calculated by extending EBIS-PIC to the beam line transport region. An EBIS-PIC simulation is performed for a Cs charge-breeding experiment at BNL. The charge state distribution agrees well with experiments, and additional simulation results of radial profiles and velocity space distributions of the trapped ions are presented.

43 PARTICLE ACCELERATORS↗

A self-sputtering ion source: A new approach to quiescent metal ion beams

A new metal ion source is presented based on sustained self-sputtering plasma in a magnetron discharge. Metals exhibiting high self-sputtering yield like Cu, Ag, Zn, and Bi can be used in a high-power impulse magnetron sputtering (HIPIMS) discharge such that the plasma almost exclusively contains singly charged metal ions of the target material. The plasma and extracted ion beam are quiescent. The ion beams consist mostly of singly charged ions with a space-charge limited current density which reached about 10 mA/cm2 at an extraction voltage of 45 kV and a first gap spacing of 12 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Industrial ion source technology

A 30 cm electron bombardment ion source was designed and fabricated for micromachining and sputtering applications. This source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. An average ion current density of 1 ma/sq cm with 500 eV argon ions was selected as a design operating condition. The ion beam at this operating condition was uniform and well collimated, with an average variation of plus or minus 5 percent over the center 20 cm of the beam at distances up to 30 cm from the ion source. A variety of sputtering applications were undertaken with a small 10 cm ion source to better understand the ion source requirements in these applications. The results of these experimental studies are also included.

Kaufman, H. R.↗

A new H{sub 2}{sup +} source: Conceptual study and experimental test of an upgraded version of the VIS—Versatile ion source

The versatile ion source is an off-resonance microwave discharge ion source which produces a slightly overdense plasma at 2.45 GHz of pumping wave frequency extracting more than 60 mA proton beams and 50 mA He{sup +} beams. DAEδALUS and IsoDAR experiments require high intensities for H{sub 2}{sup +} beams to be accelerated by high power cyclotrons for neutrinos generation. In order to fulfill the new requirements, a new plasma chamber and injection system has been designed and manufactured for increasing the H{sub 2}{sup +} beam intensity. In this paper the studies for the increasing of the H{sub 2}{sup +}/p ratio and for the design of the new plasma chamber and injection system will be shown and discussed together with the experimental tests carried out at Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali del Sud (INFN-LNS) and at Best Cyclotron Systems test-bench in Vancouver, Canada.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of tungsten filament in gas discharge in H - ion source

Sources of negative ions such as H - are essential elements of proton accelerators and tokamaks. They have limited lifetime. The replacement of an ion source is a costly process causing delays in the operation of the entire machine. The hot tungsten filament is the key element that limits the lifetime of the H - ion source at the Los Alamos Neutron Science Center (LANSCE) facility. An accurate model, which describes the filament physics and provides a reliable estimate on its lifetime, may significantly improve the operation of the facility. In this report we describe such a model, including a comprehensive list of relevant physical processes from first principles. The model can be used to describe different regimes of operation using diagnostics data as input parameters. It has been benchmarked against the data collected during the production cycle at LANSCE and shows good agreement with experimental data.

47 OTHER INSTRUMENTATION↗

Preparation of a 73 As source sample for application in an offline ion source

For the generation of beams with the offline ion source at the Facility for Rare Isotope Beams (FRIB), suitable source samples are required. Arsenic-73 is a frequently requested user beam due to its significance in nuclear structure studies and astrophysics. In this work, we outline the process of preparing a 73 As source sample, containing (5.76 ± 0.37)∗10 14 atoms of 73 As, which was successfully used to generate a 73 As beam for a multi-day user experiment. Silver arsenate was chosen as the chemical form, due to its favorable volatility within the designated operating temperature range. We refined the precipitation method using stable arsenic prior to its application with the 73 As sample, resulting in precipitation yields of (99.4 ± 4.5)%.

As-73↗

Operation status of the electron cyclotron resonance ion source at Gunma University

An ECR ion source of Gunma University Heavy Ion Medical Center, so-called KeiGM [M. Muramatsu, A. Kitagawa, Y. Sakamoto, S. Sato, Y. Sato, H. Ogawa, S. Yamada, H. Ogawa, Y. Yoshida, and A. G. Drentje, Rev. Sci. Instrum. 76, 113304 (2005)], has been operated for cancer therapy and physical/biological experiment since 2010. KeiGM produces typically 230 μA of 10 keV/u C{sup 4+} ions from CH{sub 4} gases. The vacuum pressure is kept between 1.2 × 10{sup −4} and 1.7 × 10{sup −4} Pa so as to suppress the pulse-to-pulse current fluctuation within ±10%. The extraction electrode is cleaned every 6–8 months in order to remove deposited carbon, which increases the leak current and discharge. In order to investigate the possibility of long-term operation without such maintenances, oxygen aging for the cleaning of the extraction electrode has been tested in the test bench. The same-designed ion sources at National Institute of Radiological Sciences and SAGA Heavy Ion Medical Accelerator in Tosu (SAGA-HIMAT) are also operated with stable C{sup 4+} current, which are suitable for the continuous operation for cancer therapy.

43 PARTICLE ACCELERATORS↗

Experimental development on the 18 mA, H{sup -} multi-cusp ion source at China Institute of Atomic Energy

The ion source is one of the key devices for the high-intensity cyclotron, which exerts influence on the beam intensity and applications of the machine. The H{sup -} multi-cusp ion source developed at China Institute of Atomic Energy has been used to perform experimental study on beam intensity and emittance versus the bias voltage, arc power, lens voltage, and pressure of the ion source. Up to now, 18 mA H{sup -} ion beam with emittance of 0.93 {pi}mm mrad (four times RMS normalized emittance) was obtained from this ion source through the in-depth study and optimization on some essential factors affecting the beam intensity and quality. The paper will present the experimental study on the ion source as well as the beam test results.

43 PARTICLE ACCELERATORS↗

Recent operation status of Japan Proton Accelerator Research Complex H{sup -} ion source

A cesium-free H{sup -} ion source driven with a LaB{sub 6} filament is being operated at the Japan Proton Accelerator Research Complex for approximately three years without any serious trouble. In the beam commissioning or supply runs, the ion source has been operated in two different modes such as low current mode of 5 mA and high current mode of 30 mA. The total interruption time during the runs due to the ion source failure is approximately 50 h, which correspond to the ion source availability of 99%. After a long-term operation, the surface of the filament and the plasma electrode become discolored with dark partially. The result of surface analysis with field emission scanning electron microscope showed that most of the dark material is formed with boron. At the beam test performed in the interval of the run, we demonstrated that the H{sup -} current increased by miniaturizing the LaB{sub 6} filament.

43 PARTICLE ACCELERATORS↗

Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source

A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.

43 PARTICLE ACCELERATORS↗

Linear ion source with closed drift and extended acceleration region

Ion source with closed drift, which is caused by ExB field, and extended acceleration region is discussed. Though conventional circular-type closed drift ion source has advantages of high efficiency of gas ionization and low ion beam energy, there is a limitation in enlarging the beam size. Linear ion source with horse-track shape with 270 mm ceramic channel width is newly designed and tested. Inert gas (Ar) and reactive gas (O{sub 2}) are discharged. Discharge is ignited with voltage of 90 V. Discharge current is proportional to discharge voltage and increases up to 16.3 A in argon and 15.6 A in oxygen at discharge voltage of 320 V. Extracted ion beam current is also proportional to discharge voltage and is saturated after 280 V for both gases. It is measured up to 0.78 mA/cm{sup 2} in argon beam and 0.73 mA/cm{sup 2} in oxygen beam at a distance of 100 mm from the ion source. Argon ion beam shows better space uniformity than oxygen across the beam extraction region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a cold cathode Penning ion source for the implantation of noble gases beneath 2D monolayers on metals: Ions and neutrals

Argon ion kinetic energy spectra at different discharge voltages (between 480 and 600 V) of a commercial cold cathode ion source IQP10/63 are reported. The high kinetic energy cut-off depends on the discharge voltage and the corresponding plasma potential due to excess positive charges which is found to be about 136 V. Exposure of single layer hexagonal boron nitride on rhodium to the beam of the ion source leads to the formation of nanotents, i.e., stable atomic protrusions. A positive bias voltage is applied to the target sample to block the positive ions produced by the ion source. However, application of a positive bias potential (800 eV), which is higher than the kinetic energy cut-off, still allows the formation of nanotents and its observation with scanning tunneling microscopy. This indicates that the ion source also produces neutral atoms with kinetic energies higher than the penetration threshold across a single layer of hexagonal boron nitride.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An overview of LINAC ion sources

This paper discusses ion sources used in high-duty-factor proton and H{sup -} Linacs as well as in accelerators utilizing multi-charged heavy ions, mostly for nuclear physics applications. The included types are Electron Cyclotron Resonance (ECR) sources as well as filament and rf driven multicusp sources. The paper does not strive to attain encyclopedic character but rather to highlight major lines of development, peak performance parameters and type-specific limitations and problems of these sources. The main technical aspects being discussed are particle feed, plasma generation and ion production by discharges, and plasma confinement.

43 PARTICLE ACCELERATORS↗

RF Heating in Electron Cyclotron Resonance Ion Sources

ECRIS-Electron Cyclotron Resonance Ion Sources are able to feed accelerators with intense currents of highly charged ions. In ECRIS a high density-high temperature plasma is generated by means of the Electron Cyclotron Resonance Heating inside a B-min, MHD stable trap. The state of the art about the principal heating mechanisms will be given. The paper will specially discuss the most critical and still open issues concerning the influence of the magnetic field and of the RF frequency on the plasma heating, as well as the impact of possible non-linear pumping wave-to-plasma interactions. The contribution of INFN-LNS will be specifically underlined. A short review on the future perspectives for the design of new generation ion sources will be given in conclusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 30-cm diameter argon ion source

A 30 cm diameter argon ion source was evaluated. Ion source beam currents up to 4a were extracted with ion energies ranging from 0.2 to 1.5 KeV. An ion optics scaling relation was developed for predicting ion beam extraction capability as a function of total extraction voltage, gas type, and screen grid open area. Ignition and emission characteristics of several hollow cathode geometries were assessed for purposes of defining discharge chamber and neutralizer cathodes. Also presented are ion beam profile characteristics which exhibit broad beam capability well suited for ion beam sputtering applications.

Sovey, J. S.↗

A 30-cm diameter argon ion source

A 30-cm diameter argon ion source was evaluated. Ion source beam currents up to 4A were extracted with ion energies ranging from 0.2 to 1.5 KeV. An ion optics scaling relation was developed for predicting ion beam extraction capability as a function of total extraction voltage, gas type and screen grid open area. Ignition and emission characteristics of several hollow cathode geometries were assessed for purposes of defining discharge chamber and neutralizer cathodes. Also presented are ion beam profile characteristics which exhibit broad beam capability well suited for ion beam sputtering applications.

Sovey, J. S.↗

Field Ion Source Development for Neutron Generators

An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption ({approx}20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with {approx}10,000 tip arrays have achieved deuterium ion currents of {approx}50 nA. Neutron production by field ionization has yielded {approx}10{sup 2} n/s from {approx}1 mm{sup 2} of array area using the deuterium-deuterium fusion reaction at 90 kV.

36 MATERIALS SCIENCE↗