At least 253 records · Page 14

Jefferson Lab: Present and Future

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab (JLab) comprise a unique facility for nuclear physics research whose upgrade is presently underway, with completion expected in 2017. The upgraded facility will accelerate electron beams to 11 GeV for experiments in the existing Halls A, B and C. In addition, a 12 GeV beam can be provided to a new experimental hall, Hall D, to generate a 9 GeV tagged photon beam. This upgrade will enable a new experimental program with substantial discovery potential to address important topics in hadronic, nuclear, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility (EIC).

Rossi, Patrizia↗

Beam position reconstruction for the g2p experiment in Hall A at Jefferson Lab

Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast raster system, a slow raster system was installed. We found that before and during the experiment, these new devices were tested and debugged, and their performance was also evaluated. In order to achieve the required accuracy (1-2 mm in position and 1-2 mrad in angle at the target location), the data of the BPMs and harps were carefully analyzed, as well as reconstructing the beam position and angle event by event at the target location. Finally, the calculated beam position will be used in the data analysis to accurately determine the kinematics for each event.

43 PARTICLE ACCELERATORS↗

Beam results for the new super-conducting booster at Jefferson Lab

The performance results of a new super-conducting booster for the CEBAF injector at Jefferson Lab, could be of interest for other similar electron injectors. A recent addition of this new booster has provided us the ability to achieve a more adiabatic acceleration and therefore an improvement to the beam dynamics and beam brightness. It has also simplified the design and operation of the section of the injector responsible for accelerating the electron beam from a few hundred keV to several MeV (typically 6.7 MeV). The addition of the new booster was part of an upgrade to the CEBAF injector to improve the beam quality for future physics experiments with high sensitivity to beam quality. The booster consists of two cavities: a 2-cell cavity followed by a 7-cell cavity. This combination allows for a wide range of input electron beam energies, from 130 keV to more than 300 keV. In fact, during the last year, the booster was successfully operated with 140,180, and 200 keV input beam energies as the electron gun was being upgraded. This paper describes the new booster, presents beam optics data results from different beam studies, commissioning, and the physics quality beam operation.

Accelerator Physics↗

Cavity Processing and Testing Activities at Jefferson Lab for LCLS-II Production

Cryomodule production for LCLS-II is well underway at Jefferson Lab. This paper explains the process flow for production cavities, from being received at the Test Lab to being assembled onto cavity strings. Taking our facility and infrastructure into consideration, process optimization and process control are implemented to ensure high quality products.

Davis, Giles↗

Gluonic Excitations and Experimental Hall-D at Jefferson Lab

A new tagged photon beam facility is being constructed in experimental Hall-D at Jefferson Lab as a part of the 12 GeV upgrade program. The 9 GeV linearly-polarized photon beam will be produced via coherent Bremsstrahlung using the CEBAF electron beam, incident on a diamond radiator. The GlueX experiment in Hall-D will use this photon beam to search for and study the pattern of gluonic excitations in the meson spectrum produced through photoproduction reactions with a liquid hydrogen target. Recent lattice QCD calculations predict a rich spectrum of hybrid mesons, that are formed by exciting the gluonic field that couples the quarks. A subset of these hybrid mesons are predicted to have exotic quantum numbers which cannot be formed from a simple qq^- pair, and thus provide an ideal laboratory for testing QCD in the confinement regime. In these proceedings the status of the construction and installation of the GlueX detector will be presented, in addition to simulation results for some reactions of interest in hybrid meson searches.

Stevens, Justin↗

Nucleon spin structure studies at Jefferson Lab

We report on the low and moderate $Q^2$ nucleon spin structure measurements done at Jefferson Lab, examining specifically the inclusive program. We discuss what the data teach us about quark confinement and the emergence of the effective hadronic degrees of freedom from the fundamental partonic ones. We show how this experimental program has reached its goal by providing a precise mapping at low, intermediate and moderately high $Q^2$ which has resulted in many progress, e.g. with Chiral Perturbation Theory. Another example of a recent advance imputable to the JLab spin data is the improved understanding of $\alpha_s$ at low energy, which allowed Light--Front Holographic QCD, an approximation to non-perturbative QCD, to derive the hadron spectrum from $\Lambda_s$.

Deur, Alexandre↗

Jefferson Lab Science: Present and Future

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab comprise a unique facility for experimental nuclear physics. Furthermore, this facility is presently being upgraded, which will enable a new experimental program with substantial discovery potential to address important topics in nuclear, hadronic, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility.

43 PARTICLE ACCELERATORS↗

Production of Charmonium at Threshold in Hall A and C at Jefferson Lab

Here, we describe in this paper two approved experiments in Hall A and Hall C at Jefferson Lab that will investigate the pure gluonic component of the strong interaction of Quantum ChromoDynamics by measuring the elastic J/ψ electro and photo-production cross section in the threshold region as well as explore the nature of the recently discovered LHCb charmed pentaquarks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The design and performance of the electromagnetic calorimeters in Hall C at Jefferson Lab

The design and performance of the electromagnetic calorimeters in the magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers, construction information and comparisons of simulated and experimental results are presented. The design and simulated performance for a new calorimeter to be used in the new SHMS spectrometer is also presented. We have developed and constructed electromagnetic calorimeters from TF-1 type lead-glass blocks for the HMS and SOS magnetic spectrometers at JLab Hall C. The HMS/SOS calorimeters are of identical design and construction except for their total size. Blocks of dimension 10 cm × 10 cm × 70 cm are arranged in four planes and stacked 13 and 11 blocks high in the HMS and SOS respectively. The energy resolution of these calorimeters is better than 6%/√E, and pion/electron (π/e) separation of about 100:1 has been achieved in energy range 1–5 GeV. Good agreement has been observed between the experimental and GEANT4 simulated energy resolutions. The HMS/SOS calorimeters have been used nearly in all Hall C experiments, providing good energy resolution and a high pion suppression factor. No significant deterioration in their performance has been observed in the course of use since 1994. For the SHMS spectrometer, presently under construction, details on the calorimeter design and accompanying GEANT4 simulation efforts are given. A Preshower+Shower design was selected as the most cost-effective among several design choices. The preshower will consist of a layer of 28 modules with TF-1 type lead glass radiators, stacked in two columns. The shower part will consist of 224 modules with F-101 type lead glass radiators, stacked in a “fly's eye” configuration of 14 columns and 16 rows. The active area of 120 × 130 cm(2) will encompass the beam envelope at the calorimeter. The anticipated performance of the new calorimeter is simulated over the full momentum range of the SHMS, predicting resolution and yields similar to the HMS calorimeter. Good electron/hadron separation can be achieved by using energy deposition in the Preshower along with total energy deposition in the calorimeter. In this case the PID capability is similar to or better than that attainable with HMS calorimeter, with a pion suppression factor of a few hundreds predicted for 99% electron detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quench-Back Management for Fast Decaying Currents in SHMS Superconducting Magnets at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) of Hall C, part of the 12-GeV upgrade at Jefferson Lab, was successfully commissioned in 2017. Early operation demonstrated that fast current dumps decays of the SHMS Q2/Q3 and dipole superconducting magnets triggered quenches, causing some level of operational difficulty. Tests and detailed assessments suggest that nonquench induced fast current decay could result in substantial ac loss in the conductor and subsequently trigger a quench-back effect. The OPERA/ELECTRA software package was used to calculate the amount of heat deposited in the copper stabilizer from a fast current decay. The resistances of external energy dump resistors were lowered to slow the fast dumping of the magnet's current to reduce or eliminate the quench-back effect. A worst-case adiabatic quench scenario was analyzed, assuming no external dump resistor and no liquid helium surrounding the coil, to ensure the safety of the magnets. The stress levels in the coil imposed by winding, collaring preload, Lorentz force, and temperature gradient during a quench were also examined. The Tsai-Wu material failure criterion was used to determine the acceptable combined stress level. Linear orthotropic analysis of the coil indicates that the magnets can be operated safely with appropriately sized dump resistors. Fast dump tests with the modified dump resistors have been planned to verify the performance and suitability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nucleon structure at Jefferson Lab: from two dimensions to three dimensions

We review very briefly a few recent highlight results from Jefferson Lab concerning nucleon Form Factors and Generalized Parton Distributions for which data with unprecedented precision and phase space coverage have be obtained these past few years. Along with new theoretical developements, these data allow to make some nucleon imaging in terms of partonic degrees of freedom in both momentum and space dimensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Jefferson Lab 12 GeV Science Program

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab are presently being upgraded, which will enable a new experimental program with substantial discovery potential to address important topics in nuclear, hadronic, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility.

McKeown, R. D.↗

Future Plans at Jefferson Lab: 12 GeV CEBAF Upgrade and Electron-Ion Collider (ELIC)

The 12 GeV CEBAF Upgrade at Jefferson Lab will greatly expand the scientific capabilities for nuclear physics. The scope and status of the construction project as well as the key science motivations are presented. Beyond 12 GeV, a compelling scientific case is developing for an electron ion collider to address fundamental questions in hadronic physics which complement the definitive study of the valence region possible at the 12 GeV facility. A CEBAF-based collider of 9 GeV electrons/positrons and 225 GeV ions, known as ELIC, is envisioned to meet this science need.

Lung, Allison↗

A SYNCHRONIZED FIR/VUV LIGHT SOURCE AT JEFFERSON LAB

We describe a dual free-electron laser (FEL) configuration on the UV Demo FEL at Jefferson Lab that allows simultaneous lasing at FIR/THz and UV wavelengths. The FIR/THz source would be an FEL oscillator with a short wiggler providing nearly diffraction-limited pulses with pulse energy exceeding 50 microJoules. The FIR source would use the exhaust beam from a UVFEL. The coherent harmonics in the VUV from the UVFEL are out-coupled through a hole. The FIR source uses a shorter resonator with either hole or edge coupling to provide very high power FIR pulses. Simulations indicate excel-lent spectral brightness in the FIR region with over 100 W/cm-1 output.

43 PARTICLE ACCELERATORS↗

Spectrometer optics studies and target development for the 208Pb(e,e'p) experiment in Hall A at Jefferson Lab

The reactions 208Pb(e, e0p)207Tl and 209Bi(e, e0p)208Pb have recently been measured at Jefferson Lab using the high resolution spectrometers of Hall A. Monte Carlo simulations of these reactions showed that with a missing energy resolution of 1 MeV, spectrum fitting techniques could extract the cross sections for the states of 207Tl up to 3.5 MeV excitation. Extensive spectrometer optics studies were required to attempt to achieve the requisite missing energy resolution. In addition, the low melting temperature of the heavy metal targets required rastering the electron beam spot on the target and a special target holder to be employed. The measurement was possible because of the unique electron beam characteristics of CEBAF, the high resolution spectrometers of Hall A and the use of a novel target design which allowed for up to 80 ?A of beam on target. The experimental challenges and procedures will be discussed.

Urciuoli, Guido↗

Hadronic Physics at Jefferson Lab

I describe some of the lattice QCD work in support of the hadronic physics program at Jefferson Lab. In particular, there is a strong emphasis on the determination of the excited state hadron spectrum, as well as determining the spin content of nucleons and other hadrons.

43 PARTICLE ACCELERATORS↗

A Beamdump facility at Jefferson Lab

The potential of the intense secondary muon, neutrino, and (hypothetical) light dark matter beams at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) is explored. These are produced in the high-power dumps with high-current electron beams. Light dark matter searches with the approved Beam Dump eXperiment (BDX) are driving the realization of a new underground vault behind Hall A that could be extended to a Beamdump Facility with little additional installations. High-energy muons created via the Bethe–Heitler process uniquely do not proceed through the more common pion production and decay channels. Several possible muon physics applications are highlighted. Neutrino detector technologies and experiments suitable for a beamdump facility are outlined.

Accelerator Physics↗

Update of High Resolution (e,e'K^+) Hypernuclear Spectroscopy at Jefferson Lab's Hall A

Updated results of the experiment E94-107 hypernuclear spectroscopy in Hall A of the Thomas Jefferson National Accelerator Facility (Jefferson Lab), are presented. The experiment provides high resolution spectra of excitation energy for 12B_\Lambda, 16N_\Lambda, and 9Li_\Lambda hypernuclei obtained by electroproduction of strangeness. A new theoretical calculation for 12B_\Lambda, final results for 16N_\Lambda, and discussion of the preliminary results of 9Li_\Lambda are reported.

43 PARTICLE ACCELERATORS↗