Search NASA⌕ Search

SEARCH · Search NASA

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Production of Charmonium at Threshold in Hall A and C at Jefferson Lab

Here, we describe in this paper two approved experiments in Hall A and Hall C at Jefferson Lab that will investigate the pure gluonic component of the strong interaction of Quantum ChromoDynamics by measuring the elastic J/ψ electro and photo-production cross section in the threshold region as well as explore the nature of the recently discovered LHCb charmed pentaquarks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The design and performance of the electromagnetic calorimeters in Hall C at Jefferson Lab

The design and performance of the electromagnetic calorimeters in the magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers, construction information and comparisons of simulated and experimental results are presented. The design and simulated performance for a new calorimeter to be used in the new SHMS spectrometer is also presented. We have developed and constructed electromagnetic calorimeters from TF-1 type lead-glass blocks for the HMS and SOS magnetic spectrometers at JLab Hall C. The HMS/SOS calorimeters are of identical design and construction except for their total size. Blocks of dimension 10 cm × 10 cm × 70 cm are arranged in four planes and stacked 13 and 11 blocks high in the HMS and SOS respectively. The energy resolution of these calorimeters is better than 6%/√E, and pion/electron (π/e) separation of about 100:1 has been achieved in energy range 1–5 GeV. Good agreement has been observed between the experimental and GEANT4 simulated energy resolutions. The HMS/SOS calorimeters have been used nearly in all Hall C experiments, providing good energy resolution and a high pion suppression factor. No significant deterioration in their performance has been observed in the course of use since 1994. For the SHMS spectrometer, presently under construction, details on the calorimeter design and accompanying GEANT4 simulation efforts are given. A Preshower+Shower design was selected as the most cost-effective among several design choices. The preshower will consist of a layer of 28 modules with TF-1 type lead glass radiators, stacked in two columns. The shower part will consist of 224 modules with F-101 type lead glass radiators, stacked in a “fly's eye” configuration of 14 columns and 16 rows. The active area of 120 × 130 cm(2) will encompass the beam envelope at the calorimeter. The anticipated performance of the new calorimeter is simulated over the full momentum range of the SHMS, predicting resolution and yields similar to the HMS calorimeter. Good electron/hadron separation can be achieved by using energy deposition in the Preshower along with total energy deposition in the calorimeter. In this case the PID capability is similar to or better than that attainable with HMS calorimeter, with a pion suppression factor of a few hundreds predicted for 99% electron detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quench-Back Management for Fast Decaying Currents in SHMS Superconducting Magnets at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) of Hall C, part of the 12-GeV upgrade at Jefferson Lab, was successfully commissioned in 2017. Early operation demonstrated that fast current dumps decays of the SHMS Q2/Q3 and dipole superconducting magnets triggered quenches, causing some level of operational difficulty. Tests and detailed assessments suggest that nonquench induced fast current decay could result in substantial ac loss in the conductor and subsequently trigger a quench-back effect. The OPERA/ELECTRA software package was used to calculate the amount of heat deposited in the copper stabilizer from a fast current decay. The resistances of external energy dump resistors were lowered to slow the fast dumping of the magnet's current to reduce or eliminate the quench-back effect. A worst-case adiabatic quench scenario was analyzed, assuming no external dump resistor and no liquid helium surrounding the coil, to ensure the safety of the magnets. The stress levels in the coil imposed by winding, collaring preload, Lorentz force, and temperature gradient during a quench were also examined. The Tsai-Wu material failure criterion was used to determine the acceptable combined stress level. Linear orthotropic analysis of the coil indicates that the magnets can be operated safely with appropriately sized dump resistors. Fast dump tests with the modified dump resistors have been planned to verify the performance and suitability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nucleon structure at Jefferson Lab: from two dimensions to three dimensions

We review very briefly a few recent highlight results from Jefferson Lab concerning nucleon Form Factors and Generalized Parton Distributions for which data with unprecedented precision and phase space coverage have be obtained these past few years. Along with new theoretical developements, these data allow to make some nucleon imaging in terms of partonic degrees of freedom in both momentum and space dimensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Jefferson Lab 12 GeV Science Program

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab are presently being upgraded, which will enable a new experimental program with substantial discovery potential to address important topics in nuclear, hadronic, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility.

McKeown, R. D.↗

Future Plans at Jefferson Lab: 12 GeV CEBAF Upgrade and Electron-Ion Collider (ELIC)

The 12 GeV CEBAF Upgrade at Jefferson Lab will greatly expand the scientific capabilities for nuclear physics. The scope and status of the construction project as well as the key science motivations are presented. Beyond 12 GeV, a compelling scientific case is developing for an electron ion collider to address fundamental questions in hadronic physics which complement the definitive study of the valence region possible at the 12 GeV facility. A CEBAF-based collider of 9 GeV electrons/positrons and 225 GeV ions, known as ELIC, is envisioned to meet this science need.

Lung, Allison↗

A SYNCHRONIZED FIR/VUV LIGHT SOURCE AT JEFFERSON LAB

We describe a dual free-electron laser (FEL) configuration on the UV Demo FEL at Jefferson Lab that allows simultaneous lasing at FIR/THz and UV wavelengths. The FIR/THz source would be an FEL oscillator with a short wiggler providing nearly diffraction-limited pulses with pulse energy exceeding 50 microJoules. The FIR source would use the exhaust beam from a UVFEL. The coherent harmonics in the VUV from the UVFEL are out-coupled through a hole. The FIR source uses a shorter resonator with either hole or edge coupling to provide very high power FIR pulses. Simulations indicate excel-lent spectral brightness in the FIR region with over 100 W/cm-1 output.

43 PARTICLE ACCELERATORS↗

Hadronic Physics at Jefferson Lab

I describe some of the lattice QCD work in support of the hadronic physics program at Jefferson Lab. In particular, there is a strong emphasis on the determination of the excited state hadron spectrum, as well as determining the spin content of nucleons and other hadrons.

43 PARTICLE ACCELERATORS↗

A Beamdump facility at Jefferson Lab

The potential of the intense secondary muon, neutrino, and (hypothetical) light dark matter beams at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) is explored. These are produced in the high-power dumps with high-current electron beams. Light dark matter searches with the approved Beam Dump eXperiment (BDX) are driving the realization of a new underground vault behind Hall A that could be extended to a Beamdump Facility with little additional installations. High-energy muons created via the Bethe–Heitler process uniquely do not proceed through the more common pion production and decay channels. Several possible muon physics applications are highlighted. Neutrino detector technologies and experiments suitable for a beamdump facility are outlined.

Accelerator Physics↗

Update of High Resolution (e,e'K^+) Hypernuclear Spectroscopy at Jefferson Lab's Hall A

Updated results of the experiment E94-107 hypernuclear spectroscopy in Hall A of the Thomas Jefferson National Accelerator Facility (Jefferson Lab), are presented. The experiment provides high resolution spectra of excitation energy for 12B_\Lambda, 16N_\Lambda, and 9Li_\Lambda hypernuclei obtained by electroproduction of strangeness. A new theoretical calculation for 12B_\Lambda, final results for 16N_\Lambda, and discussion of the preliminary results of 9Li_\Lambda are reported.

43 PARTICLE ACCELERATORS↗

N* Physics with CLAS12 at Jefferson Lab

Nucleons are the most fundamental bound three-body systems in Nature. With the CLAS12 spectrometer at Jefferson Lab, the spectrum and the structure of nucleon resonances is explored. This includes studies of exclusive piN, pi+pi-p, KLambda, and KSigma electroproduction reactions and the evolution of the electrocouplings of resonances with photon virtuality Q^2. Such type of studies with CLAS have revealed a complex interplay between a core of dressed quarks and an external meson-baryon cloud inside of the excited nucleon states. With CLAS12, also measurements of N -> N* transitions in the DIS region have been performed, addressing the three-dimensional structure of nucleon resonances through their transition GPDs (generalized parton distributions). In the future, the increase of the CEBAF energy and the upgrade of the CLAS12 spectrometer to study exclusive electroproduction channels at higher luminosities and photon virtualities will offer a unique opportunity to study the nucleon excitation mechanisms.

Achenbach, Patrick↗

The Jefferson Lab VUV-FEL at 10 eV and above

We will present details of the vacuum ultraviolet performance of the Jefferson Lab Free Electron Laser. The JLab FEL is oscillator-based [1] and uses a superconducting energy recovered linac for CW RF operation at up to 75 MHz. Lasing at a fundamental wavelength of 372 nm, the third harmonic is at 124 nm, corresponding to a photon energy of 10 eV. The energy per pulse in the fundamental is 20 microJoules, which at 9 MHz yields an average power of 180 Watts. The pulses have a FWHM of order 300 fs, which essentially determines the optical bandwidth. The third harmonic, which is a 0.1 ? 1% fraction of this, is considerably brighter than any other source in the region. Further, being an FEL, there is a wide range of tunability in the 1 eV to 15 eV range. Additional reach is possible with increased electron beam energy, and some options will be discussed in the talk. We acknowledge funding from ONR, AFRL and DOE-BES under contract AC05-060R23177. [1]. S. Benson et al. Nucl. Instrum. Methods A582, 14-17 (2007).

Williams, Gwyn↗

AI-Optimized Polarization at Jefferson Lab

The AI-Optimized Polarization project seeks to develop experimental control applications for polarized targets and beams at Jefferson Lab using AI/ML. This paper will focus on two ongoing efforts involving a cryogenic polarized target and a linearly-polarized photon beam. Firstly, cryogenic targets, such as those used in Halls B and C (and approved for Hall D), are complex systems that are sensitive to a number of factors, including the temperature, beam currents, and the microwave and NMR apparatus. Secondly, the Hall D photon beam polarization depends on the optimal orientation of a diamond radiator, which produces coherent bremsstrahlung radiation from the electron beam incident upon it. Manual operation of both systems is tedious and error prone; implementing well-designed, interpretable control systems that incorporate AI is expected to lead to improved real-time polarization. AI optimization of nuclear physics experiments will lead, not just to cost-savings, but also to more efficient and higher-quality data, and this project will help to lay the foundation for future autonomous experiments.

Moran, Patrick [College of William and Mary, Willi↗

Density measurement through elastic electron scattering with a gaseous target at the Jefferson Lab

We report the density measurement through e-3He elastic scattering with a 1.23 GeV electron beam in Jefferson Lab experiment E06-010. The extracted 3He density is (9.26 plus-minus 0.06) amagats and the N2/3He ratio is (1:49 plus-minus 0:08)%. In addition, these results are consistent with the deduced target densities based on pressure broadening measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

USING E-BEAM IRRADIATION BEAMLINE AT JEFFERSON LAB TO REMOVE 1,4-DIOXANE AND PFAS IN WASTEWATER

The designed e-beam irradiation beamline [1] at Jefferson Lab has been commissioned and applied to study the degradation removal of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater by collaborating with Hampton Roads Sanitation District (HRSD), treating wastewater in southeast Virginia. The absorbed dose and dose distribution in the entire sample were achieved innovatively using Monte-Carlo simulations that were calibrated with opti-chromic dosimeter rods directly exposed to the e-beam. This research could be a stepstone to the future MW compact SRF accelerator [2] for wastewater remediation.

Li, X.↗

Spectroscopic Study of L Hypernuclei with Electron Beams at Jefferson Lab

The missing mass spectroscopy of L hypernuclei with the (e, e'K^+) reaction was started from 2000 at Jefferson Lab. In this fifteen years, various hypernuclei (A = 7 - 52) including hyperon (L, S^0) productions have been studied with newly developed experimental techniques. The (e, e'K^+) reaction spectroscopy of L hypernuclei features its capability of absolute missing mass calibration and production of new species of hypernuclei which are the isospin partners of well studied hypernuclei by (K^-, pi-) and (pi^+, K^+) reactions. In this paper, we will review how we established the (e, e'K^+) spectroscopic study of hypernuclei.

Nakamura, Satoshi↗

Qweak: A Precision Standard Model Test at Jefferson Lab

The Qweak collaboration is currently performing the first precision measurement of the proton's neutral weak charge at Jefferson Lab. The Standard Model gives a firm prediction for the weak charge; any deviation from that can be interpreted as new physics beyond the Standard Model. This precision, low energy measurement is sensitive to new physics signatures at energy scales up to 2 TeV. The experiment measures the parity-violating asymmetry in the scattering of longitudinally polarized electrons on the proton at low momentum transfer. An overview of the motivation and experimental approach will be presented, along with an update on the current status.

Pitt, Mark↗