Particle Acceleration and Magnetic Field Generation in Electron-Positron Relativistic Shocks

Shock acceleration is a ubiquitous phenomenon in astrophysical plasmas. Plasma waves and their associated instabilities (e.g., Buneman, Weibel, and other two-stream instabilities) created in collisionless shocks are responsible for particle (electron, positron, and ion) acceleration. Using a three-dimensional relativistic electromagnetic particle (REMP) code, we have investigated particle acceleration associated with a relativistic electron-positron jet front propagating into an ambient electron-positron plasma with and without initial magnetic fields. We find small differences in the results for no ambient and modest ambient magnetic fields. New simulations show that the Weibel instability created in the collisionless shock front accelerates jet and ambient particles both perpendicular and parallel to the jet propagation direction. Furthermore, the nonlinear fluctuation amplitudes of densities, currents, and electric and magnetic fields in the electron-positron shock are larger than those found in the electron-ion shock studied in a previous paper at a comparable simulation time. This comes from the fact that both electrons and positrons contribute to generation of the Weibel instability. In addition, we have performed simulations with different electron skin depths. We find that growth times scale inversely with the plasma frequency, and the sizes of structures created by tine Weibel instability scale proportionally to the electron skin depth. This is the expected result and indicates that the simulations have sufficient grid resolution. While some Fermi acceleration may occur at the jet front, the majority of electron and positron acceleration takes place behind the jet front and cannot be characterized as Fermi acceleration. The simulation results show that the Weibel instability is responsible for generating and amplifying nonuniform, small-scale magnetic fields, which contribute to the electron s (positron s) transverse deflection behind the jet head. This small- scale magnetic field structure is appropriate to the generation of "jitter" radiation from deflected electrons (positrons) as opposed to synchrotron radiation. The jitter radiation has different properties than synchrotron radiation calculated assuming a uniform magnetic field. The jitter radiation resulting from small-scale magnetic field structures may be important for understanding the complex time structure and spectral evolution observed in gamma-ray bursts or other astrophysical sources containing relativistic jets and relativistic collisionless shocks.

Nishikawa, K.-I.↗

A Numerical Theory for Impedance Education in Three-Dimensional Normal Incidence Tubes

A method for educing the locally-reacting acoustic impedance of a test sample mounted in a 3-D normal incidence impedance tube is presented and validated. The unique feature of the method is that the excitation frequency (or duct geometry) may be such that high-order duct modes may exist. The method educes the impedance, iteratively, by minimizing an objective function consisting of the difference between the measured and numerically computed acoustic pressure at preselected measurement points in the duct. The method is validated on planar and high-order mode sources with data synthesized from exact mode theory. These data are then subjected to random jitter to simulate the effects of measurement uncertainties on the educed impedance spectrum. The primary conclusions of the study are 1) Without random jitter the method is in excellent agreement with that for known impedance samples, and 2) Random jitter that is compatible to that found in a typical experiment has minimal impact on the accuracy of the educed impedance.

Watson, Willie R.↗

Precision Pointing for the Wide-Field Infrared Survey Telescope (WFIRST)

The Wide-Field Infrared Survey Telescope (WFIRST) mission, scheduled for a mid-2020's launch, is currently in its definition phase. The mission is designed to investigate essential questions in the areas of dark energy, exoplanets, and infrared astrophysics. WFIRST will use a 2.4-meter primary telescope (same size as the Hubble Space Telescope's primary mirror) and two instruments: the Wide Field Instrument (WFI) and the Coronagraph Instrument (CGI). In order to ad-dress the critical science requirements, the WFIRST mission will conduct large-scale surveys of the infrared sky, requiring both agility and precision pointing (11.6 milli-arcsec stability, 14 milli-arcsec jitter). This paper describes some of the challenges this mission profile presents to the GNC subsystem, and some of the design elements chosen to accommodate those challenges. The high-galactic-latitude survey is characterized by 3-minute observations separated by slews ranging from 0.025 deg to 0.8 deg. The need for observation efficiency drives the slew and settle process to be as rapid as possible. A description of the shaped slew profile chosen to minimize excitation of structural oscillation, and the handoff from star tracker-gyro control to fine guidance sensor control is detailed. Also presented is the fine guidance sensor (FGS), which is integral with the primary instrument (WFI). The FGS is capable of tracking up to 18 guide stars, enabling robust FGS acquisition and precision pointing. To avoid excitation of observatory structural jitter, reaction wheel speeds are operationally maintained within set limits. In addition, the wheel balance law is designed to maintain 1-Hz separation between the wheel speeds to avoid reinforcing jitter excitation at any particular frequency. The wheel balance law and operational implications are described. Finally, the candidate GNC hardware suite needed to meet the requirements of the mission is presented.

Stoneking, Eric↗

Precision Pointing for the Wide-Field Infrared Survey Telescope(WFIRST)

The Wide-Field Infrared Survey Telescope (WFIRST) mission, scheduled for a mid-2020's launch, is currently in its definition phase. The mission is designed to investigate essential questions in the areas of dark energy, exoplanets, and infrared astrophysics. WFIRST will use a 2.4-meter primary telescope (same size as the Hubble Space Telescope's primary mirror) and two instruments: the Wide Field Instrument (WFI) and the Coronagraph Instrument (CGI). In order to address the critical science requirements, the WFIRST mission will conduct large-scale surveys of the infrared sky, requiring both agility and precision pointing (11.6 milli-arcsec stability, 14 milli-arcsec jitter). This paper describes some of the challenges this mission profile presents to the Guidance, Navigation, and Control (GNC) subsystem, and some of the design elements chosen to accommodate those challenges. The high-galactic-latitude survey is characterized by 3-minute observations separated by slews ranging from 0.025 deg to 0.8 deg. The need for observation efficiency drives the slew and settle process to be as rapid as possible. A description of the shaped slew profile chosen to minimize excitation of structural oscillation, and the handoff from star tracker-gyro control to fine guidance sensor control is detailed. Also presented is the fine guidance sensor (FGS), which is integral with the primary instrument (WFI). The FGS is capable of tracking up to 18 guide stars, enabling robust FGS acquisition and precision pointing. To avoid excitation of observatory structural jitter, reaction wheel speeds are operationally maintained within set limits. In addition, the wheel balance law is designed to maintain 1-Hz separation between the wheel speeds to avoid reinforcing jitter excitation at any particular frequency. The wheel balance law and operational implications are described. Finally, the candidate GNC hardware suite needed to meet the requirements of the mission is presented.

Stoneking, Eric T.↗

Results from the ASTERIA CubeSat Extended Mission Experiments

Over the past two years, JPL has used the ASTERIA (Arcsecond Space Telescope Enabling Research In Astrophysics) CubeSat as an in-flight test platform during extended missions. ASTERIA successfully completed its prime mission in early 2018, and continued to operate in low Earth orbit (LEO) for an additional twenty months. This paper describes demonstrations that were performed on the spacecraft and on the ground-based testbed during the extended mission. These demonstrations fall into three categories: Autonomy technology maturation, hardware characterization, and science discovery. Autonomy technology maturation supported three development efforts. The first shifted the spacecraft commanding paradigm from time-based sequences to Task Networks (tasknets), which allow simpler commanding and more robust onboard execution. The second demonstrated onboard orbit determination in Low Earth Orbit (LEO) without GPS. This activity used a fully-independent means of spacecraft orbit determination for Earth orbiters using only passive imaging. The third technology provided in situ hardware health state estimation using a model-based reasoning technique. These three technologies were demonstrated either in flight or on the testbed individually, and then were combined to demonstrate the capability to perform autonomous navigation on board without ground intervention, even in the presence of anomalies. Hardware characterization involved both onboard and ground-based activities. On board, nonstandard attitude control modes were commanded to characterize the spacecraft pointing jitter as a function of target brightness, reaction wheel speed, controller gain, and the number of guide stars. The results provide insights into the contribution of jitter to the ASTERIA photometry and inform the feasibility of future astrophysics small satellite missions for which jitter control is an enabling technology. On the ground, the ASTERIA Operations Team coordinated with Amazon Web Services (AWS) to configure their new ground stations to communicate with ASTERIA to prove out their viability. ASTERIA used AWS ground stations for nominal operations for the last four months of the mission. Finally, ASTERIA continued to perform exoplanet science as the spacecraft was well-suited to execute long-term monitoring of stars such as alpha Centauri to search for small transiting planets. The science team also imaged a number of interesting objects including a comet, an asteroid, cities at night, and the moon, and coordinated with other projects on Targets of Opportunity for follow-up confirmations and co-observations. Throughout the prime and the extended missions, the ASTERIA spacecraft proved to be a mighty platform that “will go into history as an innovative milestone.”[1 - Zurbuchen]

Doran, Patrick↗

Application of Micro-thrusters for Space Observatory Precision Attitude Control

This paper describes the results of a NASA investigation into the benefits of micro-thrusters compared to reaction wheels on future observatory-class missions with tight pointing stability requirements. Pointing repeatability and stability (i.e., jitter) requirements are key for space telescope missions of the future. For example, managing jitter is essential to being able to “image” planets orbiting distant stars. Jitter requirements for missions in this class are difficult to meet with current reaction wheel-based architectures. The reaction wheels are typically the largest pointing disturbance on the spacecraft. Disturbances from reaction wheels can be mitigated, typically by mechanically isolating the wheels, which imposes system complexity and cost. Thrusters capable of thrust forces in the micronewton (μN) range (referred to as micro-thrusters or micronewton thrusters) have been developed to support the Laser Interferometer Space Antenna (LISA) mission, which requires drag-free control to place a test mass in near-perfect free-fall Beyond the drag-free control application, micro-thrusters could be used as a substitute for reaction wheels or as a supplement to wheels for fine pointing control. Used in this fashion, micro-thrusters have potential for reducing the cost and technical risks of achieving demanding pointing stability performance on observatory-class missions.

Chiang, Richard Y.↗

A 1.2-V 6-GHz Dual-Path Charge-Pump PLL Frequency Synthesizer for Quantum Control and Readout in CMOS 65-nm Process

This paper presents a low jitter dual-path chargepump phase locked loop (PLL) synthesizer in a CMOS 65-nm process for quantum readout applications. The PLL incorporates a programmable dual chargepump and a loop filter with both proportional and integral paths that can be driven independently providing flexible control of the loop bandwidth to achieve low jitter performance. The design is implemented at 300 K and critical blocks like voltage-controlled oscillator (VCO) and chargepump (CP) are analyzed at 77 K based on the characterized results. The LC-VCO is realized with the class-C NMOS only architecture with 5-bit coarse control and quadrature signals are generated with poly phase filter. The VCO is designed with the tuning range of 1 GHz around the center frequency of 6 GHz with Phase Noise of -123 dBc/Hz and -132 dBc/Hz at 1MHz offset at 300 K and 77 K temperature. The simulated PLL rms jitter is 125 fs at 6 GHz with a power consumption of 8 mW at the 1.2 V power supply.

47 OTHER INSTRUMENTATION↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clocking Auger electrons

Intense X-ray free-electron lasers (XFELs) can rapidly excite matter, leaving it in inherently unstable states that decay on femtosecond timescales. The relaxation occurs primarily via Auger emission, so excited-state observations are constrained by Auger decay. In situ measurement of this process is therefore crucial, yet it has thus far remained elusive in XFELs owing to inherent timing and phase jitter, which can be orders of magnitude larger than the timescale of Auger decay. Here we develop an approach termed ‘self-referenced attosecond streaking’ that provides subfemtosecond resolution in spite of jitter, enabling time-domain measurement of the delay between photoemission and Auger emission in atomic neon excited by intense, femtosecond pulses from an XFEL. FUrthermore, using a fully quantum-mechanical description that treats the ionization, core-hole formation and Auger emission as a single process, the observed delay yields an Auger decay lifetime of \(2.2_{ - 0.3}^{ + 0.2}\) fs for the KLL decay channel.

47 OTHER INSTRUMENTATION↗

Time-resolved RIXS experiment with pulse-by-pulse parallel readout data collection using X-ray free electron laser

Abstract Time-resolved resonant inelastic X-ray scattering (RIXS) is one of the developing techniques enabled by the advent of X-ray free electron laser (FEL). It is important to evaluate how the FEL jitter, which is inherent in the self-amplified spontaneous emission process, influences the RIXS measurement. Here, we use a microchannel plate (MCP) based Timepix soft X-ray detector to conduct a time-resolved RIXS measurement at the Ti L 3 -edge on a charge-density-wave material TiSe 2 . The fast parallel Timepix readout and single photon sensitivity enable pulse-by-pulse data acquisition and analysis. Due to the FEL jitter, low detection efficiency of spectrometer, and low quantum yield of RIXS process, we find that less than 2% of the X-ray FEL pulses produce signals, preventing acquiring sufficient data statistics while maintaining temporal and energy resolution in this measurement. These limitations can be mitigated by using future X-ray FELs with high repetition rates, approaching MHz such as the European XFEL in Germany and LCLS-II in the USA, as well as by utilizing advanced detectors, such as the prototype used in this study.

36 MATERIALS SCIENCE↗

Measurement of femtosecond dynamics of ultrafast electron beams through terahertz compression and time-stamping

Visualizing ultrafast dynamics at the atomic scale requires time-resolved characterization with femtosecond temporal resolution. For fully relativistic electron bunch probes, existing techniques for single-shot ultrafast electron diffraction (UED) are limited by the achievable electron probe bunch length, charge, and timing jitter. We present the first experimental demonstration of dual-fed THz-driven compression and time-stamping that enables electron probes with improved temporal resolution. This technique utilizes two counter-propagating quasi-single-cycle THz pulses generated from two OH-1 organic crystals coupled into an optimized THz compressor structure. We demonstrate electron bunch compression and time-of-arrival jitter suppression by a factor of 3 paving the way toward unique opportunities for UED time-resolved measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Slicing Newton spheres with a two-camera 3D imaging system

We demonstrate a simple approach to achieve three-dimensional ion momentum imaging. The method employs two complementary metal–oxide–semiconductor cameras in addition to a standard microchannel plates/phosphor screen imaging detector. The two cameras are timed to measure the decay of luminescence excited by ion hits to extract the time of flight. The achieved time resolution is better than 10 ns, which is mainly limited by camera jitters. A better than 5 ns resolution can be achieved when the jitter is suppressed.

Chemistry↗

Improved accuracy and robustness of electron density profiles from JET’s X-mode frequency-modulated continuous-wave reflectometers

JET’s frequency-modulated continuous wave (FMCW) reflectometers have been operating well with the current design since 2005, and density profiles have been automatically calculated intershot since then. However, the calculated profiles had long suffered from several shortcomings: poor agreement with other diagnostics, sometimes inappropriately moving radially by several centimeters, elevated levels of radial jitter, and persistent wriggles (strong unphysical oscillations). Here, in this research, several techniques are applied to the reflectometry data analysis, and the shortcomings are significantly improved. Starting with improving the equilibrium reconstruction that estimates the background magnetic field, adding a ripple correction in the reconstructed magnetic field profile, and adding new inner-wall reflection positions estimated through ray-tracing, these changes not only improve the agreement of reconstructed profiles to other diagnostics but also solve density profile wriggles that were present during band transitions. Other smaller but also persistent wriggles were also suppressed by applying a localized correction to the measured beat frequency where persistent oscillations are present. Finally, the burst analysis method, as introduced by Varela et al., has been implemented to extract the beat frequency from stacked spectrograms. Due to the strong suppression of spurious reflections, the radial jitter that sometimes would span several centimeters has been strongly reduced. The stacking of spectrograms has also been shown to be very useful for stacking recurring events, like small gas puff modulations, and extracting transport coefficients that would otherwise be below the noise level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lasing dynamics of diode-pumped Yb – Er laser with a passive Q switch exposed to high-power external light

The temporal dynamics of diode-side-pumped Yb – Er laser, with a passive Co{sup 2+} : MgAl{sub 2}O{sub 4} Q switch illuminated by a light beam (total fluence of 0.15 – 0.16 J cm{sup −2}) from a semiconductor pulsed module, is investigated. It is shown that, using this external illumination, one can change the lasing onset delay and the time jitter ΔT{sub gi}. The dependence of ΔT{sub gi} on the interval between the instant of switching the illumination module on and the lasing peak position t{sub i} has a minimum at |t{sub i}| ≈ 10 μs. The decrease in ΔT{sub gi} with a change in |t{sub i}| from 90 to 10 μs indicates that instant of lasing peak occurrence for the Yb – Er laser is partially controlled by the pulse from the highly stable semiconductor module. If |t{sub i}| < 10 μs, the enhanced luminescence fluence in the cavity of Yb – Er laser exceeds 0.16 J cm{sup −2}; the light beam from the module does not affect much the lasing process in the ytterbium – erbium laser; and, as a consequence, the time jitter recovers the initial value. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First test results of the trans-impedance amplifier stage of the ultra-fast HPSoC ASIC

Abstract We present the first results from the HPSoC ASIC designed for readout of Ultra-fast Silicon Detectors. The 4-channel ASIC manufactured in 65 nm CMOS by TSMC has been optimized for 50 μm thick AC-LGAD. The evaluation of the analog front end with β-particles impinging on 3 × 3 AC-LGAD arrays (500 μm pitch, 200 × 200 μm 2 metal) confirms a fast output rise time of 600 ps and good timing performance with a jitter of 45 ps. Further calibration experiments and TCT laser studies indicate some gain limitations that are being investigated and are driving the design of the second-generation pre-amplification stages to reach a jitter of 15 ps.

Instruments & Instrumentation↗