Search NASA⌕ Search

SEARCH · Search NASA

Results for “Joint Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Improving the fatigue resistance of adhesive joints in laminated wood structures

The premature fatigue failure of a laminated wood/epoxy test beam containing a cross section finger joint was the subject of a multi-disciplinary investigation. The primary objectives were to identify the failure mechanisms which occurred during the finger joint test and to provide avenues for general improvements in the design and fabrication of adhesive joints in laminated wood structures.

Laufenberg, Theodore L.↗

An Approach for Performance Assessments of Extravehicular Activity Gloves

The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear‐entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game‐Changing Technology group provided start‐up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of two sets of prototype EVA gloves developed ILC Dover and David Clark Company as compared to the Phase VI. Both companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test subjects representing the design‐to hand anthropometry completed range of motion, grip/pinch strength, dexterity, and fit evaluations for each glove design in pressurized conditions, with and without thermal micrometeoroid garments (TMG) installed. This paper provides a detailed description of hardware and test methodologies used and lessons learned.

Aitchison, Lindsay↗

Benchmarking Evaluation Results for Prototype Extravehicular Activity Gloves

The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game-Changing Technology group provided start-up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of four prototype gloves developed by Flagsuit LLC, Final Frontier Designs, LLC Dover, and David Clark Company as compared to the Phase VI. All of the companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test subjects representing the design ]to hand anthropometry completed range of motion, grip/pinch strength, dexterity, and fit evaluations for each glove design in both the unpressurized and pressurized conditions. This paper provides a comparison of the test results along with a detailed description of hardware and test methodologies used.

Aitchison, Lindsay↗

Investigation of Bolt Preload Relaxation for JWST Thermal Heat Strap Assembly Joints with Aluminum-1100 and Indium Gaskets

Accurately predicting fastener preload relaxation in the James Webb Space Telescope (JWST) heat strap assemblies is essential to insure adequate thermal performance during its mission lifecycle. The mechanisms for preload relaxation in the strap joints include Al-1100 material creep, indium gasket flow-out, and embedment of the joint faying surfaces. This report documents the results from a bolted joint relaxation test, including analysis and curve fitting of the test data for predicting preloads five years after initial torque application. The report also includes the derivation of a preload uncertainty factor enveloping both torque/preload application scatter and expected preload relaxation at the end of mission life.

Joint↗

Investigation of Bolt Preload Relaxation for JWST Thermal Heat Strap Assembly Joints with Aluminum-1100 and Indium Gaskets

Accurately predicting fastener preload relaxation in the James Webb Space Telescope (JWST) heat strap assemblies is essential to insure adequate thermal performance during its mission lifecycle. The mechanisms for preload relaxation in the strap joints include Al-1100 material creep, indium gasket flow-out, and embedment of the joint faying surfaces. This report documents the results from a bolted joint relaxation test, including analysis and curve fitting of the test data for predicting preloads five years after initial torque application. The report also includes the derivation of a preload uncertainty factor enveloping both torque/preload application scatter and expected preload relaxation at the end of mission life.

Preload↗

Bolt Analysis Program

In designing and testing bolted joints there are multiple parameters to be considered and calculations that must be performed to predict the joint behavior. Each different set of parameters may call for a different set of equations. Determining every parameter in each bolted joint is impractical and in many cases impossible. On the other hand, it is much easier to reduce these calculations to a universal set that can be used for all bolted joints. This is the purpose of the Bolt Analysis Program. My project under the Mechanical and Rotating Systems branch of the Engineering Development and Analysis Division was to take the Bolt Analysis Program Version 2.0 and update the program to a modem and user-friendly format. Version 2.0 of the Bolt Analysis Program is a useful program, but lacks the dynamic capabilities that are needed for current applications. Version 2.0 of the Bolt Analysis Program was written in 1993 using the Pascal programming language in a DOS format. This program allows you to input data in a step-by-step format, calculates the data, and then on a final screen displays the input and the output fiom the calculations. Version 2.0 is still applicable for all bolted joint anaiysis, but has updates that are desired. First, the program runs in DOS format. With the applications available today, my mentor decided it would be best to update the program into Excel using Visual Basic for Applications (VBA). This would allow the program to have multiple Graphical User Interfaces (GUI s) while retaining all functions of the previous program. Version 2.0 only allows you to input data in a step-by-step process. If you make a mistake and need to go back, you must run through the entire program before you can return to fix your error. This becomes tedious when needing to change one parameter or test multiple sets of data. In Version 3.0, the program allows you to enter and change data at any time while displaying real-time output data. If you realize an error, it is as simple as scrolling back to your mistake and changing the data. Additional information is included in the original extended abstract.

Travis, Brandon E.↗

Biomechanical Comparison of Anatomic Restoration of the Ulnar Footprint vs Traditional Ulnar Tunnels in Ulnar Collateral Ligament Reconstruction

Background: Current techniques for ulnar collateral ligament (UCL) reconstruction do not reproduce the anatomic ulnar footprint of the UCL. The purpose of this study was to describe a novel UCL reconstruction technique that utilizes proximal-to-distal ulnar bone tunnels to better re-create the anatomy of the UCL and to compare the biomechanical profile at time zero among this technique, the native UCL, and the traditional docking technique. Hypothesis: The biomechanical profile of the anatomic technique is similar to the native UCL and traditional docking technique. Study Design: Controlled laboratory study. Methods: Ten matched cadaveric elbows were potted with the forearm in neutral rotation. The palmaris longus tendon graft was harvested, and bones were sectioned 14 cm proximal and distal to the elbow joint. Specimen testing included (1) native UCL testing performed at 90° of flexion with 0.5 N·m of valgus moment preload, (2) cyclic loading from 0.5 to 5 N·m of valgus moment for 1000 cycles at 1 Hz, and (3) load to failure at 0.2 mm/s. Elbows then underwent UCL reconstruction with 1 elbow of each pair receiving the classic docking technique using either anatomic (proximal to distal) or traditional (anterior to posterior) tunnel locations. Specimen testing was then repeated as described. Results: There were no differences in maximum load at failure between the anatomic and traditional tunnel location techniques (mean ± SD, 34.90 ± 10.65 vs 37.28 ± 14.26 N·m; P = .644) or when including the native UCL (45.83 ± 17.03 N·m; P = .099). Additionally, there were no differences in valgus angle after 1000 cycles across the anatomic technique (4.58°± 1.47°), traditional technique (4.08°± 1.28°), and native UCL (4.07°± 1.99°). The anatomic group and the native UCL had similar valgus angles at failure (24.13°± 5.86° vs 20.13°± 5.70°; P = .083), while the traditional group had a higher valgus angle at failure when compared with the native UCL (24.88°± 6.18° vs 19.44°± 5.86°; P = .015). Conclusion: In this cadaveric model, UCL reconstruction with the docking technique utilizing proximal-to-distal ulnar tunnels better restored the ulnar footprint while providing valgus stability comparable with reconstruction with the docking technique using traditional anterior-to-posterior ulnar tunnel locations. These results suggest that utilization of the anatomic tunnel location in UCL reconstruction has similar biomechanical properties to the traditional method at the time of initial fixation (ie, not accounting for healing after reconstruction in vivo) while keeping the ulnar tunnels farther from the ulnar nerve. Further studies are warranted to determine if an anatomically based UCL reconstruction results in differing outcomes than traditional reconstruction techniques. Clinical Relevance: Current UCL reconstruction techniques do not accurately re-create the ulnar UCL footprint. The UCL is a dynamic constraint to valgus loads at the elbow, and a more anatomic reconstruction may afford more natural joint kinematics. This more anatomic technique performs similarly to the traditional docking technique at time zero, and the results of this study may offer a starting point for future in vivo studies.

Chang, Edward S.↗

Reconstructing the Universe: Testing the Mutual Consistency of the Pantheon and SDSS/eBOSS BAO Data Sets with Gaussian Processes

We test the mutual consistency between the baryon acoustic oscillation measurements from the eBOSS SDSS final release and the Pantheon supernova compilation in a model-independent fashion using Gaussian process regression. We also test their joint consistency with the ΛCDM model in a model-independent fashion. We also use Gaussian process regression to reconstruct the expansion history that is preferred by these two data sets. While this methodology finds no significant preference for model flexibility beyond ΛCDM, we are able to generate a number of reconstructed expansion histories that fit the data better than the best-fit ΛCDM model. These example expansion histories may point the way toward modifications to ΛCDM. We also constrain the parameters Ω{sub k} and H {sub 0} r {sub d} both with ΛCDM and with Gaussian process regression. We find that H {sub 0} r {sub d} = 10,030 ± 130 km s{sup −1} and Ω{sub k} = 0.05 ± 0.10 for ΛCDM and that H {sub 0} r {sub d} = 10,040 ± 140 km s{sup −1} and Ω{sub k} = 0.02 ± 0.20 for the Gaussian process case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Macro-level mechanical interlocking: A rapid joining approach for additively manufactured compression molded composite panels

Composite joining typically involves multiple steps, such as drilling and surface treatment, as part of the manufacturing process, which leads to low throughput and long cycle times. In the present study, we demonstrated a macro-level mechanical interlocking (MI) based, rapid joining technique to assemble additively manufactured compression molded (AMCM) panels, enabling the production of parts larger than the mold dimensions. Composite panels made of 20 wt% short carbon fiber reinforced acrylonitrile butadiene styrene (CF/ABS) were joined using MI features of various geometries, namely tree (TR), dovetail (Dov), rectangle 2 (Rect2), and rectangle 1 (Rect1), and their in-plane strength was evaluated. The resultant strength of the tested MI joints reached up to 74 % of the baseline tensile strength (i.e., the ‘no joint’ case). Observations from optical and scanning electron microscopy revealed inadequate polymer diffusion between the adherends, indicating that the joint strength was primarily derived from mechanical interlocking. Additionally, the fracture surfaces exhibited stress-whitening marks, which were characterized using differential scanning calorimetry (DSC). The increase in melting enthalpy suggested local stretching of polymer chains due to MI. Finite element analysis (FEA) indicated that the Rect1 MI feature, which generated the lowest stress concentration, outperformed the others in terms of joint strength, achieving 42 MPa. As a demonstration of the MI joining method, a battery box tray measuring 108 cm × 34 cm using a mold with an effective dimension of 36 cm × 34 cm successfully manufactured, resulting in a part with an area three times larger than the mold. In conclusion, this study presents a promising approach to improving composite joining techniques while minimizing production complexities.

In-plane joining↗

Polyhalohydrins: Investigating Vicinal Functionalities by Ring-Opening of Epoxides on Polyolefins

Halohydrins are functional groups that are underexplored in polymer science. This study synthesized and examined structure–property relationships of halohydrin-functionalized polymers derived from polycyclooctene (PCOE), which was obtained via ring-opening metathesis polymerization (ROMP). The polyhalohydrins, including polychlorohydrin, polybromohydrin, and polyiodohydrin, were produced through a two-step process involving epoxidation of PCOE followed by epoxide ring-opening using hydrochloric, hydrobromic, or hydroiodic acid. These stereoirregular and regioirregular polymers are amorphous as measured by differential scanning calorimetry and X-ray scattering. Lap joint shear testing revealed an enhanced adhesive performance in polychlorohydrin and polybromohydrin, with the former demonstrating nearly three times the ultimate shear stress compared to a model polyethylene, hydrogenated PCOE. Additionally, contact angle measurements and surface free energy analysis showed an increase in hydrophilicity and polarity from iodine- to bromine- to chlorine-functionalized polyhalohydrins, aligning with trends in adhesion strength. Furthermore, these results underscore the potential of halohydrin functionalization as a versatile approach for tuning surface properties, offering new opportunities for polymer-to-polymer transformations.

Functional groups↗

Signatures of Light Massive Relics on non-linear structure formation

ABSTRACT Cosmologies with Light Massive Relics (LiMRs) as a subdominant component of the dark sector are well-motivated from a particle physics perspective, and can also have implications for the σ8 tension between early and late time probes of clustering. The effects of LiMRs on the cosmic microwave background (CMB) and structure formation on large (linear) scales have been investigated extensively. In this paper, we initiate a systematic study of the effects of LiMRs on smaller, non-linear scales using cosmological N-body simulations; focusing on quantities relevant for photometric galaxy surveys. For most of our study, we use a particular model of non-thermal LiMRs but the methods developed generalizing to a large class of LiMR models – we explicitly demonstrate this by considering the Dodelson–Widrow velocity distribution. We find that, in general, the effects of LiMR on small scales are distinct from those of a ΛCDM universe, even when the value of σ8 is matched between the models. We show that weak lensing measurements around massive clusters, between ∼0.1 h−1Mpc and ∼10 h−1Mpc, should have sufficient signal-to-noise in future surveys to distinguish between ΛCDM and LiMR models that are tuned to fit both CMB data and linear scale clustering data at late times. Furthermore, we find that different LiMR cosmologies indistinguishable by conventional linear probes can be distinguished by non-linear probes if their velocity distributions are sufficiently different. LiMR models can, therefore, be best tested by jointly analyzing the CMB and late-time structure formation on both large and small scales.

79 ASTRONOMY AND ASTROPHYSICS↗

A Short-Term Solar Forecasting Platform Using a Physics-Based Smart Persistence Model and Data Imputation Method

Electrical energy plays vital role in our socio-economic activity and therefore ensuring the reliability of the electric grid, from the generation, transmission and distribution level is critical. In order to maintain the power system parameter viz., frequency, voltage, etc., optimally, balancing of generation and consumption is very much essential. However, solar energy is infirm power by nature this is due to cloud cover / other local phenomena. Hence, Photovoltaic (PV) power generation brings a significant challenge to the grid operator due to the variability of the solar energy. The complexity of this challenge in terms of planning and dispatch ability of PV resources, aggravates with the high penetration of solar energy into the electric grid. In this setting, reliable solar radiation forecasting models based on accurate and quality input data become essential. In order to develop a suitable model for predicting solar radiation, quality historical / real time measurement is also needed. Under this study NIWE and NREL jointly developed / tested short-term solar forecasting frameworks using a smart persistence and physics-based smart persistence models for intra-hour forecasting of solar radiation (PSPI) and benchmarked 9 different data imputation techniques in 15 Solar Radiation Resource Assessment (SRRA) stations, located at different parts of India. During any measurement campaign, due to various technical reasons, we may miss few observations. However, the missing observation often reduce the performance of any forecasting model. Therefore, suitable data imputation method would assist us to obtain continuous observation of solar radiation. A station-by-station and method-by-method analysis was carried out to understand the performance of each model. Based on our analysis, among all the data imputation methods, the Kalman data imputation method is better for Indian Weather condition. In addition, Kalman StructTS, Linear, Stine and Arima methods yield slightly inferior accuracy compared to Kalman, but outperform the other methods. The extended solar radiation data are used by solar forecasting models to provide the prediction of solar radiation at 15 SRRA stations. As far as short term forecasting model is concerned, the PSPI model outperforms the Smart Persistence model. However, the forecast error is increases with the forecasting horizon.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Space flight operations for world development.

Mission objectives, hardware development efforts, and aspects of international cooperation are covered in an outline of space flight programs planned by the United States for the forthcoming decade. Scientific experiments envisioned for the Apollo 17 mission and for the Skylab program are discussed along with the current status of the joint Apollo/Soyuz test project specified by the U.S.-USSR space agreement of May 1972. The Space Shuttle, Space Tug, and Sortie Laboratory projects are outlined with emphasis on the use of experience and hardware gained in earlier phases of this space program.

Myers, D. D.↗

High pressure space suit glove

The High Pressure Space Suit Glove Program yielded one prototype glove assembly with an operating pressure of 8.0 psi. The following developments are reported: (1) A new layup technique for incorporation of the mini-convolute systems; (2) modification in the mini-convolute construction to assure cycle life at 8.0 psi in excess of 100,000 cycles; (3) the development of a unique non-orthogonal low torque wrist joint; (4) the development of a low torque single axis joint for use in the thumb and finger first metacarpal joints; and (5) a number of approaches to 1st metacarpal joints were fabricated and tested to establish the joint technqiues.

Elkins, W.↗

Preliminary results of fisheries investigation associated with Skylab-3

The purpose of the 15-month investigation now in the analysis phase is to establish the feasibility of utilizing remotely sensed data acquired from aircraft and satellite platforms to provide information concerning the distribution and abundance of oceanic gamefish. Data from the test area, jointly acquired by private and professional fishermen and NASA and NOAA/NMFS elements, in the northeastern Gulf of Mexico has made possible the identification of significant environmental parameters for white marlin. Predictive models based on catch data and surface truth information have been developed and have demonstrated potential for reducing search significantly by identifying areas which have a high probability of being productive. Three of the parameters utilized by the model, chlorophyll-a, sea surface temperature and turbidity have been inferred from aircraft sensor data.

Savastano, K.↗

Safely splicing glass optical fibers

Field-repair technique fuses glass fibers in flammable environment. Apparatus consists of v-groove vacuum chucks on manipulators, high-voltage dc power supply and tungsten electrodes, microscope to observe joint alignment and fusion, means of test transmission through joint. Apparatus is enclosed in gas tight bos filled with inert gas during fusion. About 2 feet of fiber end are necessary for splicing.

Korbelak, K.↗