Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Uniform high irradiance source

New 50 Kw xenon short arc lamp mounted within elliptical collector provides irradiance levels up to 4.4 x 10 to the 7th power watts/sq m with non-uniformity ratio of 3.30. Energy mixer or light pipe between lamp source and target improves non-uniformity to required ratio.

Lunde, A. R.↗

Optical bias assembly

Assembly, used to achieve linear response in optical detection system, consists of tungsten lamp source, optical filters, fiber optics bundle, aperture mask, relay lens, and folding mirror. Tungsten lamp source provides sufficient background illumination to make input optical flux small compared to background.

Weagant, R.↗

High energy solar beam testing in the JPL 25-ft space simulator

Modifications to the individual components in the solar simulation system to improve performance and reduce costs are described. The improvements include: an increase in lamp power from 20 KW to 30 KW; a family of solar beams from 8 to 18.5 feet in diameter at intensities related to beam size with a maximum intensity of 12 solar constants over a 9 ft. diameter; and up to 1.1 megawatts of simulated solar energy in the lamp array.

Harrell, J. W.↗

On disequilibrated rotational distributions of CN/X/ produced in the photolysis of ClCN

The rotational-vibrational product state distributions of the CN(X 2Sigma (+)) radicals which are produced in photolysis at a wavelength of about 160 nm were monitored by laser-induced fluorescence detection. A nitrogen laser pumped dye laser was used to excite the violet band fluorescence of CN. The number of collisions the radicals undergo between formation and detection was controlled by the total pressure and the time delay between the flash lamp pulse and the laser pulse. An argon flash lamp with a Suprasil transmission window was used to dissociate the ClCN. Disequilibrated rotational distributions of CN(X) are displayed, the spectrum showing that the nu = 0 and 1 levels are rotationally hot. The rotational distributions of CN(X 2 Sigma (+), nu = 0) are shown as a function of collision number. At a pressure of 0.070 torr and a delay of 2.0 microsecs, the distribution shows clearly that the excited rotational levels peak near N equals 66-70.

Sabety-Dzvonik, M.↗

Advanced combined iodine dispenser and detector

A total weight of 1.23 kg (2.7 lb), a total volume of 1213 cu m (74 cu in), and an average power consumption of 5.5W was achieved in the advanced combined iodine dispenser/detector by integrating the detector with the iodine source, arranging all iodinator components within a compact package and lowering the parasitic power to the detector and electronics circuits. These achievements surpassed the design goals of 1.36 kg (3.0 lb), 1671 cu m (102 cu in) and 8W. The reliability and maintainability were improved by reducing the detector lamp power, using an interchangeable lamp concept, making the electronic circuit boards easily accessible, providing redundant water seals and improving the accessibility to the iodine accumulator for refilling. The system was designed to iodinate (to 5 ppm iodine) the fuel cell water generated during 27 seven-day orbiter missions (equivalent to 18,500 kg (40,700 lb) of water) before the unit must be recharged with iodine crystals.

Lantz, J. B.↗

Middle atmosphere ion measurements during January, 1976

Parachute-borne measurements of electrical parameters in the stratosphere and mesosphere are discussed which were made in January 1976 as part of a 'coordinated winter-anomaly program' conducted at Wallops Flight Center, Va. The instruments used included Gerdien condensers, a blunt conductivity probe, and UV lamps for obtaining a measure of atmospheric NO. Measurements of the positive component of electrical conductivity on two 'anomalous' and two 'normal' days are compared, wave-interaction electron densities over the height range from 50 to 90 km are determined for the four days, and the effects of the UV lamps on one 'normal' and one 'anomalous' day are described. The results are shown to support the hypothesis that the enhancements in positive ion conductivity observed on 'anomalous' days are caused by a reduction of the aerosol population that is a 'normal' feature of the stratosphere and mesosphere. A possible scenario for this reduction is considered which involves electric-field transport of aerosol particles out of the upper stratosphere and mesosphere.

Hale, L. C.↗

Laser induced photoluminiscence studies of primary photochemical production processes of cometary radicals

A tunable vacuum ultraviolet flash lamp was constructed. This unique flash lamp was coupled with a tunable dye laser detector and permits the experimenter to measure the production rates of ground state radicals as a function of wavelength. A new technique for producing fluorescent radicals was discovered. This technique called multiphoton ultraviolet photodissociation is currently being applied to several problems of both cometary and stratospheric interest. It was demonstrated that NO2 will dissociate to produce an excited fragment and the radiation can possibly be used for remote detection of this species.

Jackson, W. M.↗

Development of a drift-correction procedure for a photoelectric spectrometer

A technique has been developed to automatically correct for drifts in the radiometric sensitivity of the detector channels in a direct-reading emission spectrometer. The method utilizes a 1000 W tungsten-halogen reference lamp to illuminate the detectors through the same optical path as that traversed during the analysis of the sample. Detector channel responses to the light are compared to those for the same light intensity at the time of analytical calibration. This corrects for the drift. It is noted that with the exception of positioning the lamp, the procedure is fully automatic.

Chapman, G. B., II↗

Determination of total surface reflectivity

Method of measuring total reflectance employs relatively inexpensive reflectometer with gold-coated hemispherical reflector. Light sources may be tungsten lamp for visable region, or Globar lamp for infrared.

Desmet, D. J.↗

Continuous discharge Penning source with emission lines between 50 A and 300 A

The present paper deals with a modified Penning discharge lamp developed specially to cover the soft X-ray and extreme UV spectral regions. The source produces a total of nearly 40 intense lines in the 50 to 300 A range. The lamp is quiet, continuous, and stable over most of the cathode lifetime (which is sufficient for long calibration runs). When the cathodes become exhausted, the refurbishment procedure is so simple that the source can be back on line in an hour or less

Finley, D. S.↗

Qualitative and quantitative flow visualization technique using ozone

The paper describes a new flow-visualization technique based on the absorption of ultraviolet light by ozone. Ozone is an excellent tracer, because as a gas it has the same effective physical properties as air. Ozone strongly absorbs the principal line (253.7 nm) of a mercury lamp, so that when an ozone-traced flow passes between a mercury lamp and a fluorescent screen, a sharp, shadow-like image of the ozone tracer is cast on the screen. Quantitative photometry can be carried out by replacing the screen with ultraviolet detectors that yield the path-integrated column density of ozone in the flow. High-speed quantitative point monitoring (10 Hz at 10 ppb O3) is possible with capillary probes and chemiluminescent analysis.

Dickerson, R. R.↗

An analytical tool for simulating Large AMplitude Propellant Slosh

The development of a multiple-mass, nonlinear, finite-element analytical model - the Large AMplitude Propellant Slosh model (LAMPS) in two- and three-dimensional versions, is described. The model is used in predicting the forces on the Space Shuttle external tank caused by large amplitude motion of propellant fluid. Comparisons between measured propellant reorientation forces and those predicted by the LAMPS models are presented, and it is concluded that the model provides a cost effective, experimentally verified approach to a complicated nonlinear problem.

Berry, R. L.↗

Assembly of Photovoltaic Arrays

Vacuum holddown fixtures hold photovoltaic solar cells during assembly into array. Tab attachment fixture holds single cell and interconnecting tabs during heat-lamp soldering. Array-layout fixture has computer-scribed layout template and holds cells (with attached tabs) while being placed in position and transferred to array-interconnection fixture, which holds cells during final soldering step. Group of heat lamps on trolley passes slowly over interconnection fixture to heat cells to soldering temperature.

Coyle, P. J.↗

Spacecraft thermal balance testing using infrared sources

A thermal balance test (controlled flux intensity) on a simple black dummy spacecraft using IR lamps was performed and evaluated, the latter being aimed specifically at thermal mathematical model (TMM) verification. For reference purposes the model was also subjected to a solar simulation test (SST). The results show that the temperature distributions measured during IR testing for two different model attitudes under steady state conditions are reproducible with a TMM. The TMM test data correlation is not as accurate for IRT as for SST. Using the standard deviation of the temperature difference distribution (analysis minus test) the SST data correlation is better by a factor of 1.8 to 2.5. The lower figure applies to the measured and the higher to the computer-generated IR flux intensity distribution. Techniques of lamp power control are presented. A continuing work program is described which is aimed at quantifying the differences between solar simulation and infrared techniques for a model representing the thermal radiating surfaces of a large communications spacecraft.

Tan, G. B. T.↗

Arc discharge convection studies: A Space Shuttle experiment

Three mercury vapor arc lamps were tested in the microgravity environment of one of NASA's small, self-contained payloads during STS-41B. A description of the payload structural design, photographic and optical systems, and electrical system is provided. Thermal control within the payload is discussed. Examination of digital film data indicates that the 175 watt arc lamp has a significant increase in light output when convection is removed in the gravity-free environment of space.

Bellows, A. H.↗

A comparison of observed and numerically predicted eddy kinetic energy budgets for a developing extratropical cyclone

The eddy kinetic energy budget is calculated for a 48-hour forecast of an intense occluding winter cyclone associated with a strong well-developed jet stream. The model output consists of the initialized (1200 GMT January 9, 1975) and the 12, 24, 36, and 48 hour forecast fields from the Drexel/NCAR Limited Area Mesoscale Prediction System (LAMPS) model. The LAMPS forecast compares well with observations for the first 24 hours, but then overdevelops the low-level cyclone while inadequately developing the upper-air wave and jet. Eddy kinetic energy was found to be concentrated in the upper-troposphere with maxima flanking the primary trough. The increases in kinetic energy were found to be due to an excess of the primary source term of kinetic energy content, which is the horizontal flux of eddy kinetic energy over the primary sinks, and the generation and dissipation of eddy kinetic energy.

Dare, P. M.↗