Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Stationary and drone-assisted methane plume localization with dispersion spectroscopy

This work presents stationary and mobile retroreflector-based remote sensing techniques for methane leak localization and quantification using chirped laser dispersion spectroscopy equipped with a custom laser transceiver capable of continuous tracking of a flying drone and coupled with inverse atmospheric gas dispersion modeling. The techniques demonstrate the ability to localize leaks as low as 0.13 g CH 4 ·s -1 , which are up to 25 times smaller than those typically observed at natural gas facilities, as well as actively track a moving retroreflector mounted on a lightweight (~250 g) drone to enable spatial plume reconstruction. This system exhibited a 2.3 ppm-m sensitivity over pathlengths of 40–150 m. Source localization to within ±7 m is demonstrated using a modified horizontal radial plume mapping technique with a stationary retroreflector grid. Meanwhile, the mobile system utilizing a drone-mounted retroreflector is able to localize a controlled release within ±1 m of its source location and estimate leak rates using inversion techniques assuming type B Gaussian plume stability class within ±30% error with respect to the actual low flow rate releases.

47 OTHER INSTRUMENTATION↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Photodissociation and Infrared Spectroscopy of Uranium–Nitrogen Cation Complexes

Laser vaporization of uranium in a pulsed supersonic expansion of nitrogen is used to produce complexes of the form U + (N 2 ) n (n = 1–8). These ions are mass selected in a reflectron time-of-flight spectrometer and studied with visible and UV laser fixed-frequency photodissociation and with tunable infrared laser photodissociation spectroscopy. The dissociation patterns and spectroscopy of U + (N 2 ) n indicate that N 2 ligands are intact molecules and that there is no insertion chemistry resulting in UN + or NUN + . Fixed frequency photodissociation at 532 and 355 nm indicate that the U + –N 2 bond dissociation energy varies little with changing coordination. The photon energy and the number of ligands eliminated allow an estimate of the average U + –N 2 dissociation energy of 12 kcal/mol. Infrared bands are observed for these complexes near the N–N stretch vibration via elimination of N 2 molecules. These resonances are observed to be shifted about 130 cm–1 to the red from the free-N 2 frequency for complexes with n = 3–8. Density functional theory indicates that U + is most stable in the sextet state in these complexes and that N 2 molecules bind in end-on configurations. Furthermore, the fully coordinated complex is predicted to be U + (N 2 ) 8 , which has a cubic structure. The vibrational frequencies predicted by theory are consistently lower than those in the experiment, independent of the isomeric structure or spin state of the complexes. Despite its failure to reproduce the infrared spectra, theory provides an average U + –N 2 dissociation energy of 11.8 ± 0.5 kcal/mol, in good agreement with the value from the experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗

Measurements of atoms and metastable species in N 2 and H 2 –N 2 nanosecond pulse plasmas

We report time-resolved, absolute number densities of metastable N 2 (A 3 Σ u + , v = 0, 1) molecules, ground state N 2 and H atoms, and rotational–translational temperature have been measured by tunable diode laser absorption spectroscopy and two-photon absorption laser-induced fluorescence in diffuse N 2 and N 2 –H 2 plasmas during and after a nanosecond pulse discharge burst. Comparison of the measurement results with the kinetic modeling predictions, specifically the significant reduction of the N 2 (A 3 Σ u + ) populations and the rate of N atom generation during the burst, suggests that these two trends are related. The slow N atom decay in the afterglow, on a time scale longer than the discharge burst, demonstrates that the latter trend is not affected by N atom recombination, diffusion to the walls, or convection with the flow. This leads to the conclusion that the energy pooling in collisions of N 2 (A 3 Σ u + ) molecules is a major channel of N 2 dissociation in electric discharges where a significant fraction of the input energy goes to electronic excitation of N 2 . Additional measurements in a 1% H 2 –N 2 mixture demonstrate a further significant reduction of N 2 (A 3 Σ u + , v = 0, 1) populations, due to the rapid quenching by H atoms accumulating in the plasma. Comparison with the modeling predictions suggests that the N 2 (A 3 Σ u + ) molecules may be initially formed in the highly vibrationally excited states. The reduction of the N 2 (A 3 Σ u + ) number density also diminishes the contribution of the energy pooling process into N2 dissociation, thus reducing the N atom number density. The rate of N atom generation during the burst also decreases, due to its strong coupling to N 2 (A 3 Σ u + , v) populations. On the other hand, the rate of H atom generation, produced predominantly by the dissociative quenching of the excited electronic states of N 2 by H 2 , remains about the same during the burst, resulting in a nearly linear rise in the H atom number density. Comparison of the kinetic model predictions with the experimental results suggests that the yield of H atoms during the quenching of the excited electronic state of N 2 by molecular H 2 is significantly less than 100%. The present results quantify the yield of N and H atoms in high-pressure H 2 –N 2 plasmas, which have significant potential for ammonia generation using plasma-assisted catalysis

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-based conversion electron Mössbauer spectroscopy of 229 ThO 2

The exceptionally low-energy 229 Th nuclear isomeric state is expected to provide several new and powerful applications, including the construction of a robust and portable solid-state nuclear clock, perhaps contributing to a redefinition of the second, exploration of nuclear superradiance and tests of fundamental physics. Further, analogous to the capabilities of traditional Mössbauer spectroscopy, the sensitivity of the nucleus to its environment can be used to realize laser Mössbauer spectroscopy and, with it, new types of strain and temperature sensors and a new probe of the solid-state environment, all with excellent sensitivity. However, current models for examining the nuclear transition in a solid require the use of a high-bandgap, vacuum ultraviolet (VUV) transmissive host, severely limiting the applicability of these techniques. Here we report the first, to the authors’ knowledge, demonstration of laser-induced conversion electron Mössbauer spectroscopy (CEMS) of the 229 Th isomer in a thin ThO 2 sample whose bandgap (approximately 6 eV) is considerably smaller than the nuclear isomeric state energy (8.4 eV). Unlike fluorescence spectroscopy of the 229 Th isomeric transition, this technique is compatible with materials whose bandgap is less than the nuclear transition energy, opening a wider class of systems to study and the potential of a conversion-electron-based nuclear clock.

36 MATERIALS SCIENCE↗

Sodium tracer measurements of an expanded dense aluminum plasma from e-beam isochoric heating

Spatially and temporally resolved visible absorption spectroscopy is performed on sodium D-lines present as surface contaminants on an expanded dense aluminum plasma plume. An 80-ns FWHM, intense, relativistic electron beam deposits 5.4 J into a 100- μ m-thick Al foil, which isochorically heats and subsequently hydrodynamically expands the material through the warm dense matter state and into a classical-like plasma state, with a coupling parameter of approximately 0.2 and a degeneracy parameter of approximately 270. The Na contamination, carried along with the expanding plume, shows saturated absorption features in the dense Al continuum for λ > 450 nm. X-ray photoelectron spectroscopy and laser-induced breakdown spectroscopy confirm Na is a surface contaminant with an atomic concentration of ~ 0.1 % when interrogating identical foil samples. Additioanlly, a spectroscopic-quality radiation transport model is used to post-process 2D hydrodynamic simulations to interpret the plasma conditions based on the measured Na 3p-3s doublet line profiles. A sodium number density of 3 × 10 15 cm -3 best matches the experimental spectra, which originate from a dense surface plasma with n e = 3.0 ± 0.8 × 10 18 cm -3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent electronic-vibrational dynamics in deuterium bromide probed via attosecond transient-absorption spectroscopy

Ultrafast laser excitation can trigger multiplex coherent dynamics in molecules. Here, we report attosecond transient-absorption experiments addressing simultaneous probing of electronic and vibrational dynamics in a prototype molecule, deuterium bromide (DBr), following its strong-field ionization. Electronic and vibrational coherences in the ionic X$^2\Pi_{3/2}$ and X$^2\Pi_{1/2}$ states are characterized in the Br-$3d$ core-level absorption spectra via quantum beats with 12.6-fs and 19.9-fs periodicities, respectively. Polarization scans reveal that the phase of the electronic quantum beats depends on the probe direction, experimentally showing that the coherent electronic motion corresponds to the oscillation of the hole density along the ionization-field direction. The vibrational quantum beats are found to maintain a relatively constant amplitude, whereas the electronic quantum beats exhibit a partial decrease in time. Quantum wave-packet simulations show that the decoherence effect from the vibrational motion is insignificant because of the parallel relation between the X$^2\Pi_{3/2}$ and X$^2\Pi_{1/2}$ potentials. Finally, a comparison between the DBr and HBr results suggests that rotation motion is responsible for the decoherence since it leads to initial alignment prepared by the strong-field ionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Time-domain self-broadened and air-broadened nitrogen S-branch Raman linewidths at 80–200 K recorded in an underexpanded jet

We report pure-rotational N 2 –N 2 , N 2 –air, and O 2 –air S-branch linewidths for temperatures of 80–200 K by measuring the time-dependent decay of rotational Raman coherences in an isentropic free-jet expansion from a sonic nozzle. We recorded pure-rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) spectra along the axial centerline of the underexpanded jet, within the barrel shock region upstream of the Mach disk. The dephasing of the pure-rotational Raman coherence was monitored using probe-time-delay scans at different axial positions in the jet, corresponding to varying local temperatures and pressures. The local temperature was obtained by fitting CARS spectra acquired at zero probe time delay, where the impact of collisions was minimal. The measured decay of each available Raman transition was fit to a dephasing constant and corrected for the local pressure, which was obtained from the CARS-measured static temperature and thermodynamic relationships for isentropic expansion from the known stagnation state. Nitrogen self-broadened transitions decayed more rapidly than those broadened in air for all temperatures, corresponding to higher Raman linewidths. In general, the measured S-branch linewidths deviated significantly in absolute and relative magnitudes from those predicted by extrapolating the modified exponential gap model to low temperatures. The temperature dependence of the Raman linewidth for each measured rotational state of nitrogen (J ≤ 10) and oxygen (N ≤ 11) was fit to a temperature-dependent power law over the measurable temperature domain (80–200 K) and extrapolated to both higher rotational states and room temperature. Furthermore, the measured and modeled low-temperature linewidth data provided here will aid low temperature gas-phase pressure measurements with fs/ps CARS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum beats in two-color photoionization to the spin-orbit split continuum of Ar

We report a study of the quantum beats in two-color photoionization of argon. An attosecond extreme ultraviolet pulse train prepares an electronic wave packet of definite odd parity, with total angular momentum J = 1, targeting the states between 14.0 and 14.5 eV from the ground state. Two-photon ionization of this wave packet with a tunable infrared probe pulse makes the constituent states interfere in both continuum channels, corresponding to the core angular momenta j c = 1/2 and 3/2, respectively. We analyze photoelectron spectrograms as a function of the time delay of the probe pulse and identify oscillations due to several pairs of states through Fourier decomposition. We observe phase differences between the corresponding beat signals in the two spin-orbit split continua. Comparison of theoretical simulations with the experimental measurements allows us to interpret the amplitudes and phases of ionization signals. Furthermore, we express the observed phase differences in terms of the off-diagonal elements of the short-range scattering matrix and the dipole matrix elements to the continuum eigenchannels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Element-specific investigations of ultrafast dynamics in photoexcited Cu2ZnSnS4 nanoparticles in solution

Ultrafast, light-induced dynamics in copper–zinc–tin–sulfide (CZTS) photovoltaic nanoparticles are investigated through a combination of optical and x-ray transient absorption spectroscopy. Laser-pump, x-ray-probe spectroscopy on a colloidal CZTS nanoparticle ink yields element-specificity, which reveals a rapid photo-induced shift of electron density away from Cu-sites, affecting the molecular orbital occupation and structure of CZTS. We observe the formation of a stable charge-separated and thermally excited structure, which persists for nanoseconds and involves an increased charge density at the Zn sites. Combined with density functional theory calculations, the results provide new insight into the structural and electronic dynamics of CZTS absorbers for solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure-Induced Dimerization of C 60 at Room Temperature as Revealed by an In Situ Spectroscopy Study Using an Infrared Laser

Using in situ high-pressure Raman spectroscopy and X-ray diffraction, the polymerization and structure evaluation of C 60 were studied up to 16 GPa at room temperature. The use of an 830 nm laser successfully eliminated the photo-polymerization of C 60 , which has interfered with the pressure effect in previous studies when a laser with a shorter wavelength was used as excitation. It was found that face-centered cubic (fcc) structured C 60 transformed into simple cubic (sc) C 60 due to the hint of free rotation for the C 60 at 0.3 GPa. The pressure-induced dimerization of C 60 was found to occur at about 3.2 GPa at room temperature. Our results suggest the benefit and importance of the choice of the infrared laser as the excitation laser.

36 MATERIALS SCIENCE↗

Double-walled containment cell

Double-walled containment cells are described as may be used for storage, transport, and examination of a sample held within the cell by use of optical analysis techniques. A double-walled containment cell can include multiple types of windows that can be located as desired on the containment cells and thereby provide for optical access to a sample for multiple optical analysis techniques. Disclosed containment cells can be sized and designed for use with existing optical analysis systems, e.g., laser ablation, X-ray diffraction, spectral analysis (e.g., Raman spectroscopy, infrared spectroscopy, laser-induced breakdown spectroscopy, etc.), imaging analysis, etc.

Villa-Aleman, Eliel↗

Application of emerging monitoring techniques at the Illinois Basin – Decatur Project

The Illinois Basin – Decatur Project is a large-scale carbon capture and storage demonstration project located in Decatur, Illinois, USA. In this project, one million metric tons of carbon dioxide (CO 2 ) was captured from an ethanol production facility and successfully injected into a deep saline reservoir over a period of three years. The scale of this project presented an opportunity to explore emerging technologies for effective long-term monitoring of the carbon capture and storage site. This research documents the application of three emerging monitoring techniques: (1) a prototype “open-path” sensor, a method of continuously monitoring atmospheric CO 2 by applying tunable diode laser absorption spectroscopy to provide a warning system for personnel safety along pipelines and at wellheads; (2) the Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE), an automated system for measuring two-dimensional spatial distribution of atmospheric CO 2 concentrations; and (3) periodic aerial imagery, a method of documenting surface-vegetation dynamics to detect vegetative responses to CO 2 leaks. The objective of this work was to assess the advantages and limitations of these monitoring techniques and quantify their reliability over an extended deployment at an active industrial site. These results will aid in determining viability of long-term monitoring on a commercial scale.

42 ENGINEERING↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Distinguishing the XUV-induced Coulomb explosion dynamics of iodobenzene using covariance analysis

The primary and secondary fragmentation dynamics of iodobenzene following its ionization at 120 eV were determined using three-dimensional velocity map imaging and covariance analysis. Site-selective iodine 4d ionization was used to populate a range of excited polycationic parent states, which primarily broke apart at the carbon-iodine bond to produce I+ with phenyl or phenyl-like cations (C n H x + or C n H, with n = 1 – 6 and x = 1 – 5). The molecular products were produced with varying degrees of internal excitation and dehydrogenation, leading to stable and unstable outcomes. This further allowed the secondary dynamics of C 6 H x 2+ intermediates to be distinguished using native-frame covariance analysis, which isolated these processes in their own centre-of-mass reference frames. Furthermore, the mass resolution of the imaging mass spectrometer used for these measurements enabled the primary and secondary reaction channels to be specified at the level of individual hydrogen atoms, demonstrating the ability of covariance analysis to comprehensively measure the competing fragmentation channels of aryl cations, including those involving intermediate steps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of atomic oxygen densities using TALIF on a dielectric barrier discharge: insights into the volume above a micro cavity plasma array

Dielectric barrier discharges, particularly micro cavity plasma arrays, offer significant potential for plasma-catalytic research due to their ability to ignite plasma in direct contact with a catalytic surface, enabling the observation of plasma-surface interactions. A key factor in their application is the generation of reactive species, such as atomic oxygen, within the cavities. These species can interact with both the surface (e.g. for activation or cleaning) and the gas being treated (e.g. for oxidation). Given the central role of oxygen atoms in plasma catalysis and their use as a model for more complex species, this work investigates the transport of these atoms out of the cavities. Two-photon absorption laser-induced fluorescence spectroscopy with picosecond laser excitation is performed in the volume above the cavities. The results are compared with a basic diffusion model. The reactor operates with a He/O 2 mixture at a flow rate of 1 slm and atmospheric pressure. Densities of up to 10 16 cm -3 are measured near the surface. Time-dependent measurements show that, at a distance of 350 µm from the surface, a density equilibrium is reached within less than 3 ms of reactor operation. Decay times due to ozone formation after the reactor is turned off are on a similar scale. Spatially resolved measurements show that the oxygen density decreases exponentially from the surface but remains detectable up to approximately 1 mm above the surface, indicating significant application potential. Variations in the O 2 admixture show a density maximum at 0.4%, confirming previous helium state enhanced actinometry measurements within the cavities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗