Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOAD CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Micromovements and discomfort associated with flight mission with helmet operation tasks with different levels of cognitive workload

When performing stationary tasks under elevated cognitive workload, individuals must perform continual muscle contractions to maintain stability of the body, resulting in fatigue of the postural muscles. When the muscles perform these contractions in a prolonged manner, the body potentially responds through small changes in body movements—micromovements that may lead to discomfort. The study purpose was to evaluate impact of cognitive load on micromovements. The micromovements were measured during three different cognitive workloads; low, medium, and high. The NASA-TLX score was used to evaluate the perceived mental workload and discomfort was assessed by visual analog scale. In total, 60 subjects (30 males and 30 females) were recruited and performed cognitive tasks that simulated flight operations such as changing the radio frequency based on air traffic control messages, balancing the fuel levels in simulated fuel tanks, and aiming a reticle in a designated moving target using the cyclic control. Cognitive load was defined by the frequency of events. Micromovements were defined by changes in the center of pressure (COP) of the seat pan and COP standard deviation. It was found that the high cognitive workloads had the highest NASA-TLX scores including mental demands, temporal demands, and effort. The neck area had the highest overall levels of discomfort followed by upper back. The highest standard deviation for COP shift and number of micromovements occurred for medium cognitive workloads. In conclusion, while there were some interesting trends, few trends reached a statistical significance due to high variability among subjects for the outcome variables.

60 APPLIED LIFE SCIENCES↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A semi-coupled aero-servo-hydro numerical model for floating vertical axis wind turbines operating on TLPs

Floating vertical axis wind turbines (VAWTs) have many advantages over floating horizontal axis wind turbines (HAWTs) at large scales in deep water; however, there are several key challenges to overcome as well. One of the challenges is accurate prediction of the dynamic motion and loads performance of a floating VAWT. Here, a new semi-coupled aero-servo-hydro method is developed to assess dynamic responses of a floating VAWT by modeling the system as a 7-degree-of-freedom (7-DOF) model: the supporting platform is considered as a 6-DOF rigid body; the rotation of the rotor is considered as the 7th DOF. Aerodynamic, hydrodynamic, and mooring loads and control of the rotor speed are fully considered. This model can predict performance of floating VAWTs with reasonable fidelity according to validation with OrcaFlex through static and dynamic responses of a floating VAWT with Darrieus rotor operating on a new tension-leg platform (TLP). Being a reduced complexity model, the 7-DOF model can be efficiently applied to assess performance of the newly designed floating VAWT. This model is used to examine the relative contributions of aerodynamic and wave loads imparted to the floating system and the benefits of a three-bladed VAWT over a two-bladed VAWT through dynamic and fatigue analysis.

17 WIND ENERGY↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. The deployment of wave energy converters (WECs) faces a design challenge with apparently contradictory goals. A WEC should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Adaptability to different sea states is, therefore, highly desirable. This work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. Therefore, the hinge experiences loads perpendicular to its axis as it maintains its position. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. Because opening the flaps lets the waves transmit through the paddle, it is hypothesized that opening the flaps should result in load shedding at the base of the support structure. The load shedding is achieved by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. The comparisons quantify the effects of letting the waves transmit through the VGOSWEC. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. It was observed that at the paddle's resonance frequency, the loads on the structure increased substantially. This increase in loads can be mitigated by a rotational power take-off damping about the hinge axis. Changing the rotational power take-off damping was identified as an additional design parameter that can be used to control the loads experienced by the WEC's support structure.

fixed and floating structures↗

Microstructural Evolution and ORR Activity of Nanocolumnar Platinum Thin Films with Different Mass Loadings Grown by High Pressure Sputtering

Nanocolumnar platinum thin films (Pt-TFs) with different Pt mass loadings were grown by high pressure sputtering (HIPS) and investigated as oxygen reduction reaction (ORR) electrocatalysts for polymer electrolyte membrane fuel cell applications. Mass loading was controlled by changing the sputter deposition time. A cauliflower-like columnar microstructure was achieved by depositing the Pt-TFs onto a microporous layer (MPL)-like surface composed of carbon particles in order to mimic catalyst-coated gas diffusion electrodes. Microstructural evolution of HIPS Pt-TFs and their ORR activity were investigated. Electrochemical characterization of the nanocolumnar Pt-TFs was performed by cyclic voltammetry and rotating disk electrode measurements on Pt-TF/MPL-like-layer/glassy-carbon samples in an aqueous perchloric acid electrolyte. The electrochemically active surface area increased from 18 to 39 m 2 g –1 as the Pt mass loading was decreased. Specific activity of the films was similar (~600 μA cm –2 ) for all Pt mass loadings, due to the similar nanoparticle sizes of ~5 nm as observed by transmission electron microscopy and X-ray diffraction. Furthermore, mass activity of the films increased from 0.11 to 0.26 A mg –1 as the Pt mass loading was decreased, which is an indication of the effective Pt utilization and better access through the catalyst layer at lower Pt mass loadings.

08 HYDROGEN↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. A wave energy converter (WEC) should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Furthermore, the WEC should be adaptable to different sea states. Herethis work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. It is hypothesized that opening the flaps should result in load shedding at the base of the support structure by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. Increased loads at the structure’s natural period can be mitigated by an axial power take-off damping acting as an additional design parameter to control the loads at the WEC’s support structure.

16 TIDAL AND WAVE POWER↗

Integrated ELM and divertor power flux control using RMPs with low input torque in EAST in support of the ITER research plan

Experiments have been carried out at the EAST tokamak to study ITER-relevant scenario integration issues, related to edge localized mode (ELM) control in H-mode plasmas by the application of three-dimensional (3D) resonant magnetic perturbations (RMPs), which have a large impact on the execution of the ITER research plan. The EAST experiments have successfully demonstrated ELM suppression at normalized torque inputs similar to ITER. The application of RMP fields with high toroidal mode number (n = 4) reduces the impact of ELM control on energy and particle confinement compared to those use lower n (n = 1, 2) RMPs. Injection of successive pellets is found to be effective in increasing the plasma density in ELM-suppressed H-modes and reducing the divertor power without triggering large ELMs at EAST. Access to high recycling and radiative divertor conditions while maintaining ELM suppression has been demonstrated in EAST by the use of gas fuelling and neon impurity seeding. Both approaches have been found to be effective in reducing power fluxes to the divertor strike points in near-separatrix lobes for both n = 2 and n = 4 RMPs. Furthermore, reduction of power fluxes in off-separatrix lobes is only effective for n = 4 RMP application, which is consistent with magnetic topology modelling (including plasma response) results showing a shallow penetration into the confined plasma region of field lines connected to these lobes compared to n = 2. The EAST results support the use of high n 3D fields for ELM suppression in ITER high Q DT scenarios since they provide optimum integration features regarding energy and particle confinement, pellet fuelling, radiative divertor operation while eliminating ELM transient power loads and being compatible with low torque input.

pellet fuelling↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of thermal treatment on structure and catalytic performance of ceria-zirconia supported copper oxide (CuO x /Ce y Zr 1-y O 2 ) catalysts for CO oxidation

Copper oxide (CuO x ) supported on ceria-zirconia (Ce y Zr 1-y O 2 , y = 1.0, 0.5, 0.0) catalysts were investigated to elucidate the effects of thermal treatment on their physicochemical properties and catalytic performance in carbon monoxide (CO) oxidation. Here, the catalysts were synthesized via a one-pot chemical vapor deposition (OP-CVD) method at 700˚C and 900˚C with controlled Cu loading. Characterization techniques, including synchrotron X-ray diffraction (S-XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), inductively coupled plasma spectroscopy (ICP), and N 2 adsorption-desorption, were implemented to probe the crystalline structure, molecular and electronic structure, oxygen vacancies, specific surface area (SSA) and metal loading. CO oxidation was chosen as a model reaction to explore the structure-catalytic performance relationship. A ∼100% CO conversion was achieved at < 150˚C, particularly with the CuO x /CeO 2 catalyst calcined at 700˚C. In contrast, calcination at 900˚C caused a ∼90% decrease in SSA and a ∼24% increase in T 50 . Activity tests revealed that increasing ZrO 2 content lowered CO oxidation activity despite generating more defect sites. In-situ measurement of the 700 °C calcined samples revealed the presence of stable and unstable defects in CuO x /Ce 0.5 Zr 0.5 O 2 and CeO 2 respectively, which play a key role in the activity of the catalysts. The results highlight that catalytic performance is closely related to the SSA. Furthermore, an optimum calcination temperature favor significant oxygen vacancy formation with required CuO x -support interactions, enhancing redox properties and catalytic performance.

36 MATERIALS SCIENCE↗

Real-time hybrid controls of energy storage and load shedding for integrated power and energy systems of ships

This paper presents an original energy management methodology to enhance the resilience of ship power systems. The integration of various energy storage systems (ESS), including battery energy storage systems (BESS) and super-capacitor energy storage systems (SCESS), in modern ship power systems poses challenges in designing an efficient energy management system (EMS). The EMS proposed in this paper aims to achieve multiple objectives. The primary objective is to minimize shed loads, while the secondary objective is to effectively manage different types of ESS. Considering the diverse ramp-rate characteristics of generators, SCESS, and BESS, the proposed EMS exploits these differences to determine an optimal long-term schedule for minimizing shed loads. Furthermore, the proposed EMS balances the state-of-charge (SoC) of ESS and prioritizes the SCESS’s SoC levels to ensure the efficient operation of BESS and SCESS. For better computational efficiency, we introduce the receding horizon optimization method, enabling real-time EMS implementation. Further, a comparison with the fixed horizon optimization (FHO) validates its effectiveness. Simulation studies and results demonstrate that the proposed EMS efficiently manages generators, BESS, and SCESS, ensuring system resilience under generation shortages. Additionally, the proposed methodology significantly reduces the computational burden compared to the FHO technique while maintaining acceptable resilience performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nanomolar Sensitivity Chirality Transfer from Designed Helical Repeat Proteins to Achiral CdS Nanorods

Bridging chirality across length scales with inorganic− organic hybrid materials is a rapidly expanding area of research. Here, we establish asymmetry at CdS nanorod (NR) interfaces using a designed helical repeat protein bearing four cysteine residues (DHR- 4Cys). Hydrophobic NRs are transferred into water with glycine, and then glycine is displaced by DHR-4Cys, leveraging the thiophilicity of cadmium. Circular dichroism (CD) in the visible, coincident with CdS electronic transitions, reveals a chiral DHR-4Cys:CdS interface. Here, the dissymmetry factor [g-factor = 4.5 × 10 −4 (short NRs) and 5.0 × 10 −4 (long NRs)] is weakly dependent on the NR length, and CD persists at nanomolar protein loadings. Additionally, control experiments demonstrate that DHR-4Cys:CdS NR chirality is dictated by the local coordination of Cys with no significant contribution from the chiral secondary structure of the protein (g-factors of short and long Cys:CdS NRs are 4.8 × 10 −4 and 4.0 × 10 −4 , respectively). Together with far-UV CD and transmission electron microscopy, which provide evidence of preserved protein structure, these results provide the first demonstration that a structurally defined protein can induce chirality in CdS nanocrystals while maintaining protein structure at biologically relevant concentrations.

Cadmium sulfide↗

Dimolybdenum Paddlewheel Complexes with Cation Binding Sites as Electrolyte Additives to Manipulate the Solid-Electrolyte Interphase at Lithium Metal Anodes

The use of electrolyte additives at millimolar loadings to control the surface chemistry of lithium metal anodes (LMAs) is a leading strategy to improve lithium metal batteries and promote electrosynthetic reactions. Whereas previous studies employed either inorganic or organic additives, in this study, we report the first organometallic additive, Mo 2 (mea) 4 [1, mea = 2-(2-methoxyethoxy)acetate], a dimolybdenum paddlewheel complex that is stable under Li plating conditions and features cation binding sites in the second coordination sphere that promote reversible Li + coordination. Binding of Li + ions to 1 induces immobilization of cationically charged aggregates (or products thereof) into the solid electrolyte interphase (SEI), imparting multiple beneficial functions. The modified SEI was found to protect the LMA against parasitic side reactions, produce modest but measurable improvements to Li plating properties (e.g., overpotential, surface structure, and Coulombic efficiency), and improve interfacial charge transport properties. Furthermore, the most notable benefit to battery cycling performance appears in calendar aging tests, which show that the presence of the additive protects the LMA from parasitic side reactions that would otherwise decrease overall cell cycling efficiency over time. Collectively, these data disclose a tactic for designing electrolyte additives using principles of organometallic synthesis.

Additives↗

Enhancing Low-Temperature Syngas Production via Surface Tailoring of Supported Intermetallic Nanocatalysts

An active and coke-resistant silica-encapsulated intermetallic Ni 3 Zn nanoparticle catalyst was developed for low-temperature (450 °C) dry reforming of methane (DRM). The catalyst exhibited a remarkable 4-fold increase in activity (4.5 s –1 ) with over 99% CO selectivity and 3 orders of magnitude less carbonaceous species and demonstrated remarkable stability (70 h) compared to that of a monometallic Ni catalyst. Here, the key is the combined effect of surface ensemble structure and electronic interaction modulation through the surface composition tailoring achieved by off-stoichiometric Ni and Zn loading in controlling surface chemistry for achieving different activities and H 2 /CO ratios. Characterized by ion spectroscopy, X-ray photoelectron spectroscopy, and the neutron pair distribution function, it was revealed that paired Ni δ – –Zn δ+ active sites are crucial for DRM. Transient infrared spectroscopy and isotopic analysis uncovered the synergistic effect of Ni δ – –Zn δ+ sites in activating C–H bonds and dissociating CO 2 to prevent coke formation under low-temperature conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Suppressing Excessive Light Rain on Aerosol Radiative Effects and Health Risks

Global climate models (GCMs) have been used widely to study radiative forcing and health risks of aerosols. A recent study using two GCMs found that light rain plays a dominant role in controlling aerosol loading. However, “too much light rain and too little heavy rain” is a longstanding bias in GCMs. It is unclear how much light rain affects aerosol-cloud-radiation interactions and health risks from air pollution. Here, in this work, we show that, with the correction of the rainfall intensity spectrum in the National Center for Atmospheric Research Community Atmosphere Model version 5.3 by introducing a stochastic deep convection scheme, the reduced frequency of light rain (1–20 mm d -1 ) results in changes of aerosol direct radiative effects (DRE) of up to -0.5 ± 0.03 W/m 2 and aerosol cloud radiative effects (CRE) of up to -0.9 ± 0.03 W/m 2 . The total (CRE + DRE) radiative effects of light rain-mediated aerosol changes exceed the present-day anthropogenic forcing of aerosols relative to preindustrial levels from the Coupled Model Intercomparison Project (CMIP5&6) models. However, the correction of the rainfall intensity spectrum has little effect on anthropogenic aerosol forcing (defined as the radiative perturbation due to changes in aerosol concentrations between the industrial era and preindustrial levels). Due to increased exposure to fine particulates (PM 2.5 ), the estimated global total premature mortality is much higher than previously estimated, by 300,000 ± 60,000 deaths per year, and is more severe in populous regions such as India and China. The findings in this study highlight the need to understand uncertainties in radiative effects and health risks of aerosols due to simulation biases of precipitation in GCMs.

54 ENVIRONMENTAL SCIENCES↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗