At least 253 records · Page 14

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-burnup Experiments in Reactivity Initiated Accidents (HERA)

HERA is a joint experimental program (JEEP) operating within the Nuclear Energy Agency’s (NEA’s) framework for irradiation experiments (FIDES). HERA is dedicated to the understanding of light water reactor (LWR) fuel performance at high burnup under reactivity-initiated accidents (RIA). During RIAs the fuel cladding can be breached by one of two mechanisms; pellet-cladding mechanical interaction or high temperature balloon and rupture. Pellet-cladding mechanical interaction (PCMI) failure occurs in the early phase of an RIA transient where the fuel pellet expands rapidly into the cladding prior to any meaningful heat transfer from the pellet to the cladding. This results in high stresses in the cladding resulting in crack propagation through the base Zircaloy metal and axially along the cladding tube. Failure by PCMI is a brittle failure mode and occurs at low cladding strains, approximately 2% hoop strain. If the cladding survives the PCMI phase of the transient, it may still fail due to ballooning and rupture induced by extended exposure to high temperature. Thermal transport from the fuel pin to the coolant is significantly reduced if a transition to film boiling on the cladding surface occurs. This result in both a rapid increase in fuel temperature, which drives fission gas release, and a spike in cladding temperature, which results in loss of mechanical strength. If the internal pressure of the fuel rod is greater than the system pressure the cladding can inelastically deform and eventually rupture. Failure by swelling and rupture occurs at larger strains, generally greater than 5% hoop strain. While PCMI failures are generally seen as more limiting, the dominance of one failure mode over the other can be affected by both the cladding material conditions, and the transient evolution.

(HERA)↗

High-burnup Experiments in Reactivity Initiated Accidents (HERA)

HERA is a joint experimental program (JEEP) operating within the Nuclear Energy Agency’s (NEA’s) framework for irradiation experiments (FIDES). HERA is dedicated to the understanding of light water reactor (LWR) fuel performance at high burnup under reactivity-initiated accidents (RIA). During RIAs the fuel cladding can be breached by one of two mechanisms; pellet-cladding mechanical interaction or high temperature balloon and rupture. Pellet-cladding mechanical interaction (PCMI) failure occurs in the early phase of an RIA transient where the fuel pellet expands rapidly into the cladding prior to any meaningful heat transfer from the pellet to the cladding. This results in high stresses in the cladding resulting in crack propagation through the base Zircaloy metal and axially along the cladding tube. Failure by PCMI is a brittle failure mode and occurs at low cladding strains, approximately 2% hoop strain. If the cladding survives the PCMI phase of the transient, it may still fail due to ballooning and rupture induced by extended exposure to high temperature. Thermal transport from the fuel pin to the coolant is significantly reduced if a transition to film boiling on the cladding surface occurs. This result in both a rapid increase in fuel temperature, which drives fission gas release, and a spike in cladding temperature, which results in loss of mechanical strength. If the internal pressure of the fuel rod is greater than the system pressure the cladding can inelastically deform and eventually rupture. Failure by swelling and rupture occurs at larger strains, generally greater than 5% hoop strain. While PCMI failures are generally seen as more limiting, the dominance of one failure mode over the other can be affected by both the cladding material conditions, and the transient evolution.

(HERA)↗

Initial development of a generic fluoride salt-cooled reactor model

Fluoride high-temperature reactors (FHRs) are high-temperature, low-pressure reactor concepts that use tri-structural isotropic (TRISO) fuel and molten fluoride salt coolant. These reactors have the potential to provide both electrical power and high-temperature process heat. We used generic FHR parameters for a pebble-bed FHR to develop an initial model with fresh fuel for a generic FHR (gFHR) in MELCOR and SCALE (NEWT and KENO). In this paper, we present the development of our gFHR models, which will serve as the baseline for a sensitivity and uncertainty analysis to quantify the range of possible source terms for FHRs in severe accidents. We present MELCOR results for fuel and coolant temperatures through the core, a nodalization study for the steady-state thermal hydraulic model, and development of reactor physics models in SCALE. As this work progresses, these models will be used to calculate source terms for a loss-of-forced-flow accident and to conduct a sensitivity study on this accident to establish a range of possible source terms. SCALE will provide reactor physics parameters like isotopic inventory, decay heat generation, and temperature coefficients of reactivity. Using the uncertainty quantification tools within SCALE, we will generate distributions for those parameters and will use the uncertainty quantification code RAVEN or DAKOTA to sample those distributions in MELCOR to quantify the impact of reactor physics and thermal hydraulic uncertainties on FHR source terms. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Physical and thermal property changes under uniform oxidation in nuclear graphite

Material property changes of fine- and medium-grain nuclear graphite grades were measured after subjection to uniform oxidation. The cores of high temperature reactors are composed of large nuclear graphite block components. Here, these large core components are designed to provide neutron moderation and reflection, create a large thermal sink to assist in operational control, and form the solid core structure containing the nuclear fuel, coolant channels, and the safety critical channels for control rod insertion. Oxidation is a principle degradation mechanism affecting all aspects of the nuclear graphite component functions. This study addresses the underlying physical property changes of nuclear-graphite components for oxidized mass loss ranges beyond the current recommended ASME code rule limits to ensure structural integrity within the graphite components (a maximum mass loss = 10%).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Design Alternatives of Actively Cooled RF Window for MPEX

The Materials Plasma Exposure eXperiment (MPEX) has been designed as a linear plasma divertor simulator in order to address plasma material interaction (PMI) science for next-generation fusion devices. It will have the capability to test neutron irradiated samples with plasma fluxes of greater than 10 24 m -2 s -1 . It is expected to operate steady state for up to 10 6 s to consider PMI affects through reactor end of life. The conceptual design of MPEX was completed in 2019, with preliminary design having begun in 2020. The plasma source for MPEX is a helicon antenna, where the energized helical antenna sits outside of the vacuum in order to minimize impurities in the plasma. It is expected to receive up to 200 kW of continuous power, and so the antenna and the window must be actively cooled. The water-cooled copper antenna has been operated at full power on the Proto-MPEX device (which is a test facility to demonstrate the plasma source and heating systems). The water-cooled window, however, is a novel component that must meet numerous competing requirements. It requires a low dielectric loss to allow the Radio Frequency (RF) power to create the plasma within the vacuum boundary. It must be structurally robust to handle the significant heat flux from the plasma and any heat from dielectric coupling. It must be compatible with the coolant (preferably water). It requires a vacuum seal that minimizes impurities into the plasma and does not compromise the structural integrity of the window. Two window designs have been tested. Results from these tests, where temperatures are measured and heat fluxes inferred from infrared camera data, have been correlated with thermal-structural simulations. When these simulations are extrapolated to the full power steady-state heat fluxes that are expected in MPEX, the designs do not appear to have the necessary structural robustness. This study explores design alternatives for the MPEX helicon antenna window, presents analysis results for several of the alternatives, and shows a viable solution that satisfies the requirements for MPEX operation.

Tipton Jr, Joseph↗

Rapid Cycling ReBCO Dipole Magnet Concept for Muon Acceleraion

We present a concept of the rapid-cycling 1.7 T ReBCO magnet for 1 to 10 kT/s ramping range as required for muon acceleration in a future muon collider presently under study. This approach is based on the 6 kA CORC-like cable constructed with 12 superconducting ReBCO tapes of 2 mm width. Based on theoretical prediction there is a linear scaling of the ReBCO cable hysteresis loss with the crossing magnetic field possibly generating power loss independent of the magnetic field ramping speed. This feature makes this ReBCO cable suitable for the construction of rapid-cycling magnets. In this work we outline the design of a dipole magnet for 1.7 T gap magnetic field and discuss the helium coolant parameters for the minimal electric power.

Piekarz, Henryk [Fermilab] (ORCID:0000000194225662↗

Rapid-cycling ReBCO dipole magnet concept for muon acceleration

We present a concept of the rapid-cycling 1.7 T ReBCO magnet for 1 to 10 kT/s ramping range as required for muon acceleration in a future muon collider presently under study. This approach is based on the 6 kA CORC-like cable constructed with 12 superconducting ReBCO tapes of 2 mm width. Based on theoretical prediction there is a linear scaling of the ReBCO cable hysteresis loss with the crossing magnetic field possibly generating power loss independent of the magnetic field ramping speed. This feature makes this ReBCO cable suitable for the construction of rapid-cycling magnets. In this work we outline the design of a dipole magnet for 1.7 T gap magnetic field and discuss the helium coolant parameters for the minimal electric power.

Piekarz, Henryk [Fermilab] (ORCID:0000000194225662↗

Estimation of the Thermal-Fluids and Thermal-Structural Performance of Helium-Cooled Modular Finger-Type Divertors

Over the past decade, our group has investigated the thermal-fluid performance of the helium-cooled modular divertor with multiple jets (HEMJ) and a simplified “flat” design of the HEMJ for long-pulse magnetic fusion energy (MFE) reactors. Experimental studies were performed in a helium (He) loop at the prototypical pressure of 10 MPa, nearly prototypical He temperatures and incident heat fluxes using test sections made from stainless steel and tungsten alloys. Correlations for average Nusselt numbers and pressure loss coefficients were developed from the data and are used to validate computational fluid dynamics (CFD) models. Here, this work presents updated thermal-fluids performance curves based on these correlations that estimate the maximum heat flux that can be accommodated by the plasma-facing surface and coolant pumping power requirements at prototypical operating conditions. Thermal-structural performance curves developed from ITER structural design criteria are introduced, which include protection against ductile and non-ductile failure, ratcheting fatigue, and creep fatigue. The performance design curves for these finger-type divertors demonstrate that the “flat” design, with a significantly less complicated geometry than the HEMJ, has thermal-fluid and thermal-structural performance comparable to the original HEMJ concept, and may be superior in terms of non-ductile failure criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Digital Twin Predictive Model for PWR Components: Updates on Multi Times Series Temperature Prediction Using Recurrent Neural Network, DMW Fatigue Tests, System Level Thermal-Mechanical-Stress Analysis

The long-term operation (LTO) of nuclear power plant (NPP) beyond their original design life of 40 years, can lead to more material damage associated with cyclic fatigue under thermal-mechanical loading cycles and associated long-term exposure of reactor material to the deleterious reactor-coolant environments. However, under this LTO condition the reactor components can still safely operate but may require more frequent Nondestructive Evaluation (NDE) of reactor components. Frequent NDE requirement may lead to frequent shutdown of the NPP. This in turn can lead to power outage and additional NDE-inspection-cost related economic loss. The economic loss can be minimized by reducing uncertainty in life estimation of safety-critical pressure boundary components and by implementing more digital approach such as by using upcoming digital-twin (DT) technology for predicting the structural states (e.g., time and location dependent inside/outside thickness temperature, stress, strain, plastic deformation, etc.) and associated fatigue life of a component in real time. Towards this goal Argonne National Laboratory (ANL) with the sponsorship of DOE Light Water Reactor Sustainability (LWRS) program is working on the development of a DT framework that can be used for real time environmental fatigue prediction of reactor components. The DT framework is based on limited experiment-data, Artificial-intelligence (AI) – Machine-Learning (ML) - Deep-Learning (DL) based techniques and Multiphysics-computational-mechanics such as finite element (FE) based modeling tools. Towards this overall goal, following are some of the major contributions made during the FY21: 1) Multiple 82/182 dissimilar metal weld (DMW) specimens (both solid-weld and joint-weld representing the actual reactor multi-metal nozzles) were fatigue tested. The resulting fatigue lives were compared to the NUREG-6909 based best-fit and design fatigue curves. Additionally, the results of 52/152 DMW fatigue specimens (which were recently tested at Republic of Korea under the sponsorship of International Nuclear Energy Research Initiative - INERI program) were compared to the NUREG-6909 based best-fit and design fatigue curves. From the comparison of 82/182 and 52/152 DMW test data with NUREG-6909 best-fit curve, most of the reported test data fall way away from the NUREG-6909 suggested best-fit or mean curve. The NUREG-6909 suggested best-fit curve is the best-fit curve of austenitic stainless steel and due to lack of enough data on Nickel-based welds, this is currently being used for predicting the life of Nickel-alloy-based welded components. However, the above observation may require higher scaling factor (e.g., ASME suggested factor of 20 on cycles rather than the current NUREG-6909 suggested factor of 12 on cycles) for scaling the austenitic-stainless-steel best-fit-curve for estimating the design or safe-life of a welded component. Accordingly, for example, if a DMW component experience a strain amplitude of 0.6% the PWR-water life of the component would be 52 cycles instead of 85 cycles. However, more DMW tests are required to further ascertain the above-mentioned observations. 2) A system level CAD and finite element model were developed which consists of reactor pressure vessel (RPV), part of steam generator (SG), part of pressurizer (PRZ), hot leg (HL), and surge line (SL). This is with detailed nozzle geometry and thermal-mechanical material properties of different metals to simulate realistic thermal-mechanical stress under connected system global thermal-mechanical boundary conditions. 3) Different system level heat transfer analyses were performed with estimation of relevant heat transfer coefficients. The resulting data were used in subsequent system level thermal-mechanical stress analysis and for generating spatial-temporal training and validation data for a system level digital-twin based temperature predictor. Transient heat transfer analyses were performed considering thermal boundary condition under design-basis (DB) loading and EDF (Électricité de France) data-based grid-load-following (EDF-GLF) loading cycles. 4) System level thermal-mechanical stress analysis was performed for identifying damage-prone hotspots and for future extension of the model for cyclic state prediction. From the system-level model simulation under DB loading cycle it is found that HL and the SL nozzle that connect to the HL can experience significant stress and strain and could be one of the weakest links in the overall reactor coolant system (RCS). 5) An AI/ML based DT model was developed for multi-time-series temperature prediction at any inside/outside thickness locations of PWR pressure boundary components. This is by using Recurrent-neural-network (RNN) and keras machine learning libraries. The RNN model was validated against two laboratory test-based data sets with one obtained through ANL’s in-air fatigue test system and other through PWR-water test loop. The experimentally validated DT model further validated against FE model results to predict thermal scarification related spatialtemporal temperatures at random locations of a component. The well validated DT model was then used for demonstrating spatial-temporal temperature prediction under 100+ years of reactor operation subjected to combined DB, EDF-GLF and randomized grid-load-following (RANDOMGLF) loading Cycles. The expert-elicitation DT model framework was developed assuming field/input/process measurements can be available from a few existing plant sensors and can readily be used by the NPP operators. The above temperature prediction model will feed to the next-step stress analysis model based on which the life of a component can be predicted in realtime, which is one of our future works.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hybrid AI-ML and FE-based Digital Twin Predictive Modeling Framework for a PWR Coolant System Components: Updates on Multi-Time-Series-3D-Location Dependent Usages Factor Prediction

The long-term operation (LTO) of nuclear power plants (NPP) beyond their original design life of 40 years can lead to more material damage associated with cyclic fatigue under thermal-mechanical loading cycles and associated long-term exposure of reactor material to the deleterious reactor-coolant environments. However, under this LTO condition, the reactor components can still safely operate but may require more frequent Nondestructive Evaluation (NDE) of reactor components. Requiring frequent NDE inspections may lead to frequent NPP shutdowns which can lead to power outages and additional NDE inspection cost-related economic loss. The economic loss can be minimized by reducing uncertainty in life estimation of safety-critical pressure boundary components and by implementing a more digital approach such as using upcoming digital-twin (DT) technology for predicting the structural states (e.g., time and location dependent inside/outside thickness temperature, stress, strain, plastic deformation, etc.) and associated fatigue life of a component in real time. The DT framework is based on limited experimental data, Artificial-intelligence (AI)-Machine-Learning (ML) and multiphysics-computationalmechanics such as finite element- (FE) based models. Given the real-time thermal-hydraulic process measurements from several existing plant sensors, the overall goal of the DT framework is to predict the cumulative usages factors or equivalent fatigue lives in real time and at any random 3D location of the components. This includes inaccessible locations such as inside the thickness or location of a component. This prediction can be at thousands to millions of 3D point clouds or locations like conventional FE-based models, but without running an FE model in real time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of SCALE and MELCOR for a generic pebble bed fluoride high-temperature reactor

This paper presents the development and application of SCALE and MELCOR models for a fluoride salt-cooled high-temperature reactor (FHR) based on publicly available specifications. SCALE version 6.3beta15 was used to generate power distributions and decay heat curves, and MELCOR version 2.2.18019 was used to calculate the thermal hydraulic response of an assumed FHR primary system. Here, an approach was developed for determining the equilibrium state of the core using depletion of a core slice model and blending of fuel compositions at different burnups to provide three-dimensional fuel composition in the core. Results compared between a core with entirely fresh fuel and one with an equilibrium fuel composition revealed that the equilibrium core led to lower steady-state temperatures but slower cooldown during a loss of flow accident (LOFA). A sensitivity study was then conducted to explore the transient response of our FHR system to variations in thermal hydraulic parameters of the system using the equilibrium core. The inlet temperature, graphite thermal conductivity, and SCRAM time all provided significant control over peak fuel and coolant temperatures. Uncertainties in radionuclide decay data in SCALE were used to perform a decay heat sensitivity study, and we found that uncertainties in decay heat led to negligible impact on peak temperatures during the course of the transient. In all cases evaluated, the observed peak fuel temperatures remained approximately 700 K below anticipated failure limits for the LOFA.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Progress Towards the Validation of a new RELAP5-3D model of the High Temperature Test Facility

Validation is a key step in the development of any type of systems model. As the next generation of reactors approaches, the need for codes that have been validated for these new types of systems continues to grow. An example of a prominent option is the Reactor Excursion Leak Analysis Program (RELAP5-3D), developed by Idaho National Laboratory. This code was developed for the purpose of systems level thermal-hydraulic modeling of light water reactors (LWRS) and postulated transients that can occur in LWRS.RELAP5-3D has been substantially validated against LWR data. Due to its long history as a reactor safety analysis tool, there has been an effort to adapt RELAP5-3D for the purposes of advanced reactor concepts such as prismatic high-temperature gas-cooled reactors (HTGRs). However, RELAP5-3D has not nearly been validated and verified for HTGRs to the degree of LWRs, warranting verification and validation opportunities with computational benchmarks and existing experimental facilities. Examples of such facilities include the modular high-temperature gas-cooled reactor (MHTGR) 350 and the high temperature engineering test reactor (HTTR) from Japan. The MHTGR 350 is a benchmark design concept for code-to-code verification purposes; therefore, it does not provide any experimental data for validation opportunities The HTTR provides useful multiphysics validation data but does not have the in-core instruments to generate thermal-hydraulic experimental data to help with RELAP5-3D validation. Consequently, a facility that could provide key in-core temperatures for thermal-hydraulic validation was still needed. The High Temperature Test Facility (HTTF) is an integral effects facility for HTGR thermal hydraulics developed and operated by Oregon State University. HTTF represents ¼ length scale of the General Atomics MHTGR and is rated for a total power of 2.2 MW. Axially, the core consists of an upper and lower reflector and 10 blocks, numbered from bottom to top (Block 1 is right above lower reflector). The core is heated via graphite resistive heater rods, with respective channels distributed throughout the core. The primary coolant is helium and heat can radiate out of the core to the reactor cavity cooling system (RCCS), which is cooled by water. The primary purpose of the facility is to investigate pressurized conduction cooldown (PCC) and depressurized conduction cooldown (DCC) transients, which are also referred to as the pressurized and depressurized loss of forced cooling respectively. Two experiments were chosen to perform the validation study with a RELAP5-3D model of HTTF. These experiments are PG-27 (PCC) and PG-29 (DCC). These were chosen based off of the quality of available experimental data before and during the experiment which led to their inclusion in the HTGR Thermal Hydraulics Benchmark.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of nuclear data covariance libraries on uncertainty quantification of sodium cooled fast reactor simulation

Uncertainty quantification in core modelling to assess reactor performance is a regular practice to identify design safety limits. Best-estimate plus uncertainty (BEPU) methods are commonly used to propagate uncertainties to core responses from input parameters, characterized by variance-covariance libraries. This study evaluates the impact of different covariance libraries on the uncertainty associated with core safety parameters and their propagation through reactor transient modelling for a metallic core (ABR-1000). The COMAC-1.0, COMMARA-2.0, and COMMARA-2.1 covariance libraries are used to propagate nuclear data uncertainties to neutron feedback coefficients using the Generalized Perturbation Theory, then through transient safety analyses to establish the confidence interval for safety performance of the reactor using stochastic sampling. The considered transients include Unprotected Transient Over Power and Unprotected Loss Of Flow. Most influential nuclide and reaction pairs in different variance-covariance libraries are identified and their impact on the uncertainty of safety parameters are evaluated. Significant differences were observed between uncertainties from COMAC compared to COMMARA libraries. Uncertainties from COMMARA libraries were consistently larger than COMAC for all cases. For structure, coolant density feedback coefficients and control rod worth, total nuclear data uncertainties were approximately 50% larger for COMMARA than COMAC. Differences were also observed in identification of top contributors of uncertainty in terms of reaction-cross sections. For instance, largest contribution to total uncertainty of radial expansion coefficient from COMMARA-2.0 and 2.1 originates from Na{sup 23} P1 Elastic cross section (0.81%) but from Pu{sup 239} Fission (0.53%) with COM C-1.0. Such differences are evaluated in this research for all quantities of interest. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Graphite-Embedded High-Performance Insulated Metal Substrate for Wide-Bandgap Power Modules

Emerging wide-bandgap (WBG) semiconductor devices such as silicon carbide (SiC) metal–oxide semiconductor field-effect transistors (MOSFETs) and gallium nitride high-electron-mobility transistors can handle high power in reduced semiconductor areas better than conventional Si-based devices owing to superior material properties. With increased power loss density in a WBG-based converter and reduced die size in power modules, thermal management of power devices must be optimized for high performance. Here, we present a graphite-embedded insulated metal substrate (thermally-annealed-pyrolytic-graphite-embedded insulated metal substrate—IMSwTPG) designed for WBG power modules. Theoretical thermal performance analysis of graphite-embedded metal cores is presented, with design details for IMSwTPG with embedded graphite to replace a direct-bonded copper (DBC) substrate. The proposed IMSwTPG is compared with an aluminum nitride-based DBC substrate using finite-element thermal analysis for steady-state and transient thermal performance. The solutions’ thermal performances are compared under different coolant temperature and thermal loading conditions, and the proposed substrate's electrical performance is validated with static and dynamic characterization. Using graphite-embedded substrates, junction-to-case thermal resistance of SiC MOSFETs can be reduced up to 17%, and device current density can be increased by 10%, regardless of the thermal management strategy used to cool the substrate. Reduced transient thermal impedance of up to 40% of dies owing to increased heat capacity is validated in transient thermal simulations and experiments. The half-bridge power module's electrical performance is evaluated for on -state resistance, switching performance, and switching loss at three junction temperature conditions. The proposed substrate solution has minimal impact on conduction and switching performance of SiC MOSFETs.

42 ENGINEERING↗

Final Report on Predictive Analyses of PRD as Function of Anomalies

This report summarizes the work completed in FY-2024 to analyze the power reactivity decrement (PRD) concepts of the ARC-100 core. The PRD has been traditionally defined by the reactivity change from a hot zero power (HZP) to a particular power. Consequently, the PRD accounts for the core reactivity changes due to increase coolant temperature gradient axially and radially across the core, and increased fuel temperature. The coolant temperature gradient leads to sodium and structure density changes, to radial core expansion from assembly flowering and bowing (due to axial and radial temperature gradients within the assemblies), and to control rod driveline thermal expansion. The fuel temperature increase associated with coolant temperature and power increases leads to Doppler effect and axial thermal expansion. In this work, the normal operating Hot Full Power (HFP) state is the only power level of interest, so analyses focus on the PRD calculated from HZP to HFP. The PRD has been used to assess the reactor safety features asymptotically in unprotected accident scenarios, including the loss of heat sink (LOHS), loss of flow (LOF), and transient overpower (TOP) without scram. The PRD concept relies on the “global” reactivity coefficients A, B, and C that are estimated based on “individual” reactivity effects (Doppler, sodium density, etc.). The objectives of this work are: 1) to improve and verify the methodology used to calculate the ABC coefficients used in the PRD, 2) to assess if the PRD can be used to reliably identify abnormal events. This report fulfills the FY-2024 scope of WBS#1.15.8.3 activity, “ANL0120 – Predictive Analyses of PRD as function of deformation”. The PRD concept is described in Sections 2. Additional effort in refining the methodology for core bowing modeling is performed in Sections 3. Then, two verification exercises are proposed in Section 4 to benchmark these coefficients based on direct neutronic-only calculations and on dynamic core transient simulations. Finally, the PRD approach is assessed for the detection of several unexpected events, such as primary flow perturbation or improper fuel loading, in Section 5.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development and Integration of a Stochastic Clad Damage Propagation Model into PRONGHORN-SC Subchannel Analysis Code

The failure of fuel pins in nuclear reactors is intrinsically stochastic. Typically, a combination of variation in manufacturing that affects the material characteristics and the fuel assembly dimensions, variation in operating conditions, such as local power, coolant flow rate, and irradiation induced changes in material properties lead to a large uncertainty in failure margin of the fuel pins. Failure, therefore, may occur in exceptional pins with adverse combinations of these variations. Upon a metal fuel pin (U-Pu-Zr/HT9) failure, depressurization of the fuel pin takes place by release of fission gas, liquid sodium bond, and potentially solid fuel particles or molten/eutectic fuel droplets through the hole in cladding. The effect of a fission gas jet on neighbor fuel pins and possible propagation of a clad damage during normal operation was studied experimentally in 1970s and it was found that the post-failure fission gas jet insulates the jet impingement area of the target fuel pin surface and could increase the target pin’s surface temperature by as much as 100 – 200 K during the failed pin depressurization. It was concluded that the effect should not lead to fuel pin failure propagation during normal operation. In accident scenarios of sodium and lead fast reactors such as Unprotected Loss-Of-Flow (ULOF) or Unprotected Transient Over Power (UTOP), the fuel pins can be subjected to higher clad temperatures and fuel pin pressures or fuel clad mechanical/chemical interaction where thermal creep margin becomes significantly lower compared to the normal operation conditions. Therefore, possible stochastic failure and the post-failure fission gas/fuel jet impingement could be critical in order to predict fuel pin failure propagation. Pin depressurization due to fission gas release may degrade the heat transfer by formation of a gas blanket on a neighboring pin surface, which is a local phenomenon, and by causing coolant flow deceleration and starvation, which could affect a surrounding region as well. Furthermore, the potential presence of solid fuel particles or molten fuel at the time of clad failure could boost post-failure jet induced degradation even further. The present study models the U-Pu-Zr/HT9 metal fuel pin failure and stochastic clad damage propagation by biased sampling based on a Cumulative Damage Fraction (CDF) type clad failure criterion and the normal distribution of fuel failure probability density as a function of logarithm of Cumulative Damage Fraction. In addition, the effect of post-failure fission gas jet on heat transfer degradation is modeled for the target pins. This model is called stochastic Clad Damage Propagation (CDAP). The CDAP model is now fully integrated into developmental version of PRONGHORN-SC subchannel analysis code, allowing for modeling local failures and its propagation potential. Section 2 describes the components of the CDAP models. Section 3 describes the model implementation to PRONGHORN-SC and input specifications. Section 4 describes the CDAP model validation coupled to PRONGHORN-SC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗