Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laboratory analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Explicit Dynamic Impact Analysis of the Building 3525 Packages

The safe transport and handling of radioactive material containers is critical to ensure the protection of personnel, facilities, and the environment. Accidental drops during handling pose a significant hazard, necessitating robust design and analysis to mitigate potential consequences. This study presents an explicit dynamic impact analysis of two container designs, the Baby Sugarman and the Core Conduction Cooldown Test Facility (CCCTF) Tall Boy, used in Building 3525 at Oak Ridge National Laboratory. The analysis employed nonlinear finite element modeling in LS-DYNA to simulate free-fall impacts from a height of 16.5 ft across eight critical orientations. The study evaluated deformation, strain failure, and shielding integrity under these extreme conditions. Results demonstrated that both designs maintain structural integrity, with no breaches or loss of shielding under specified administrative controls. Notably, a maximum shielding loss of 10 lbs was observed during a top-corner drop, highlighting the need to limit drop heights to less than 1 ft for certain orientations. These findings underscore the effectiveness of engineering controls and design measures in preventing containment breaches and ensuring compliance with safety requirements. This work provides a comprehensive methodology for impact analysis, contributing valuable insights to the field of radioactive materials packaging and transportation safety.

Martinez, Oscar [ORNL] (ORCID:0000000181814046)↗

Development of Ionic Based Fluid to Improve Fluid Hydraulics in Enhanced Geothermal Systems

This research advances the field of geothermal energy by developing and evaluating novel fluid systems designed explicitly for high-temperature subsurface environments to enhance fracture flow distribution. The project integrates chemical synthesis, environmental assessment, rheological testing, microfluidic analysis, and reservoir-scale laboratory testing and analysis to identify optimal ionic and nonionic fluids for Enhanced Geothermal Systems (EGS).

15 GEOTHERMAL ENERGY↗

Self-Sealing Wet Chemistry Cell for Field Analysis

In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes, especially when detecting low concentration organic molecules that may identify extraterrestrial life. Wet chemistry based instruments are the techniques of choice for most laboratory- based analysis of organic molecules due to several factors including less fragmentation of fragile biomarkers, and ability to concentrate target species resulting in much lower limits of detection. Development of an automated wet chemistry preparation system that can operate autonomously on Earth and is also designed to operate under Martian ambient conditions will demonstrate the technical feasibility of including wet chemistry on future missions. An Automated Sample Processing System (ASPS) has recently been developed that receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species, and delivers sample to multiple instruments for analysis (including for non-organic soluble species). The key to this system is a sample cell that can autonomously function under field conditions. As a result, a self-sealing sample cell was developed that can autonomously hermetically seal fines and powder into a container, regardless of orientation of the apparatus. The cap is designed with a beveled edge, which allows the cap to be self-righted as the capping motor engages. Each cap consists of a C-clip lock ring below a crucible O-ring that is placed into a groove cut into the sample cap.

Beegle, Luther W.↗

The cleanroom case study in the Software Engineering Laboratory: Project description and early analysis

This case study analyzes the application of the cleanroom software development methodology to the development of production software at the NASA/Goddard Space Flight Center. The cleanroom methodology emphasizes human discipline in program verification to produce reliable software products that are right the first time. Preliminary analysis of the cleanroom case study shows that the method can be applied successfully in the FDD environment and may increase staff productivity and product quality. Compared to typical Software Engineering Laboratory (SEL) activities, there is evidence of lower failure rates, a more complete and consistent set of inline code documentation, a different distribution of phase effort activity, and a different growth profile in terms of lines of code developed. The major goals of the study were to: (1) assess the process used in the SEL cleanroom model with respect to team structure, team activities, and effort distribution; (2) analyze the products of the SEL cleanroom model and determine the impact on measures of interest, including reliability, productivity, overall life-cycle cost, and software quality; and (3) analyze the residual products in the application of the SEL cleanroom model, such as fault distribution, error characteristics, system growth, and computer usage.

Green, Scott↗

Nimbus/TOMS Science Data Operations Support

Projected goals include the following: (1) Participate in and provide analysis of laboratory and in-flight calibration of LTV sensors used for space observations of backscattered LTV radiation; (2) Provide support to the TOMS Science Operations Center, including generating instrument command lists and analysis of TOMS health and safety data; (3) Develop and maintain software and algorithms designed to capture and process raw spacecraft and instrument data, convert the instrument output into measured radiance and irradiances, and produce scientifically valid products; (4) Process the TOMS data into Level 1, Level 2, and Level 3 data products; (5) Provide analysis of the science data products in support of NASA GSFC Code 916's research.

Source record↗

Nimbus/TOMS Science Data Operations Support

1. Participate in and provide analysis of laboratory and in-flight calibration of UV sensors used for space observations of backscattered UV radiation. 2. Provide support to the TOMS Science Operations Center, including generating instrument command lists and analysis of TOMS health and safety data. 3. Develop and maintain software and algorithms designed to capture and process raw spacecraft and instrument data, convert the instrument output into measured radiance and irradiances, and produce scientifically valid products. 4. Process the TOMS data into Level 1, Level 2, and Level 3 data products. 5. Provide analysis of the science data products in support of NASA GSFC Code 916's research.

Childs, Jeff↗

Analysis of Designs of Space Laboratories

A report presents a review of the development of laboratories in outer space, starting from the pioneering Skylab and Salyut stations of the United States and the former Soviet Union and progressing through current and anticipated future developments. The report includes textual discussions of space station designs, illustrated with drawings, photographs, and tables. The approach taken in the review was not to provide a comprehensive catalog of each space laboratory and every design topic that applies to it, but, rather, to illustrate architectural precedents by providing examples that illustrate major design problems and principles to be applied in solving them. Hence, the report deemphasizes information from the most recent space-station literature and concentrates on information from original design reports that show how designs originated and evolved. The most important contribution of the review was the development of a methodology, called "units of analysis," for identifying and analyzing design issues from the perspectives of four broad domains: laboratory science, crew, modes of operations, and the system as a whole.

Cohen, Marc M.↗

Rotating Balance Design Methodology

Several upcoming wind tunnel turbofan tests at NASA Glenn Research Center (GRC) require new rotating balances to meet test needs. As the name implies, a rotating balance rotates with the fan providing direct thrust and torque measurements to estimate fan efficiency and performance. One main feature of the new rotating balances requested by GRC, is a more compact design compatible with high bypass fans that are of interest for gains in fuel efficiency. In support of this measurement need, NASA Langley Research Center (LaRC) developed an understanding and methodology for the design of two-component rotating balances. During the development of the methodology, a thorough FEA analysis was conducted, torque analysis of laboratory test specimens, and a study of analytical models were investigated. This presentation will summarize the developed rotating balance design methodology that is detailed in a NASA Technical Memorandum. This TM will detail the analysis required to design, and fabricate a two-component spoke-type rotating balance.

Kenneth Toro↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Break Point Distribution on Chromosome 3 of Human Epithelial Cells exposed to Gamma Rays, Neutrons and Fe Ions

Most of the reported studies of break point distribution on the damaged chromosomes from radiation exposure were carried out with the G-banding technique or determined based on the relative length of the broken chromosomal fragments. However, these techniques lack the accuracy in comparison with the later developed multicolor banding in situ hybridization (mBAND) technique that is generally used for analysis of intrachromosomal aberrations such as inversions. Using mBAND, we studied chromosome aberrations in human epithelial cells exposed in vitro to both low or high dose rate gamma rays in Houston, low dose rate secondary neutrons at Los Alamos National Laboratory and high dose rate 600 MeV/u Fe ions at NASA Space Radiation Laboratory. Detailed analysis of the inversion type revealed that all of the three radiation types induced a low incidence of simple inversions. Half of the inversions observed after neutron or Fe ion exposure, and the majority of inversions in gamma-irradiated samples were accompanied by other types of intrachromosomal aberrations. In addition, neutrons and Fe ions induced a significant fraction of inversions that involved complex rearrangements of both inter- and intrachromosome exchanges. We further compared the distribution of break point on chromosome 3 for the three radiation types. The break points were found to be randomly distributed on chromosome 3 after neutrons or Fe ions exposure, whereas non-random distribution with clustering break points was observed for gamma-rays. The break point distribution may serve as a potential fingerprint of high-LET radiation exposure.

Hada, M.↗

A Review of the Handheld X-Ray Fluorescence Spectrometer as a Tool for Field Geologic Investigations on Earth and in Planetary Surface Exploration

X-ray fluorescence (XRF) spectroscopy is a well-established and commonly used technique in obtaining diagnostic compositional data on geological samples. Recently, developments in X-ray tube and detector technologies have resulted in miniaturized, field-portable instruments that enable new applications both in and out of standard laboratory settings. These applications, however, have not been extensively applied to geologic field campaigns. This study investigates the feasibility of using developing handheld XRF (hXRF) technology to enhance terrestrial field geology, with potential applications in planetary surface exploration missions. We demonstrate that the hXRF is quite stable, providing reliable and accurate data continuously over a several year period. Additionally, sample preparation is proved to have a marked effect on the strategy for collecting and assimilating hXRF data. While the hXRF is capable of obtaining data that are comparable to laboratory XRF analysis for several geologically-important elements (such as Si, Ca, Ti, and K), the instrument is unable to detect other elements (such as Mg and Na) reliably. While this limits the use of the hXRF, especially when compared to laboratory XRF techniques, the hXRF is still capable of providing the field user with significantly improved contextual awareness of a field site, and more work is needed to fully evaluate the potential of this instrument in more complex geologic environments.

Young, Kelsey E.↗

Explicit relations in Bowen fluorescence - Applications to nebulae, the sun, Scorpius X-1, and laboratory plasmas

A general analysis of the fluorescent process is described which emphasizes the differing roles of escape probabilities in one-component and two-component gases, and the existence of discrete fluorescent saturation regimes. Explicit formulas are obtained and discussed for astrophysical Bowen fluorescence, as a concrete example, with applications to planetary nebulae, the solar atmosphere and the X-ray binary Sco X-1. An expression is also provided and evaluated for the profile overlap integral involved in the pumping process. A preliminary conclusion is deduced that densities in the fluorescent line-emitting regions of nebular sources may be higher than those derived from forbidden line ratios. The analysis is extended to a proposed laboratory investigation which would exploit the possibility of controlling the determining factors in the fluorescent process, i.e., O III/He II abundance ratio, optical depth, and photoexciting radiation field.

Kastner, S. O.↗

Microgravity acceleration measurement environment characterization

The Space Acceleration Measurement System (SAMS) is a general-purpose instrumentation system designed to measure the accelerations onboard the shuttle Orbiter and shuttle/Spacelab vehicles. These measurements are used to support microgravity experiments and investigations into the microgravity environment of the vehicle. Acceleration measurement can be made at locations remote from the SAMS main instrumentation unit by the use of up to three remote triaxial sensor heads. The SAMS was developed by NASA's Lewis Research Center (LeRC) in support of NASA's microgravity science programs. In the past, numerous acceleration measurement systems have flown on various space missions. These systems were tailored to measure accelerations for a narrow set of requirements and were limited in bandwidth, dynamic range, and recording capability. In addition, these systems were mission-peculiar and not easily modified for other applications or missions. The result has been an inability to accurately assess the expected microgravity environment prior to a mission for a particular experiment and/or location. The prime science objective for SAMS on the SL-J mission will be to measure the accelerations experienced by a multitude of experiments in the two racks of the Japanese First Materials Processing Test (FMPT). The FMPT consists of a variety of materials science and life science experiments contained in racks no. 7 and no. 10. The SAMS data will be made available to the FMPT principal investigators after the mission for their analysis with the FMPT data. A secondary science objective for SAMS will be the characterization of the acceleration environment of the Spacelab module. This will include an analysis of the acceleration transfer function of the Spacelab module which will utilize the FMPT acceleration measurement along with measurements at the rack no. 9 structure. Another analytical effort to be undertaken is a general characterization of the acceleration environment of the Spacelab as an orbiting laboratory. These analysis efforts will be in conjunction with similar measurements and analyses on other SAMS Spacelab missions.

Delombard, Richard↗

Evaluation of atmospheric trace constituent sensors operating from remote space and airborne platforms

A laboratory gas analysis system was developed specifically to make trace level measurements of carbon monoxide. To assure that the data collected with this system are correctly aligned with other established methods for making these measurements, an intercalibration study was conducted. The calibration gas was analyzed by the various participating laboratories and found to contain 1.28 ppm CO. Samples were collected at 25 deg, 35 deg, and 45 deg N for profile data to study the variation in concentrations of CO and CH4 as a function of altitude and latitude in continental air over the eastern seaboard of the United States. The experiment was repeated several months later to determine if there were seasonally dependent variations in the CO and CH4 concentrations.

Condon, E.↗

The Return of Astromaterials to Earth Over the Next Decade

We are entering a new and golden age of sample return missions. In the coming decade we will harvest samples from Comet P/Wild II and interstellar dust courtesy of the STARDUST Mission (Brownlee et al., 1997), an asteroid (probably 4660 Nereus or 1989ML) by the ISAS MUSES-C Mission (ISAS, 1997), and solar wind by the Genesis Mission. A sample return from Mars is also envisioned as early as 2008, and possibly one from the two moons of Mars. It is, however, sobering to realize that MUSES-C aims to return 3-10 g of sample, STARDUST will provide micrograms of comet and interstellar dust, and Genesis will harvest only few micrograms of atoms. The diminutive size of the returning samples may be a source of concern for petrologists used only to looking at hefty lunar rocks and meteorites. How much sample is really needed to achieve prime science objectives, while maintaining a cost effective mission? The range of geological processes that we will want to address with these samples is staggering, encompassing not merely the entire history of the Solar system, but the history of the elements themselves. The interstellar processes include element formation, production and interactions with radiation, formation of organics, grain condensation and evolution, and interactions with magnetic fields. In the pre-accretionary (nebular) environment we wish to understand grain condensation, evaporation and recondensation, shock, radiation processing, solar energetic particle implantation, gas composition, the magnetic environment, and the evolution of organics. Finally, for solid bodies we wish to examine accretion history, shock, brecciation, impact gardening, metamorphism, aqueous alteration, weathering, exposure history, volcanism, fumarolic activity, differentiation, the magnetic environment, atmosphere evolution, and the evolution of organics. Since 1981, NASA has supported asteroid and comet science by collecting dust grains from these bodies in the stratosphere, and making them available for analysis in laboratories worldwide (Warren and Zolensky, 1994). Over the succeeding 17 years, many new techniques have been developed for these painstaking analyses, by at least 24 different laboratories across the globe. Despite the fact that the particle supply has always exceeded the demand, the painstaking efforts required for most of the nano-scale analyses have resulted in only 1520 grains having been analyzed, with a total mass of only 0.52 micrograms. Thus we really require less sample for analysis than one might imagine.

Zolensky, Michael E.↗

Results of the second Round Robin on opening-load measurement conducted by ASTM Task Group E24.04.04 on crack closure measurement and analysis

A second experimental Round Robin on the measurement of the crack opening load in fatigue crack growth tests has been completed by the ASTM Task Group E24.04.04 on Crack Closure Measurement and Analysis. Fourteen laboratories participated in the testing of aluminum alloy compact tension specimens. Opening-load measurements were made at three crack lengths during constant Delta K, constant stress ratio tests by most of the participants. Four participants made opening-load measurements during threshold tests. All opening-load measurements were based on the analysis of specimens compliance behavior, where the displacement/strain was measured either at the crack mouth or the mid-height back face location. The Round Robin data were analyzed for opening load using two non-subjective analysis methods: the compliance offset and the correlation coefficient methods. The scatter in the opening load results was significantly reduced when some of the results were excluded from the analysis population based on an accept/reject criterion for raw data quality. The compliance offset and correlation coefficient opening load analysis methods produced similar results for data populations that had been screened to eliminate poor quality data.

Phillips, E. P.↗

Meteorological Instruction Software

At Florida State University and the Naval Postgraduate School, meteorology students have the opportunity to apply theoretical studies to current weather phenomena, even prepare forecasts and see how their predictions stand up utilizing GEMPAK. GEMPAK can display data quickly in both conventional and non-traditional ways, allowing students to view multiple perspectives of the complex three-dimensional atmospheric structure. With GEMPAK, mathematical equations come alive as students do homework and laboratory assignments on the weather events happening around them. Since GEMPAK provides data on a 'today' basis, each homework assignment is new. At the Naval Postgraduate School, students are now using electronically-managed environmental data in the classroom. The School's Departments of Meteorology and Oceanography have developed the Interactive Digital Environment Analysis (IDEA) Laboratory. GEMPAK is the IDEA Lab's general purpose display package; the IDEA image processing package is a modified version of NASA's Device Management System. Bringing the graphic and image processing packages together is NASA's product, the Transportable Application Executive (TAE).

Source record↗

Gem Analysis

World Gem Laboratory, Inc.'s cathodoluminoscope is an instrument that magnifies a specimen and produces heat-generated light emissions that bring out features important in gemological analysis. It can indicate whether a stone can be successfully cut, useful in the study of growth and strain patterns in diamonds, detection of dyes in jade, and analysis of the growth and structure of rubies and sapphires. In combination with other tests these analyses can separate synthetic from natural gems.

Source record↗