Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid helium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Toughness Testing for Liquid Hydrogen And Helium Temperatures - Validation of Austenitic Stainless Steels for 4K (-452F) Use

This presentation is an Existing Code Requirement: Charpy impact test at a temperature no higher than the design minimum temperature. The Current Practice: is not clear, the indications are that testing is sometimes performed at -320F (liquid nitrogen or "LN2") for that and all lower temperatures. In some cases testing is probably not performed and CGA indicated successful operation of systems at -453F without required test. The Ballot activity: C&S Connect Record 13-341, Ballot 13-1746, initially proposed Charpy testing (lateral expansion criteria) at -320F to validate use at -425 (liquid helium or "LHe"). and PTCS Proposal..

Greulich, Owen R.↗

Numerical Studies of Properties of Confined Helium

We carry out state of the art simulations of properties of confined liquid helium near the superfluid transition to a degree of accuracy which allows to make predictions for the outcome of fundamental physics experiments in microgravity. First we report our results for the finite-size scaling behavior of heat capacity of superfluids for cubic and parallel-plate geometry. This allows us to study the crossover from zero and two dimensions to three dimensions. Our calculated scaling functions are in good agreement with recently measured specific heat scaling functions for the above mentioned geometries. We also present our results of a quantum simulation of submonolayer of molecular hydrogen deposited on an ideal graphite substrate using path-integral quantum Monte Carlo simulation. We find that the monolayer phase diagram is rich and very similar to that of helium monolayer. We are able to uncover the main features of the complex monolayer phase diagram, such as the commensurate solid phases and the commensurate to incommensurate transition, in agreement with the experiments and to find some features which are missing from the experimental analysis.

Manousakis, Efstratios↗

Superfluid helium 2 liquid-vapor phase separation: Technology assessment

A literature survey of helium 2 liquid vapor phase separation is presented. Currently, two types of He 2 phase separators are being investigated: porous, sintered metal plugs and the active phase separator. The permeability K(P) shows consistency in porous plug geometric characterization. Both the heat and mass fluxes increase with K(P). Downstream pressure regulation to adjust for varying heat loads and both temperatures is possible. For large dynamic heat loads, the active phase separator shows a maximum heat rejection rate of up to 2 W and bath temperature stability of 0.1 mK. Porous plug phase separation performance should be investigated for application to SIRTF and, in particular, that plugs of from 10 to the minus ninth square centimeters to 10 to the minus eighth square centimeters in conjunction with downstream pressure regulation be studied.

Lee, J. M.↗

Leakage Through a Channel Formed by a Gasket, a Sealing Surface, and a Filament Trapped Between Them

Plumbing for the transport of liquid Hydrogen or liquid Oxygen at the Kennedy Space Center (KSC) is very critical. Every piece of hardware for handling such a hazardous cryogen is subject to testing prior to installation and use. Safe, realistic testing of all such hardware is prohibitively expensive, which leads, perforce, to expidients such as: (1) lead testing with non-flammable tracer fluids (e.g, liquid nitrogen) and (2) leak testing with room temperature tracer fluids (e.g. liquid helium). Such expedients undermine the realism of the tests. If however, one could apply rational fluid dynamics methods to derive a general analytical expression with which one could relate the throughput of gaseous Helium through a given leak channel to the throughput of liquid Hydrogen through the same channel, then one could recover much of the information that one would otherwise forfeit through these expedients. These facts lead to the following questions: (1) What would be an example of a generic flaw in a gasket?; and (2) How can one calculate the flow of fluid in it? The report addresses these questions. It considers a particular leak geometry, namely one formed by a gasket, a sealing surface, and a filament trapped between them (so that the cross section of the leak channel is a flat bottomed curvilinear triangle, two sides of which are circular arcs and which has cusps on all three corners).

Russell, John↗

Accelerator commissioning and rare isotope identification at the Facility for Rare Isotope Beams

In 2008, Michigan State University was selected to establish the Facility for Rare Isotope Beams (FRIB). Construction of the FRIB accelerator was completed in January 2022. Phased accelerator commissioning with heavy ion beams started in 2017 with the normal-conducting ion source and radio-frequency quadrupole. In April 2021, the full FRIB driver linear accelerator (linac) was commissioned, with heavy ion beams accelerated to energies above 200 MeV/nucleon by 324 superconducting radiofrequency (SRF) resonators operating at 2 K and 4 K with liquid-helium cooling. Further, in preparation for high-power operation, a liquid lithium charge stripper was commissioned with heavy ion beams up to uranium-238, followed by the simultaneous acceleration of multiple-charge-state heavy ion beams to energies above 200 MeV/nucleon. In December 2021, selenium-84 was produced with the FRIB target using a krypton-86 primary beam, demonstrating FRIB’s capability for scientific discovery.

07 ISOTOPE AND RADIATION SOURCES↗

Design and Development of the Astro-H 3-Stage ADR

The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument provided by NASA/GSFC. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon microcalorimeters operated at 50 mK. The detectors will be cooled by a 3-stage adiabatic demagnetization refrigerator (ADR). The configuration allows the ADR to operate with both a 1.3 K superfluid helium bath and a 4.5 K cryocooler as its heat sink. Initially, when liquid helium is present, the two coldest stages of the ADR will operate in a single-shot mode to cool the detectors from 1.3 K. The 3rd stage may be used to transfer heat from the liquid to the cryocooler to extend its lifetime. When the liquid is depleted, the two warmest stages will operate in a continuous mode to establish a 1.3 K base temperature, from which the cold stage will operate in a single-shot mode to cool the detectors. This paper will describe the design and operating modes of the ADR, as well as details of individual components.

Shirron, Peter J.↗

Cryogenic monocrystalline silicon Fabry-Perot cavity for the stabilization of laser frequency

A 1.6 kg silicon monocrystal was used to make a Fabry-Perot optical cavity operated at cryogenic temperatures. High-resolution thermal expansion measurements were made as the silicon cooled to 4.2 K, in order to characterize the cavity as a length reference standard. A helium-neon laser was then locked to a transmission resonance at liquid-helium temperatures, and the laser frequency tracked the cavity resonance with error fluctuations at the level of 10 Hz/sq rt Hz in the bandwidth dc to 1 Hz. Implications of the combined set of data, thermal expansion plus frequency-tracking fluctuations, for using such a system as a frequency standard are discussed.

Richard, J.-P.↗

Mission definition study for Stanford relativity satellite. Volume 2: Engineering flight test program

The need is examined for orbital flight tests of gyroscope, dewar, and other components, in order to reduce the technical and financial risk in performing the relativity experiment. A program is described that would generate engineering data to permit prediction of final performance. Two flight tests are recommended. The first flight would test a dewar smaller than that required for the final flight, but of size and form sufficient to allow extrapolation to the final design. The second flight would use the same dewar design to carry a set of three gyroscopes, which would be evaluated for spinup and drift characteristics for a period of a month or more. A proportional gas control system using boiloff helium gas from the dewar, and having the ability to prevent sloshing of liquid helium, would also be tested.

Source record↗

Layered Thermal Insulation Systems for Industrial and Commercial Applications

From the high performance arena of cryogenic equipment, several different layered thermal insulation systems have been developed for industrial and commercial applications. In addition to the proven areas in cold-work applications for piping and tanks, the new Layered Composite Insulation for Extreme Environments (LCX) has potential for broader industrial use as well as for commercial applications. The LCX technology provides a unique combination of thermal, mechanical, and weathering performance capability that is both cost-effective and enabling. Industry applications may include, for example, liquid nitrogen (LN2) systems for food processing, liquefied natural gas (LNG) systems for transportation or power, and chilled water cooling facilities. Example commercial applications may include commercial residential building construction, hot water piping, HVAC systems, refrigerated trucks, cold chain shipping containers, and a various consumer products. The LCX system is highly tailorable to the end-use application and can be pre-fabricated or field assembled as needed. Product forms of LCX include rigid sheets, semi-flexible sheets, cylindrical clam-shells, removable covers, or flexible strips for wrapping. With increasing system control and reliability requirements as well as demands for higher energy efficiencies, thermal insulation in harsh environments is a growing challenge. The LCX technology grew out of solving problems in the insulation of mechanically complex cryogenic systems that must operate in outdoor, humid conditions. Insulation for cold work includes equipment for everything from liquid helium to chilled water. And in the middle are systems for LNG, LN2, liquid oxygen (LO2), liquid hydrogen (LH2) that must operate in the ambient environment. Different LCX systems have been demonstrated for sub-ambient conditions but are capable of moderately high temperature applications as well.

thermal conductivity↗

Measurement of C-12, O-16, and Fe-56 charge changing cross sections in helium at high energy, comparison with cross sections in hydrogen, and application to cosmic-ray propagation

We present measurements of the spallation cross sections of carbon, oxygen, and iron in helium and hydrogen, at beam energies from 540 to 1600 MeV/nucleon, performed by exposing liquid helium, CH2, and C targets. Charge changing cross sections are reported for fragments down to Ne for Fe + alpha and Fe + p reactions, and down to B for O + alpha, O + p, C + alpha, and C + p reactions. Alpha- to p-induced cross section ratios (sigma(sub alpha)/sigma(sub p)) are determined at the same energy per nucleon. From these measurements an empirical formula for the (sigma(sub alpha)/sigma(sub p)) ratios is derived and is found in good agreement with available isotopic cross sections data from radioactivity and radiochemical techniques. These results are applied to the propagation of heavy charged cosmic rays in an interstellar medium with a helium to hydrogen abundance ratio of 0.10. It is shown that the Sc-Mn/Fe ratio prediction is decreased relative to the B/C ratio when compared to propagation calculations in a pure hydrogen interstellar medium.

Ferrando, P.↗

Design and development of a leak tight helium II valve with low thermal impact

The Lambda Point Experiment is a precision measurement of the specific heat of liquid helium near the lambda point phase transition, in the low gravity of the space shuttle. It requires a valve for the helium sample chamber that operates at helium II temperature, has minimal thermal disturbance to the rest of the instrument, and is leak tight to helium II. A valve meeting these and all of the other science and engineering requirements of the mission has been developed by Ball. Initially, both torque and pressure actuated valve concepts were considered; the final flight design is pressure actuated. The rational for this decision as well as the rest of the valve design are given. The paper also discusses the manufacturing and testing of the prototype and flight valves. Test data is presented and discussed.

Mills, G. L.↗

Superfluid Helium On-Orbit Transfer (SHOOT) operatons

The in-flight tests and the operational sequences of the Superfluid Helium On-Orbit Transfer (SHOOT) experiment are outlined. These tests include the transfer of superfluid helium at a variety of rates, the transfer into cold and warm receivers, the operation of an extravehicular activity coupling, and tests of a liquid acquisition device. A variety of different types of instrumentation will be required for these tests. These include pressure sensors and liquid flow meters that must operate in liquid helium, accurate thermometry, two types of quantity gauges, and liquid-vapor sensors.

Kittel, P.↗

Superfluid Helium On-Orbit Transfer (SHOOT) operations

The in-flight tests and the operational sequences of the Superfluid Helium On-Orbit Transfer (SHOOT) experiment are outlined. These tests include the transfer of superfluid helium at a variety of rates, the transfer into cold and warm receivers, the operation of an extravehicular activity coupling, and tests of a liquid acquisition device. A variety of different types of instrumentation will be required for these tests. These include pressure sensors and liquid flow meters that must operate in liquid helium, accurate thermometry, two types of quantity gauges, and liquid-vapor sensors.

Kittel, P.↗

Helium jet dispersion to atmosphere

On the event of loss of vacuum guard of superinsulated helium dewar, high rate of heat transfer into the tank occurs. The rapid boiling of liquid helium causes the burst disk to rupture at four atmospheres and consequently the helium passes to the atmosphere through vent lines. The gaseous helium forms a vertical buoyant jet as it exits the vent line into a stagnant environment. Characterization of the gaseous jet is achieved by detailed analysis of the axial and radial dependence of the flow parameters.

Khan, Hasna J.↗

Helium-4 Experiments near T-lambda in a Low-Gravity Simulator

We report our studies of gravity cancellation in a liquid helium sample cell along the lambda-line using a low-gravity simulator facility. The simulator consists of a superconducting magnet capable of producing B(delta-B/delta-z) = 22squareT)/cm. We have verified experimentally that the simulator can cancel gravity to about 0.01g in a cylindrical sample volume of 0.5 cm in diameter and 0.5 cm in height. This allows us to approach more closely the superfluid transition without entering the normal-superfluid two phase region induced by gravity. We also present the measurements of T-c(Q,P): depression of the superfluid transition temperature by a heat current(Q) along the lambda-line (P). The results are consistent with the Renormalization-group theory calculation. Measurements of thermal expansion coefficient in a heat current will also be discussed. The work has been carried out by JPL, California Institute of Technology under contract to NASA.

Liu, Yuanming↗

An ASME-Compliant Helium-4 Evaporation Refrigerator for the SpinQuest Experiment

This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium evaporation refrigerator operated in a fixed target scattering experiment at Fermilab and was engineered to comply with the Fermilab ES&H Manual (FESHM) requirements governing pressure vessels, piping, cryogenic systems, and vacuum vessels. The design is mapped to ASME B31.3 (Process Piping) and the ASME Boiler and Pressure Vessel Code (BPVC) for pressure boundary integrity and overpressure protection, with documented compliance to FESHM Chapters 5031 (Pressure Vessels), 5031.1 (Piping Systems), and 5033 (Vacuum Vessels). This work documents the methodology used to reach compliance and approval for the 4He evaporation refrigerator at Fermilab which the field lacks. Design considerations specific to the high radiation target-cave environment including remotely located instrumentation approximately 20 m from the cryostat are summarized, together with the relief-system sizing methodology used to accommodate transient heat loads from dynamic nuclear polarization microwaves and the high-intensity proton beam. Commissioning data from July 2024 confirms that the system satisfies all thermal performance and safety objectives.

Roberts, Jordan D. [Virginia U.]↗

Magnetic suspension and balance system advanced study

An improved compact design for a superconducting magnetic suspension and balance system for an 8 ft. x 8 ft. transonic wind tunnel is developed. The original design of an MSBS in NASA Cr-3802 utilized 14 external superconductive coils and a superconductive solenoid in the airplane test model suspended in a wind tunnel. The improvements are in the following areas: test model solenoid options, dynamic force limits on the model, magnet cooling options, structure and cryogenic designs, power supply specifications, and cost and performance evaluations. The improvements are: MSBS cost reduction of 28%, weight; reduction of 43%, magnet system ampere-meter reduction of 38%, helium liquifier capacity reduction by 33%, magnet system stored energy reduction by 55%, AC loss to liquid helium reduced by 76%, system power supply reduced by 68%, test coil pole strength increased by 19%, wing magnetization increased by 40%, and control frequency limit increased by 200% from 10 Hz to 30 Hz. The improvements are due to: magnetic holmium coil forms in the test model, better rare earth permanent magnets in the wings, fiberglass-epoxy structure replacing stainless steel, better coil configuration, and new saddle roll coil design.

Boom, R. W.↗

Thermal behavior of the SHOOT gallery arm

The planned Superfluid Helium On-Orbit Transfer (SHOOT) experiment will show the feasibility of resupplying orbiting facilities with liquid helium. The SHOOT experiment, designed for transfer rates of 300 to 800 liters/hr, will use a thermomechanical pump and four screen covered flow channels for fluid acquisition. Cavitation and thermal behavior was examined in ground based tests of the pump and of a full sized channel. A model for estimating the temperature profile at the pump inlet is presented. Large temperature increases in this region can significantly degrade the performance of the fountain pump.

Nissen, J. A.↗