Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Time-Domain Vortex Induced Vibration Modeling of Reference Dynamic Power Cable for the Gulf of Maine

Vortex-induced vibration (VIV) is a phenomenon known to decrease the fatigue life of dynamic power cables used in floating offshore wind systems through increased bending loading cycles. A variety of modeling solutions have been proposed to study this, but none enable fully-coupled simulations leveraging open-source tools. To address this, a time-domain VIV model has been successfully implemented into the open-source mooring dynamics model MoorDyn. The semi-empirical VIV model describes a lift force acting on segments of a flexible cylinder, making it well suited for implementation into MoorDyn. The new capability successfully predicted the frequencies and magnitudes of strain in both steady and oscillating flows when compared to the original validation results and matched peak spectral response when compared to experimental results, verifying successful implementation. MoorDyn with VIV was then leveraged to simulate a 15 MW floating turbine with a dynamic power cable in the Gulf of Maine using OpenFAST for six return periods of combined wind, wave, and current conditions. Increased curvature and tension fluctuations in higher flow speeds were observed when simulating VIV. Maximum tensions and curvatures also increased, with the 500 year conditions violating the curvature factor of safety of 2.0. These results highlight the importance of considering VIV when designing dynamic power cables for the Gulf of Maine, and indicate that cost effective mitigation strategies should be explored for the area. They also demonstrate the utility of this new modeling capability, which provides the first open-source tool for fully coupled time-domain floating offshore wind simulations with dynamic power cable VIV.

17 WIND ENERGY↗

Optimizing Porous Transport Layer Porosity for Proton Exchange Membrane Water Electrolysis

An empirical model is presented that describes anode-side losses related to porous transport layer (PTL) morphology in proton exchange membrane water electrolysis (PEMWE). The model is based on an advanced voltage breakdown analysis that links various overpotentials to PTL morphology. Custom Ti PTLs, spanning uncommonly low porosities (22 - 31%), were fabricated and analyzed with X-ray CT to obtain pore and particle size distributions. Particle size distributions were consistent across samples with an average particle diameter of 12.0?..mu..m, whereas average pore diameters ranged from 6.0 to 7.0?..mu..m. The PTLs were tested in standard PEMWE cell assemblies with anode catalyst loadings of 0.1 mgIr cm-2 to obtain polarization curves, electrochemical impedance spectra, and augmented Tafel analysis. The PTL-dependent anode side losses were deconvoluted and assigned to excess utilization, concentration, ion transport resistance, and electrical contact resistance overpotentials. The data and model reveal an optimal 20 - 28% PTL porosity region where utilization and contact resistance overpotentials are minimized without triggering concentration and ion transport losses related to water deprivation. The optimal PTL porosity depends on the operating current density and is demonstrated at realistic PEMWE water flow rates to establish PTL design guidance for operation at scale.

08 HYDROGEN↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Ecosystem consequences of a nitrogen-fixing proto-organelle

Microscale symbioses can be critical to ecosystem functions, but the mechanisms of these interactions in nature are often cryptic. Here, we use a combination of stable isotope imaging and tracing to reveal carbon (C) and nitrogen (N) exchanges among three symbiotic primary producers that fuel a salmon-bearing river food web. Bulk isotope analysis, nanoSIMS (secondary ion mass spectrometry) isotope imaging, and density centrifugation for quantitative stable isotope probing enabled quantification of organism-specific C- and N-fixation rates from the subcellular scale to the ecosystem. After winters with riverbed-scouring floods, the macroalga Cladophora glomerata uses nutrients in spring runoff to grow streamers up to 10 m long. During summer flow recession, riverine N concentrations wane and Cladophora becomes densely epiphytized by three species of Epithemia, diatoms with N-fixing endosymbionts (proto-organelles) descended from a free-living Crocosphaera cyanobacterium. Over summertime epiphyte succession on Cladophora, N-fixation rates increased as Epithemia spp. became dominant, Cladophora C-fixation declined to near zero, and Epithemia C-fixation increased. Carbon transfer to caddisflies grazing on Cladophora with high densities of Epithemia was 10-fold higher than C transfer to caddisflies grazing Cladophora with low Epithemia loads. In response to demand for N, Epithemia allocates high levels of newly fixed C to its endosymbiont. Consequently, these endosymbionts have the highest rates of C and N accumulation of any taxon in this tripartite symbiosis during the biologically productive season and can produce one of the highest areal rates of N-fixation reported in any river ecosystem.

Marks, Jane C. [Northern Arizona Univ., Flagstaff,↗

Microwave Vortex Motion Characterization of Nb$_{3}$ Sn Coatings for Applications in High Magnetic Fields

In this work, microwave measurements carried out in dielectric-loaded resonators exposed to high magnetic fields are exploited to yield the surface impedance of Nb$_3$ Sn superconducting coatings deposited via two different techniques: vapor tin diffusion, and DC magnetron sputtering. The obtained data lead to qualitative interpretations on both the Nb$_3$ Sn superconducting properties, and vortex-dynamics and pinning, of each coating separately, as well as simple distinctive features when comparing those. When examining the respective surface impedances at varying field, it is expected that the studied films perform at substantially diverse magnitudes of flux-flow resistivity, but also in well-differentiated pinning regimes, yet the obtained surface resistances of both samples are comparable, thus demonstrating that there is room for film optimization at the expense of certain compromise between the parameters involved.

Nb3Sn↗

Material Control & Accounting Modeling Developments for a Generic TRISO Fuel Fabrication Facility

The Material Protection, Accounting, and Control Technologies (MPACT) program utilizes modeling and simulation to assess Material Control and Accountability (MC&A) concerns for a variety of nuclear facilities. The Sandia National Laboratories (SNL)-developed Fissile Facility Flow Modeler (F3M) and the Material Accountancy Performance Indicator Toolkit (MAPIT) have historically provided MPACT with the capability to analyze MC&A approaches for nuclear facilities to determine that these facilities meet regulatory requirements. In FY25, improvements on the application of the F3M and MAPIT tools to simulate a generic TRi-structural ISOtropic (TRISO) fuel fabrication facility were successfully completed. The generic TRISO fuel fabrication F3M model captures the entire TRISO fuel fabrication process and is adaptable to any final TRISO fuel form, including spherical pebbles and cylindrical compacts loaded into graphite prismatic blocks. Comprehensive F3M/MAPIT functionality for the generic TRISO fuel fabrication model has been demonstrated. This modeling framework can be applied to support the U.S. Department of Energy and domestic nuclear industry stakeholders in developing MC&A approaches for advanced fuel fabrication facilities via statistical tests that demonstrate compliance to regulatory requirements.

97 MATHEMATICS AND COMPUTING↗

Analyzing the Effects of Atmospheric Turbulent Fluctuations on the Wake Structure of Wind Turbines and Their Blade Vibrational Dynamics

In recent trends, a rising demand for renewable energy has driven wind turbines to larger proportions, where lighter blade designs are often adopted to reduce the costs associated with logistics and production. This causes modern utility-scale wind turbine blades to be inherently more flexible, and their amplified aeroelastic sensitivity results in complex multi-physics reactions to variant atmospheric conditions, including dynamic patterns of aerodynamic loading at the rotor and vortex structure evolutions within the wake. In this paper, we analyze the influence of inflow variance for wind turbines with large, flexible rotors through simulations of the National Rotor Testbed (NRT) turbine, located at Sandia National Labs’ Scaled Wind Farm Technology (SWiFT) facility in Lubbock, Texas. The Common Ordinary Differential Equation Framework (CODEF) modeling suite is used to simulate wind turbine aeroelastic oscillatory behavior and wind farm vortex wake interactions for a range of flexible NRT blade variations, operating in differing conditions of variant atmospheric flow. CODEF solutions of turbine operation in Steady-In-The-Average (SITA) wind conditions are compared to SITA wind conditions featuring a controlled gust-like pulse overimposed, to isolate the effects of typical wind fluctuations. Finally, simulations of realistic time-varying wind conditions from SWiFT meteorological tower measurements are compared to the solutions of SITA wind conditions. These increasingly complex atmospheric inflow variations are tested to show the differing effects evoked by various patterns of spatiotemporal atmospheric flow fluctuations. An analysis is presented for solutions of wind turbine aeroelastic response and vortex wake evolution, to elucidate the consequences of variant inflow, which pertain to wind turbine dynamics at an individual and farm-collective scale. The comparisons of simulated farm flow for SITA and measured fluctuating wind conditions show that certain regions of the wake contain up to a 12% difference in normalized axial velocity, due to the introduction of wind fluctuations. The findings of this study prove valuable for practical applications in wind farm control and optimization strategies, with particular significance for modern utility-scale wind power plants operating in variant atmospheric conditions.

Farrell, Alayna (ORCID:000000023555720X)↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Machine Learning-Assisted Distribution System Network Reconfiguration Problem

High penetration from volatile renewable energy resources in the grid and the varying nature of loads raise the need for frequent line switching to ensure the efficient operation of electrical distribution networks. Operators must ensure maximum load delivery, reduced losses, and the operation between voltage limits. However, computations to decide the optimal feeder configuration are often computationally expensive and intractable, making it unfavorable for real-time operations. This is mainly due to the existence of binary variables in the network reconfiguration optimization problem. To tackle this issue, we have devised an approach that leverages machine learning techniques to reshape distribution networks featuring multiple substations. This involves predicting the substation responsible for serving each part of the network. Hence, it leaves simple and more tractable Optimal Power Flow problems to be solved. This method can produce accurate results in a significantly faster time, as demonstrated using the IEEE 37-bus distribution feeder. Compared to the traditional optimization-based approaches, a feasible solution is achieved approximately ten times faster for all the tested scenarios.

deep neural networks↗

Highly dense atomic Fe–Ni dual metal sites for efficient CO 2 to CO electrolyzers at industrial current densities

Carbon-supported, atomically dispersed, nitrogen-coordinated metal sites (e.g., Fe and Ni) are arguably the most promising catalysts for the electrochemical reduction of CO 2 to CO due to their unique catalytic properties and the use of earth-abundant elements. However, conventional single metal sites are constrained by their structural simplicity, causing either too weak or too strong absorption/desorption of multiple critical intermediates (e.g., *COOH and *CO). Current catalysts also suffer from ultra-low loadings (<1.0 wt%) of atomic metal active sites in catalysts, leading to inadequate performance for CO 2 -to-CO conversion. Here, we develop dual Ni/Fe metal site catalysts with significantly increased atomically dispersed metal loadings (up to 4.8 wt%). A gas-phase chemical vapor deposition (CVD) approach to introducing single Ni sites was integrated with Fe 2 O 3 /ZIF-8 precursors, followed by an optimal thermal activation. The optimized CVD-Ni/Fe–N–C catalyst exhibited remarkable electrocatalytic performance for the CO 2 reduction to CO in a continuous membrane-electrode-assembly electrolyzer, achieving a maximum CO faradaic efficiency (FE CO ) of 96% at a current density of 700 mA cm −2 in a near-neutral electrolyte. Furthermore, a desirable but challenging acidic flow-cell electrolyzer was designed using this dual metal site catalyst to improve CO 2 utilization, accomplishing a FE CO of up to 95% at a CO partial current density close to 600 mA cm −2 . Density functional theory (DFT) calculations suggest a synergetic effect between Fe–Ni pairs facilitating *COOH intermediate formation and *CO desorption simultaneously during CO 2 to CO conversion. This is key to breaking the linear scaling relationship of conventional single-metal site catalysts during the CO 2 reduction reaction.

36 MATERIALS SCIENCE↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Data-Driven Mean-Corrected Recursive Estimation-Based Optimal DER Dispatch for Distribution System Voltage Control

Recent advances in smart inverters offer opportunities to mitigate adverse grid impacts caused by high penetrations of distributed photovoltaics (PV) in distribution grids, such as voltage violations. Here, this paper proposes a novel measurement-driven optimal power flow (OPF)-based distributed energy resource management system (DERMS) voltage regulation via recursive sensitivity estimation informed coordinated control of distributed PV inverters. The proposed approach leverages available grid and controllable DER measurements, eliminating reliance on system model information while being adaptive and robust to volatile operating conditions. A mean-corrected recursive ridge regression (MCRRR) algorithm is proposed for sensitivity estimation, continuously refining the sensitivity model through a closed-form solution. It effectively manages varying grid operating conditions, such as changes in power injections and topology reconfiguration, to facilitate a time-varying update of the Load Sensitivity Factors (LSF). The proposed approach is formulated as a linear programming (LP) problem and is thus scalable to larger-scale distribution systems. Its effectiveness and efficiency are demonstrated on a realistic distribution feeder with high PV penetrations in Southern California, USA.

14 SOLAR ENERGY↗

Automation-Accelerated Electrolyte Design Mitigates Solubility Competition between Redox-Active Molecules and Supporting Salts

In nonaqueous redox-flow batteries (NRFBs), redox-active organic molecules (ROMs) and supporting salts compete for solvation sites, limiting achievable energy density. We combine automated high-throughput experimentation (HTE) with camera-based saturation monitoring and quantitative NMR to measure paired (ROM, salt) solubilities across single and mixed organic solvents. Using 2,1,3-benzothiadiazole (BTZ) with lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) as a model system, we find that a binary m-xylene/acetonitrile mixture dissolves ≈3 M of both BTZ and LiTFSI─surpassing the previously reported 2 M ceiling for neat acetonitrile─by leveraging complementary solvation (MX is BTZ-philic and salt-phobic; ACN stabilizes LiTFSI). A random-forest model (RMSE ≈ 0.24) trained on solvent descriptors highlights log P and salt concentration as dominant predictors and predicts MX/ACN ≈0.3/0.7 (v/v) to be near-optimal. These formulations retain practical viscosity and ∼5 mS·cm –1 conductivity at high loading. In conclusion, the workflow provides a reproducible, data-centric route to NRFB electrolyte design and motivates an open, standardized dual-solute solubility resource for accelerated electrolyte discovery.

Electrolytes↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Quantum/AI Topology-Aware Latency-Adaptive HPC Workflow Scheduling Optimization

The growing demand for more powerful high-performance computing (HPC) systems has led to a steady rise in energy consumption by supercomputing worldwide. This study is focused on comparing our Application-Topology Mapper (ATMapper) to the popular Simple Linux Utility for Resource Management (SLURM) for the purpose of exploring methods that can further optimize job-scheduling within HPC systems. ATMapper is an Artificial-Intelligence based approach to job-scheduling that is currently being enhanced with quantum annealing (QA) to generate optimal schedules faster. We are applying QA to speedup our ATMapper process to achieve higher computing efficiency, thereby reducing HPC energy consumption. Here, we examine how four job-scheduling approaches perform in processor node assignment when using an example network architecture of 4 interconnected nodes. Using a specialized script, we are assessing the schedule of a computation flow with 11 interdependent tasks. The data movements among nodes were tracked to count for the number of interactions (network hops) between nodes needed to complete the tasks. The total number of hops and the job completion time were then used to quantify the efficiency of the different mapping approaches. In addition to SLURM, we also compare our ATMapper to the QA-enabled LBNL TIGER and the D-Wave Distributed Computing processor assignment approaches. The preliminary results showed that our topology-aware, latency-adaptive ATMapper is significantly more efficient when compared to the other scheduling approaches due to its load-imbalance network allocation. The scheduler displayed a computing efficiency of 53% by performing significantly fewer network hops than its alternatives. By reducing the number of hops, ATMapper was able to perform all 11 tasks by using only 3 nodes out of given 4. This research indicates the potential to use QA/AI for HPC job-scheduling. Later, we will test a SLURM simulator program to draw further comparisons on the effectiveness of ATMapper's scheduling approach. The results of this comparison will serve as a baseline for later improving SLURM's performance using a QA-enhanced ATMapper approach.

Caraveo, Braulio [University of Huston - Clear Lak↗

Towards Immobilized Proton-Coupled Electron Transfer Agents for Electrochemical Carbon Capture from Air and Seawater

Electrochemical CO 2 separation has drawn attention as a promising strategy for using renewable energy to mitigate climate change. Redox-active compounds that undergo proton-coupled electron transfer (PCET) are an impetus for pH-swing-driven CO 2 capture at low energetic costs. However, multiple barriers hinder this technology from maturing, including sensitivity to oxygen and the slow kinetics of CO 2 capture. Here, we use vapor phase chemistry to construct a textile electrode comprising an immobilized PCET agent, poly(1-aminoanthraquinone) (PAAQ), and incorporate it into redox flow cells. This design contrasts with others that use dissolved PCET agents by confining proton-storage to the surface of an electrode kept separate from an aqueous, CO 2 -capturing phase. This system facilitates carbon capture from gaseous sources (a 1% CO 2 feed and air), as well as seawater, with the latter at an energetic cost of 202 kJ/mol CO2 , and we find that quinone moieties embedded within the electrode are more stable to oxygen than dissolved counterparts. Simulations using a 1D reaction-transport model show that moderate energetic costs should be possible for air capture of CO 2 with higher loadings of polymer-bound PCET moieties. The remarkable stability of this system sets the stage for producing textile-based electrodes that facilitate pH-swing-driven carbon capture in practical situations.

Ali, Fawaz↗

Characterizing IHE Response to Multiple Shock Loading

The response of high explosives to shock loading is traditionally measured with a steady loading pressure. In many accident scenarios involving fragment impact, however, a loading duration that is shorter than the build up to detonation may occur. Fragments passing through multiple materials before reaching a high explosive charge may produce loading that is comprised of more than one shock wave. Additionally, the build up to detonation in high explosive corner turning loads the explosive a short duration pressure pulse, since rarefactions can often rapidly overtake the reactive wave. For these reasons, we have studied the response of the insensitive high explosive (IHE) materials PBX 9502 and LX-17 to complex loadings of varied intensity and duration. We refer to a single loading of limited duration as a “thin pulse”, whereas more complex scenarios were studied with an impactor that produces a double shock in the explosive. The following report presents experimental data and analyses of thin pulse shock initiation and double shock experiments designed to guide development of models of Insensitive High Explosives (IHEs) under controlled one-dimensional conditions relevant to accident scenarios and corner turning. Thin pulse shock initiation data on PBX 9502 and LX-17 were obtained under varied pulse duration, pressed density, and temperature conditions in order to probe various parameters essential for the development of a physics-based Cheetah reactive flow hotspot model. In situ pressure gauges provide insight into the degree of reaction in the explosive that are not obtainable with optical PDV measurements or distance measurements such as run to detonation. Double shock data was obtained to inform a Composition Aware Cheetah model which can be applied to any TATB-based IHEs. This model supports efforts to find a new IHE formulation and potentially incorporate new binders into IHE formulations. Simulations of each experiment are included to demonstrate the utility of these focused experiments to developing models of HE behavior. One-dimensional gas gun experiments are essential for characterizing shocked HE behavior and informing HE models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗