Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

Optimal Estimation Inversion of Ionospheric Electron Density from GNSS-POD Limb Measurements: Part II-Validation and Comparison Using NmF2 and hmF2

A growing number of SmallSat/CubeSat constellations with high-rate (50–100 Hz) global navigation satellite system radio occultations (GNSS-RO) as well as low-rate (1 Hz) precise orbit determination (GNSS-POD) limb-viewing capabilities provide unprecedented spatial and temporal sampling rates for ionospheric studies. In the F-region electron density (N 𝑒 ) retrieval process, instead of the conventional onion-peeling (OP) inversion, an optimal estimation (OE) inversion technique was recently developed using total electron content measurements acquired by GNSS-POD link. The new technique is applied to data acquired from the COSMIC-1, COSMIC-2, and Spire constellations. Although both OE and OP techniques use the Abel weighting function in N 𝑒 inversion, OE significantly differs in its performance, especially in the lower F- and E-regions. In this work, we evaluate and compare newly derived data sets using F2 peak properties with other space-based and ground-based observations. We determine the F2 peak N 𝑒 (NmF2) and its altitude (hmF2), and compare them with the OP-retrieved values. Good agreement is observed between the two techniques for both NmF2 and hmF2. In addition, we also utilize autoscaled F2 peak measurements from a number of worldwide Digisonde stations (∼30). The diurnal sensitivity and latitudinal variability of the F2 peak between the two techniques are carefully studied at these locations. Good agreement is observed between OE-retrieved NmF2 and Digisonde-measured NmF2. However, significant differences appear between OE-retrieved hmF2 and Digisonde-measured hmF2. During the daytime, Digisonde-measured hmF2 remains ∼25–45 km below the OE-retrieved hmF2, especially at mid and high latitudes. We also incorporate F-region N 𝑒 measurements from two incoherent scatter radar observations at high latitudes, located in the North American (Millstone Hill) and European (EISCAT at Tromso) sectors. The radar measurements show good agreement with OE-retrieved values. Although there are several possible sources of error in the ionogram-derived N 𝑒 profiles, our further analysis on F1 and F2 layers indicates that the low Digisonde hmF2 is caused by the autoscaled method, which tends to detect a height systematically below the F2 peak when the F1 layer is present.

GNSS radio occultation↗

Precision capacitor has improved temperature and operational stability

Vacuum dielectric capacitor is fabricated from materials with very low temperature coefficients of expansion. This precision capacitor in the 1000-2000 picofarad range has a near-zero temperature coefficient of capacitance, eliminates ion chamber action caused by air ionization in the dielectric, and minimizes electromagnetic field charging effects.

Brookshier, W. K.↗

Measurement of double-differential charged-current Drell-Yan cross-sections at high transverse masses in $pp$ collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

This paper presents a first measurement of the cross-section for the charged-current Drell-Yan process pp → W ± → ℓ ± ν above the resonance region, where ℓ is an electron or muon. The measurement is performed for transverse masses, $m$$^{W}_{T}$, between 200 GeV and 5000 GeV, using a sample of 140 fb −1 of pp collision data at a centre-of-mass energy of = 13 TeV collected by the ATLAS detector at the LHC during 2015–2018. The data are presented single differentially in transverse mass and double differentially in transverse mass and absolute lepton pseudorapidity. A test of lepton flavour universality shows no significant deviations from the Standard Model. The electron and muon channel measurements are combined to achieve a total experimental precision of 3% at low $m$$^{W}_{T}$. The single- and double differential W-boson charge asymmetries are evaluated from the measurements. A comparison to next-to-next-to-leading-order perturbative QCD predictions using several recent parton distribution functions and including next-to-leading-order electroweak effects indicates the potential of the data to constrain parton distribution functions. The data are also used to constrain four fermion operators in the Standard Model Effective Field Theory formalism, in particular the lepton-quark operator Wilson coefficient $c$$^{(c)}_{ℓq}$.

Hadron-Hadron Scattering↗

Improved cosmological constraints on the neutrino mass and lifetime

We present cosmological constraints on the sum of neutrino masses as a function of the neutrino lifetime, in a framework in which neutrinos decay into dark radiation after becoming non-relativistic. We find that in this regime the cosmic microwave background (CMB), baryonic acoustic oscillations (BAO) and (uncalibrated) luminosity distance to supernovae from the Pantheon catalog constrain the sum of neutrino masses Σm$_{ν}$ to obey Σm$_{ν}$< 0.42 eV at (95% C.L.). While the bound has improved significantly as compared to the limits on the same scenario from Planck 2015, it still represents a significant relaxation of the constraints as compared to the stable neutrino case. We show that most of the improvement can be traced to the more precise measurements of low-ℓ polarization data in Planck 2018, which leads to tighter constraints on τ$_{reio}$ (and thereby on A$_{s}$), breaking the degeneracy arising from the effect of (large) neutrino masses on the amplitude of the CMB power spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kaon–proton strong interaction at low relative momentum via femtoscopy in Pb–Pb collisions at the LHC

In quantum scattering processes between two particles, aspects characterizing the strong and Coulomb forces can be observed in kinematic distributions of the particle pairs. The sensitivity to the interaction potential reaches a maximum at low relative momentum and vanishing distance between the two particles. Ultrarelativistic heavy-ion collisions at the LHC provide an abundant source of many hadron species and can be employed as a measurement method of scattering parameters that is complementary to scattering experiments. This study confirms that momentum correlations of particles produced in Pb–Pb collisions at the LHC provide an accurate measurement of kaon–proton scattering parameters at low relative momentum, allowing precise access to the K – p $\rightarrow$ K – p process. This work also validates the femtoscopic measurement in ultrarelativistic heavy-ion collisions as an alternative to scattering experiments and a complementary tool to the study of exotic atoms with comparable precision. In this work, the first femtoscopic measurement of momentum correlations of K – p (K + $\bar{p}$) and K + p (K – $\bar{p}$) pairs in Pb–Pb collisions at centre-of-mass energy per nucleon pair of $\sqrt{s_{NN}}$ =5.02 TeV registered by the ALICE experiment is reported. The components of the K – p complex scattering length are extracted and found to be $\mathfrak{R}$f 0 = -0.91±0.03(stat)$^{+0.17}_{-0.03}$(syst) and $\mathfrak{T}$f 0 =0.92±0.05(stat)$^{+0.12}_{-0.33}$(syst). The results are compared with chiral effective field theory predictions as well as with existing data from dedicated scattering and exotic kaonic atom experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using magnetic dynamics to measure the spin gap in a candidate Kitaev material

Spin-orbit entangled materials have attracted widespread interest due to the novel magnetic phenomena arising from the interplay between spin-orbit coupling and electronic correlations. However, the intricate nature of spin interactions within Kiteav materials complicates the precise measurement of low-energy spin excitations. Using Na 2 Co 2 TeO 6 as an example, we study these low-energy spin excitations using the time-resolved resonant elastic x-ray scattering (tr-REXS). Our observations unveil remarkably slow spin dynamics at the magnetic peak, whose recovery timescale is several nanoseconds. This timescale aligns with the extrapolated spin gap of ~1 μeV, obtained by density matrix renormalization group (DMRG) simulations in the thermodynamic limit. The consistency demonstrates the efficacy of tr-REXS in discerning low-energy spin gaps inaccessible to conventional spectroscopic techniques.

36 MATERIALS SCIENCE↗

Unconventional aliphatic fluorophores discovered as the luminescence origin in citric acid–urea carbon dots

Carbon dots (CDs) are emerging as the material of choice in a range of applications due to their excellent photoluminescence properties, ease of preparation from inexpensive precursors, and low toxicity. However, the precise nature of the mechanism for the fluorescence is still under debate, and several molecular fluorophores have been reported. In this work, a new blue fluorophore, 5-oxopyrrolidine-3-carboxylic acid, was discovered in carbon dots synthesized from the most commonly used precursors: citric acid and urea. The molecular product alone has demonstrated interesting aggregation-enhanced emission (AEE), making it unique compared to other fluorophores known to be generated in CDs. We propose that this molecular fluorophore is associated with a polymer backbone within the CDs, and its fluorescence behavior is largely dependent on intermolecular interactions with the polymers or other fluorophores. As a result, a new class of non-traditional fluorophores is now relevant to the consideration of the CD fluorescence mechanism, providing both an additional challenge to the community in resolving the mechanism and an opportunity for a greater range of CD design schemes and applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stellar loci IV. red giant stars

In the fourth paper of this series, we present the metallicity-dependent Sloan Digital Sky Survey (SDSS) stellar color loci of red giant stars, using a spectroscopic sample of red giants in the SDSS Stripe 82 region. The stars span a range of 0.55 – 1.2 mag in color g – i, –0.3 – –2.5 in metallicity [Fe/H], and have values of surface gravity log g smaller than 3.5 dex. As in the case of main-sequence (MS) stars, the intrinsic widths of loci of red giants are also found to be quite narrow, a few mmag at maximum. There are however systematic differences between the metallicity-dependent stellar loci of red giants and MS stars. The colors of red giants are less sensitive to metallicity than those of MS stars. With good photometry, photometric metallicities of red giants can be reliably determined by fitting the u – g, g – r, r – i, and i – z colors simultaneously to an accuracy of 0.2 – 0.25 dex, comparable to the precision achievable with low-resolution spectroscopy for a signal-to-noise ratio of 10. By comparing fitting results to the stellar loci of red giants and MS stars, we propose a new technique to discriminate between red giants and MS stars based on the SDSS photometry. The technique achieves completeness of ~70 per cent and efficiency of ~80 per cent in selecting metal-poor red giant stars of [Fe/H] ≤ –1.2. It thus provides an important tool to probe the structure and assemblage history of the Galactic halo using red giant stars.

79 ASTRONOMY AND ASTROPHYSICS↗

The JLab Eta Factory (JEF) experiment

The new experiment, JLab Eta Factory (JEF), in the experimental Hall D at Jefferson Lab will extend the physics potential of the GlueX detector beyond the main spectroscopy program and perform precision measurements of various ?(?)decays with emphasis on rare neutral modes. The physics program of the experiment spans from precision tests of low-energy QCD to search of gauge bosons in the mass range below 1 GeV coupling the SM sector to the dark sector. Photoproduction of highly boosted ?(?)mesons using a tagged photon beam, good detection of recoil proton and multi-photon final states will allow to suppress background and collect high-statistics data sample of ?mesons. All these provide many advantages over other ?(?)experiments. The JEF experiment requires to upgrade the inner part of the forward lead glass calorimeter of the GlueX detector with high-granularity, high-resolution lead tungstate PbWO4 scintillating crystals. The calorimeter insert is currently under construction at Jeffeson Lab. The detector will be ready to take data in 2024. An overview of the JEF project will be presented.

Somov, Alexander↗

Developing a Cyclotron Radiation Emission Spectroscopy Detection System

Cyclotron Radiation Emission Spectroscopy is a new technique for ultra-precise spectroscopy of low-energy electrons. This project aimed at developing capabilities that would be useful to a future CRES experiment. The recent results from the Project 8 and He6-CRES collaborations indicate that CRES has a promising future, but will need advancements to continue developing. In this report we cover the four tasks that comprised the project: data acquisition, data management, updating the raw-data format, a cloud computing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROVABGS: The Probabilistic Stellar Mass Function of the BGS One-percent Survey

We present the probabilistic stellar mass function (pSMF) of galaxies in the DESI Bright Galaxy Survey (BGS), observed during the One-percent Survey. The One-percent Survey was one of DESI's survey validation programs conducted from 2021 April to May, before the start of the main survey. It used the same target selection and similar observing strategy as the main survey and successfully observed the spectra and redshifts of 143,017 galaxies in the r < 19.5 magnitude-limited BGS Bright sample and 95,499 galaxies in the fainter surface-brightness- and color-selected BGS Faint sample over z < 0.6. We derive pSMFs from posteriors of stellar mass, M*, inferred from DESI photometry and spectroscopy using the Hahn et al. PRObabilistic Value-Added BGS (PROVABGS) Bayesian spectral energy distribution modeling framework. We use a hierarchical population inference framework that statistically and rigorously propagates the M* uncertainties. Furthermore, we include correction weights that account for the selection effects and incompleteness of the BGS observations. We present the redshift evolution of the pSMF in BGS, as well as the pSMFs of star-forming and quiescent galaxies classified using average specific star formation rates from PROVABGS. Overall, the pSMFs show good agreement with previous stellar mass function measurements in the literature. Our pSMFs showcase the potential and statistical power of BGS, which in its main survey will observe >100 × more galaxies. Moreover, we present the statistical framework for subsequent population statistics measurements using BGS, which will characterize the global galaxy population and scaling relations at low redshifts with unprecedented precision.

79 ASTRONOMY AND ASTROPHYSICS↗

A closely regulated TWT converter.

The design concept for the TWT amplifier converter for possible use in the Thermoelectric Outer Planet Spacecraft (TOPS) is presented. An unusual combination of semiconductors and magnetics was utilized to achieve very stable voltage regulation on a number of separate outputs to satisfy the requirements of a high-power TWT, and at the same time operate at an efficiency of better than 90% from a 30-V source. The circuitry consists of an output filter, an auxiliary Jensen oscillator driving a high-reactance transformer to provide current limiting to the heater, a variable time delay, a main Jensen oscillator driving the power transformer with a maximum step-up ratio of 120 to 1, and series transistorized post regulators to provide precise voltage adjustment and low output impedance. This paper discusses the design of the high-reactance transformer and the high step-up ratio transformer, as well as the high-voltage series regulators that are limited in range and operate at the top of the unregulated output voltage. Test data are presented, and details of current transients caused by charging the filter circuits, input current ripple, and output voltage ripples are considered.

Hopper, D. J.↗

Aerodynamic mission concepts for the Mars sample return mission

Future plans for the continued exploration of Mars call for a sample return mission. This plan proposes bringing a distributed, selected sample of Mars material from several locales on Mars back to earth. The mission options studied to date utilize an extensive number of aerodynamic concepts not previously planned in past planetary exploration programs. These include various modes of orbit modification using atmospheric braking, aeromaneuvering to effect precision surface landing, very low ballistic entry for a network of surface penetrators, low flying hydrazine powered airplanes, balloons, ascent vehicles and direct entry of the samples on return to earth. This paper will discuss the concepts and their feasibility along with technology problems associated with them as surveyed from the reference material. The paper focuses primarily on the aerocapture technique as it relates to Mars orbit modification. Remaining orbit modification techniques are also discussed briefly for comparison.

Cruz, M. I.↗

Efficient Distribution of Frequency-Standard Signals

Low power system distributes precise frequency standard signal to network of remote stations. Reference frequency at phase angle modulates transmitter at master transmitter/receiver circuit and recovers at remote circuit. Two circuits continuously transmit on microwave or optical signals 100 MHz apart to effect synchronization of reference frequency and phase.

Meyer, R. F.↗

An investigation of side-stick-controller/stability and control-augmentation system requirements for helicopter terrain flight under reduced visibility conditions

Simulation of the reduced visibility tasks is effected by providing the pilot with a visually coupled, helmet-mounted display of flight-control symbols superimposed upon terrain-board imagery. Forward-flight, low-speed, and precision-hover control modes are implemented, and a method is developed for the blending of control laws between each control mode. An investigation is made of the variations in the level of integration of primary control functions on a single side-stick controller. For most of the flight tasks investigated, separated controller configurations are preferred to a single, fully integrated side-stick device. Satisfactory handling qualities over all controller configurations are attained only for a precision-hover task conducted with a high level of stability and control augmentation. For most tasks flown with the helmet-mounted display significant degradation in handling qualities occurs relative to the identical tasks flown under visual flight conditions.

Landis, K. H.↗