Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low threshold detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

CMS HGCAL ECON-D ASIC : Impact of CMOS fabrication process tuning on performance and radiation tolerance

The CMS experiment’s High Granularity Calorimeter (HGCAL) upgrade will replace CMS’s existing endcap calorimeters in preparation for the High Luminosity LHC. To effectively use over 6 million channels of this “imaging”calorimeter, CMS has developed two novel Endcap Concentrator (ECON) ASICs to perform data compression/selection on detector. The ECON-D ASIC operates on the 750kHz data path, and the ECON-T ASIC on the 40MHz trigger path. These 65 nm CMOS ASICs are radiation tolerant to 200 Mrad and low power, operating at less than 2.5 mW/channel. The first full-functionality prototype ECONs were produced and characterized in 2021-23, and an initial engineering run was performed in 2024. ECON-D radiation testing for the engineering run revealed that the chip’s internal SRAMs produce intermittent read errors for a non-negligible fraction of chips. Further investigation indicated that the SRAM performance is highly sensitive to the exact parameters of the CMOS fabrication process. To both study this process sensitivity and mitigate SRAM performance issues, twenty ECON wafers were produced in 2025 with a range of doping concentrations designed to tune the underlying transistor threshold voltage by 0%, 5%, 10%, and 15% from nominal. This talk will present first measurements of ECON-D performance, power consumption, and radiation tolerance for these four variations of CMOS process.

Syal, Chinar [Fermilab]↗

Solar Neutrino Detection with a Pixelated Liquid-Argon Time Projection Chamber

This thesis presents a study of low-energy solar neutrino detection using large-scale LArTPCs, focussing on novel pixelated readout technologies. Solar neutrinos offer a unique probe of fundamental neutrino properties and solar physics, but their detection in the MeV range is challenged by backgrounds. We investigate two complementary technologies: SoLAr, which integrates LArPix-based pixelated charge collection with Silicon Photomultipliers (SiPMs) in a hybrid anode design for simultaneous charge and light detection; and Q-Pix, a triggerless pixelated readout architecture based on charge integrate-reset circuits with local clocks, where Reset Time Differences encode ionisation waveforms via time-to-charge conversion. Two SoLAr prototypes were developed and operated, demonstrating VUV-sensitive SiPM performance in liquid argon and accurate charge-light signal matching with a charge detection threshold of $\sim 100 \mathrm{keV}$. We also implement a complete simulation and reconstruction framework, incorporating realistic detector geometry, electron transport, readout response, and detailed signal and background models, including intrinsic argon and radon progeny, as well as site-specific $\gamma$-ray and neutron fluxes. For Q-Pix, we demonstrate that with a pixel size of $4\times 4$ mm$^2$ and a reset threshold of 1 fC ($\sim 0.1475$ MeV), full-scale operation produces data volumes below 1 PB per 10 ktonne-year. For SoLAr, assuming a shielded DUNE-like detector and 100 ktonne-year exposure, we project uncertainties of $0.90\times 10^{-5}$ eV$^2$ on $\Delta m^2_{21}$ and 0.033 on $\sin^2\theta_{12}$, improving to $0.46\times 10^{-5}$ eV$^2$ and 0.025 with 400 kilotonne-year. At this higher exposure, we also obtain a day–night flux asymmetry at the level of $( -5.6 \pm 3.6 ) \%$. Combining Monte Carlo modelling, hardware validation, and advanced reconstruction techniques, this work establishes a path toward next-generation ktonne-scale LArTPCs as observatories for precision solar neutrino physics.

Ruiz Ferreira, Guilherme [Manchester U.] (ORCID:00↗

A Gamma-Ray Burst Trigger Toolkit

The detection rate of a gamma-ray burst detector can be increased by using a count rate trigger with many accumulation times DELTAt and energy bands DELTAE Because a burst's peak flux varies when averaged over different DELTAt and DELTAE the nominal sensitivity (the numerical value of the peak flux) of a trigger system is less important than how much fainter a burst could be at the detection threshold as DELTAt and DELTAE are changed. The relative sensitivity of different triggers can be quantified by referencing the detection threshold back to the peak flux for a fiducial value of DELTAt and DELTA E. This mapping between peak flux values for different sets of DELTAt and DELTAE varies from burst to burst. Quantitative estimates of the burst detection rate for a given detector and trigger system can be based on the observed rate at a measured peak flux value in this fiducial trigger. Predictions of a proposed trigger's burst detection rate depend on the assumed burst population, and these predictions can be wildly in error for triggers that differ significantly from previous missions. I base the fiducial rate on the BATSE observations: 550 bursts per sky above a peak flux of 0.3 ph per square centimeter per second averaged over DELTAt=1.024 sec and DELTAE=50-300 keV. Using a sample of 100 burst lightcurves I find that triggering on any value of DELTAt that is a multiple of 0.064 sec decreases the average threshold peak flux on the 1.024 sec timescale by a factor of 0.6. Extending DELTAE to lower energies includes the large flux of the X-ray background, increasing the background count rate. Consequently a low energy DELTAE is advantageous only for very soft bursts. Whether a large fraction of the population of bright bursts is soft is disputed; the new population of X-ray Flashes is soft but relatively faint.

Band, David L.↗

Single electron–hole pair sensitive silicon detector with surface event discrimination

Here, we demonstrate single electron-hole pair resolution in a single-sided, contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a baseline energy resolution of 3 eV. This crystal can be operated at voltages in excess of $\pm50$ V, resulting in a measured charge resolution of 0.06 electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device allows for the discrimination of surface events and separation of events occurring near the center of the detector from those near the edge. We use this discrimination ability to show that dark events seen in previous detectors of a similar design are likely dominated by charge leakage along the side wall of the device. We saw only a small reduction in dark event rate with this biasing scheme, further suggesting that sidewall and edge-dominated processes are responsible for the majority of these events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Searches for CE ν NS and physics beyond the standard model using Skipper-CCDs at CONNIE

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering ( CE ν NS ) of reactor antineutrinos off silicon nuclei using thick fully depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with subelectron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipper-CCDs for reactor neutrino detection. We report on the performance of the Skipper-CCDs, the new data processing, data quality, and event selection for CE ν NS interactions, which enable CONNIE to reach a record low detection threshold of 15 eV. The data were collected over 300 days in 2021–2022 and correspond to exposures of 14.9 g-days with the reactor-on and 3.5 g-days with the reactor-off. The difference between the reactor-on and off event rates shows no excess and yields upper limits for the neutrino interaction rates, comparable with previous CONNIE limits from standard CCDs and higher exposures. Searches for new neutrino interactions beyond the Standard Model improve the previous CONNIE limit on a simplified model with light vector mediators. A first dark matter (DM) search by diurnal modulation by CONNIE obtains the best limits on the DM-electron scattering cross section by a surface-level experiment. These promising results, obtained using a very small-mass sensor, illustrate the potential of Skipper-CCDs to probe rare neutrino interactions and motivate the plans to increase the detector mass in the near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation characteristics of the EJ-299-02H scintillator

Here a study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer to be 630 ± 110 nm. The relative light outputs from the decay of 241 Am and Compton scattering of electrons were used to extract Birks’ law coefficient, yielding a kB value of 0.087 ± 0.003 mm/MeV, consistent with some previous reports for other polystyrene-based scintillators. The results from these measurements are incorporated into the simulation to show that an energy threshold of (∼9 keV) can be achieved for the UCNProBe experiment. This low threshold enables high beta particle detection efficiency and the indirect measurement of UCN. The ability to make the scintillator deuterated, accompanied by its relatively thin dead layer, gives rise to unique applications in a wide range of UCN experiments, where it can be used to trap UCN and detect charged particles in situ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fusion of 12 C+ 24 Mg far below the barrier: Evidence for the hindrance effect

Background: The phenomenon of fusion hindrance may have important consequences on the nuclear processes occurring in astrophysical scenarios, if it is a general behavior of heavy-ion fusion at extreme subbarrier energies, including reactions involving lighter systems, e.g., reactions in the carbon and oxygen burning stages of heavy stars. The hindrance is generally identified by the observation of a maximum of the S-factor vs energy. Whether there is an S-factor maximum at very low energies for systems with a positive fusion Q value is an experimentally challenging question. Purpose: Our aim has been to search for evidence of fusion hindrance in 12 C+ 24 Mg which is a medium-light m system with positive Q value for fusion, besides the heavier cases where hindrance is recognized to be a general phenomenon. 12 C+ 24 Mg is very close to the 16 O + 16 O and 12 C + 12 C systems that are important for the late evolution of heavy stars. Methods: The experiment has been performed in inverse kinematics using the 24 Mg beam from the XTU Tandem accelerator of LNL in the energy range 26-52 MeV with an intensity of 4-8 pnA. The targets were 12 C evaporations 50 mu g/cm 2 thick, isotopically enriched to 99.9%. The fusion-evaporation residues were detected at small angles by a E-Delta E-ToF detector telescope following an electrostatic beam deflector. Results: Previous measurements of fusion cross section for 12 C+ 24 Mg were limited to above-barrier energies. In the present experiment the excitation function has been extended down to similar or equal to 15 mu b and it appears that the S factor develops a clear maximum vs energy, indicating the presence of hindrance. This is the first convincing evidence of an S factor maximum in a medium-light system with a positive fusion Q value. These results have been fitted following a recently suggested method and a detailed analysis within the coupled-channels model that has been performed using a Woods-Saxon potential and including the ground state rotational band of 24 Mg. The coupled-channels calculations give a good account of the data near and above the barrier but overpredict the cross sections at very low energies. Conclusions: The hindrance phenomenon is clearly observed in 12 C+ 24 Mg, and its energy threshold is in reasonable agreement with the systematics observed for several medium-light systems. The fusion cross sections at the hindrance threshold show that the highest value (sigma(s) = 1.6 mb) is indeed found for this system. Therefore it may even be possible to extend the measurements further down in energy to better establish the position of the S-factor maximum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prototype Test Results for the Single Photon Detection SLR2000 Satellite Laser Ranging System

NASA's aging Satellite Laser Ranging (SLR) network is scheduled to be replaced over the next few years with a fully automated single photon detection system. A prototype of this new system, called SLR2000, is currently undergoing field trials at the Goddard Space Flight Center in Greenbelt, Maryland to evaluate photon counting techniques and determine system hardware, software, and control algorithm performance levels and limitations. Newly developed diode pumped microchip lasers and quadrant microchannel plate-based photomultiplier tubes have enabled the development of this high repetition rate single photon detection SLR system. The SLR2000 receiver threshold is set at the single photoelectron (pe) level but tracks satellites with an average signal level typically much less than 1 pe. The 2 kHz laser fire rate aids in satellite acquisition and tracking and will enable closed loop tracking by accumulating single photon count statistics in a quadrant detector and using this information to correct for pointing errors. Laser transmitter beamwidths of 10 arcseconds (FWHM) or less are currently being used to maintain an adequate signal level for tracking while the receiver field of view (FOV) has been opened to 40 arcseconds to accommodate point ahead/look behind angular offsets. In the near future, the laser transmitter point ahead will be controlled by a pair of Risley prisms. This will allow the telescope to point behind and enable closure of the receiver FOV to roughly match the transmitter beam divergence. Bandpass filters (BPF) are removed for night tracking operations while 0.2 nm or 1 nm filters are used during daylight operation. Both day and night laser tracking of Low Earth Orbit (LEO) satellites has been achieved with a laser transmitter energy of only 65 microjoules per pulse. Satellite tracking is presently limited to LEO satellites until the brassboard laser transmitter can be upgraded or replaced. Simultaneous tracks have also been observed with NASA s SLR standard, MOBLAS 7, for the purposes of data comparison and identification of biases. Work continues to optimize the receive optics; upgrade or replace the laser transmitter; calibrate the quadrant detector, the point ahead Risley prisms, and event timer verniers; and test normal point generation with SLR2000 data. This paper will report on the satellite tracking results to date, issues yet to be resolved, and future plans for the SLR2000 system.

Zagwodzki, Thomas W.↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗

Dark Matter Induced Power in Quantum Devices

We point out that power measurements of single quasiparticle devices open a new avenue to detect dark matter (DM). The threshold of these devices is set by the Cooper pair binding energy, and is therefore so low that they can detect DM as light as about an MeV incoming from the Galactic halo, as well as the low-velocity thermalized DM component potentially present in the Earth. Using existing power measurements with these new devices, as well as power measurements with SuperCDMS-CPD, we set new constraints on the spin-independent DM scattering cross section for DM masses from about 10 MeV to 10 GeV. We outline future directions to improve sensitivity to both halo DM and a thermalized DM population in the Earth using power deposition in quantum devices. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correction for nonlinear photon counting effects in lidar systems

Photomultiplier tubes (PMT's) employed in the photon counting (PC) mode of operation are widely used as detectors in lidar systems. In our laboratory, we have developed a versatile Nd:YAG lidar which is used for measurement of both the middle atmosphere and the troposphere. With this system, we encounter a very wide range of signal levels ranging from the extremely weak signals from the top of the mesosphere to the very strong returns from low level clouds. Although the system is capable of operating the PMT's in either the analog detection or photon counting mode, we find that often when we use photon counting we have portions of our lidar return which contain very useful information but are not within the linear operating regime of the PC system. We report the results of our efforts to explore the extent to which such high intensity PC signals can be quantitatively analyzed. In particular, a useful model relating the mean 'true' count rate and the observed count rate is presented and it's application to our system demonstrated. This model takes into account the variation in height of the PMT output pulses and the effect of the pulse height discrimination threshold.

Donovan, D. P.↗

Non-Markovian Hole Excess Noise in Avalanche Amorphous Selenium Thin Films

Enhancing the signal-to-noise ratio in avalanche photodiodes by utilizing impact ionization gain requires materials exhibiting low excess noise factors. Amorphous selenium (a-Se) as a wide bandgap at ~2.1 eV, a solid-state avalanche layer, demonstrates single-carrier hole impact ionization gain and manifests ultralow thermal generation rates. A comprehensive study of the history dependent and non-Markovian nature of hot hole transport in a-Se was modeled using a Monte Carlo (MC) random walk of single hole free flights, interrupted by instantaneous phonon, disorder, hole–dipole, and impact-ionization scattering interactions. The hole excess noise factors were simulated for 0.1–15 μm a-Se thin-films as a function of mean avalanche gain. The hole excess noise factors in a-Se decreases with an increase in electric field, impact ionization gain, and device thickness. The history dependent nature of branching of holes is explained using a Gaussian avalanche threshold distance distribution and the dead space distance, which increases determinism in the stochastic impact ionization process. An ultralow non-Markovian excess noise factor of ~1 was simulated for 100 nm a-Se thin films corresponding to avalanche gains of 1000. Future detector designs can utilize the nonlocal/non-Markovian nature of the hole avalanche in a-Se, to enable a true solid-state photomultiplier with noiseless gain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decreasing Proton Single Event Effects in CubeSats with Shielding

Shields-1, NORAD ID 43850,has been operating in polar low earth orbit since December 2018. The shielding has resulted in a lower total ionizing dose over time than typical aluminum thin-walled CubeSat structures. The reduced ionizing dosage caused by Shields-1 increases the reliability of commercial parts and reduces internal charging. Furthermore, the Shields-1 shielding reduces the ionizing particle fluence inside the spacecraft that contributes to the ionizing dose. NOVICE Sigma shielding software, using the (Aerospace Proton) AP8 –(Aerospace Electron) AE8 solar minimum trapped belt environment for a 1-year mission, estimates a 21.3 g/cm2 aluminum effective shielding for the Shields-1 electronics enclosure. This high areal density reduces not only the total number of energetic protons, but also reduces the number of ionizing particles over all modeled energies from the estimated shielded fluence for a 1-year mission. NOVICE Adjoint CAD modeling of the Shields-1 structure, with the detector located within the electronics enclosure, estimates that the total number of particles is reduced from 2.20x 10exp9 protons/cm2 to 1.52x 10exp8 protons/cm2, which represents 6.90% of the remaining particles(figure 1). By slowing down approximations of the integral proton fluence, a minimum proton threshold is estimated at 151 MeV. In comparison, a 0.204-cm aluminum thin-walled 3-unit (U) structure, with a 0.907 g/cm2 effective shielding, has 25.0% remaining particles and a minimum proton threshold of 36.2 MeV(figure 1). Proton energies that contribute to single event effects in radiation tolerant or higher semiconductor hardness are typically 100 MeV and higher. The Shields-1 electronics enclosure is estimated to attenuate energies: 100 MeV by 76.5%, 200 MeV by 61.7%, and 500 MeV by 63.0%(figure 2), when comparing the space environment proton differential fluence with the shielded differential fluence. The aluminum thin-walled structure is estimated to attenuate proton energies: 100 MeV by 13.7%, 200 MeV by 12.4%, and 500 MeV by 12.6%(figure 2), which are lower than for the Shields-1 electronics enclosure. The significant differences in attenuation between the Shields-1 electronics enclosure and aluminum thin-walled 3U structure show the additional utility of increasing shielding effectiveness for reducing the numbers of energetic protons that contribute to single event effects.

Larry Thomsen↗

Physics-Based Machine Learning Methods for U-235 Forensics Signatures

Signatures of low-intensity U-235 sources have been recently studied by utilizing a variety of machine learning (ML) classifiers using features derived from gamma spectral measurements collectedunder structured campaigns. Several ML classifiers, such as ensemble of tress and classification trees, revealed misleadingly-optimistic training error due to over-fitting, and furthermore,their performance is not directly relatable to the physical properties due to their data-driven, opaque designs. We present a regression-based ML method that first estimates the inverse distanceto the source and then utilizes a threshold to infer its presence, by representing the background as a source located at an infinite distance. For the inverse distance estimation, we study the ensembleof trees and Gaussian process regression methods, and a hyper parameter auto-tuning and selection method that employs five regression estimators. These methods avoid the over-fittingobserved in several ML classifiers, while providing the classification error nearly comparable to them based on independent test data. Their error is directly related to estimates of the inversephysical distance to source, and the precision of error determines the seperability property that determines the false alarm and missed detection rates. The property of monotonic decrease of thesource strength with increasing detector distance combined with Poisson distribution of measurements is utilized to analytically validate these methods by deriving the generalization equations ofunderlying regression methods.

Rao, Nageswara↗