Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Note: Readout of a micromechanical magnetometer for the ITER fusion reactor

We present readout instrumentation for a MEMS magnetometer, placed 30 m away from the MEMS element. This is particularly useful when sensing is performed in high-radiation environment, where the semiconductors in the readout cannot survive. High bandwidth transimpedance amplifiers are used to cancel the cable capacitances of several nanofarads. A frequency doubling readout scheme is used for crosstalk elimination. Signal-to-noise ratio in the range of 60 dB was achieved and with sub-percent nonlinearity. The presented instrument is intended for the steady-state magnetic field measurements in the ITER fusion reactor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-time variation in magnetic structure of CeIr 3 Si 2 : Observation of a nucleation-and-growth process of magnetic domains

CeIr 3 Si 2 is the first three-dimensional uniform magnet in which the long-time variation in magnetic structure was observed. To clarify the microscopic mechanism of this magnetic structural change, time-resolved neutron scattering measurements have been reinvestigated. Clear time variations in the line widths as well as the amplitudes of magnetic Bragg diffractions have been observed in this improved instrumentation. On the notion of this observation, a nucleation-and-growth model of magnetic structural change has been presented. The numerical calculation with this model reproduces well the observation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Second Target Station Project (CHESS Technical Report)

CHESS is a direct geometry neutron spectrometer designed to detect and analyze weak signals intrinsic to small cross-sections (e.g., small mass, small magnetic moments or neutron absorbing materials). This instrument is optimized to enable unprecedented characterization of quantum materials, spin liquids, thermoelectric and battery materials, liquids, and soft matter. The ability to simultaneously measure dynamic processes over a wide energy range for very small samples will make CHESS the spectrometer of choice for the initial exploration of new materials. The broad dynamic range will also be well matched to measurements of relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of STS enables use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single experiment. An essential feature of CHESS is the capability for polarization analysis to separate nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials, and better understanding spin-anisotropic correlations. This instrument will employ advanced sample environments such as high-pressure cells, dilution refrigerators, high field cryo-magnets and polarization devices, as well as combinations of these, to solve problems at the forefront of materials research. CHESS will be one of the flagship spectrometers of the Second Target Station (STS), providing world leading capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrically detected magnetic resonance in a W-band microwave cavity

We describe a low-temperature sample probe for the electrical detection of magnetic resonance in a resonant W-band (94 GHz) microwave cavity. The advantages of this approach are demonstrated by experiments on silicon field-effect transistors. A comparison with conventional low-frequency measurements at X-band (9.7 GHz) on the same devices reveals an up to 100-fold enhancement of the signal intensity. In addition, resonance lines that are unresolved at X-band are clearly separated in the W-band measurements. Electrically detected magnetic resonance at high magnetic fields and high microwave frequencies is therefore a very sensitive technique for studying electron spins with an enhanced spectral resolution and sensitivity.

47 OTHER INSTRUMENTATION↗

Measurement of transmission efficiency for 400 MeV proton beam through collimator at Fermilab MuCool Test Area using Chromox-6 scintillation screen

The MuCool Test Area (MTA) at Fermilab is a facility to develop the technology required for ionization cooling for a future Muon Collider and/or Neutrino Factory. As part of this research program, feasibility studies of various types of RF cavities in a high magnetic field environment are in progress. As a unique approach, we have tested a RF cavity filled with a high pressure hydrogen gas with a 400 MeV proton beam in an external magnetic field (B = 3 T). Quantitative information about the number of protons passing through this cavity is an essential requirement of the beam test. The MTA is a flammable gas (hydrogen) hazard zone. Due to safety reasons, no active (energized) beam diagnostic instrument can be used. Moreover, when the magnetic field is on, current transformers (toroids) used for beam intensity measurements do not work due to the saturation of the ferrite material of the transformer. Based on these requirements, we have developed a passive beam diagnostic instrumentation using a combination of a Chromox-6 scintillation screen and CCD camera. This paper describes details of the beam profile and position obtained from the CCD image with B = 0 T and B = 3 T, and for high and low intensity proton beams. A comparison is made with beam size obtained from multi-wires detector. Beam transmission efficiency through a collimator with a 4 mm diameter hole is measured by the toroids and CCD image of the scintillation screen. Results show that the transmission efficiency estimated from the CCD image is consistent with the toroid measurement, which enables us to monitor the beam transmission efficiency even in a high magnetic field environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A HEMISPHERIC HELICITY SIGN RULE INDICATED BY LARGE-SCALE PHOTOSPHERIC MAGNETIC FIELDS AT THREE PHASES OF SOLAR CYCLE 23

The hemispheric sign rule of current helicity is examined for large-scale magnetic fields, extending to 60{sup 0} high in solar latitudes, at three different phases of solar cycle 23 and using three different instruments. The current helicity is calculated from the vector magnetic fields derived respectively from the longitudinal full-disk magnetograms obtained by the Michelson Doppler Imager on board the Solar and Heliospheric Observatory as well as the Kitt Peak Vacuum Telescope and the Synoptic Long-term Investigations of the Sun at the National Solar Observatory at Kitt Peak. We have used the same technique introduced by Pevtsov and Latushko to retrieve the vector magnetic field but have applied a different method to calculate the current helicity. Our analysis strengthens evidence that the large-scale magnetic fields show a clear and consistent current helicity pattern that follows the established hemispheric rule, that is, a positive helicity sign in the southern hemisphere and a negative helicity sign in the northern hemisphere. This hemispheric sign pattern is present everywhere in the global magnetic field, extending to 60{sup 0} high in solar latitudes, independent of the instruments and parameters used, and is evident at both solar maximum and minimum phases.

79 ASTRONOMY AND ASTROPHYSICS↗

High efficiency radio frequency antennas for amplifier free quantum sensing applications

Radio frequency (RF) signals are frequently used in emerging quantum applications due to their spin state manipulation capability. Efficient coupling of RF signals into a particular quantum system requires the utilization of carefully designed and fabricated antennas. Nitrogen vacancy (NV) defects in diamond are commonly utilized platforms in quantum sensing experiments with the optically detected magnetic resonance (ODMR) method, where an RF antenna is an essential element. We report on the design and fabrication of high efficiency coplanar RF antennas for quantum sensing applications. Single and double ring coplanar RF antennas were designed with -37 dB experimental return loss at 2.87 GHz, the zero-field splitting frequency of the negatively charged NV defect in diamond. The efficiency of both antennas was demonstrated in magnetic field sensing experiments with NV color centers in diamond. In conclusion, an RF amplifier was not needed, and the 0 dB output of a standard RF signal generator was adequate to run the ODMR experiments due to the high efficiency of the RF antennas.

47 OTHER INSTRUMENTATION↗

HELIOSHEATH MAGNETIC FIELDS BETWEEN 104 AND 113 AU IN A REGION OF DECLINING SPEEDS AND A STAGNATION REGION

We examine the relationships between the magnetic field and the radial velocity component V{sub R} observed in the heliosheath by instruments on Voyager 1 (V1). No increase in the magnetic field strength B was observed in a region where V{sub R} decreased linearly from 70 km s{sup -1} to 0 km s{sup -1} as plasma moved outward past V1. An unusually broad transition from positive to negative polarity was observed during a Almost-Equal-To 26 day interval when the heliospheric current sheet (HCS) moved below the latitude of V1 and the speed of V1 was comparable to the radial speed of the heliosheath flow. When V1 moved through a region where V{sub R} Almost-Equal-To 0 (the 'stagnation region'), B increased linearly with time by a factor of two, and the average of B was 0.14 nT. Nothing comparable to this was observed previously. The magnetic polarity was negative throughout the stagnation region for Almost-Equal-To 580 days until 2011 DOY 235, indicating that the HCS was below the latitude of V1. The average passage times of the magnetic holes and proton boundary layers were the same during 2009 and 2011, because the plasma moved past V1 during 2009 at the same speed that V1 moved through the stagnation region during 2011. The microscale fluctuations of B in the stagnation region during 2011 are qualitatively the same as those observed in the heliosheath during 2009. These results suggest that the stagnation region is a part of the heliosheath, rather than a 'transition region' associated with the heliopause.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct current magnetic Hall probe technique for measurement of field penetration in thin film superconductors for superconducting radio frequency resonators

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently, high purity niobium is the material of choice for SRF cavities that have been optimized to operate near their theoretical field limits. This brings about the need for significant R & D efforts to develop next generation superconducting materials that could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under a high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate a superconductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements that are strongly influenced by the film orientation and shape and edge effects. In this work, we report the development of an experimental setup to measure the field of full flux penetration through films and multi-layered superconductors. Our system combines a small superconducting solenoid that can generate a magnetic field of up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the superconductor. We report this setup can be used to study alternative materials that could potentially outperform niobium, as well as superconductor–insulator–superconductor (SIS) multilayer coatings on niobium.

47 OTHER INSTRUMENTATION↗

Gamma-ray spectroscopy at MHz counting rates with a compact LaBr{sub 3} detector and silicon photomultipliers for fusion plasma applications

Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr{sub 3} scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE MAGNETIC FIELD IN THE NGC 2024 FIR 5 DENSE CORE

We used the Submillimeter Array to observe the thermal polarized dust emission from the protostellar source NGC 2024 FIR 5. The polarized emission outlines a partial hourglass morphology for the plane-of-sky component of the core magnetic field. Our data are consistent with previous BIMA maps, and the overall magnetic field geometries obtained with both instruments are similar. We resolve the main core into two components, FIR 5A and FIR 5B. A possible explanation for the asymmetrical field lies in depolarization effects due to the lack of internal heating from the FIR 5B source, which may be in a prestellar evolutionary state. The field strength was estimated to be 2.2 mG, in agreement with previous BIMA data. We discuss the influence of a nearby H II region over the field lines at scales of {approx}0.01 pc. Although the hot component is probably compressing the molecular gas where the dust core is embedded, it is unlikely that the radiation pressure exceeds the magnetic tension. Finally, a complex outflow morphology is observed in CO (3 {yields} 2) maps. Unlike previous maps, several features associated with dust condensations other than FIR 5 are detected.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Support and Drive System of the PETRA III APPLE Undulator

Helmholtzzentrum Berlin has built an APPLE II undulator for the storage ring PETRA III. The device has a total length of 5m and a minimum gap of 11mm. The high magnetic forces in particular in the inclined mode have been analyzed by means of finite element methods (FEM). Specific mechanic components such as flexible joints have been optimized to cope with the gap- and shift-dependent 3D-forces and a sophisticated control and drive system has been implemented. After completion of the device, detailed laser interferometer measurements for all operation modes have been performed. The data are compared to the FEM simulations.

43 PARTICLE ACCELERATORS↗

Effect of moderate magnetic annealing on the microstructure, quasi-static and viscoelastic mechanical behavior of a structural epoxy

In this study the effect of moderate magnetic fields on the microstructure of a structural epoxy system was investigated. The changes in the microstructure have been quantitatively investigated using wide angle x-ray diffraction (WAXD) and pole figure analysis. The mechanical properties (modulus, hardness and strain rate sensitivity parameter) of the epoxy system annealed in the magnetic field were probed with the aid of instrumented nanoindentation and the results are compared to the reference epoxy sample. To further examine the creep response of the magnetically annealed and reference samples, short 45 min duration creep tests were carried out. An equivalent to the macro scale creep compliance was calculated using the aforementioned nano-creep data. Using the continuous complex compliance (CCC) analysis, the phase lag angle, tan (δ), between the displacement and applied force in an oscillatory nanoindentation test was measured for both neat and magnetically annealed systems through which the effect of low magnetic fields on the viscoelastic properties of the epoxy was invoked. The comparison of the creep strain rate sensitivity parameter , A/d(0), from short term(80 ), creep tests and the creep compliance J(t) from the long term(2700 s) creep tests with the tan(δ) suggests that former parameter is a more useful comparative creep parameter than the creep compliance. The results of this investigation reveal that under low magnetic fields both the quasi-static and viscoelastic mechanical properties of the epoxy have been improved.

36 MATERIALS SCIENCE↗

The Study of Single Nb3Sn Quadrupole Coils Using a Magnetic Mirror Structure

Several 90-mm quadrupole coils made of 0.7-mm Nb{sub 3}Sn strand based on the 'Restack Rod Process' (RRP) of 108/127 design, with cored and non-cored cables and different cable insulation, were fabricated and individually tested at Fermilab using a test structure designed to provide a quadrupole magnetic field environment. The coils were instrumented with voltage taps and strain gauges to study quench performance and mechanical properties. The Nb{sub 3}Sn strand and cable parameters, the coil fabrication details, the mirror model assembly procedure and test results at temperatures of 4.5 K and 1.9 K are reported and discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The inductively driven transmission line: A passively coupled device for diagnostic applications on the Z pulsed power facility

The inductively driven transmission line (IDTL) is a miniature current-carrying device that passively couples to fringe magnetic fields in the final power feed on the Z Pulsed Power Facility. The IDTL redirects a small amount of Z’s magnetic energy along a secondary path to ground, thereby enabling pulsed power diagnostics to be driven in parallel with the primary load for the first time. IDTL experiments and modeling presented here indicate that IDTLs operate non-perturbatively on Z and that they can draw in excess of 150 kA of secondary current, which is enough to drive an X-pinch backlighter. Further experiments show that IDTLs are also capable of making cleaner, higher-fidelity measurements of the current flowing in the final feed.

47 OTHER INSTRUMENTATION↗

Spin echo small-angle neutron scattering using superconducting magnetic Wollaston prisms

Here, we show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

47 OTHER INSTRUMENTATION↗

Use of Photocell Readouts in the Development of High Resolution Scintillator Systems

Photomultiplier-based scintillator spectrometers are the systems of choice for a multitude of X-ray and gamma radiation measurement applications. Despite widespread use, they have numerous shortcomings. The most serious is the relatively poor energy resolution that makes isotope identification problematic particularly in the case of trace quantities. Energy resolution in scintillator/photomultiplier tube (PMT) spectrometers is governed by a combination of the crystal intrinsic resolution that includes non-linearity effects, photomultiplier statistics, and the variability in the probability of a scintillation photon generating a photoelectron at the photocathode. It is evident that energy resolution in these systems is linked to both the physics of light generation in the scintillator, as well as the characteristics of the PMT. PMTs also present design problems especially in the case of handheld and portable instruments due to their considerable weight and volume. Additionally, PMTs require well-regulated high voltage and are vulnerable to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗