Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Site-Selective Determination of Magnetic Helices in BaTiCoFe{sub 10}O{sub 19} by Resonant Magnetic Scattering

Synchrotron radiation intensity measurements were made for single crystals of ferrimagnetic BaTiCoFe{sub 10}O{sub 19} at the BL-6C(3A) beamline of the Photon Factory. The resonant x-ray magnetic scattering (RXMS) method at the Fe K edge makes it possible to determine the magnetic crystal structure, having the magnetic helices for Fe ions in tetrahedral 4f{sub 1}, bipyramidal 2b, and octahedral 2a, 4f{sub 2} and 12k sites. Based on the information on x-ray magnetic circular dichroism (XMCD) and a resonant magnetic scattering factor f''{sub m} ( = 0.23) estimated from BaFe{sub 12}O{sub 19} at E = 7128.2 eV, the magnetic structures have been determined from an asymmetrical ratio {Delta}R (Y{sup +}-Y{sup -})/(Y{sup +}+Y{sup -}), where Y{sup +} and Y{sup -} are scattering intensities for left- and right-circular polarizations, respectively. Spin orientations were estimated in the least-squares procedure to minimize a residual factor of {Sigma}({Delta}R{sub obs}-{Delta}R{sub calc}){sup 2}. The canting angles estimated in this study are 180 deg., 19 deg., 118 deg., 180 deg. and 65 deg. for the magnetic moments of Fe ions in 4f{sub 1}, 2b, 2a, 4f{sub 2} and 12k sites, respectively.

36 MATERIALS SCIENCE↗

Divertor detachment in the pre-fusion power operation phase in ITER during application of resonant magnetic perturbations

Detachment of the divertor plasma during application of resonant magnetic perturbation (RMP) fields is evaluated for hydrogen H-mode plasma during the first pre-fusion power operation (PFPO-1) phase in ITER by 3D plasma boundary modelling with EMC3–EIRENE. Plasma response effects from a linearized, resistive, single fluid MHD model are discussed, which includes partial screening of the externally applied field—but also field amplification near the separatrix. Furthermore, this field amplification is found to play a pivotal role for the magnetic footprint on the divertor targets, but is sensitive to model parameters. Extensions of the footprint beyond the straight portions of the ITER vertical divertor targets, optimized for high stationary heat flux handling, may be possible depending on the level of toroidal rotation in the plasma. Exhaust from the bulk plasma is guided by the helical corrugations (lobes) of the perturbed separatrix, and this results in an upstream heat flux that is distributed over these lobes with lower peak values than in the typical radial heat flux profiles seen in the absence of magnetic perturbations. As a consequence, an earlier onset (with respect to the upstream density) of detachment is found in the traditional strike zone when RMPs are applied, but secondary, non-axisymmetric strike locations appear—and those remain attached at temperatures above 10 eV. Neon seeding can mitigate these non-axisymmetric heat loads, but this becomes less efficient for large magnetic footprints.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic resonance force microscopy with matching frequencies of cantilever and spin

We have studied theoretically magnetic resonance force microscopy with a high-frequency nanomechanical cantilever when the cantilever frequency matches the resonant frequency of a single electron spin. Our analysis shows that in this situation, there is a small probability that the cantilever will oscillate with a large frequency shift. In conclusion, this can open new experimental opportunities for increasing the sensitivity in the detection of a single electron spin or even a single nuclear spin by using a high-frequency cantilever.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A reactor for high-throughput high-pressure nuclear magnetic resonance spectroscopy

The design of a reactor for operando nuclear magnetic resonance (NMR) monitoring of high-pressure gas-liquid reactions is described. The Wisconsin High Pressure NMR Reactor (WiHP-NMRR) design comprises four modules: a sapphire NMR tube with titanium tube holder rated for pressures as high as 1000 psig (68 atm) and temperatures ranging from −90 to 90 °C, a gas circulation system that maintains equilibrium concentrations of dissolved gases during gas-consuming or gas-releasing reactions, a liquid injection apparatus that is capable of adding measured amounts of solutions to the reactor under high pressure conditions, and a rapid wash system that enables the reactor to be cleaned without removal from the NMR instrument. The WiHP-NMRR is compatible with commercial 10 mm NMR probes. Reactions performed in the WiHP-NMRR yield high quality, information-rich, and multinuclear NMR data over the entire reaction time course with rapid experimental turnaround.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

Optimization of 3D controlled ELM-free state with recovered global confinement for KSTAR with n = 1 resonant magnetic field perturbation

Mitigation of deleterious heat flux from edge-localized modes (ELMs) on fusion reactors is often attempted with 3D perturbations of the confining magnetic fields. However, the established technique of resonant magnetic perturbations (RMPs) also degrades plasma performance, complicating implementation on future fusion reactors. Here, we introduce an adaptive real-time control scheme on the KSTAR tokamak as a viable approach to achieve an ELM-free state and simultaneously recover high-confinement (βN ~ 1.91, β p ~ 1.53, and H 98 ~ 0.9), demonstrating successful handling of a volatile complex system through adaptive measures. We show that, by exploiting a salient hysteresis process to adaptively minimize the RMP strength, stable ELM suppression can be achieved while actively encouraging confinement recovery. This is made possible by a self-organized transport response in the plasma edge which reinforces the confinement improvement through a widening of the ion temperature pedestal and promotes control stability, in contrast to the deteriorating effect on performance observed in standard RMP experiments. These results establish the real-time approach as an up-and-coming solution toward an optimized ELM-free state, which is an important step for the operation of ITER and reactor-grade tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear magnetic resonance study of Gd-based nanoparticles to tag boron compounds in boron neutron capture therapy

We report the investigation of new organic complexes containing a magnetic moment (Gd-based molecular nanomagnets), which can serve the double purpose of acting as boron neutron capture therapy (BNCT) agents, and at the same time act as contrast agents to detect the molecule in the tissue by a proton magnetic resonance imaging (MRI). We also explore the possibility of monitoring the concentration of the BNCT agent directly via proton and boron NMR relaxation. The absorption of {sup 10}B-enriched molecules inside tumoral liver tissues has been shown by NMR measurements and confirmed by {alpha} spectroscopy. A new molecular Gd-tagged nanomagnet and BNCT agent (GdBPA) has been synthesized and characterized measuring its relaxivity R{sub 1} between 10 kHz and 66 MHz, and its use as a contrast agent in MRI has been demonstrated. The NMR-based evidence of the absorption of GdBPA into living tumoral cells is also shown.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods and systems for low to ultra-low magnetic field nuclear magnetic resonance for detecting chemical nerve agents

A nuclear magnetic resonance (NMR) system is configured to detect chemical threat material. The system comprises a magnet configured to generate a magnetic field of about 300 millitesla or less; and a probe configured to detect nuclear relaxation of at least two nuclei selected from the group consisting of 1H, 19F, 31P and 14N, and detect the spin density of nuclei selected from the group consisting of 1H, 19F, 31P and 14N, following excitation.

Williams, Robert F.↗

Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We have validated the dosimetric accuracy of a commercial MRgIMRT system using high-resolution 3D techniques. We have demonstrated for the first time that hybrid 3D remote dosimetry is a comprehensive and feasible approach to commissioning MRgIMRT. This may provide better sensitivity in error detection compared with standard 2-dimensional measurements and could be used when implementing complex new magnetic resonance guided radiation therapy technologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of the commensurate magnetic structure in the heavy-fermion compound CePt 2 In 7 using magnetic resonant x-ray diffraction

In this paper, we investigated the magnetic structure of the heavy-fermion compound CePt 2 In 7 below T N = 5.34 (2) K using magnetic resonant x-ray diffraction at ambient pressure. The magnetic order is characterized by a commensurate propagation vector k 1/2 = (1/2, 1/2, 1/2) with spins lying in the basal plane. Our measurements did not reveal the presence of an incommensurate order propagating along the high-symmetry directions in reciprocal space but cannot exclude other incommensurate modulations or weak scattering intensities. The observed commensurate order can be described equivalently by either a single-k structure or by a multi-k structure. Furthermore we explain how a commensurate-only ordering may explain the broad distribution of internal fields observed in nuclear quadrupolar resonance experiments [Sakai et al., Phys. Rev. B 83, 140408 (2011)] that was previously attributed to an incommensurate order. We also report powder x-ray diffraction showing that the crystallographic structure of CePt 2 In 7 changes monotonically with pressure up to P = 7.3 GPa at room temperature. The determined bulk modulus B 0 = 81.1 (3) GPa is similar to those of the Ce-115 family. Broad diffraction peaks confirm the presence of pronounced strain in polycrystalline samples of CePt 2 In 7 . Lastly, we discuss how strain effects can lead to different electronic and magnetic properties between polycrystalline and single crystal samples.

36 MATERIALS SCIENCE↗

Modified Method for Reconstructing the Image from Projections in Magnetic Resonance Tomography

A method for reconstructing the image from projections in magnetic resonance tomography using an excitation pulse with a linear frequency modulation has been considered. The shape of the spin echo envelope coincides with the projection of the spin density onto the direction of the axis along which the magnetic field gradient is applied. The spin echo excitation by a sinc pulse and a pulse with a linear frequency modulation has been simulated. The former pulse excites the required cross section of a 3D object, while the latter pulse has made it possible to form the spin echo envelope, which coincides in shape with the projection of the spin density of nuclei onto the direction of the gradient. The set of the projections onto different directions of the gradient has made it possible to reconstruct the 2D image of a section.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic resonance imaging as a tool for extravehicular activity analysis

The purpose of this research is to examine the value of magnetic resonance imaging (MRI) as a means of conducting kinematic studies of the hand for the purpose of EVA capability enhancement. After imaging the subject hand using a magnetic resonance scanner, the resulting 2D slices were reconstructed into a 3D model of the proximal phalanx of the left hand. Using the coordinates of several landmark positions, one is then able to decompose the motion of the rigid body. MRI offers highly accurate measurements due to its tomographic nature without the problems associated with other imaging modalities for in vivo studies.

Dickenson, R.↗

A Telomerase-Activated Magnetic Resonance Imaging Probe for Consecutively Monitoring Tumor Growth Kinetics and In Situ Screening Inhibitors

Telomerase has long been considered as a biomarker for cancer diagnosis and a therapeutic target for drug discovery. Detecting telomerase activity in vivo could provide more direct information of tumor progression and response to drug treatment, which, however, is hampered by the lack of an effective probe that can generate an output signal without a tissue penetration depth limit. Here in this study, using the principle of distance-dependent magnetic resonance tuning, we constructed a telomerase-activated magnetic resonance imaging probe (TAMP) by connecting superparamagnetic ferroferric oxide nanoparticles (SPFONs) and paramagnetic Gd-DOTA (Gd(III) 1,4,7,10- tetraazacyclododecane-1,4,7,10-tetraazacyclododecane-1,4,7,10-tet-raacetic acid) complexes via telomerase-responsive DNA motifs. Upon telomerase-catalyzed extension of the primer in TAMP, Gd-DOTA-conjugated oligonucleotides can be liberated from the surface of SPFONs through a DNA strand displacement reaction, restoring the T 1 signal of the Gd-DOTA for a direct readout of the telomerase activity. Here we show that, by tracking telomerase activity, this probe provides consistent monitoring of tumor growth kinetics during progression and in response to drug treatment and enables in situ screening of telomerase inhibitors in whole-animal models. This study provides an alternative toolkit for cancer diagnosis, treatment response assessment, and anticancer drug screening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of conductivity and permittivity on samples sealed in nuclear magnetic resonance tubes

We present a broadband impedance spectroscopy instrument designed to measure conductivity and/or permittivity for samples that are sealed in glass tubes, such as the standard 5 mm tubes used for nuclear magnetic resonance experiments. The calibrations and corrections required to extract the dielectric properties of the sample itself are outlined. It is demonstrated that good estimates of the value of dc-conductivity can be obtained even without correcting for the effects of glass or air on the overall impedance. The approach is validated by comparing data obtained from samples sealed in nuclear magnetic resonance tubes with those from standard dielectric cells, using glycerol and butylmethylimidazolium-hexafluorophosphate as respective examples of a molecular and an ionic liquid. This instrument and approach may prove useful for other studies of permittivity and conductivity where contact to the metal electrodes or to the ambient atmosphere needs to be avoided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Composite and shaped pulses for efficient and robust pumping of disconnected eigenstates in magnetic resonance

Hyperpolarization methods, which can enhance nuclear spin signals by orders of magnitude, open up important new opportunities in magnetic resonance. However, many of these applications are limited by spin lattice relaxation, which typically destroys the hyperpolarization in seconds. Significant lifetime enhancements have been found with “disconnected eigenstates” such as the singlet state between a pair of nearly equivalent spins, or the “singlet-singlet” state involving two pairs of chemically equivalent spins; the challenge is to populate these states (for example, from thermal equilibrium magnetization or hyperpolarization) and to later recall the population into observable signal. Existing methods for populating these states are limited by either excess energy dissipation or high sensitivity to inhomogeneities. Here we overcome the limitations by extending recent work using continuous-wave irradiation to include composite and adiabatic pulse excitations. Traditional composite and adiabatic pulses fail completely in this problem because the interactions driving the transitions are fundamentally different, but the new shapes we introduce can move population between accessible and disconnected eigenstates over a wide range of radio-frequency (RF) amplitudes and offsets while depositing insignificant amounts of power.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Footprint structures due to resonant magnetic perturbations in DIII-D

Numerical modeling of the typical footprint structures on the target plates of a divertor tokamak is presented. In the tokamak DIII-D [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] toroidal mode number n=3 resonant magnetic perturbations are responsible for characteristic footprint stripes. The numerics can resolve substructures within each footprint stripe, which are related to the internal magnetic topology. It is shown that the footprint structures on the inner target plate can be predicted by the unstable manifolds of the separatrix and the q=4 resonant surface. By their intersection with the divertor target plate the unstable manifolds form the footprint boundary and substructures within. Based on the manifold analysis, the boundaries and interior structures of the footprints are explained. A direct connection of all magnetic resonances inside the stochastic plasma volume to the target plates is verified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗