Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDICAL ELECTRONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Electric Potential and Electric Field Imaging with Dynamic Applications & Extensions

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field made be used for volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. Extensions to environment, Space and subterranean applications will be presented, and initial results for quantitative characterizing material properties are shown. A wearable EFI system has been developed by using fundamental EFI concepts. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, manufacturing quality control, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, weather prediction, earth quake prediction, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Modular In-Chamber Electron Beam Welding – Process Planning: Welding, Cladding, Inspection, and Manufacturing

Electron beam welding (EBW) is commonly employed by industry today to join relatively thin section components. Industrial sectors which utilize the technology include; automotive, aircraft, aerospace, defense, medical, oil & gas, etc. The ability to produce single pass, thick section (up to 6 inches, 150mm) welds has also been available for more than 40 years; however, the technology has not been deployed for civil nuclear manufacturing and fabrication such as reactor pressure vessels, steam generators, or pressurizers. Instead, thick section joining is performed much in the same manner it has been for decades using submerged arc or gas tungsten arc welding processes. Recent research performed under U.S. Department of Energy (DOE) project DE-NE0008629 has demonstrated that the overall welding time to produce one major reactor pressure vessel (RPV) girth weld can be reduced from weeks to less than 90 minutes, while maintaining exceptional quality and inspection characteristics. The subject project (DE-NE0008846) investigates a modular in-chamber (MIC) EBW approach which allows various RPV sections to be joined within a “modular” chamber. The MIC-EBW approach utilizes individual modules that can be stacked and de-stacked to various heights to enable production girth welds to be performed at a given elevation. This report describes the various processing methodology necessary to complete major girth weldments for the NuScale Power small modular reactor including welding development, manufacturing, production sequence, inspection, and cladding.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transversely pumped laser driven particle accelerator

We present a novel acceleration scheme capable of accelerating electrons and ions in an underdense plasma. Transversely Pumped Acceleration (TPA) uses multiple arrays of counter-propagating laser beamlets that focus onto a central acceleration axis. Tuning the injection timing and the spacing between the adjacent beamlets allows for precise control over the position and velocity of the intersection point of the counter-propagating beam arrays. This results in an accelerating structure that propagates orthogonal to the direction of laser propagation. We present the theory that sets the injection timing of the incoming pulses to accelerate electrons and ions with a tunable phase velocity plasma wave. Simulation results are also presented which demonstrate 1.12 GeV proton beams accelerated in 3.6 mm of plasma and electron acceleration gradients on the order of 1 TeV/m in a scheme that circumvents dephasing. This work has potential applications as a compact accelerator for medical physics and high energy physics colliders.

Laser-produced plasmas↗

Integration of High-Z Converter into Full-scale Production Target for Accelerator-based Production of 99 Mo

NorthStar Medical Technologies is planning to produce the 99Mo isotope via the photonuclear route. The Rhodotron accelerator designed by IBA will be used as an electron-beam source. The Rhodotron is an efficient recirculating accelerator, providing low energy dispersion and a low-emittance electron beam. The nominal beam power is assumed to be 120 kW at 40 MeV. In photonuclear production of 99 Mo, a high-power electron beam impinges on a helium-cooled Mo disk target. Electrons are converted into photons through the Bremsstrahlung process. Consequently, high-energy photons interact with the target nuclei, producing 99 Mo through the 100 Mo(γ, n) 99 Mo reaction. Traditionally, photonuclear production is realized using high-Z material as the electron-to-photon converter. NorthStar plans not to use a high-Z converter in the initial production target design, but it may be interested in the increased production capabilities a high-Z converter can provide. The purpose of this report is to evaluate the advantages and disadvantages of incorporating a high-Z converter into the target design.

07 ISOTOPE AND RADIATION SOURCES↗

Mo-99 Concentration and processing by Solvent Extraction and Ion Exchange

Normally derived from its transient-equilibrium parent molybdenum-99 ( 99 Mo) (t½ = 66 h), the short-lived isotope technetium-99m ( 99m Tc) (t ½ = 6.0 h) is the most widely used medical isotope in diagnostic imaging today. The National Nuclear Security Administration’s (NNSA’s) Material Management and Minimization (M3) program—established under the auspices of the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not use highly enriched uranium (HEU). Superconducting electron linear accelerators that employ high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and uranium (U) fission. Argonne, in collaboration with industrial partners, has been developing the process chemistry for superconducting linear accelerator (LINAC)-irradiated triuranium octoxide (U 3 O 8 ) targets to produce 99 Mo. In short, the process involves dissolving the irradiated targets in nitric acid, which simultaneously releases valuable fission products (xenon and iodine). After adjusting the acid concentration, producers process the feed using tri-n-butyl phosphate (TBP), then mix the raffinate derived from this extraction cycle with a phosphinic acid such as Cyanex 272 or di(2-ethylhexyl) phosphoric acid (HDEHP), which is selective for Mo (molybdenum liquid liquid extraction [MoLLE]). In the next step, a concentration column comprising an anion exchange platform is used to decontaminate the remaining fission products, generating a pure 99 Mo stream in sodium hydroxide (NaOH)/sodium chloride (NaCl).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optically Transparent Split-Ring Antennas for 1 to 10 GHz

Split-ring antennas made from optically transparent, electrically conductive films have been invented for applications in which there are requirements for compact antennas capable of operation over much or all of the frequency band from 1 to 10 GHz. Primary examples of such applications include wireless local-area networks and industrial, scientific, and medical (ISM) applications. These antennas can be conveniently located on such surfaces as those of automobile windows and display screens of diverse hand-held electronic units. They are fabricated by conventional printed-circuit techniques and can easily be integrated with solid-state amplifier circuits to enhance gain. The structure of an antenna of this type includes an antenna/feed layer supported on the top or outer face of a dielectric (e.g., glass) and, optionally, a ground layer on the bottom or inner face of the substrate. The ring can be in the form of either a conductive strip or a slot in the antenna/feed layer. The ring can be of rectangular, square, circular, elliptical, or other suitable shape and can be excited by means of a microstrip, slot line, or coplanar waveguide. For example, the antenna shown in the figure features a square conductive-strip split ring with a microstrip feed. In general, an antenna fed at its external boundary in the manner of this invention presents very high impedance, thereby creating an impedance-matching problem. Splitting the ring . that is, cutting a notch through the ring . offers a solution to the problem in that the notch fixes the location of maximum electric field, which location is directly related to the impedance. Thus, an excellent impedance match can be achieved through proper choice of the location of the notch. In geometric layout, such a ring antenna structure is typically between 1.4 and 1.3 the size of a patch antenna capable of operating in the same frequency range. This miniaturization of the antenna is desirable, not only because it contributes to overall miniaturization of equipment, but also because minimization of the extent of the optically transparent, electrically conductive film helps to minimize the electrical loss associated with the surface resistance ( 5 ohms per square) of the transparent, electrically conductive film material. Incidentally, even at 5 ohms per square, this surface resistance is significantly less than that of indium tin oxide film (typically > 25 ohms per square), which, heretofore has been the transparent, electrically conductive film material of choice. At the time of writing this article, information on the composition of the lower-resistance film used in the antennas of this invention was not available.

Lee, Richard Q.↗

Lattice Confinement Fusion & Fast Fission for Space

Lattice Confinement Fusion (LCF) 1 • Fusion of hydrogen isotopes into helium isotopes • No tokamak magnets or laser power supplies • Nuclear fuel is confined and triggered within lattice • Nuclear reactions enhanced by electron screening • Extended Electrodynamics (EED) role • NASA published results in Physical Review C 2,3 • Locally hot but globally cold • Commercialized in 2025 to produce medical radioisotopes 4 Lattice Confinement Fusion Fast-Fission Hybrid Reactor • Fusion neutrons fission uranium, spent fuel rods or thorium • No enriched uranium, cleaner fission! • Demonstrated with US Navy and GEC • Supported by NASA STMD (NIAC) and NSF Application • LEO, Deep Space Power and High I sp Propulsion • (Terrestrial)

lattice confinement fusion↗

Superconducting Accelerators for High-Power X-ray production

To date, linear accelerators (linacs) as electron sources used to produce ionizing radiation for industrial purposes have been limited to less than 100 kW. When the electron beam is used directly, this is sufficient for most potential applications. However, when the electron beam is used for the production of photons (x-rays) which are then to be used in an application, this is not sufficient to compete with other sources of photons (gamma rays from cobalt-60). This paper will discuss acompact superconducting RF (CSRF) accelerator system that relies on emerging technologies that will be able to produce electron beam powers into the 100s of kW with efficiencies much better than present linacs. The focus is to produce x-ray beams for medical device sterilization to provide alternatives for the present use of cobalt-60 for this purpose.

43 PARTICLE ACCELERATORS↗

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Trithiol ligand provides tumor-targeting 191 Pt-complexes with high molar activity and promising in vivo properties

The Auger electron-emitting radionuclide 191 Pt is a promising candidate for radiopharmaceutical therapy. Herein, we explored novel labeling methods for 191 Pt using thiol-containing ligands to improve the in vivo stability and targeting ability of 191 Pt-labeled complexes. We synthesized dithiol-containing N 2 S 2 and NS 2 ligands, and a trithiol ligand, and then compared their radiochemical reactivity with 191 Pt. [ 191 Pt]Pt-trithiol was synthesized and its biodistribution was evaluated in mice and compared with free 191 Pt. Finally, a 191 Pt-trithiol complex targeting prostate-specific membrane antigen (PSMA): [ 191 Pt]Pt-trithiol-PSMA was developed and evaluated in mice bearing tumor xenografts and compared with a 191 Pt-complex labeled via monothiol-containing Cys ([ 191 Pt]Pt-Cys-PSMA). A comparison of N 2 S 2 , NS 2 , and trithiol showed that the trithiol ligand is the best for producing 191 Pt-labeled compounds in high yield and as a single peak in preparative HPLC. Notably, the trithiol ligand made 191 Pt-labeled compounds and precursors separatable, achieving 191 Pt-labeled products with a high molar activity: 200–400 mCi/μmol (7.4–14.8 GBq/μmol) at EOS. Additionally, [ 191 Pt]Pt-trithiol and [ 191 Pt]Pt-trithiol-PSMA were stable in vivo with rapid clearance compared with free 191 Pt and [ 191 Pt]Pt-Cys-PSMA. [ 191 Pt]Pt-trithiol-PSMA resulted in a low uptake in most normal organs and a high uptake in the kidneys and prostate cancer with PSMA expression. Furthermore, this study demonstrated that a labeling method with trithiol for Pt radionuclides achieves 191 Pt-labeled products with high molar activity. 191 Pt-trithiol-PSMA showed promising in vivo stability and tumor-targeting specificity, which should facilitate the pharmaceutical development of Pt radionuclides for radiopharmaceutical therapy, especially Auger electron cancer therapy.

Auger emitters↗

Continuous assessment of metabolic activity of mitochondria using resonance Raman microspectroscopy

Dysfunctional mitochondrial activity can lead to a variety of different diseases. As such, there exists a need to quantify changes in mitochondria function as it relates to these specific diseased states. Here, we present the use of resonance Raman (RR) spectroscopy as a tool to determine changes in isolated mitochondrial activity. RR spectroscopy, using 532 nm as the excitation source, specifically provides information on the reduction and oxidation (RedOx) state of cytochrome c, which is determined by the activity of protein complexes in the electron transport chain. In this model, injection of the substrate succinate into the mitochondrial sample is used to drive the electron transport chain, which causes a subsequent change in cytochrome c RedOx state. This change in RedOx state is tracked by RR spectroscopy. We report this tool gives real-time information on the rise and fall of the amount of reduced cytochrome c within the mitochondrial sample, providing a method for rapid assessment of mitochondrial metabolism that has broad applications in both basic science and medical research.

59 BASIC BIOLOGICAL SCIENCES↗

Solvent Recovery and Management at the Savannah River Site H-Canyon Facility

NIOWAVE, Inc. is a domestic supplier of medical and industrial isotopes from uranium and radium. The Savannah River National laboratory (SRNL) is currently providing support to NIOWAVE, which plans to deploy a superconducting electron linear accelerator (LINAC) to fission uranium for Mo-99 production without the need for a nuclear reactor or HEU. The uranium from the Mo-99 production targets will be purified using a modified PUREX (Plutonium Uranium Reduction Extraction) solvent extraction process to recover the uranium in the product stream. The uranium will then be precipitated as an oxalate which is calcined to U 3 O 8 to fabricate pellets for new Mo-99 targets. In previous support provided to NIOWAVE, the SRNL demonstrated a solvent washing process to remove degradation products from the tributyl phosphate (TBP) solvent used in the modified PUREX process under development for uranium recovery. To supplement this technology demonstration, NIOWAVE requested the SRNL to provide summary information on the solvent recovery and management activities which are used at the Savannah River Site (SRS) H-Canyon facility. An existing reference document for the reprocessing of irradiated HEU fuels at the SRS was used as the primary reference for the solvent management activities; although, other reference documents were used to provide supplementary information. The information provided includes a brief summary of the solvent degradation issues which have been observed in the H-Canyon solvent extraction cycles and resulting process safety concerns. The solvent recovery processes for the three cycles of solvent extraction used in the H-Canyon were subsequently described including the process equipment which consists of the continuous and batch solvent washers, pumps, and tanks. A final section is provided on the monitoring and analysis of solvent quality based on the previous work performed at the SRNL for NIOWAVE and past research and development activities performed to support the solvent extraction processes in both the SRS F-Canyon and H-Canyon facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Testing of Helium-Cooled Metal Molybdenum Disk Target

NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

36 MATERIALS SCIENCE↗

Optical Processes behind Plasmonic Applications

Plasmonics is a revolutionary concept in nanophotonics that combines the properties of both photonics and electronics by confining light energy to a nanometer-scale oscillating field of free electrons, known as a surface plasmon. Generation, processing, routing, and amplification of optical signals at the nanoscale hold promise for optical communications, biophotonics, sensing, chemistry, and medical applications. Surface plasmons manifest themselves as confined oscillations, allowing for optical nanoantennas, ultra-compact optical detectors, state-of-the-art sensors, data storage, and energy harvesting designs. Surface plasmons facilitate both resonant characteristics of nanostructures and guiding and controlling light at the nanoscale. Plasmonics and metamaterials enable the advancement of many photonic designs with unparalleled capabilities, including subwavelength waveguides, optical nanoresonators, super- and hyper-lenses, and light concentrators. Alternative plasmonic materials have been developed to be incorporated in the nanostructures for low losses and controlled optical characteristics along with semiconductor-process compatibility. This review describes optical processes behind a range of plasmonic applications. It pays special attention to the topics of field enhancement and collective effects in nanostructures. The advances in these research topics are expected to transform the domain of nanoscale photonics, optical metamaterials, and their various applications.

2D materials↗

Superconducting Hot-Electron Submillimeter-Wave Detector

A superconducting hot-electron bolometer has been built and tested as a prototype of high-sensitivity, rapid-response detectors of submillimeter-wavelength radiation. There are diverse potential applications for such detectors, a few examples being submillimeter spectroscopy for scientific research; detection of leaking gases; detection of explosive, chemical, and biological weapons; and medical imaging. This detector is a superconducting-transition- edge device. Like other such devices, it includes a superconducting bridge that has a low heat capacity and is maintained at a critical temperature (T(sub c)) at the lower end of its superconducting-transition temperature range. Incident photons cause transient increases in electron temperature through the superconducting-transition range, thereby yielding measurable increases in electrical resistance. In this case, T(sub c) = 6 K, which is approximately the upper limit of the operating-temperature range of silicon-based bolometers heretofore used routinely in many laboratories. However, whereas the response speed of a typical silicon- based laboratory bolometer is characterized by a frequency of the order of a kilohertz, the response speed of the present device is much higher characterized by a frequency of the order of 100 MHz. For this or any bolometer, a useful figure of merit that one seeks to minimize is (NEP)(tau exp 1/2), where NEP denotes the noise-equivalent power (NEP) and the response time. This figure of merit depends primarily on the heat capacity and, for a given heat capacity, is approximately invariant. As a consequence of this approximate invariance, in designing a device having a given heat capacity to be more sensitive (to have lower NEP), one must accept longer response time (slower response) or, conversely, in designing it to respond faster, one must accept lower sensitivity. Hence, further, in order to increase both the speed of response and the sensitivity, one must make the device very small in order to make its heat capacity very small; this is the approach followed in developing the present device.

Karasik, Boris↗

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Apparatus for preparing medical radioisotopes

Apparatus for radioisotope production includes housing, a plurality of target disks inside the housing and a curved windows positioned convex inward toward the disks. During operation, coolant flows though the housing across the disks and windows while electron beams passes through the window and the disks. The window temperature increases, rising the fastest in the middle of the window where the electron beam hits the window. A flat window would buckle because the center would deform during thermal expansion against the relatively unaffected periphery, but the curved window shape allows the window to endure high thermal and mechanical stress created by a combination of heating from the electron beam(s) and elevated pressure from coolant on the inside of the window. Such a window may be used for applications in which a pressurized coolant acts on only one side of the window.

Woloshun, Keith A.↗