Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEMBRANE FORCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Cyclic strain is a weak inducer of prostacyclin synthase expression in bovine aortic endothelial cells

Recent studies indicate that hemodynamic forces such as cyclic strain and shear stress can increase prostacyclin (PGI2) secretion by endothelial cells (EC) but the effect of these forces on prostacyclin synthase (PGIS) gene expression remains unclear and is the focus of this study. Bovine aortic EC were seeded onto type I collagen coated flexible membranes and grown to confluence. The membranes and attached EC were subjected to 10% average strain at 60 cpm (0.5 sec deformation alternating with 0.5 sec relaxation) for up to 5 days. PGIS gene expression was determined by Northern blot analysis and protein level by Western blot analysis. The effect of cyclic strain on the PGIS promoter was determined by the transfection of a 1-kb human PGIS gene promoter construct coupled to a luciferase reporter gene into EC, followed by determination of luciferase activity. PGIS gene expression increased 1.7-fold in EC subjected to cyclic strain for 24 hr. Likewise, EC transfected with a pGL3B-PGIS (-1070/-10) construct showed an approximate 1.3-fold elevation in luciferase activity in EC subjected to cyclic strain for 3, 4, 8, and 12 hr. The weak stimulation of PGIS gene expression by cyclic strain was reflected in an inability to detect alterations in PGIS protein levels in EC subjected to cyclic strain for as long as 5 days. These data suggest that strain-induced stimulation of PGIS gene expression plays only a minor role in the ability of cyclic strain to stimulate PGI2 release in EC. These findings coupled with our earlier demonstration of a requisite addition of exogenous arachidonate in order to observe strain-induced PGI2 release, implicates a mechanism that more likely involves strain-induced stimulation of PGIS activity.

Non-NASA Center↗

Stamping Nanoparticles onto the Electrode for Rapid Electrochemical Analysis in Microfluidics

Electrochemical analysis is an efficient way to study various materials. However, nanoparticles are challenging due to the difficulty in fabricating a uniform electrode containing nanoparticles. We developed novel approaches to incorporate nanoparticles as a working electrode (WE) in a three-electrode microfluidic electrochemical cell. Specifically, conductive epoxy was used as a medium for direct application of nanoparticles onto the electrode surface. Three approaches in this work were illustrated, including sequence stamping, mix stamping, and droplet stamping. Shadow masking was used to form the conductive structure in the WE surface on a thin silicon nitride (SiN) membrane. Two types of nanomaterials, namely cerium oxide (CeO2) and graphite, were chosen as representative nanoparticles. The as-fabricated electrodes with attached particles were characterized using atomic force microscopy (AFM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Electrochemical analysis was performed to verify the feasibility of these nanoparticles as electrodes. Nanomaterials can be quickly assessed for their electrochemical properties using these new electrode fabrication methods in a microfluidic cell, offering a passport for rapid nanomaterial electrochemical analysis in the future.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low-cycle Fatigue and Dynamic Fracture in Gold Thin Films on SiN Supported Membranes

This slide presentation focuses on the dynamic mechanical response and fatigue behavior in sub-micron thick Au-films deposited onto amorphous Si(sub X)N(sub y) substrates, with spider-web geometry, that were subjected to forced vibration (3-axis random vibration with 2 kHz roll-off frequency). The work is to advance cyrogenic detectors that can operate at 100mK, that is required to create cryogenic detectors that are to search for present day signatures of the big bang.

fatigue↗

Deployable Wide-Aperture Array Antennas

Inexpensive, lightweight array antennas on flexible substrates are under development to satisfy a need for large-aperture antennas that can be stored compactly during transport and deployed to full size in the field. Conceived for use aboard spacecraft, antennas of this type also have potential terrestrial uses . most likely, as means to extend the ranges of cellular telephones in rural settings. Several simple deployment mechanisms are envisioned. One example is shown in the figure, where the deployment mechanism, a springlike material contained in a sleeve around the perimeter of a flexible membrane, is based on a common automobile window shade. The array can be formed of antenna elements that are printed on small sections of semi-flexible laminates, or preferably, elements that are constructed of conducting fabric. Likewise, a distribution network connecting the elements can be created from conventional technologies such as lightweight, flexible coaxial cable and a surface mount power divider, or preferably, from elements formed from conductive fabrics. Conventional technologies may be stitched onto a supporting flexible membrane or contained within pockets that are stitched onto a flexible membrane. Components created from conductive fabrics may be attached by stitching conductive strips to a nonconductive membrane, embroidering conductive threads into a nonconductive membrane, or weaving predetermined patterns directly into the membrane. The deployable antenna may comprise multiple types of antenna elements. For example, thin profile antenna elements above a ground plane, both attached to the supporting flexible membrane, can be used to create a unidirectional boresight radiation pattern. Or, antenna elements without a ground plane, such as bow-tie dipoles, can be attached to the membrane to create a bidirectional array such as that shown in the figure. For either type of antenna element, the dual configuration, i.e., elements formed of slots in a conductive membrane, can also be used. Finally, wide bandwidth antennas or arrays can be formed in which the principal direction of radiation is in the plane of the membrane. For this embodiment, the set of elements on the membrane is arranged to form one or more traveling wave antennas. In this case, a nonconductive form of the perimeter springlike material is required to provide the deploying force.

Fink, Patrick W.↗

OpenAWSEM with Open3SPN2: A fast, flexible, and accessible framework for large-scale coarse-grained biomolecular simulations

We present OpenAWSEM and Open3SPN2, new cross-compatible implementations of coarse-grained models for protein (AWSEM) and DNA (3SPN2) molecular dynamics simulations within the OpenMM framework. These new implementations retain the chemical accuracy and intrinsic efficiency of the original models while adding GPU acceleration and the ease of forcefield modification provided by OpenMM’s Custom Forces software framework. By utilizing GPUs, we achieve around a 30-fold speedup in protein and protein-DNA simulations over the existing LAMMPS-based implementations running on a single CPU core. We showcase the benefits of OpenMM’s Custom Forces framework by devising and implementing two new potentials that allow us to address important aspects of protein folding and structure prediction and by testing the ability of the combined OpenAWSEM and Open3SPN2 to model protein-DNA binding. The first potential is used to describe the changes in effective interactions that occur as a protein becomes partially buried in a membrane. We also introduced an interaction to describe proteins with multiple disulfide bonds. Using simple pairwise disulfide bonding terms results in unphysical clustering of cysteine residues, posing a problem when simulating the folding of proteins with many cysteines. We now can computationally reproduce Anfinsen’s early Nobel prize winning experiments by using OpenMM’s Custom Forces framework to introduce a multi-body disulfide bonding term that prevents unphysical clustering. Our protein-DNA simulations show that the binding landscape is funneled towards structures that are quite similar to those found using experiments. In summary, this paper provides a simulation tool for the molecular biophysics community that is both easy to use and sufficiently efficient to simulate large proteins and large protein-DNA systems that are central to many cellular processes. These codes should facilitate the interplay between molecular simulations and cellular studies, which have been hampered by the large mismatch between the time and length scales accessible to molecular simulations and those relevant to cell biology.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a New Membrane Casting Apparatus for Studying Macrovoid Defects in Low-G

A new membrane-casting apparatus is developed for studying macrovoid defects in polymeric membranes made by the wet- and dry-casting process in low-gravity. Macrovoids are large (10-50 micron), open cavities interspersed among the smaller pores in the substructure under the gelled skin surface layer of the cast membrane. Although their occurrence is considered endemic to the wet- and dry-casting process since they can lead to compaction or skin rupture in the membrane process, recent studies suggest several useful applications such as transdermal and osmotic drug delivery systems, miniature bioreactors, etc. However, lack of knowledge about the macrovoid formation mechanism is an obstacle to further development of applications using them. An on-going debate is the role of the surface-tension-driven solutocapillary convection during macrovoid formation. The rapid growth of macrovoids within 1-5 seconds and the high polymer concentration in and near macrovoids make it difficult to explain the mechanism of macrovoid growth by diffusion alone, which is the widely accepted hypothesis proposed by Reuvers et al. The hypothesis advanced by our research group can explain this rapid growth via a mechanism that involves diffusion from the casting solution in the meta-stable region to the macrovoid enhanced by solutocapillary convection induced by the steep nonsolvent concentration gradient in the vicinity of the macrovoid. Since macrovoid growth is hypothesized to be the interplay of a solutocapillary-induced driving force counteracted by viscous drag and buoyancy, eliminate the latter provides a means for testing this hypothesis. Moreover, free convection mass transfer in the nonsolvent immersion bath used to cause phase-separation in membrane casting complicates developing a model for both the wet-casting process and macrovoid growth. The low-g environment minimizes gravitationally induced free convection thereby permitting a tractable solution to the ternary diffusion equations that characterize membrane formation. NASA's Parabolic Flight Research Aircraft provides a small window of low-g (approximately 25 s) that can be used to study macrovoid development in both wet- and dry-cast membranes if an appropriate casting apparatus is used. This casting apparatus should be able to cast the membrane in both low- and high-g in a manner so that essential one-dimensional mass transfer conditions are achieved to insure lateral uniformity in the membrane. The apparatus used in previous research on membrane casting in low-gravity was operated with the plunger driven mechanism. The spring-loaded plunger pushes the bottom block containing the polymer casting solution well directly under the absorbent chamber located in the upper stationary block. However, membranes made via this casting apparatus often displayed lateral nonuniformities that precluded obtaining quantitative information on the macrovoid growth process. Thus, it was necessary to determine the reason for these structural irregularities observed in the low-g casting apparatus. Both experimental as well as computer simulation studies of the low-g casting apparatus established that the impulsive action of the plunger caused the undesired structural nonuniformities. The simulation results showed that the width-to-depth aspect ratio of the shallow well that contains the casting solution in this apparatus was not an important factor in minimizing this problem. Even for a 40:1 (width : depth) aspect ratio, any convection induced by the horizontal motion of the interface of the casting solution will be damped out within 6.25x10(exp 4) seconds. However, the experimental studies revealed that the impulsive motion of the plunger caused a 'sloshing' of the casting solution that had to be eliminated. Therefore, the plungerdriven mechanism was changed to a cam-driven mechanism that did not cause any impulsive motion of the casting solution. Other refinements to this new membrane-casting apparatus include provision for removing the membranes from the casting wells in a less destructive manner. This was accomplished by using a slit geometry for the casting well that permitted disassembly for removal of the cast membrane. The materials used in the construction of this casting apparatus were chosen to insure wetting at the side walls and to maintain precise control of the thickness of the polymer solution in the casting well. An additional provision in this new casting apparatus is the ability to carry out both wet- as well as dry-casting. As such, this apparatus permitted the first studies of the wet-casting of polymeric membranes in low-g. Both wet- and dry-casting experiments on NASA's KC-135 research aircraft employing this new membrane-casting apparatus are scheduled in July 2002. The morphology of the resulting membranes will be characterized using an environmental scanning electron microscope (ESEM). The results of these low-g studies will be reported later.

Lee, Hanyong↗

Effect of docetaxel on mechanical properties of ovarian cancer cells

Docetaxel could inhibit the proliferation of tumor cells by targeting microtubules. The extension of cellular microtubules plays an important role in the invasion and metastasis of tumor cells. This paper aims to study the distribution and mechanical properties of cytoskeletal proteins with low concentration of docetaxel. MTT assay was used to detect the minimum drug activity concentration of docetaxel on SKOV-3 cells, fluorescence staining was used to analyze the distribution of cytoskeleton proteins, scanning electron microscopy(SEM) was used to observe the morphology of single cells, and atomic force microscopy(AFM) was used to determine the microstructure and mechanical properties of cells. The results showed that the IC{sub 10} of docetaxel was 1 ng/ml. Docetaxel can effectively inhibit the formation of cell pseudopodia, hinder the indirectness between cells, reduce the cell extension area, and make the cells malformed. In addition, when AFM analyzes the effects of drugs on cell microstructure and mechanical properties, the average cell surface roughness and cell height are positively correlated with the concentration of docetaxel. Especially when the concentration was 100 ng/ml, the adhesion decreased by 37.04% and Young's modulus increased by 1.57 times compared with the control group. This may be because docetaxel leads to microtubule remodeling and membrane protein aggregation, which affects cell microstructure and increases cell strength, leading to significant changes in the mechanical properties of ovarian cells. This is of great significance to the study of the formation mechanism of tumor cell invasion and migration activities mediated by actin.

60 APPLIED LIFE SCIENCES↗

Hydration-Controlled Proton Transport in Respiratory Complex I

Proton pumping by respiratory complex I is one essential element for generating the proton motive force that drives ATP synthesis in mitochondria. Although it is understood that electrons from NADH reduce ubiquinone at the peripheral arm and that four protons are transferred in the membrane domain, the mechanism by which this redox reaction initiates proton translocation remains unclear. A lateral pathway linking the quinone binding site to the membrane domain via ND1, ND3, and ND4L subunits has been proposed as a possible initial path of an excess proton. However, experimental structures indicate that the hydration connectivity between D66 ND3 and E34 ND4L is comparatively weaker than in neighboring segments, suggesting a potential regulatory point for proton transfer. Using multiscale reactive molecular dynamics (MS-RMD) and a water wire connectivity metric, we directly simulate proton transport through this region as coupled to the hydration by water molecules. Our results reveal that proton transfer is thermodynamically feasible when transient hydration aligns with the presence of an excess proton, revealing the strong coupling between hydration and proton transfer (PT) in this region of Complex I. These findings support a model where proton injection enhances local hydration, dynamically opening the pathway for proton transfer and regulating the onset of proton pumping in Complex I.

Chemical structure↗

A novel method for producing microspheres with semipermeable polymer membranes

A new and systematic approach for producing polymer microspheres has been demonstrated. The membrane of the microsphere is formed by immersing the polyanionic droplet into a collapsing annular sheet, which is made of another polycation polymer solution. This method minimizes the impact force during the time when the chemical reaction takes place, hence eliminating the shortcomings of the current encapsulation techniques. The results of this study show the feasibility of this method for mass production of microcapsules.

Lin, K. C.↗

Fabrication of Microshutter Arrays for James Webb Space Telescope

Two-dimensional MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use in the near-infrared region on the Next Generation Space Telescope (NGST). The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast. The NGST environment requires cryogenic operation at 45K. Microshutter arrays are fabricated out of silicon-oxide-insulated (SOI) silicon wafers. Arrays are close-packed silicon nitride membranes with a pixel size of 100x100 microns. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. The mechanical shutter arrays are fabricated using MEMS technologies. The processing includes a multi-layer metal deposition and patterning of shutter electrodes and magnetic pads, reactive ion etching (RE) of the front side to form shutters out of the nitride membrane, an anisotropic back-etch for wafer thinning, followed by a deep RIE (DRIE) back-etch down to the nitride shutter membrane to form frames and relieve shutters from the silicon substrate. An additional metal deposition and patterning is used to form back electrodes. Shutters are actuated using a magnetic force and latched using an electrostatic force.

Li, Mary J.↗

Exponential Water Uptake in Ionomer Membranes Results from Polymer Plasticization

Water content is the most influential factor in the performance of ion-exchange membranes (IEMs), controlling their mechanical rigidity, ionic conductivity, and degradation rates. Membranes absorb water exponentially at high water activity (a w ), making that region of the sorption isotherm the most influential on membrane properties. Plasticization of the polymer by water has been proposed to cause this exponential uptake at high a w . However, an integrated microscopic picture of the structure, thermodynamic, and mechanical properties of IEMs as a function of a w has remained elusive. In this work, we use large-scale molecular simulations validated with experimental measurements to compute the sorption isotherms, Young’s modulus, polymer dynamics, and structure of IEMs. The simulations unveil that the exponential increase in water uptake (WU) coincides in all cases with the glass to rubber transition of the membrane, as measured through its Young’s modulus and segmental polymer dynamics. Functionalization of the polymer with alkyl groups further contributes to its plasticization, increasing the WU at a given a w and ion-exchange capacity (IEC). The alkyl chains act synergistically with water to plasticize the polymer matrix and allow water penetration in the membrane. The simulations reveal that the width of the water channels depends on the ratio λ of water to ions in the polymer but is independent of its IEC. We conclude that differences in the polymer matrix–not the water channels–are responsible for the distinct uptake response of IEMs to the thermodynamic driving force of water activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding and Manipulating Counterion Condensation within Charged Polymer Electrolytes for Selective and Low Resistant Membrane Separations

Polymeric ion-exchange membranes are found at the heart of numerous electrochemical systems spanning separations (electrodialysis and membrane capacitive deionization) and energy conversion and storage (flow batteries, fuel cells, and electrolyzers). The ion-exchange membrane separators need to be ion conducting but electron insulating, and in many scenarios selective for a particular ion to conduct. Because of their polymeric nature, the molecular architectures of ion-exchange membranes lack the molecular precision found in many inorganic materials. Plus, they contain numerous structural defects that impede ionic transport. As a result of their poor structure, it has been difficult to carefully probe the underlying physics that governs ion transport in ion-exchange membranes. We investigated counterion condensation phenomena in ion-exchange membranes and correlated it to bulk ionic charge transport and selectivity in precisely defined and long-range ordered materials afforded through the principles of directed self-assembly. A multi-faceted approach spanning i.) advanced metrology, two-dimensional atomic force microscopy, x-ray scattering, and ion-exchange equilibria, and ii.) molecular simulations (classical molecular dynamics and ab-inito molecular dynamics) that bridge multiple time and length scales, were employed to correlate the extent of counterion condensation to ionic conductivity and selectivity. After uncovering the extent of the condensation phenomena in this project, new macromolecular chemistries were employed to manipulate the ion pairing interactions of the condensed counterions to tethered ions on the polymer backbone so more facile and selective conduction rates can be attained. The research has aided in the rational design of polymeric ion-exchange membrane separators with high current density for electrochemical systems and subsequently better energy efficiency.

36 MATERIALS SCIENCE↗

Biaxial steel plated concrete constitutive models for composite structures: Implementation and validation

The Steel-plated Concrete (SC) technique is an alternative construction technique with faster onsite construction speed, reduced construction time, and increased structural performance. Aiming to predict the force transfer mechanism of SC elements, an innovative constitutive model package is proposed by implementing experimental-based biaxial steel plate concrete models into the nonlinear finite element (FE) model “Membrane Model of SC (MM-CS).” First, the formulation and implementation of the MM-SC is illustrated in detail, including the equilibrium and compatibility equations and the implementation of constitutive models. Next, various experimental data of SC members are selected and simulated using the proposed MM-SC model. In this research, two types of structures, SC panels and framed SC shear walls, and three types of loading conditions, including uniaxial compression, pure shear, and combined axial-flexural-shear tests, are analyzed respectively. Good agreements were obtained between the reported results and the FE simulation results in terms of yield capacity and ultimate capacity, proving the reliability of the implemented analytical constitutive material models and the biaxial membrane model formulations.

42 ENGINEERING↗

Exfoliation of surfactant swollen layered MWW zeolites into two-dimensional zeolite nanosheets using telechelic liquid polybutadiene

We report two-dimensional (2D) zeolites have the potential to enhance mass transport by reducing diffusion lengths and thus find applications in catalysis and separation. High aspect ratio 2D zeolite nanosheets are required for fabrication of thin, high-flux zeolite membranes. Preparation of 2D zeolite nanosheets can be achieved by exfoliation of layered zeolite precursors, which usually requires multiple steps including swelling with cationic surfactants, exfoliation by applying a mechanical force such as shearing or sonication, purification and removal of the surfactants. The exfoliation of surfactant swollen layered zeolite precursors has been studied using molten polystyrene and telechelic liquid polybutadiene, but still requires extensive shearing force. Recently, a novel one-step exfoliation method has been developed for nonswollen MWW zeolite precursors using tetrabutylammonium hydroxide (TBAOH) solution. In this work, we study the exfoliation of surfactant swollen MWW layered precursors (with and without aluminum) in commercially available liquid hydroxyl-terminated polybutadiene (HTPB) with the aim to provide fundamental understanding of the interaction between the liquid polybutadiene and the surfactant swollen layered zeolite precursors. It was found that surfactant swollen ITQ-1, (ITQ-1(S)), a pure silica layered precursor with MWW framework after being swollen with a cationic surfactant, can be exfoliated in liquid HTPB at room temperature without applying any additional shearing force. The aluminum containing surfactant swollen MWW precursors can be also exfoliated in HTPB at room temperature, but require additional shearing forces. The exfoliation process was monitored using rheology experiments and studied by tuning the composition of the zeolite precursors. The interaction between the layered zeolite precursor and the hydroxyl group of the liquid polybutadiene allows the polymer to intercalate the precursor and exfoliate it into nanosheets. The presence of framework aluminum and the nature of the organic structure directing agents (OSDAs) are key parameters affecting the exfoliation process. Framework Al is unfavorable for the exfoliation possibly due to the surface charges introduced by the aluminum. Bulky OSDA, trimethyladamantammonium (TMAda + ), in the interlayer spacing may facilitate the exfoliation.

2D nanosheets↗

Challenges of conventional iterative all-atom and coarse-grained multiscale molecular dynamics

In this work, we evaluate the biomolecular dynamics behaviors when conventionally iterating between all-atom (AA) and coarse-grained (CG) molecular dynamics (MD) simulations over multiple cycles. We implemented the workflow to iterate between AA and CG in OpenMM, namely the iterative multiscale MD (iMMD) simulation workflow. In particular, we aim to identify practical applications for iterating between AA and CG simulations in a conventional manner without any constraints or model modifications. We evaluate the iMMD workflow on four representative systems, spanning folding of two soluble proteins and protein-protein as well as protein-lipid interactions of two membrane proteins. We observe that iteration between AA and CG representations could help the soluble proteins exit undesirable metastable states to fold, resulting from random protein structural distortions due to cycling. Consequently, the most reliable use of iterative AA and CG simulations appears to be to accelerating complex lipid mixing for membrane-bound protein systems rather than sampling protein conformational space. Our work explores the practical usages and limitations for iterative AA and CG simulations using readily available AA and CG force fields. The evaluated iMMD workflow in OpenMM is made available at https://github.com/lanl/iMMD.

59 BASIC BIOLOGICAL SCIENCES↗

NASA Tech Briefs, October 2012

Topics discussed include: Detection of Chemical Precursors of Explosives; Detecting Methane From Leaking Pipelines and as Greenhouse Gas in the Atmosphere; Onboard Sensor Data Qualification in Human-Rated Launch Vehicles; Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride; A Probabilistic Mass Estimation Algorithm for a Novel 7-Channel Capacitive Sample Verification Sensor; Low-Power Architecture for an Optical Life Gas Analyzer; Online Cable Tester and Rerouter; A Three-Frequency Feed for Millimeter-Wave Radiometry; Capacitance Probe Resonator for Multichannel Electrometer; Inverted Three-Junction Tandem Thermophotovoltaic Modules; Fabrication of Single Crystal MgO Capsules; Inflatable Hangar for Assembly of Large Structures in Space; Mars Aqueous Processing System; Hybrid Filter Membrane; Design for the Structure and the Mechanics of Moballs; Pressure Dome for High-Pressure Electrolyzer; Cascading Tesla Oscillating Flow Diode for Stirling Engine Gas Bearings; Compact, Low-Force, Low-Noise Linear Actuator; Ultra-Compact Motor Controller; Extreme Ionizing-Radiation-Resistant Bacterium; Wideband Single-Crystal Transducer for Bone Characterization; Fluorescence-Activated Cell Sorting of Live Versus Dead Bacterial Cells and Spores; Nonhazardous Urine Pretreatment Method; Laser-Ranging Transponders for Science Investigations of the Moon and Mars; Ka-Band Waveguide Three-Way Serial Combiner for MMIC Amplifiers; Structural Health Monitoring with Fiber Bragg Grating and Piezo Arrays; Low-Gain Circularly Polarized Antenna with Torus-Shaped Pattern; Stereo and IMU- Assisted Visual Odometry for Small Robots; Global Swath and Gridded Data Tiling; GOES-R: Satellite Insight; Aquarius iPhone Application; Monitoring of International Space Station Telemetry Using Shewhart Control Charts; Theory of a Traveling Wave Feed for a Planar Slot Array Antenna; Time Manager Software for a Flight Processor; Simulation of Oxygen Disintegration and Mixing With Hydrogen or Helium at Supercritical Pressure; A Superfluid Pulse Tube Refrigerator Without Moving Parts for Sub-Kelvin Cooling; Sapphire Viewports for a Venus Probe; The Mobile Chamber; Electric Propulsion Induced Secondary Mass Spectroscopy; and Radiation-Tolerant DC-DC Converters.

Source record↗

Bubble Eliminator Based on Centrifugal Flow

The fluid bubble eliminator (FBE) is a device that removes gas bubbles from a flowing liquid. The FBE contains no moving parts and does not require any power input beyond that needed to pump the liquid. In the FBE, the buoyant force for separating the gas from the liquid is provided by a radial pressure gradient associated with a centrifugal flow of the liquid and any entrained bubbles. A device based on a similar principle is described in Centrifugal Adsorption Cartridge System (MSC- 22863), which appears on page 48 of this issue. The FBE was originally intended for use in filtering bubbles out of a liquid flowing relatively slowly in a bioreactor system in microgravity. Versions that operate in normal Earth gravitation at greater flow speeds may also be feasible. The FBE (see figure) is constructed as a cartridge that includes two concentric cylinders with flanges at the ends. The outer cylinder is an impermeable housing; the inner cylinder comprises a gas-permeable, liquid-impermeable membrane covering a perforated inner tube. Multiple spiral disks that collectively constitute a spiral ramp are mounted in the space between the inner and outer cylinders. The liquid enters the FBE through an end flange, flows in the annular space between the cylinders, and leaves through the opposite end flange. The spiral disks channel the liquid into a spiral flow, the circumferential component of which gives rise to the desired centrifugal effect. The resulting radial pressure gradient forces the bubbles radially inward; that is, toward the inner cylinder. At the inner cylinder, the gas-permeable, liquid-impermeable membrane allows the bubbles to enter the perforated inner tube while keeping the liquid in the space between the inner and outer cylinders. The gas thus collected can be vented via an endflange connection to the inner tube. The centripetal acceleration (and thus the radial pressure gradient) is approximately proportional to the square of the flow speed and approximately inversely proportional to an effective radius of the annular space. For a given FBE geometry, one could increase the maximum rate at which gas could be removed by increasing the rate of flow to obtain more centripetal acceleration. In experiments and calculations oriented toward the original microgravitational application, centripetal accelerations between 0.001 and 0.012 g [where g normal Earth gravitation (.9.8 m/s2)] were considered. For operation in normal Earth gravitation, it would likely be necessary to choose the FBE geometry and the rate of flow to obtain centripetal acceleration comparable to or greater than g.

Gonda, Steve R.↗