Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Development of Resistive Electrode Gas Electron Multiplier (RE-GEM)

We successfully produced Resistive-Electrode Gas Electron Multiplier (RE-GEM) which has resistive electrodes instead of the metal ones which are employed for the standard GEM foils. RE-GEM has a resistive electrode of 25 micron-thick and an insulator layer of 100 micron-thick. The hole structure of RE-GEM is a single conical with the wider and narrower hole diameters of 80 micron and 60 micron, respectively. A hole pitch of RE-GEM is 140 micron. We obtained the maximum gain of about 600 and the typical energy resolution of about 20% (FWHM) at an applied voltage between the resistive electrodes of 620 V, using a collimated 8 keV X-rays from a generator in a gas mixture of 70% Ar and 30% CO2 by volume at the atmospheric pressure. We measured the effective gain as a function of the electric field of the drift region and obtained the maximum gain at an drift field of 0.5 kV/cm.

detectors↗

Lifetimes of Multiply Alkylated Cyclopentane Oil in Contact with Various Metals, Evaluated with Vacuum Spiral Orbit Tribometer

The dependence of the lifetimes of small quantities of a Multiply Alkylated Cyclopentane (MAC) lubricant oil, Pennzane (Registered Trademark) 2001A (Nye Lubricants, Inc.), in rolling and sliding contact with different metals was evaluated with a vacuum spiral orbit tribometer. The metals were the bearing alloys 52100 steel, 440C steel, 17-4 PH steel and Nitinol 60 and the elements chromium, vanadium and titanium. The lifetimes of the lubricant oil on different metals fell into distinct groups with 52100 greater than 440C approx. Nitinol 60 greater than 17-4 PH for the order of the lifetimes of the steels and chromium greater than vanadium greater than titanium for the order of the lifetimes for the elements. The limited life of the small quantities of oil is assumed to be due to its consumption by the tribochemical reaction of the oil with the different metal bearing materials. The lifetimes are then inversely related to the reaction rates of the oil molecules with the various metals: the longest life of 52100 steel having the lowest reaction rate and the shortest life of titanium having the highest reaction rate. Mechanisms for the tribochemical reactions are discussed.

lubrication↗

Maturing Electron Multiplying Charge Coupled Device Photon-Counting with Variable Multiplication Gain Imaging for a Coronagraphic Instrument

This is an introduction to a US Government Program that conducted high-contrast imaging experiments with an Electron Multiplying Charge Coupled Device (EMCCD) in an interferometric coronagraph. This report will introduce the concepts of “Charge Blooming” and “Starlight Saturation” in the context of high-contrast astronomical imaging. These phenomena adversely affect the performance of high-contrast photon-counting instruments that do not use a mask to physically block starlight in the science channel of the coronagraph. The problems will be presented with the help of images taken with a commercial EMCCD camera in the Visible Nulling Coronagraph at the Goddard Space Flight Center (GSFC). A new clocking scheme for EMCCDs – Variable Multiplication Gain Clocking – will be proposed as a means for suppressing horizontal blooming and starlight saturation in an astronomical camera. This opening report from the program will conclude with an introduction to a new controller for high-contrast imaging with EMCCDs in coronagraphs. This controller is being designed to allow a single frame from an EMCCD to be scanned in multiple modes – photon counting and digitization – to enable direct imaging of an exo-planet and wavefront control of a coronagraph, simultaneously.

Udayan Mallik↗

Status of the Multiply-Charged Ion Research Facility at JPL

In order to provide a better understanding of the energy balance and ion composition in solar, stellar, and planetary atmospheres, and in the interstellar medium, a new research facility for the study of interactions of multiply-charged ions has been developed at the Jet Propulsion Laboratory (JPL).

charged↗