Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Field Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Measurement of Local Electric Field Turbulence in Magnetically Confined Plasmas (Final Report)

This final report describes the development of high-bandwidth plasma fluctuation diagnostics, encompassing the design and implementation of Beam Emission Spectroscopy systems on several fusion experiments such as TFTR, DIII-D and NSTX, the advancement of Alpha particle and Ultrafast Charge-Exchange Recombination Spectroscopy, and the creation of advanced spectrometers for localized studies of electric and magnetic field fluctuations based on the Motional Stark Effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Terahertz inverse spin Hall effect in spintronic nanostructures with various ferromagnetic materials

Bilayers of ferromagnetic and heavy metal nanolayers excited with femtosecond laser pulses emit subpicosecond bursts of electromagnetic radiation with spectral frequencies up to several THz. We fabricated such spintronic THz emitters containing various ferromagnetic materials with vastly different magnetic remanence, saturation magnetization, and coercive fields. In all cases, the THz amplitude versus magnetic-field dependence follows the independently measured magnetization hysteresis loops and the THz polarization direction is perpendicular to the sample’s magnetization M, both consistent with the inverse spin Hall effect (ISHE) as the physical origin. The mV-level signals of observed THz transient also favor the ISHE over the anomalous Nernst effect (ANE). The M(T) variation governs the temperature dependence of the THz generation. Emitters with weakly remanent ferromagnets are magnetic-field tunable, while moderately and strongly remanent ferromagnets, once magnetized, allow intense THz generation even without an external field, nevertheless exhibiting low susceptibility to magnetic perturbations if the hysteresis loop is square. Hence, exploiting the magnetic properties of the ferromagnetic layer enables tailoring of weakly temperature-dependent spintronic THz emitters. Finally, we explored the applicability of perovskite oxide materials such as La-Sr-Mn-O (LSMO) for THz transient generation. We detected weak (<40-μV amplitude) THz emissions from both LSMO/Au and pure LSMO nanostructures with no sign flip upon the sample reversal. Furthermore, we excluded the ISHE and believe it was likely governed by the ANE in the thick-film regime, although we cannot exclude the transient demagnetization mechanism.

36 MATERIALS SCIENCE↗

Fabrication and Test of C3a: A Six-Layer Subscale Canted $\cos \theta$ Dipole Magnet Using High-Temperature Superconducting corc Wires

REBCO coated conductors have a strong potential for high-field magnet applications. The REBCO technology, however, is still in its infancy for accelerator magnet applications. As part of the U.S. Magnet Development Program (MDP), we developed a six-layer canted cos θ dipole magnet, C3a, using CORC® wires developed by Advanced Conductor Technologies LLC. All the layers were wound using a semi-automated winding machine. Three layers of the magnet used CORC® wires containing the SuperPower “AP” REBCO tapes and the remaining layers used the wires containing the “HM” tapes. At 77 K, both kinds of CORC® wires showed 5% to 10% degradation, after bending to a minimum bend radius of 30 or 35 mm, with respect to the self-field critical current measured before winding. At 4.2 K, the magnet reached 9.5 kA at a ramp rate of 9 A s -1 and generated a dipole field of 1.4 T. Further, the critical current of one layer degraded by 4% after a current transient up to 10.5 kA ramped in an averaged rate of 175 kA s -1 or 20 T s -1 . We confirmed the HM CORC® wire can carry a higher current than the AP CORC® wire at 4.2 K. The test results of the C3a magnet showed that the fabrication and assembly procedure can be used for the upcoming full-scale C3 magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-contact based measurement of thin film coatings using eddy current measurements

When a time varying magnetic field attempts to penetrate a conductive surface, the surface will respond to that time varying field by the generation of circular currents around the flux lines. This effect is described by Faraday’s law of induction. An eddy current based measurement system attempts to discern the power loss incurred by these circulating currents within the conductive surface. The measurement system described here uses an Agilent E 4980A LCR meter to quantify the reaction of the film to the high frequency magnetic field lines which are forced into the film. The measurement metric is the meter’s interpretation of the power dissipation caused by the measured film. The meter is setup to use the Ls/Rs inductor model, and is run at 1 Mhz to bring the losses within the film as high as possible for sensitivity.

43 PARTICLE ACCELERATORS↗

Spatially resolved measurements of plasma ion velocity distributions in a dipole magnetic field

The equilibrium flows of a plasma discharge in a dipole magnetic field are a topic of interest in low temperature plasma physics. Experimentalists typically rely on probe-based and line-integrated diagnostic techniques in these environments to describe plasma behavior. Presented here are measurements of argon ion dynamics with laser induced fluorescence techniques to provide insight into plasma dynamics in dipole magnetic fields with nonperturbative, spatially localized measurements. Simulation results from a Lagrangian approach to track particle orbits are compared to measured density profiles and provide evidence to support the mechanism distinguishing experimental configurations is the initial approach of particles. Applying a negative DC bias to the magnet induces strong E×B flows around the magnet, even exceeding the ion acoustic speed as measured far from the magnet. A strong enough bias also produces two distinct ion populations and provides a method for controlling the density gradient on the equator.

McLaughlin, Jacob W. (ORCID:0000000152661888)↗

Magnetic glassiness in noncentrosymmetric Sm 7 Pd 3 : Interplay of magnetic frustration, long-range order, and frozen domains

Here, we present a comprehensive investigation of the intricate spin dynamics in the noncentrosymmetric compound Sm 7 ⁢Pd 3 , revealing the coexistence of spin-glass, domain-glass, and ferromagnetic (FM) behaviors. Magnetic field-dependent measurements indicate large coercivity, suggesting ferromagnetic domain formation below the Curie temperature (𝑇 C ≈ 173 K), while temperature-dependent magnetization data point to antiferromagnetic (AFM) coupling, highlighting the competition between FM and AFM interactions. Detailed ac susceptibility, isothermal remanent magnetization, and aging effect measurements demonstrate the presence of two distinct types of glassiness in the sample, and their possible origins are discussed extensively. Magnetization measurements reveal the mixing of the 𝐽 = 5/2 ground state of Sm 3+ with the excited 𝐽 = 7/2 multiplet, lying 965 K above. The specific heat data show further crystalline electric field splitting of the 𝐽 = 5/2 state into a ground-state doublet and a fourfold-degenerate excited state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Constraining the Charge-Sign and Rigidity-Dependence of Solar Modulation

Our ability to identify the sources of cosmic rays and understand how these particles propagate through the interstellar medium is hindered by the combined effects of the solar wind and its embedded magnetic field, collectively known as solar modulation. In this paper, we build upon our previous work to model and constrain the effects of solar modulation on the cosmic-ray spectrum, using data from AMS-02 and BESS Polar II collected between 2007 and 2012, during which the heliospheric magnetic field was in a state of negative polarity. Our model uses measurements of the heliospheric magnetic field and the tilt angle of the heliospheric current sheet to accurately predict the effects of solar modulation as a function of time, charge, and rigidity. By incorporating data from a period of negative polarity, we have been able to robustly observe and constrain the charge-dependent effects of solar modulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining Magnetic Field Directions and Omni-directional Fluxes of Particles from STPSat-6 ZPS Plasma Measurements

This report summarizes our recent data derivation efforts on STPSat-6 ZPS plasma measurements, presenting final outcomes. We begin by outlining the methodology developed to determine local magnetic field directions from measured directional intensities of ~20 keV ions, leveraging symmetry in particles’ pitch-angle distributions, and the determined field directions over a storm period are shown with errors analyzed through comparison with NOAA GOES measurements. Next, we further assess the validity of the method and quantify its overall high performance while acknowledging certain caveats. Finally, given local magnetic field directions and ZPS data, we explain how omni-directional fluxes of particles can be derived from ZPS measurements with limited directional coverage, and estimate the related errors under several theoretical scenarios. The methods developed in this study can be applied for processing and augmenting ZPS data for the next, and the insights gained here can also inform instrument design in the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interface roughness governed negative magnetoresistances in two-dimensional electron gases in AlGaN/GaN heterostructures

Negative magnetoresistances (NMRs) have been widely observed in two-dimensional electron gases (2DEGs). However, their origins are under debate. Here, we report on NMRs in the 2DEG in AlGaN/GaN heterostructures, aiming to uncover their origins by utilizing electric field gating. We systematically measured the magnetoresistances in magnetic fields up to 12 T and at temperatures between 3 and 260 K and observed NMRs over a wide range of temperatures from 3 to 170 K, which become more pronounced with decreasing temperature. We conducted electric field gating experiments to correlate the occurrence of NMRs with the relationship between electron mobility and density. The latter is governed by defect scattering sources in the sample and can be theoretically modeled. Comparison of the measured electron mobility and electron density relationship with theory reveals that interface roughness scattering plays a crucial role in obtaining large NMRs. Our work demonstrates that electric field gating provides a means not only to tune the values of NMRs but also to uncover their mechanisms.

2-dimensional systems↗

Exciton–Polaritons in CsPbBr 3 Crystals Revealed by Optical Reflectivity in High Magnetic Fields and Two-Photon Spectroscopy

Cesium lead bromide (CsPbBr3) is a representative material of the emerging class of lead halide perovskite semiconductors that possess remarkable optoelectronic properties. Its optical properties in the vicinity of the bandgap energy are greatly contributed by excitons, which form exciton polaritons due to strong light–matter interactions. Exciton–polaritons in solution-grown CsPbBr 3 crystals are examined by means of circularly polarized reflection spectroscopy measured in high magnetic fields up to 60 T. The excited 2P exciton state is measured by two-photon absorption. Comprehensive modeling and analysis provides detailed quantitative information about the exciton–polariton parameters: exciton binding energy of 32.5 meV, oscillator strength characterized by longitudinal–transverse splitting of 5.3 meV, damping of 6.7 meV, reduced exciton mass of 0.18$m$ 0 , exciton diamagnetic shift of 1.6 μeV T -2 , and exciton Landé factor $g$ x = + 2.35. It is shown that the exciton states can be described within a hydrogen-like model with an effective dielectric constant of 8.7. From the measured exciton longitudinal–transverse splitting, Kane energy of E p = 15 eV is evaluated, which is in reasonable agreement with values of 11.8–12.5 eV derived from the carrier effective masses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of the electron energy distribution function in partially magnetized low temperature plasmas

While Langmuir probes (LPs) are relatively simple and inexpensive plasma diagnostics for the electron density, temperature, and the electron energy distribution function (EEDF), the interpretation of the measured current–voltage (I–V) characteristic is complicated considerably by the presence of a magnetic field. In regimes where the electron gyroradius is comparable to the probe radius, the electron flux to the probe surface is retarded by reduced mobility across field lines and can no longer be described by a thermal model. Predicting the current collected by the probe in these regimes requires accurate estimates of the plasma diffusion coefficients, which are usually difficult to obtain. In this work, we measure electron energy distribution functions in E×B plasmas with magnetized electrons and non-magnetized ions in argon and krypton gases, using both a LP and laser Thomson scattering (LTS) at various magnetic fields. Using the LTS measurements to provide a robust benchmark for comparison, we compare existing theories describing the flux to the probe under magnetized conditions. We find that even when the electron gyroradius associated with the effective electron temperature is small compared to the probe radius, the EEDF computed using classical probe theory is still robust at energies higher than the energy at which the gyroradius becomes larger than the probe size. For plasmas that are not strongly non-Maxwellian, we formulate a method to extract robust density and temperature measurements using physics-informed fitting techniques to analyze EEDFs computed using classical theory.

Devin, E. G. [Princeton Plasma Physics Laboratory ↗

An assessment of controlled source EM for monitoring subsurface CO 2 injection at the wyoming carbonSAFE geologic carbon storage site

Here we evaluate if electromagnetic (EM) geophysical methods for monitoring geologic carbon storage (GCS) efforts at the Wyoming CarbonSAFE project adjacent to the Dry Fork Station power plant near Gillette, Wyoming. This first involved acquiring both electric and magnetic fields at eleven different locations ranging in distance from immediately adjacent to 4 km from the plant. Passive EM measurements were made to provide spectral EM noise measurements generated by electricity production at the plant and to determine if useful magnetotelluric (MT) data can be successfully collected in the region. The processed data indicate that useful MT data can be collected as long as the site is located more than 2km away from the power plant as well as active roads and rail lines. Controlled source EM data were collected using three different source configurations, two of which connected to steel casings used to complete the injection wells. Comparing the EM noise measurements to the CSEM data show measurable electric and magnetic field signals at all sites. Next a series of three-dimensional (3D) numerical models were built that simulate resistivity changes caused by the proposed CO2 injection at depths ranging from 2.4 to 3.0km. These models were used to simulate various EM measurement configurations. The modeling shows that casing-source CSEM monitoring can provide sensitivity to the injected CO 2 if source electrodes are connected to the bottom of one or both of the injection wells.

58 GEOSCIENCES↗

Direct computation of magnetic surfaces in Boozer coordinates and coil optimization for quasisymmetry

We propose a new method to compute magnetic surfaces that are parametrized in Boozer coordinates for vacuum magnetic fields. We also propose a measure for quasisymmetry on the computed surfaces and use it to design coils that generate a magnetic field that is quasisymmetric on those surfaces. The rotational transform of the field and complexity measures for the coils are also controlled in the design problem. Using an adjoint approach, we are able to obtain analytic derivatives for this optimization problem, yielding an efficient gradient-based algorithm. Starting from an initial coil set that presents nested magnetic surfaces for a large fraction of the volume, our method converges rapidly to coil systems generating fields with excellent quasisymmetry and low particle losses. In particular for low complexity coils, we are able to significantly improve the performance compared with coils obtained from the standard two-stage approach, e.g. reduce losses of fusion-produced alpha particles born at half-radius from $17.7\,\%$ to $6.6\,\%$ . We also demonstrate 16-coil configurations with alpha loss ${<}1\,\%$ and neoclassical transport magnitude $\epsilon _{\text {eff}}^{3/2}$ less than approximately $5\times 10^{-9}$ .

Physics↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

Magnetic, thermal, and electronic-transport properties of EuMg 2 Bi 2 single crystals

The trigonal compound EuMg 2 Bi 2 has recently been discussed in terms of its topological band properties. These are intertwined with its magnetic properties. In this paper detailed studies of the magnetic, thermal, and electronic-transport properties of EuMg 2 Bi 2 single crystals are presented. The Eu + 2 spins 7/2 in EuMg 2 Bi 2 exhibit an antiferromagnetic (AFM) transition at a temperature T N = 6.7 K, as previously reported. By analyzing the anisotropic magnetic susceptibility χ data below T N in terms of molecular-field theory (MFT), the AFM structure is inferred to be a c -axis helix, where the ordered moments in the hexagonal a b -plane layers are aligned ferromagnetically in the a b plane with a turn angle between the moments in adjacent moment planes along the c axis of ≈ 120 ° . An alternate but less likely magnetic structure is a planar structure with nearest-neighbor Eu spins aligned at ≈ 120 ° with respect to each other, where these ordered-moment layers are stacked along the c axis. The magnetic heat capacity exhibits a λ anomaly at T N with evidence of dynamic short-range magnetic fluctuations both above and below T N . The high- T limit of the magnetic entropy is close to the theoretical value for spins 7/2. The in-plane electrical resistivity ρ ( T ) data indicate metallic character with a mild and disorder-sensitive upturn below T min = 23 K. An anomalous rapid drop in ρ ( T ) on cooling below T N as found in zero field is replaced by a two-step decrease in magnetic fields. The ρ ( T ) measurements also reveal an additional transition below T N in applied fields of unknown origin that is not observed in the other measurements and may be associated with an incommensurate to commensurate AFM transition. The dependence of T N on the c -axis magnetic field H ⊥ was derived from the field-dependent χ ( T ) , C p ( T ) , and ρ ( T ) measurements. This T N ( H ⊥ ) was found to be consistent with the prediction of MFT for a c -axis helix with S = 7 / 2 and was used to generate a phase diagram in the H ⊥ – T plane.

36 MATERIALS SCIENCE↗

A Field Quality Modeling in Canted Cosine Theta Dipole Magnets Wound Using REBCO Cables

In accelerator magnets the magnetic field quality is an important parameter. Using REBCO tapes or cables in magnet windings affects the magnetic field quality because of a quite high magnetization generated by these conductors. In this paper we analyzed numerically (using FEM) an effect of various REBCO cables’ magnetization on the field quality of canted cosine theta (CCT) dipole magnets. The magnetic properties of the cables were taken from our measurements of their M (H) curves at 4.2 K and magnetic fields up to 12 T. Also, flux creep effects were measured and their effects on field quality analyzed. Here we present a modeling of a CCT magnet containing 1 dipole double layer wound using a CORC and STAR cable. To make the FEM modeling less computationally “expensive”, we modelled only a section of 10 turns of the magnet's central part and calculated b3 fields on a circle of 2/3 of the innermost layer center line. Special M (H) curves measured during various field cycles (the so called “pre-injection cycles”) are effective in decreasing b 3 fields of the magnets. Flux creep effects suppress the b 3 fields further. In conclusion, using these techniques b 3 fields less than 10 units can be achieved.

36 MATERIALS SCIENCE↗