Search NASA⌕ Search

SEARCH · Search NASA

Results for “Male”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Slip joint connector

A slip joint connector for joining first and second structural elements together is presented. The connector has a first body member attachable to the first structural element and a second body member attachable to the second structural element. The first body member has a male protuberance including a conical portion and the second body member has a conical receptacle for cooperatively receiving the conical portion of the protuberance. The protuberance includes a bridging portion for spacing the conical portion from the remainder of the first body member and the second body member has a well communicating with the conical receptacle for receiving the bridging portion. The conical male portion internally carries a nut while the second body member may receive a bolt through the receptacle to be threadedly received by the nut to secure the first and second body members tightly together.

Thomas, Frank P.↗

Magnetic Resonance Imaging (MRI) of skeletal muscles in astronauts after 9 days of space flight

Skylab data indicated that prolonged exposure of human subjects to microgravity environment causes significant muscle atrophy accompanied by reduced muscle strength and fatigue resistance. The objective of this study was to determine decrements in muscle size, if any, in the soleus and gastrocnemius muscles of male and female astronauts after 9 days of space flight. Methods: Eight astronauts, one female and seven male, between the ages of 31 and 59 years 59-84 kg in body weight were examined by MRI 2-3 times preflight within 16 days before launch, and 2 days, (n=6) and seven days (n=3) after landing. The right leg muscles (gastroc-soleus) were imaged with a lower extremity coil in magnets operating at 1.0 or 1.5 Tsela. The imaging protocol consisted of spin echo with a Tr of 0.70 - 1.5 sec. Thirty to forty 3-5 mm thick slices were acquired in 256 x 128 or 256 x 256 matrices. Acquisition time lasted 20-40 minutes. Multiple slices were measured by computerized planimetry. Results: Compared to the preflight, the cross-sectoral areas (CSA) of the soleus, gastrocnemius, and the leg, at 2 days after landing were reduced (at least p less than 0.05) 8.9 percent, 13.2 percent, and 9.5 percent respectively. The soleus and the leg of three astronauts evaluated at 7 days postflight did not show full recovery compared to the preflight values. Conclusions: It is concluded that l9-days of space flight may cause significant decreases in CSA of the leg muscles. The factors responsible for this loss need further determination.

Jaweed, M.↗

US experiments flown on the Soviet biosatellite Cosmos 2044. Volume 1: Mission description, experiments K-7-01 - K-7-15

Cosmos 2044 was launched on September 15, 1989, containing radiation dosimetry experiments and a biological payload including two young male rhesus monkeys, ten adult male Wistar rats, insects, amphibians, protozoa, cell cultures, worms, plants and fish. The biosatellite was launched from the Plesetsk Cosmodrome in the Soviet Union for a mission duration of 14 days, as planned. The major research objectives were: (1) Study adaptive response mechanisms of mammals during flight; (2) Study physiological mechanisms underlying vestibular, motor system and brain function in primates during early and later adaptation phases; (3) Study the tissue regeneration processes of mammals; (4) Study the development of single-celled organisms, cell cultures and embryos in microgravity; (5) Study radiation characteristics during the mission and investigate doses, fluxes and spectra of cosmic radiation for various types of shielding. American and Soviet specialists jointly conducted 29 experiments on this mission including extensive preflight and post flight studies with rhesus monkeys, and tissue processing and cell culturing post flight. Biosamples and data were subsequently transferred to the United States. The U.S. responsibilities for this flight included development of flight and ground-based hardware, the preparation of rat tissue sample procedures, the verification testing of hardware and experiment procedures, and the post flight analysis of biospecimens and data for the joint experiments. The U.S. investigations included four primate experiments, 24 rat experiments, and one radiation dosimetry experiment. Three scientists investigated tissue repair during flight for a subgroup of rats injured preflight by surgical intervention. A description of the Cosmos 2044 mission is presented in this report including preflight, on-orbit and post flight activities. The flight and ground-based bioinstrumentation which was developed by the U.S. and U.S.S.R. is also described, along with the associated preflight testing of the U.S. hardware.

Connolly, James P.↗

Solar particle dose rate buildup and distribution in critical body organs

Human body organs have varying degrees of radiosensitivity as evidenced by radioepidemiologic tables. The major critical organs for both the male and female that have been identified include the lung, thyroid, stomach, and breast (female). Using computerized anatomical models of the 50th percentile United States Air Force male and female, we present the self-shielding effects of these various body organs and how the shielding effects change as the location (dose point) in the body varies. Several major solar proton events from previous solar cycles and several events from the current 22nd solar cycle have been analyzed. The solar particle event rise time, peak intensity, and decay time vary considerably from event to event. Absorbed dose and dose equivalent rate calculations and organ risk assessment data are presented for each critical body organ. These data are compared with the current NASA astronaut dose limits as recommended by the National Council on Radiation Protection and Measurements.

Atwell, William↗

Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults With Amputations

The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.

Atkins, Diane J.↗

Using Transom Jack in the Human Engineering Analysis of the Materials Science Research Rack-1 and Quench Module Insert

This paper describes the human engineering analysis performed on the Materials Science Research Rack-1 and Quench Module Insert (MSRR-1/QMI) using Transom Jack (Jack) software. The Jack software was used to model a virtual environment consisting of the MSRR-1/QMI hardware configuration and human figures representing the 95th percentile male and 5th percentile female. The purpose of the simulation was to assess the human interfaces in the design for their ability to meet the requirements of the Pressurized Payloads Interface Requirements Document - International Space Program, Revision C (SSP 57000). Jack was used in the evaluation because of its ability to correctly model anthropometric body measurements and the physical behavior of astronauts working in microgravity, which is referred to as the neutral body posture. The Jack model allows evaluation of crewmember interaction with hardware through task simulation including but not limited to collision avoidance behaviors, hand/eye coordination, reach path planning, and automatic grasping to part contours. Specifically, this virtual simulation depicts the human figures performing the QMI installation and check-out, sample cartridge insertion and removal, and gas bottle drawer removal. These tasks were evaluated in terms of adequate clearance in reach envelopes, adequate accessibility in work envelopes, appropriate line of sight in visual envelopes, and accommodation of full size range for male and female stature maneuverability. The results of the human engineering analysis virtual simulation indicate that most of the associated requirements of SSP 57000 were met. However, some hardware design considerations and crew procedures modifications are recommended to improve accessibility, provide an adequate work envelope, reduce awkward body posture, and eliminate permanent protrusions.

Dunn, Mariea C.↗

CO2 Accumulation in the Non-Conformal Helmet of the NASA Launch and Entry Suit During Simulated Unaided Egress

The Launch and Entry Suit (LES) has been worn by astronauts since 1988 for Space Shuttle launch and landing. Previous work indicated that carbon dioxide (CO2) accumulation in the LES non-conformal helmet might be high during locomotion while wearing the LES. The purpose of this study was to characterize the inspired CO2%, metabolic requirements, and egress performance during a simulation of an unaided egress from the Space Shuttle in healthy male subjects wearing the LES and walking on a treadmill. With the helmet visor closed, 12 male subjects completed a 6-min seated prebreathe with 100% O2 followed by a 2-min stand and 5 min of walking at 1.56 m/sec (5.6 km/h, 3.5 mph) as a simulation of unaided egress. All subjects walked with four different G-suit pressures (0.0, 0.5, 1.0, 1.5 psi). After a 10-min recovery, subjects walked 5 min with the same G-suit pressure and helmet visor open for the measurement of metabolic rate (VO2). When G-suit inflation levels were 1.0 or 1.5 psi, only 4 of our 12 healthy, non-micro-gravity exposed subjects completed the unaided egress. Inspired CO2 levels greater than 4% were routinely observed during walking. The metabolic cost at the 1.5 psi G-suit inflation was over 135% of the metabolic cost at 0.0 psi inflation. During unaided egress, G-suit inflation pressures of 1.0 (required inflation for missions greater than 11 days) and 1.5 psi resulted in elevated CO2 in the LES helmet and increased metabolic cost of walking, either of which could impact unaided egress by returning space flight crews.

Greenisen, M. C.↗

Statistical Analysis of Risk Factors in the Prebreathe Reduction Protocol

The 165 exposures from four 2-hour protocols were analyzed for correlations or trends between decompression sickness (DCS) or venous gas emboli (VGE), and variables that affect risk in the subject and astronaut populations. The assumption in this global survey is that the distributions of gender, age, body mass index, etc., are equally represented in all four tested procedures. We used Student t-test for comparisons between means and chi-square test between comparisons of proportions with p<0.05 defining a significant level. The type and distribution of the 19 cases of DCS were similar to historical cases. There was no correlation of age, gender, body mass index or fitness level with greater incidence of DCS or VGE. However increased age was associated with more Grade IV VGE in males. The duration and quantity of exercise during prebreathe is inversely related to risk of DCS and VGE. The latency time for VGE was longer (103 min +/- 56 SD, n = 15) when the ergometry was done approximately 15 min into the prebreathe than when done at the start of the prebreathe (53 min +/- 31, n = 13). The order of the ergometry did not influence the overall DCS and VGE incidence. We identified variables other than those of the prebreathe procedures that influence the DCS and VGE outcome. The analysis suggests that males over 40 years have a high incidence of Grade IV VGE.

Gerth, Wayne A.↗

Development of a Reference Dose for Perchlorate: Current Issues and Status

The perchlorate anion (ClO4) is typically manufactured as the ammonium salt. The most common use of ammonium perchlorate is in the aerospace program as a component of solid rocket fuel. The perchlorate anion is exceedingly stable under environmental conditions and has been found in ground and surface waters in CA, NV, UT, AZ, TX, AK, NY, MD, WV and FL. The National Center for Environmental Assessment (NCEA) of the U.S. Environmental Protection Agency (US EPA) is in the process of developing an oral reference dose (RfD) for perchlorate. An oral RfD is a body-weight-adjusted dose that can be consumed daily over an entire lifetime with the expectation of no adverse health effects. Once developed, the new RfD will be used by US EPA as the basis of a safe-drinking-water level (SDWL) guideline. US EPA and regional regulatory agencies will then jointly or separately propose clean-up action levels for ground and surface waters at contaminated sites. The toxicological database on CIO4- as of March 1997 was determined by an expert peer-review panel to be inadequate for the purpose of deriving an oral RfD. For example, little or no experimental data existed on the subchronic, reproductive, or developmental toxicity of perchlorate. To fill gaps in the toxicological database, eight animal studies were designed by a government-industry consortium that included US EPA and AFRL. These studies were performed in 1997-1998. It has been known for many years that in the thyroid, high doses of perchlorate block the function of iodide by competing for iodide binding sites. Perchlorate was used in the 1950s-60s as a treatment for Graves' disease (a hyperthyroid condition). Because of what was already known about the pharmacological mode of action of perchlorate, specific concerns addressed in the design of the recent animal studies included the potential for developmental toxicity, notably neurological development. Upon review of complete study reports from four of the studies and incomplete data from the other two, US EPA/NCEA issued a document in December 1998 stating that the critical effects were hormone and histology data from the neurodevelopmental/behavioral toxicity study that had been performed in rats; an RfD was proposed based upon the observation of thyroid-follicular-cell hypertrophy in the 5-day-old pups (PND) of dams given perchlorate in drinking water at 0.1 mg/kg-day (the lowest dose tested) in this study. US EPA/NCEA also focused attention on a nonsignificant increase in motor activity observed in 14-day-old male pups in the same study at the same dose. In February 1999, a public workshop was convened at which an external peer-review panel determined that there was still insufficient data to support the development of a RfD. Additional studies were recommended. Since that time a clinical study revealed significant depression of thyroidal uptake of iodide in volunteers receiving potassium perchlorate at 10 mg/day for 14 days. Follow-up studies currently underway include a pathology working-group review of histology slides from the all of the previous studies, a motor activity study similar to the first behavioral study, an additional immunotoxicity study, male and female rat kinetic studies, a hormone interlaboratory study, and an effects study for thyroid and brain in developing rats. These studies are expected to be complete by mid-2000. A clinical study is planned to determine inhibition of iodide uptake and kinetic parameters in humans following 14-day perchlorate ingestion. The kinetics studies will provide data for developing physiologically based pharmacokinetic (PBPK) models for rats and humans needed to establish the RfD.

Pleus, R. C.↗

Physiologic Responses Produced by Active and Passive Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

Ku, Yu-Tsuan E.↗

The Role of Nutrition in the Changes in Bone and Calcium Metabolism During Space Flight

On Earth, the primary purpose of the skeleton is provide structural support for the body. In space, the support function of the skeleton is reduced since, without gravity, structures have only mass and no weight. The adaptation to space flight is manifested by shifts in mineral distribution, altered bone turnover, and regional mineral deficits in weight-bearing bones. The shifts in mineral distribution appear to be related to the cephalic fluid shift. The redistribution of mineral from one bone to another or to and from areas in the same bone in response to alterations in gravitational loads is more likely to affect skeletal function than quantitative whole body losses and gains. The changes in bone turnover appear dependent upon changes in body weight with weight loss tending to increase bone resorption as well as decrease bone formation. During bedrest, the bone response to unloading varies depending upon the routine activity level of the subjects with more active subjects showing a greater suppression of bone formation in the iliac crest with inactivity. Changes in body composition during space flight are predicted by bedrest studies on Earth which show loss of lean body mass and increase tn body fat in adult males after one month. In ambulatory studies on Earth, exercising adult males of the same age, height, g weight, body mass index, and shoe size show significantly higher whole body mineral and lean body mass. than non-exercising subjects. Nutritional preference appears to change with activity level. Diet histories in exercisers and nonexercisers who maintain identical body weights show no differences in nutrients except for slightly higher carbohydrate intake in the exercisers. The absence of differences in dietary calcium in men with higher total body calcium is noteworthy. In this situation, the increased bone mineral content was facilitated by the calcium endocrine system. This regulatory system can be by-passed by raising dietary calcium. Increased calcium intake can increase the calcium content in normally loaded bone. However, bone with a higher calcium content still decreases proportionally to normal bone during unloading. Nutritional requirements in space should be reevaluated with respect to these adaptive changes to loading and physical activity.

Morey-Holton, Emily R.↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗

National Survey Results: Retention of Women in Collegiate Aviation

Since the numbers of women pursuing technical careers in aviation continues to remain very low, a study on retention of women was undertaken by a team of university faculty from Embry Riddle Aeronautical University, Arizona State University, and Kent State University. The study was initiated to discover the factors that influence women once they have already selected an aviation career and to ascertain what could be done to support those women who have demonstrated a serious interest in an aviation career by enrolling in a collegiate aviation program. This paper reports preliminary results of data collected in the first and second years of the study. The data was collected from surveys of 390 college students (195 women and 195 men) majoring in aviation programs in nine colleges and universities, representing widely varied geographic areas and including both two- and four-year institutions. Results revealed significant areas of concern among women in pilot training. When queried about these concerns, differences were evident in the responses of the male and female groups. These differences were expected. However, a surprising finding was that women in early stages of pilot training responded differently from women in more experienced stages, These response differences did not occur among the men surveyed. The results, therefore, suggest that women in experienced stages of training may have gone through an adaptation process and reflect more male-like attitudes about a number of objects, including social issues, confidence, family, and career.

Turney, Mary Ann↗

Analysis of the Spaceflight Effects on Growth and Development of Super Dwarf Wheat Grown on the Space Station Mir

The hypothesis being tested is that Super Dwarf wheat, Triticum aestivum L., plants in the Svet Greenhouse onboard the Russian Space Station Mir will complete a life cycle in spaceflight, providing that the environmental conditions necessary for adequate growth on Earth are supplied. Twenty six seeds of wheat were planted in each of 2 rows of 2 root compartments for a total of 104 seeds in Svet. Germination rate at 7 d was 56 and 73% on Mir and 75 and 90% in ground-based controls. Plants were grown throughout the whole cycle of ontogenesis (123 d) with samples gathered at different times to validate the morphological and reproductive stages of the plants. Young plants showed vigorous early seedling growth, with large biomass production, including the formation of 280 floral spikes. Upon return to Earth, comparative analyses showed that the number of tillers and flowers per spikelet were 63.2% and 40% greater, respectively, in Mir-grown plants than in the controls. By contrast, the stem length (52.4%), spike mass (49.2%) and length (23.1%), awn length (75.7%), number of spikelets per spike (42.8%) and number of seeds per spike (100% sterile) from Mir-grown plants were substantially less than the controls. Distribution of moisture and roots throughout the substrate was very good. All florets on Mir-grown spikes ceased development at the same stage of ontogeny. Lack of caryopses formation was attributed to male sterility occurring at different stages of staminal development. Anthers failed to dehisce and pollen grains were smaller and shriveled compared to the controls, suggesting a chronic stress had occurred in the Svet growth chamber. Recent ground-based studies indicated that ethylene, which was measured at 0.3 to 1.8 mg per kilogram in the Mir, almost certainly could have induced male sterility in the wheat plants grown on the Mir.

Levinskikh, M. A.↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

SHARP {Summer High School Apprenticeship Research Program}

The Year 2002 was another successful year for SHARP. Even after 22 years of SHARP, the Program continues to grow. There were 12 NASA Field Installations with a total of 210 apprentices who participated in the summer 2002 Program supported by 215 mentors in the fields of science and engineering. The apprentices were chosen from a pool of 1,379 applicants. This was a record year for applications exceeding the previous year by over 60%. For the second consecutive year, the number of female participants exceeded the number of males with 53% female and 47% male participants in the program. The main thrust of our recruiting efforts is still focused on underrepresented populations; especially African American, Hispanic, and Native American. At the conclusion of the summer program, most SHARP Apprentices indicated on the EDCATS that they would be interested in pursuing careers in Aerospace (56.2%) while the second largest career choice was a job at NASA (45.7%). The smallest number (11.9%) were interested in careers in the government. The table of responses is listed in the Appendix. Once again this year we were fortunate in that the SHARP COTR, Ms. Deborah Glasco, gained the support of MURED funding sources at NASA to fully fund additional apprentices and boost the number of apprentices to 210.

Glasco, Deborah↗

Use of a Slick-Plate as a Contingency Exercise Surface for the Treadmill With Vibration Isolation System

The treadmill with vibration isolation system (TVIS) was developed to counteract cardiovascular, musculoskeletal, and neurovestibular deconditioning during long-duration missions to the International Space Station (ISS). However, recent hardware failures have necessitated the development of a short-term, temporary contingency exercise countermeasure for TVIS until nominal operations could be restored. The purpose of our evaluation was twofold: 1) to examine whether a slick-plate/contingency exercise surface (CES) could be used as a walking/running surface and could elicit a heart rate (HR) greater than or equal to 70% HR maximum and 2) to determine the optimal hardware configuration, in microgravity, to simulate running/walking in a 1-g environment. One subject (male) participated in the slick surface evaluation and two subjects (one male, one female) participated in the microgravity evaluation of the slick surface configuration. During the slick surface evaluation, the subject was suspended in a parachute harness and bungee cord configuration to offset the subject's body weight. Using another bungee cord configuration, we added a vertical load back to the subject, who was then asked to run for 20 minutes on the slick surface. The microgravity evaluation simulated the ISS TVIS, and we evaluated two different slick surfaces (Teflon surface and an aluminum surface coated with Tufram) for use as a CES. We evaluated each surface with the subject walking and running, with and without a handrail, and while wearing either socks or nylon booties over shoes. In the slick surface evaluation, the subject ran for 20 minutes and reached a maximum HR of 170 bpm. In the microgravity evaluation, the subjects chose the aluminum plate coated with Tufram as the CES, while wearing a pair of nylon booties over running shoes and using a handrail, as the optimal hardware configuration. The results indicate that the CES may provide an interim capability to counteract aerobic deconditioning until TVIS can be returned to an operational status. No indices of musculoskeletal or neurovestibular deconditioning were evaluated. Future studies are needed to validate the efficacy of CES in countering aerobic deconditioning and the effects, if any, on musculoskeletal and neurovestibular deconditioning.

James A. Loehr↗

Effects of Hindlimb Unweighting on Arterial Contractile Responses in Mice

The aim of this work was to determine if hindlimb unweighting in mice alters arterial contractile responses. Sixteen male C57B/6 mice and 16 male Chinese Kunming mice were divided into control and 3 weeks hindlimb unweighting groups, respectively. Using isolated arterial rings from different arteries of mouse, effects of 3 weeks hindlimb unweighting on arterial contractile responsiveness were examined in vitro. The results showed that, in arterial rings from both C57B/6 and Chinese Kunming mice, maximum isometric contractile tensions evoked by either KCl or phenylephrine were significantly lower in abdominal aortic, mesenteric arterial and femoral arterial rings from hindlimb unweighting, compared to control mice. However, the maximal contractile responses of common carotid rings to KCl and PE were not significantly different between control and hindlimb unweighting groups. The sensitivity (EC(sub 50)) of all arteries to KCl or PE showed no significant differences between control and hindlimb unweighting mice. These data indicated that 3 weeks hindlimb unweighting results in a reduced capacity of the arterial smooth muscle of the hindquarter to develop tension. In addition, the alterations in arterial contractile responses caused by hindlimb unweighting in mice are similar as those in rats. Our work suggested that hindlimb unweighting mouse model may be used as a model for the study of postflight cardiovascular deconditioning.

Ma, Jia↗