Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

error analysis↗

Observations of plasma dynamics in the coma of P/Halley by the Giotto Ion Mass Spectrometer

Observations in the coma of P/Halley by the Giotto Ion Mass Spectrometer (IMS) are reported. The High Energy Range Spectrometer (HERS) of the IMS obtained measurements of protons and alpha particles from the far upstream region to the near ionopause region and of ions from mass 12 to 32 at distances of about 250,000 to 40,000 km from the nucleus. Plasma parameters from the High Intensity Spectrometer (HIS) of the IMS obtained between 150,000 to 5000 km from the nucleus are also discussed. The distribution functions of water group ions (water group will be used to refer to ions of 16 to 18 m/q, where m is in AMU and q is in unit charges) are observed to be spherically symmetric in velocity space, indicating strong pitch angle scattering. The discontinuity known as the magnetic pile-up boundary (MPB) is apparent only in proton, alpha, and magnetometer data, indicating that it is a tangential discontinuity of solar wind origin. HERS observations show no significant change in the properties of the heavy ions across the MPB. A comparison of the observations to an MHD model is made. The plasma flow directions at all distances greater than 30,000 km from the nucleus are in agreement with MHD calculations. However, despite the agreement in flow direction, within 200,000 km of the nucleus the magnitude of the velocity is lower than predicted by the MHD model and the density is much larger (a factor of 4). Within 30,000 km of the nucleus there are large theoretical differences between the MHD model flow calculations for the plane containing the magnetic field and for the plane perpendicular to the magnetic field. The observations agreed much better with the pattern calculated for the plane perpendicular to the magnetic field. The data obtained by the High Energy Range Spectrometer (HERS) of the IMS that are published herein were provided to the International Halley Watch archive.

Goldstein, B. E.↗

Mass spectrometer measurements of test gas composition in a shock tunnel

Shock tunnels afford a means of generating hypersonic flow at high stagnation enthalpies, but they have the disadvantage that thermochemical effects make the composition of the test flow different to that of ambient air. The composition can be predicted by numerical calculations of the nozzle flow expansion, using simplified thermochemical models and, in the absence of experimental measurements, it has been necessary to accept the results given by these calculations. This note reports measurements of test gas composition, at stagnation enthalpies up to 12.5 MJ.kg(exp -1), taken with a time-of-flight mass spectrometer. Limited results have been obtained in previous measurements. These were taken at higher stagnation enthalpies, and used a quadruple mass spectrometer. The time-of-flight method was preferred here because it enabled a number of complete mass spectra to be obtained in each test, and because it gives good mass resolution over the range of interest with air (up to 50 a.m.a.).

Skinner, K. A.↗

A field-ionization neutral-particle mass spectrometer

Description of laboratory model of a neutral-particle mass spectrometer that could make localized direct measurements of the neutral densities at 1 AU. Using a magnet that has a circular pole face 2.54 cm in diameter and a gap flux density of 8.0 kG, the following sensitivities were obtained for the various species: 10 to the 10th power counts per second per Torr for H2, 3 times 10 to the eighth power counts per second per Torr for He, and 2 times 10 to the 9th power counts per second per Torr for N2. Overall sensitivity may be increased through the use of electrostatic focusing elements between the ion source and the magnetic analyzer.

Curtis, C. C.↗

Hot ions observed by the Giotto ion mass spectrometer inside the Comet Halley contact surface

Just inside the contact surface (approx. 4700 km) the High Energy Range Spectrometer (HERS) sensor of the Giotto ion mass spectrometer detected a sudden, intense burst of ions that lasted until the HERS sensor ceased transmitting data at a distance 3000 km from comet Halley. During this interval ions with M/Q=1, 2, 12, 14, 16, 19, 24 and 28 were observed. The heavier ions appear in two populations (in the S/C frame): a very low energy, almost omnidirectional distribution, and a more energetic (approx. < ram speed) population coming from the ram direction. The low energy ions may belong to the natural Halley environment or be generated at the spacecraft by dust and gas bombardment. The ions may also be related to spacecraft charging processes on Giotto.

Goldstein, R.↗

Mass spectrometer for measurements of relative ion concentrations in plasmas

A mass spectrometer which can be used to measure relative ion concentrations in a multiion component plasma has been designed for use in a strong (1-4-kG) uniform magnetic field. The spectrometer features an acceleration region which accelerates thermal ions through a series of three tantalum electrodes at a 30 deg angle to the B field, and a collection region in which ions are selectively collected, depending on the size of their gyroradii, by a cylindrical collector. Relative ion concentrations are determined from measurements of the collector current as a function of accelerating voltage. Results obtained using this instrument in a Q-machine device operated with a two-ion (Cs+/K+) component plasma are presented.

Suszcynsky, David M.↗

Aseptic Handling of the MOMA Mass Spectrometer After Dry Heat Microbial Reduction

Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS) is an instrument in the larger MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. As a life-detection instrument on a Mars landing mission, MOMA-MS has very stringent Planetary Protection (PP) bioburden requirements. Within the MOMA instrument suite, the hardware surfaces of the sample path must be cleaned to a level of 0.03 spore/sq m. To meet this requirement, a process called Dry Heat Microbial Reduction (DHMR) is used to decrease the number of viable spores by 4 orders of magnitude. Before DHMR, the hardware is handled using standard cleanroom practices, while after DHMR, all sample path surfaces must be handled aseptically when exposed. Aseptic handling of the sample path involves a number of strategies and protocols including working only in an aseptic ISO class 5 work space, limiting the amount of time of exposure, using sterile garmenting with sterile gloves, and using sterile tools. Before work begins, the aseptic workspace will be tested for bioburden and particle fallout, and all tools that will contact sample path surfaces must be sterilized. During the exposure activity, sterile garments will be worn, sterile tools will be handled in a 2 person set up so that the operator touches only the sterile tool and not the exterior surfaces of the sterile pouch, and the environment will be monitored with active and passive fallout for bioburden and particle levels. Any breach in the planetary protection cleanliness can necessitate repeating DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.

Life Detection↗

Analysis of the Pioneer Venus Large Probe Neutral Mass Spectrometer Data Yields New Insights into the Composition of Venus’ Atmosphere

We present a new analysis of mass spectral data obtained by the Pioneer Venus (PV) Large Probe Neutral Mass Spectrometer (LNMS). To analyze the LNMS data, we constructed an analytical model that accounts for spectrometer performance at each altitude, provides CO2 abundances in units of density (kg/m3), and retains the resolving power of the LNMS through use of a targeted data-fitting routine. Our results provide new insights into the composition of Venus’ atmosphere and show that densities for CO2 increase towards the surface, which is suggestive of surface outgassing. Additionally, the data reveal partial obstructions of the LNMS inlet at <17 km, which is an likely important consideration for future missions. Re-analysis of the LNMS data may assist in revealing the past, present and/or future habitability of Venus’ clouds.

mass spectral data↗

Neutral Mass Spectrometer (NMS) for the Lunar Atmosphere and Dust Environment Explorer (LADEE) Mission

The Lunar Atmosphere and Dust Environment Explorer (LADEE) mission currently scheduled for launch in early 2013 aboard a Minotaur V will orbit the moon at a nominal periselene of 50 km to characterized the lunar atmosphere and dust environment. The science instrument payload includes a neutral mass spectrometer as well as an ultraviolet spectrometer and a dust detector. Although to date only He, Ar-40, K, Na and Rn-222 have been firmly identified in the lunar exosphere and arise from the solar wind (He), the lunar regolith (K and Na) and the lunar interior (Ar-40, Rn-222), upper limits have been set for a large number of other species, LADEE Neutral Mass Spectrometer (NMS) observations will determine the abundance of several species and substantially lower the present upper limits for many others. Additionally, LADEE NMS will observe the spatial distribution and temporal variability of species which condense at nighttime and show peak concentrations at the dawn terminator (e,g, Ar-40), possible episodic release from the lunar interior, and the results of sputtering or desorption processes from the regolith. In this presentation, we describe the LADEE NMS hardware and the anticipated science results.

Collier, Michael R.↗