Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mass spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The Retarding Ion Mass Spectrometer on Dynamics Explorer-A

The thermal component of the magnetospheric plasma plays a key role in magnetosphere-ionosphere coupling processes, acting as a strong influence on ionospheric structure at low altitudes and as a source and modifier of the hotter plasma population at high altitudes. The Retarding Ion Mass Spectrometer (RIMS) instrument on Dynamics Explorer-A is designed to measure this important thermal plasma component. Using a combination of retarding potential analysis and magnetic ion mass spectrometer techniques, the RIMS instrument will measure the bulk plasma parameters of ion density (0.1 to 1,000,000 ions/cu cm), temperature (0-45 eV), and bulk flow (greater than 0.5 km/sec) in the inner plasmasphere and ionosphere, and the specific ion pitch angle and energy spectral characteristics in the outer plasmasphere and plasma trough for a mass range of 1-32 amu. The energy and mass spectral step sequences, as well as the multiplexing of the resultant data, can be tailored to accomplish a variety of thermal ion measurements throughout the inner magnetosphere.

Chappell, C. R.↗

High sensitivity pulse-counting mass spectrometer system for noble gas analysis

A pulse-counting mass spectrometer is described which is comprised of a new ion source of cylindrical geometry, with exceptional optical properties (the Baur source), a dual focal plane externally adjustable collector slits, and a 17-stage Allen-type electron multiplier, all housed in a metal 21 cm radius, 90 deg magnetic sector flight tube. Mass discrimination of the instrument is less than 1 per mil per mass unit; the optical transmission is more than 90%; the source sensitivity (Faraday collection) is 4 ma/torr at 250 micron emission; and the abundance sensitivity is 30,000.

Hohenberg, C. M.↗

Gas densities near 230 km from orbital drag and mass spectrometer measurements - A comparison

Perigee density data near 230 km for the Aeros satellite are analyzed for more than 1000 orbits. A comparison method for such data was developed which is based on the observed rate of change of orbital period as compared with the orbital decay computed from mass-spectrometer data obtained at discrete positions along the orbit. In general, the method confirms the good agreement of the average ratio of in-situ and orbit-drag-inferred perigee densities. In the case of Aeros, absolute densities measured by the NATE mass spectrometer are confirmed.

Roemar, M.↗

Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

error analysis↗

Observations of plasma dynamics in the coma of P/Halley by the Giotto Ion Mass Spectrometer

Observations in the coma of P/Halley by the Giotto Ion Mass Spectrometer (IMS) are reported. The High Energy Range Spectrometer (HERS) of the IMS obtained measurements of protons and alpha particles from the far upstream region to the near ionopause region and of ions from mass 12 to 32 at distances of about 250,000 to 40,000 km from the nucleus. Plasma parameters from the High Intensity Spectrometer (HIS) of the IMS obtained between 150,000 to 5000 km from the nucleus are also discussed. The distribution functions of water group ions (water group will be used to refer to ions of 16 to 18 m/q, where m is in AMU and q is in unit charges) are observed to be spherically symmetric in velocity space, indicating strong pitch angle scattering. The discontinuity known as the magnetic pile-up boundary (MPB) is apparent only in proton, alpha, and magnetometer data, indicating that it is a tangential discontinuity of solar wind origin. HERS observations show no significant change in the properties of the heavy ions across the MPB. A comparison of the observations to an MHD model is made. The plasma flow directions at all distances greater than 30,000 km from the nucleus are in agreement with MHD calculations. However, despite the agreement in flow direction, within 200,000 km of the nucleus the magnitude of the velocity is lower than predicted by the MHD model and the density is much larger (a factor of 4). Within 30,000 km of the nucleus there are large theoretical differences between the MHD model flow calculations for the plane containing the magnetic field and for the plane perpendicular to the magnetic field. The observations agreed much better with the pattern calculated for the plane perpendicular to the magnetic field. The data obtained by the High Energy Range Spectrometer (HERS) of the IMS that are published herein were provided to the International Halley Watch archive.

Goldstein, B. E.↗

Analytical Assessment of Impurities Found in Process Gases using the InfiTOF, a High Resolution, Low Mass, Variable Time-of-Flight Mass Spectrometer

The JEOL InfiToF is a high-resolution, low mass (HRLM) mass spectrometer (MS) with the application potential to meet analytical needs for tritium handling systems, such as those at the Savannah River Tritium Facilities (SRTE) and those used in fusion research. The Service Level Agreement (SLA) #144 line 27 “InfiTOF R&D” has concluded its first year of efforts under Tritium Recycle and Renewal. The project goals for FY22 were: (1) Production of a finalized modification list for tritium hardened components in the InfiTOF, (2) perform an assessment on impurity gases commonly found in process gases from Tritium Facilities and (3) begin developing a set of standardized work instructions that will be used as a basis for operations on the InfiTOF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mass spectrometer measurements of test gas composition in a shock tunnel

Shock tunnels afford a means of generating hypersonic flow at high stagnation enthalpies, but they have the disadvantage that thermochemical effects make the composition of the test flow different to that of ambient air. The composition can be predicted by numerical calculations of the nozzle flow expansion, using simplified thermochemical models and, in the absence of experimental measurements, it has been necessary to accept the results given by these calculations. This note reports measurements of test gas composition, at stagnation enthalpies up to 12.5 MJ.kg(exp -1), taken with a time-of-flight mass spectrometer. Limited results have been obtained in previous measurements. These were taken at higher stagnation enthalpies, and used a quadruple mass spectrometer. The time-of-flight method was preferred here because it enabled a number of complete mass spectra to be obtained in each test, and because it gives good mass resolution over the range of interest with air (up to 50 a.m.a.).

Skinner, K. A.↗

A field-ionization neutral-particle mass spectrometer

Description of laboratory model of a neutral-particle mass spectrometer that could make localized direct measurements of the neutral densities at 1 AU. Using a magnet that has a circular pole face 2.54 cm in diameter and a gap flux density of 8.0 kG, the following sensitivities were obtained for the various species: 10 to the 10th power counts per second per Torr for H2, 3 times 10 to the eighth power counts per second per Torr for He, and 2 times 10 to the 9th power counts per second per Torr for N2. Overall sensitivity may be increased through the use of electrostatic focusing elements between the ion source and the magnetic analyzer.

Curtis, C. C.↗

Hot ions observed by the Giotto ion mass spectrometer inside the Comet Halley contact surface

Just inside the contact surface (approx. 4700 km) the High Energy Range Spectrometer (HERS) sensor of the Giotto ion mass spectrometer detected a sudden, intense burst of ions that lasted until the HERS sensor ceased transmitting data at a distance 3000 km from comet Halley. During this interval ions with M/Q=1, 2, 12, 14, 16, 19, 24 and 28 were observed. The heavier ions appear in two populations (in the S/C frame): a very low energy, almost omnidirectional distribution, and a more energetic (approx. < ram speed) population coming from the ram direction. The low energy ions may belong to the natural Halley environment or be generated at the spacecraft by dust and gas bombardment. The ions may also be related to spacecraft charging processes on Giotto.

Goldstein, R.↗