Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Deuterated Xylene-Based Neutron Spectrometry

Deuterated scintillators, such as deuterated xylene (C8D10) have been theorized to offer better pulse shape discrimination (PSD) and neutron spectrometry performance than traditional protiated scintillators due to the anisotropy of neutron scattering on deuterium. However, the light output responses of said deuterated scintillators to monoenergetic has not been characterized in its entirety at both high and low energies. Several time-of-flight experiments were conducted at the Idaho national Laboratory to characterize a pair of EJ-301D deuterated xylene detectors. The low energy detector response to quasi-monoenergetic neutrons was measured using a Cf-252 source, and the high energy detector response was measured using a D-T source and angles of 20, 45, and 60 deg, corresponding to theoretical neutron energies of 13.2, 10.4, and 8.2 MeV. During post-processing, the neutron and gamma bands were clearly able to be separated, even at low light outputs, solidifying the superior PSD capability of deuterated xylene. An exponential of fit of LO=0.63E-2.22*(1-exp(-0.25E)), which has good agreement with previously measured data, was found as the light output response from deuteron recoils. Additionally, measurements of AmBe, D-T, and D-D sources were unfolded using the light output response curve, which resulted in favorable agreement with theoretical values. Further testing of the response matrix by unfolding more sources (such as PuBe) needs to be done, but the unfolding accuracy for currently available sources suggests that deuterated xylene can be used to measure and unfold both fission, monoenergetic, and continuous spectra.

scintillator↗

Chasing the multi-modal plasma response in MAST-U

Abstract Achieving edge localized modes (ELMs) suppression in spherical tokamaks by applying resonant magnetic perturbations (RMPs) has proven challenging. The poloidal spectrum of the applied RMP is a key parameter that has an impact on the capability to mitigate and eventually suppress ELMs. In this work the resistive magnetohydrodynamic code MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) is used to evaluate the possibility of directly measuring the plasma response in MAST-U, and particularly its variation as function of the applied poloidal spectrum, in order to guide the experimental validation of the predicted best RMP configuration for ELM suppression. Toroidal mode number n = 2 RMP is considered to minimize the presence of sidebands, and to avoid the deleterious core coupling of n = 1. Singular Value Decomposition is used to highlight linearly independent structures in the simulated magnetic 3D fields and how those structures can be measured at the wall where the magnetic sensors are located. Alternative ways to measure the multimodal plasma response and how they can be used to infer the best RMP configuration to achieve ELM suppression are also presented, including the plasma displacement and the 3D footprints at the divertor plates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subsurface Characteristics of Metal-Halide Perovskites Polished by an Argon Ion Beam

Focused ion beam (FIB) techniques have been frequently used to section metal-halide perovskites for microstructural investigations. However, the ion beams directly irradiating the sample surface may alter its properties far different from those of pristine, potentially leading to modified deterioration mechanisms under aging stressors. Here, we combine complementary approaches to measure the subsurface characteristics of polished perovskites and identify the chemical species responsible for the measured properties. Analysis of the experimental results in conjunction with Monte Carlo simulations indicates that atomic displacements and local heating occur in the first ≈15 nm of the subsurface of methylammonium lead iodide (MAPbI 3 ) by glancing-angle Ar + beam irradiation (4 kV at 3°). The lead-rich, iodine-deficient surface promotes rapid phase segregation under thermal aging conditions. On the other hand, despite the subsurface modification, our experiments confirm that the rest of the MAPbI 3 bulk retains the material integrity. Our observation supports that polished perovskites could serve in studying the properties of bulk or buried junctions far away from the altered subsurface with care.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) – Performance Characterization

Design and performance of a digital signal processing platform for enhancing off-the-shelf voltage and current sensors are presented. The platform was developed for enabling advanced distribution grid applications with existing low-cost sensors. This digital sensor system leverages a variety of off-the-shelf voltage and current sensing technologies, analog-to-digital conversion, and sensor correction algorithms to yield more accurate and reliable digital measurements that support a multitude of applications and use cases. Sample performance and accuracy results are provided, including measurements at power frequency and higher harmonics. The system extends the native performance of the medium voltage sensors used in the system, for example, broadening measurement bandwidth beyond a few kHz, appropriate for measuring switching surges and harmonics on medium voltage distribution systems. The digital sensor system is installed and characterized in the field with a high-bandwidth optical calibration system to determine site-dependent calibration and performance issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the Fault Ride-Through Response of a Generic EMT Inverter Model by Laboratory Testing

This paper presents the validation of the fault ride-through response of a large-scale inverter model using laboratory testing of a commercial inverter. First, we present the generic inverter model specifications. The generic inverter control is developed based on the fault ride-through response performance requirements of IEEE Std 2800-2022 for inverter-based resources. Next, we present laboratory tests that emulate voltages at the inverter terminal resulting from balanced and unbalanced faults on the transmission system. The tests are performed on a commercia12.2 MVA battery storage inverter at the U.S. National Renewable Energy Laboratory. Comparisons of the model's response to the laboratory measurements show the generic model presented can predict the controlled response of the commercial equipment. The differences between the model's response and the laboratory measurements during the initial transient at fault inception are discussed.

fault ride-through↗

Strong Correspondence in Evapotranspiration and Carbon Dioxide Fluxes Between Different Eddy Covariance Systems Enables Quantification of Landscape Heterogeneity in Dryland Fluxes

Abstract The eddy covariance method is widely used to investigate fluxes of energy, water, and carbon dioxide at landscape scales, providing important information on how ecological systems function. Flux measurements quantify ecosystem responses to environmental perturbations and management strategies, including nature‐based climate‐change mitigation measures. However, due to the high cost of conventional instrumentation, most eddy covariance studies employ a single system, limiting spatial representation to the flux footprint. Insufficient replication may be limiting our understanding of ecosystem behavior. To address this limitation, we deployed eight lower‐cost eddy covariance systems in two clusters around two conventional eddy covariance systems in the Chihuahuan Desert of North America for a period of 2 years. These dryland settings characterized by large temperature variations and relatively low carbon dioxide fluxes represented a challenging setting for eddy covariance. We found very good closure of energy and water balance across all systems (within ±9% of unity). We found very good correspondence between the lower‐cost and conventional systems' fluxes of sensible heat (with concordance correlation coefficient (CCC) of ≥0.87), latent energy (evapotranspiration; CCC ≥ 0.89), and useful correspondence in the net ecosystem exchange ((NEE); with CCC ≥ 0.4) at the daily temporal resolution. Relative to the conventional systems, the low‐frequency systems were characterized by a higher level of random error, particularly in the NEE fluxes. Lower‐cost systems can enable wider deployment affording better replication and sampling of spatiotemporal variability at the expense of greater measurement noise that might be limiting for certain applications. Replicated eddy covariance observations may be useful when addressing gaps in the existing monitoring of critical and underrepresented ecosystems and for measuring areas larger than a single flux footprint.

54 ENVIRONMENTAL SCIENCES↗

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING↗

Development of real-time density feedback control on MAST-U in L-mode

In this paper we report on the development and demonstration of density feedback control for MAST-U. Sinusoidal perturbations are used to measure the frequency response from a deuterium gas valve (actuator) to line-integrated core electron density measured by the interferometer (sensor). In the frequency range relevant for control design, only two system-identification experiments were needed to regress a first-order dynamic model. This control-oriented model informs the offline design of a proportional integral controller with the established loop-shaping controller design method. After offline verification of the controller implementation, control is demonstrated by experimentally tracking a staircase reference for the line-integrated electron density. This paper demonstrates the efficiency of controller design using system-identification and loop-shaping, providing reliable density control for MAST-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Connecting ambient toxicity testing with community-level responses of benthic macroinvertebrates in an impacted stream in East Tennessee, USA

Single-species laboratory toxicity tests are a standard tool for evaluating potential impairment of freshwater systems; however, it remains uncertain how well they reflect community-level impacts in natural environments. This study presents a multi-decadal dataset (2005-2025) pairing ambient toxicity testing with macroinvertebrate surveys along Bear Creek on the Oak Ridge Reservation (Tennessee, USA) downstream of an industrial complex to assess the ability of laboratory tests using stream water to track community-level effects. Biannual three-brood Ceriodaphnia dubia tests from 2005 to 2025 often showed reduced reproduction at select sites. Integrating water quality data showed strong positive correlations between sublethal toxicity and specific conductance. Macroinvertebrate diversity metrics, family-level occurrence, and densities were also associated with conductance and contemporaneous C. dubia responses. Laboratory-measured sublethal toxicity was a stronger indicator of macroinvertebrate change than conductance alone, although responses varied among sites and seasons. At the site with the highest diversity, densities and richness of Ephemeroptera, Plecoptera, Trichoptera (EPT) and non-EPT taxa were significantly related to C. dubia reproduction, with greater toxicity corresponding to lower diversity. At the family level, some pollution-tolerant taxa were more prevalent and at higher densities during periods of sublethal toxicity, while some sensitive families were absent or reduced. These patterns may reflect site-specific mixtures of acute and chronic stressors, with laboratory toxicity tests more effectively capturing short-term impacts. Overall, these multi-decadal observations suggest that laboratory toxicity tests can help track water-quality changes linked to shifts in aquatic community diversity, despite variable responses reflecting the complexity of dynamic stressors in this impacted freshwater system.

Stevenson, Louise [ORNL] (ORCID:0000000349679897)↗

Impedance-Based Prediction of SSR-Generated Harmonics in Doubly-Fed Induction Generators

Doubly-fed induction generators (DFIGs) are prone to subsynchronous resonance (SSR) with series-compensated transmission lines and experiencing SSR-generated harmonics of wide-ranging magnitudes. This paper presents a large-signal impedance-based approach for the prediction of the magnitude of SSR-generated harmonics in DFIGs. Note that the large-signal impedance of a network shows variation in its impedance response with the magnitude of perturbation at its terminals. It is discovered in this paper that the impedance of a series-compen- sated transmission line starts changing with the magnitude of SSR because of the metal-oxide varistor-based protection of series capacitors in the line. The changing line impedance halts the growth of the SSR beyond a certain point, where the DFIG forms a limit-cycle mode and emits harmonics at the SSR frequency. The discovered role of the protection of series capacitors in SSR not only enables the prediction of SSR-generated harmonics but also can be used for the timely detection of an SSR event to avoid system disruption and sudden loss of bulk generation. The large- signal impedance-based prediction of SSR-generated harmonics in DFIG-based wind and hydro generators is demonstrated using numerical simulations of a 2.5-MVA, 690-V DFIG supplying to a series-compensated transmission line.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Longitudinal seroprevalence of Crimean-Congo hemorrhagic fever virus in Southern Uganda

Crimean-Congo hemorrhagic fever (CCHF) is a tick-borne disease endemic to many regions of Africa, the Middle East, Southeast Asia and the Balkans. Caused by the CCHF virus (CCHFV), CCHF has been a recognized cause of illness in Uganda since the 1950s and recently, more intensive surveillance suggests CCHFV is widely endemic within the country. Most surveillance has been focused on the Ugandan cattle corridor due to the risk of CCHFV exposure associated with livestock practices. Here we evaluated the seroprevalence of CCHFV in several Southern Ugandan communities outside the cattle corridor combined with longitudinal sample sets to measure the immune response to CCHFV for up to a decade. Interestingly, across three community types, agrarian, trading and fishing, we detected CCHFV seroprevalence in all three but found the highest seroprevalence in fishing communities. We also measured consistent CCHFV-specific antibody responses for up to a decade. Our findings support the conclusion that CCHFV is widely endemic in Uganda and highlight that additional communities may be at risk for CCHFV exposure.

60 APPLIED LIFE SCIENCES↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

Inference-Based Quantum Sensing

In a standard quantum sensing (QS) task one aims at estimating an unknown parameter θ, encoded into an n-qubit probe state, via measurements of the system. The success of this task hinges on the ability to correlate changes in the parameter to changes in the system response $\mathscr{R}$⁡(θ) (i.e., changes in the measurement outcomes). For simple cases the form of $\mathscr{R}$⁡(θ) is known, but the same cannot be said for realistic scenarios, as no general closed-form expression exists. Here, in this Letter, we present an inference-based scheme for QS. We show that, for a general class of unitary families of encoding, $\mathscr{R}$⁡(θ) can be fully characterized by only measuring the system response at 2⁢n+1 parameters. This allows us to infer the value of an unknown parameter given the measured response, as well as to determine the sensitivity of the scheme, which characterizes its overall performance. We show that inference error is, with high probability, smaller than δ, if one measures the system response with a number of shots that scales only as Ω⁢(log 3 ⁡(n)/δ 2 ). Furthermore, the framework presented can be broadly applied as it remains valid for arbitrary probe states and measurement schemes, and, even holds in the presence of quantum noise. We also discuss how to extend our results beyond unitary families. Finally, to showcase our method we implement it for a QS task on real quantum hardware, and in numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Investigation of Low-Frequency Distributed Acoustic Strain-Rate Responses to Propagating Fractures

Summary Low-frequency distributed acoustic sensing (LF-DAS) responds to strain changes due to far-field fracture propagation. To better understand the LF-DAS response to fracture propagation, we performed laboratory-scale hydraulic fracture experiments with embedded optical strain sensors. The objectives of this research are to generate hydraulic fractures of known geometry, measure the strain response along the embedded fiber-optic cable comparable to LF-DAS measurements, and use the results to inform the interpretation of field-derived LF-DAS data. The experiments were conducted in unconfined transparent cubic blocks with a dimension of 8 in. on each side. The block was made of transparent epoxy to visualize the fracture propagation. Fiber-optic sensing cables were embedded in the block at different distances to the source of injection. We injected dyed water through an injection tubing to generate a transverse, radial fracture along an initial flaw. An optical interrogator recorded the response of offset fiber Bragg grating (FBG) strain sensors normal to the plane of the fracture. The strain data were visualized on a waterfall plot, akin to visualizations of field-derived LF-DAS data. Dimensional analysis was used to scale the laboratory results to field conditions. We compared the evolution of the strain response at the fiber-optic cable, injection pressure, and rate with known fracture geometry. The measured strains were compared with Sneddon’s (1946) linear elastic solution for a penny-shaped crack and found to follow this behavior. The generated radial fractures in transparent media can be modeled with Sneddon’s linear elastic radial fracture model and a Mode I critical stress intensity factor. The LF-DAS characteristic response of a narrowing region of extension surrounded by compression was exhibited as a fracture that approached and intersected the fiber-optic cable. The experimentally derived strain and strain-rate waterfall plots with known fracture geometry, injection rate, and pressure response provide insight in understanding LF-DAS responses in the field. Furthermore, we developed a method to estimate fracture geometry evolution from the fiber-optic strain data and validated the method against the experimental data.

Engineering↗

Measuring Fault Zone and Host Rock Hydraulic Properties Using Tidal Responses

Pore pressure diffusion along faults influences induced seismicity and rupture mechanics. In situ hydraulic diffusivity measurements along faults are rare and generally lower than inferred from seismicity migration. Here we use the tidal response of deep geothermal boreholes to measure fault diffusivity and permeability. Initial interpretations of the observation with a homogeneous confined aquifer model result in diffusivities of 10 -3 –10 -1 m 2 /s. However, this model mixes signals from both the conduit and the host rock. We develop a model for tidal response with a fault passing through the aquifer based on the fault-guided fracture network and solve for hydraulic properties in both the fault and the host rock. The resulting fault permeability is 2 × 10 -14 –7 × 10 -14 m 2 (90% confidence interval[CI]) and fault diffusivity is 0.08–0.33 m 2 /s (90% CI), which is 2 orders of magnitude higher than the host rock diffusivity in some wells, thus highlighting the role of faults as fluid conduits.

58 GEOSCIENCES↗

Constitutive Model Development for Aging Polymer Encapsulants (ASC P&EM FY2021 L2 Milestone 7836)

This SAND report fulfills the completion requirements for the ASC Physics and Engineering Modeling Level 2 Milestone 7836 during Fiscal Year 2021. The Sandia Simplified potential energy clock (SPEC) non-linear viscoelastic constitutive model was developed to predict a whole host of polymer glass physical behaviors in order to provide a tool to assess the effects of stress on these materials over their lifecycle. Polymer glasses are used extensively in applications such as electronics packaging, where encapsulants and adhesives can be critical to device performance. In this work, the focus is on assessing the performance of the model in predicting material evolution associated with long-term physical aging, an area that the model has not been fully vetted in. These predictions are key to utilizing models to help demonstrate electronics packaging component reliability over decades long service lives, a task that is very costly and time consuming to execute experimentally. The initiating hypothesis for the work was that a model calibration process can be defined that enables confidence in physical aging predictions under ND relevant environments and timescales without sacrificing other predictive capabilities. To test the hypothesis, an extensive suite of calibration and aging data was assembled from a combination of prior work and collaborating projects (Aging and Lifetimes as well as the DoD Joint Munitions Program) for two mission relevant epoxy encapsulants, 828DGEBA/DEA and 828DGEBA/T403. Multiple model calibration processes were developed and evaluated against the entire set of data for each material. A qualitative assessment of each calibration's ability to predict the wide range of aging responses was key to ranking the calibrations against each other. During this evaluation, predictions that were identified as non-physical, i.e., demonstrated something that was qualitatively different than known material behavior, were heavily weighted against the calibration performance. Thus, unphysical predictions for one aspect of aging response could generate a lower overall rating for a calibration process even if that process generated better quantitative predictions for another aspect of aging response. This insurance that all predictions are qualitatively correct is important to the overall aim of utilizing the model to predict residual stress evolution, which will depend on the interplay amongst the different material aging responses. The DSC-focused calibration procedure generated the best all-around aging predictions for both materials, demonstrating material models that can qualitatively predict the whole host of different physical aging responses that have been measured. This step forward in predictive capability comes from an unanticipated source, utilization of calorimetry measurements to specify model parameters. The DSC-focused calibration technique performed better than compression-focused techniques that more heavily weigh measurements more closely related to the structural responses to be predicted. Indeed, the DSC-focused calibration procedure was only possible due to recent incorporation of the enthalpy and heat capacity features into SPEC that was newly verified during this L2 milestone. Fundamentally similar aspects of the two material model calibrations as well as parametric studies to assess sensitives of the aging predictions are discussed within the report. A perspective on the next steps to the overall goal of residual stress evolution predictions under stockpile conditions closes the report.

36 MATERIALS SCIENCE↗