Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

High-Temperature Rotating Disk Electrode Study of Platinum Bimetallic Catalysts in Phosphoric Acid

Understanding the H 3 PO 4 effect on the catalyst’s activity under a relevant condition is important for high-temperature polymer electrolyte membrane fuel cell (HT-PEMFC) catalyst research. Here, we report a high-temperature rotating disk electrode (HT-RDE) study of oxygen reduction reaction (ORR) in H 3 PO 4 . With the regular electrochemical protocol, we found that H 3 PO 4 reduction could occur during cyclic voltammetry study and form a reductive species—phosphorus acid (H 3 PO 3 ). Further, to obtain reliable ORR measurement, we optimized the protocol to avoid the H 3 PO 3 generation. The ORR activity of carbon-supported PtM (M = Fe, Co, Ni, Ru, Pd, and Ir) bimetallic alloy catalysts measured with this HT-RDE method showed higher ORR activity than Pt. To understand the alloying effect, we combine experiments in diluted solutions to distinguish the alloying effect on Pt–O binding and Pt–H 3 PO 4 binding. The results indicate that H 3 PO 4 mainly reduces available sites for ORR, with little effect on neighboring site’s Pt–O binding via Pt–H 3 PO 4 interaction, which is also supported by the density functional theory calculation of the Pt–O binding energy with/without H 2 PO 4 . Further study in a phosphoric acid-doped quaternary ammonium-biphosphate ion pair coordinated polyphenylene (PA-QAPOH) membrane electrode assembly (MEA) shows that the active alloy catalyst has better performance in both the HT-RDE and MEA. Also, the MEA gives higher ORR activity than the HT-RDE because of the higher pressure and less phosphoric acid content of the MEA. Yet, the gap between the HT-RDE and MEA is significantly smaller than that between the room temperature (RT)-RDE and MEA, suggesting the importance of temperature and H 3 PO 4 concentration in understanding ORR in HT-PEMFCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Quality Factor Microwave Resonators using Rhenium

Coplanar waveguide resonators are a perfect tool to evaluate the losses induced by defects and interfaces in superconducting devices. Even if niobium is the most used superconductor for resonators and qubits, its native oxide at the metal-air (MA) interface limits the device results. Tantalum has recently significantly improved qubit performances due to a thinner and less disordered oxide layer compared to Nb. To further improve the MA interface, we used rhenium, a superconducting material with 1.7 K critical temperature resistant to oxidation: it forms an oxide layer thinner than 1 nm. In this study, we will present a thorough investigation of rhenium CPW resonator measurements with internal quality factors at the single photon level exceeding 2 million. The devices have been fabricated on a sapphire substrate while the processing parameters have been varying and optimized. The measurements have been performed as a function of power and temperature to disentangle different sources of losses, such as two-level systems (TLS) and quasi-particles. A peculiar TLS temperature dependence has been measured and analyzed. In this work, we also vary the participation ratio of the devices to extract the losses introduced by the involved interfaces with higher fidelity and precision. We carried on a deep material characterization effort to link the results to the differences in the fabrication steps, and we will present material characterization measurements performed via AFM, ToF-SIMS, XPS, and TEM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An optimal guarding scheme for thermal conductivity measurement using a guarded cut-bar technique, part 1 experimental study

In the guarded cut-bar technique, a guard surrounding the measured sample and reference (meter) bars is temperature controlled to carefully regulate heat losses from the sample and reference bars. Guarding is typically carried out by matching the temperature profiles between the guard and the test stack of sample and meter bars. Problems arise in matching the profiles, especially when the thermal conductivitiesof the meter bars and of the sample differ, as is usually the case. In a previous numerical study, the applied guarding condition (guard temperature profile) was found to be an important factor in measurement accuracy. Different from the linear-matched or isothermal schemes recommended in literature, the optimal guarding condition is dependent on the system geometry and thermal conductivity ratio of sample to meter bar. To validate the numerical results, an experimental study was performed to investigate the resulting error under different guarding conditions using stainless steel 304 as both the sample and meter bars. The optimal guarding condition was further verified on a certified reference material, pyroceram 9606, and 99.95% pure iron whose thermal conductivities are much smaller and much larger, respectively, than that of the stainless steel meter bars. Additionally, measurements are performed using three different inert gases to show the effect of the insulation effective thermal conductivity on measurement error, revealing low conductivity, argon gas, gives the lowest error sensitivity when deviating from the optimal condition. The result of this study provides a general guideline for the specific measurement method and for methods requiring optimal guarding or insulation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Linearity and Write Noise of Analog Resistive Memory Devices in a Neural Algorithm Accelerator

Resistive memory (ReRAM) shows promise for use as an analog synapse element in energy-efficient neural network algorithm accelerators. A particularly important application is the training of neural networks, as this is the most computationally-intensive procedure in using a neural algorithm. However, training a network with analog ReRAM synapses can significantly reduce the accuracy at the algorithm level. In order to assess this degradation, analog properties of ReRAM devices were measured and hand-written digit recognition accuracy was modeled for the training using backpropagation. Bipolar filamentary devices utilizing three material systems were measured and compared: one oxygen vacancy system, Ta-TaO x , and two conducting metallization systems, Cu-SiO 2 , and Ag/chalcogenide. Analog properties and conductance ranges of the devices are optimized by measuring the response to varying voltage pulse characteristics. Key analog device properties which degrade the accuracy are update linearity and write noise. Write noise may improve as a function of device manufacturing maturity, but write nonlinearity appears relatively consistent among the different device material systems and is found to be the most significant factor affecting accuracy. As a result, this suggests that new materials and/or fundamentally different resistive switching mechanisms may be required to improve device linearity and achieve higher algorithm training accuracy.

97 MATHEMATICS AND COMPUTING↗

Effective Access Monitoring at Geological Repositories

Access points at a deep, mined geological repository (GR) for the disposal of spent nuclear fuel (SNF) and other nuclear wastes present potential diversion paths for nuclear material. Because C/S measures are not likely to be used underground, access to a GR will require unprecedented reliance on C/S measures to maintain continuity of knowledge (CoK) on SNF buried underground. We develop a model GR based on common features of GR designs from national programs in order to develop and optimize C/S measures for GR access points that maximize confidence that CoK is maintained on SNF underground. Critical access points identified in this study are surface entrances to (1) the GR ramp (2) the excavation shaft, (3) the main elevator shaft, and (4) the ventilation shaft. The first three are considered critical detection points (DPs), whereas the fourth is considered a non-critical DP. The reason for the distinction is due to the different design capabilities of shaft components: the first three (ramp, excavation shaft, main elevator) are all capable of being used to move material from the underground to the surface, whereas the ventilation shaft is not. Such capabilities are verified during periodic design information verification (DIV) inspections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementation of a System of Gamma Imagers for Measuring Plutonium Holdup

The Surplus Plutonium Disposition (SPD) project is an effort to dilute and dispose of many tonsof weapons grade plutonium. This work will take place in a shielded glovebox to protect workers fromradiological dose. Accurate measurements of the holdup, or material left behind, in the gloveboxes is im-portant for Nuclear Material Control and Accountancy, worker dose minimization, criticality safety, andprocess monitoring. Shielding around the gloveboxes presents an obstacle for the traditional GeneralizedGamma Holdup (GGH) method. The uncertainties associated with that method, at around 28%, arealso detrimental since the amount of holdup must be kept below an established limit with a high level ofconfidence.Passive gamma-ray imaging provides a more complete depiction of the distribution of radioactivematerials. Recent refinement of the method has demonstrated that quantitative information can beextracted from the images with a well-characterized system. A permanently installed system of gamma-ray imagers is currently being developed to measure plutonium holdup in the SPD gloveboxes. Thispaper will report on progress with the development of this system.This application requires that the features of current commercially available instruments from H3Dand PHDS, optimized for measurement performance in a mobile application, be translated into theconstraints of the operational environment with fixed installations. The interaction between facilityconstraints and measurement capabilities will be addressed.A series of measurements with plutonium sources in a mocked-up glovebox geometry with imagersmounted above the ceiling of the glovebox have been taken. Imager performance with respect to angularresolution, minimum measurement time for quantification, and signal-to-noise ratio with a multitudeof sources will be evaluated for those measurements. A series of prototypes of user interfaces will bepresented for display of the data to its various consumers for the purposes of Nuclear Material Controland Accountancy, worker dose minimization, criticality safety, and process monitoring.

Schmitt, Kyle↗

Accessing glue through photoproduction measurements at GlueX

Photoproduction experiments are a key tool in the investigation of the spectrum of hadronic states and the way gluons contribute to this spectrum. The GlueX experiment, located at Jefferson Lab, features a linearly polarized tagged photon beam and its detector system is optimized to measure a wide range of neutral and charged final states. GlueX offers unique capabilities to study the spectrum of hadrons and is dedicated to the search for hybrid mesons, states with gluonic degrees of freedom. This talk presents first results from our initial campaign of data taking which finished in 2018.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of the thermogauge furnace for realizing high temperature fixed points

The thermogauge furnace was commonly used in many NMIs as a blackbody source for calibration of the radiation thermometer. It can also be used for realizing the high temperature fixed point(HTFP). According to our experience, when realizing HTFP we need the furnace provide relative good temperature uniformity to avoid the possible damage to the HTFP. To improve temperature uniformity in the furnace, the furnace tube was machined near the tube ends with a help of a simulation analysis by 'ansys workbench'. Temperature distributions before and after optimization were measured and compared at 1300 °C, 1700°C, 2500 °C, which roughly correspond to Co-C(1324 °C), Pt-C(1738 °C) and Re-C(2474 °C), respectively. The results clearly indicate that through machining the tube the temperature uniformity of the Thermogage furnace can be remarkably improved. A Pt-C high temperature fixed point was realized in the modified Thermogauge furnace subsequently, the plateaus were compared with what obtained using old heater, and the results were presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a capacitance measurement for pulsed magnetic fields

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an auto-balancing bridge method, leveraging a high-bandwidth transimpedance amplifier to mitigate parasitic contributions from coaxial cables. This technique enables precise capacitance measurements in rapidly changing magnetic fields, as demonstrated in experiments on the magnetoelectric material NiCo 2 TeO 6 . The results reveal strong magnetoelectric coupling, including a pronounced hysteresis in capacitance that coincides with magnetization measurements and an enhanced energy dissipation peak at high sweep rates. Compared to traditional LCR meter measurements in DC fields, our method exhibits excellent agreement while providing additional insight into field-induced phase transitions. This work establishes a robust methodology for capacitance measurements under extreme conditions and opens new opportunities for studying multiferroic and correlated electron systems under high magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Facility Safeguardability Analysis In Support of Safeguards-by-Design

The following report proposes the use of Facility Safeguardability Analysis (FSA) to: i) compare and evaluate nuclear safeguards measures, ii) optimize the prospective facility safeguards approach, iii) objectively and analytically evaluate nuclear facility safeguardability, and iv) evaluate and optimize barriers within the facility and process design to minimize the risk of diversion and theft of nuclear material. As proposed by the authors, Facility Safeguardability Analysis would be used by the Facility Designer and/or Project Design Team during the design and construction of the nuclear facility to evaluate and optimize the facility safeguards approach and design of the safeguards system. Through a process of “Safeguards-by-Design” (SBD), this would be done at the earliest stages of project conceptual design and would involve domestic and international nuclear regulators and authorities, including the International Atomic Energy Agency (IAEA). The benefits of the Safeguards-by-Design approach is that it would clarify at a very early stage the international and domestic safeguards requirements for the Construction Project Team, and the best design and operating practices for meeting these requirements. It would also minimize the risk to the construction project, in terms of cost overruns or delays, which might otherwise occur if the nuclear safeguards measures are not incorporated into the facility design at an early stage. Incorporating nuclear safeguards measures is straight forward for nuclear facilities of existing design, but becomes more challenging with new designs and more complex nuclear facilities. For this reason, the facility designer and Project Design Team require an analytical tool for comparing safeguards measures, options, and approaches, and for evaluating the “safeguardability” of the facility. The report explains how preliminary diversion path analysis and the Proliferation Resistance and Physical Protection (PRPP) evaluation methodology can be adapted for evaluating and assessing the safeguardability of nuclear facilities – both existing, as well as those still on the drawing board. The advantages of the Facility Safeguardability Analysis is that it would not only give the facility designer an analytical method for evaluating and assessing the safeguards measures and approaches for the prospective facility, but also the ability to optimize the design of the facility process for enhancing facility safeguardability. The following report explains the need for Facility Safeguardability Analysis and explains how it could be used in the Safeguards-by-Design, in support of the design and construction of nuclear facilities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear waste calorimeter for very large drums with 385 litres sample volume

Calorimetry is a very precise and well adapted tool for the classification of drums containing nuclear waste material depending on their level of activities (low, medium, high). A new calorimeter has been developed by SETARAM Instrumentation and the CEA Valduc in France. This new calorimeter is designed for drums having a volume bigger than 100 liters. It guarantees high operator safety by optimizing drum handling and air circulation for cooling, and optimized software for direct measurement of the quantity of nuclear material. The LVC1380 calorimeter makes it possible to work over the range 10 to 3000 mW, which corresponds to approximately 0.03 to 10 g of tritium or 3 to 955 g of {sup 241}Pu in a volume up to 385 liters. This calorimeter is based on the heat flow measurement using Peltier elements which surround the drum in the 3 dimensions and therefore measure all the heat coming from the radioactive stuff whatever its position inside the drum. Calorimeter's insulating layers constitute a thermal barrier designed to filter disturbances until they represent less than 0.001 Celsius degrees and to eliminate long term disturbances associated, for example, with laboratory temperature variations between day and night. A calibration device based on Joule effect has also been designed. Measurement time has been optimized but remains long compared with other methods of measurement such as gamma spectrometry but its main asset is to have a good accuracy for low level activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Tool Kit for Generating Simulated Radiation Measurements for Advanced Reactor Safeguards and Security

A tool kit was developed to simulate and analyze passive radiation measurements of molten salt reactor (MSR) operations to support development of nuclear safeguards approaches for this emerging reactor technology. A Transient Simulation Framework of Reconfigurable Modules (TRANSFORM) multiphysics simulation of an MSR produces time-dependent isotopic inventories at user-selected locations within the model. The tool kit implements the Gamma Detector Response and Analysis Software (GADRAS) application programming interface to inject the TRANSFORM isotopic inventories extracted/processed by a Python pipeline into GADRAS models of user-defined geometries. The TRANSFORM inventories are the source terms used to obtain synthetic measurements from GADRAS-defined detectors. The speed of TRANSFORM and GADRAS simulations enables surveying the large design space of MSRs (e.g., fuel type, fuel salt composition, number of loops) and the plethora of measurements (e.g., location, detector type, and collimation) within the reactor. This has enabled timely assessment of the various measurement locations and detectors to identify the most effective and efficient safeguards approach for a specific MSR design. Lastly, the tool kit also simulates extracted samples that can be aged to a desired dose, enabling stakeholders to optimize a measurement plan to use sample analysis as an element within a broader material accountancy plan.

Westphal, Greg↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Lightweight Integrated Optical Sensor for Atmospheric Measurements on Mobile Platforms

The goal of the Phase I program was to develop a novel open path sensor platform technology based on integration of semiconductor waveguides with efficient optoelectronic components on a monolithic platform. The successful Phase I effort resulted in demonstration of a novel optical resonator structure based on semiconductor high contrast gratings (HCGs) that will enable implementation of an ultra-compact, low-power gas sensor suitable for use on mobile platforms. Extensive numerical modeling was performed to design a device optimized for measuring CO2 at a wavelength for which a laser was available for proof of concept. Devices were fabricated and tested to match the target wavelength, angle, and operating temperature. This demonstration is the first implementation of HCGs at the wavelengths of interest and shows the flexibility of the proposed architecture for gas sensing applications. The measured cavity Q was lower than anticipated due to fabrication process challenges. The PSI and UC Berkeley team has identified solutions to these challenges and will produce optimized devices in a Phase II program where a prototype sensor will be fabricated and tested.

54 ENVIRONMENTAL SCIENCES↗

In-vessel design of ITER diagnostic neutron activation system

A neutron activation system utilizing an encapsulated metal sample technique will be implemented to evaluate total fusion power from ITER plasma. The positions of seven irradiation ends for each poloidal section are determined to optimize the measurements from asymmetric, elongated plasma with minimum uncertainty. To determine the exact location of the irradiation end, some physical and technical aspects for each location are investigated. Monte Carlo neutronic calculations are performed to assess the physical characteristics and optimize the design of each irradiation end.

36 MATERIALS SCIENCE↗

Centrality determination with a forward detector in the RHIC Beam Energy Scan

Recently, Chatterjee et al [1] used a hadronic transport model to estimate the resolution with which various experimental quantities select the impact parameter of relativistic heavy ion collisions at collision energies relevant to the Beam Energy Scan (BES) program at the Relativistic Heavy Ion Collider (RHIC). Measures based on particle multiplicity at forward rapidity were found to be significantly worse than those based on midrapidity multiplicity. Using the same model, we show that a slightly more sophisticated measure greatly improves the resolution based on forward rapidity particles; this improvement persists even when the model is filtered through a realistic simulation of a recent upgrade detector to the STAR experiment. Furthermore, these results highlight the importance of optimizing centrality measures based on particles detected at forward rapidity, especially for experimental studies that search for a critical point in the QCD phase diagram. Such measurements usually focus on proton multiplicity fluctuations at midrapidity, hence selecting events based on multiplicity at midrapidity raises the possibility of nontrivial autocorrelations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hot Coordinate Measuring Machine Technical Specifications and Requirements (U)

The goal of this document is to outline the technical specifications and requirements for a new Hot Coordinate Measuring Machine at TA-55. This document should be used in conjunction with the information provided from TA-55 Hot CMM Location Study and TA-55 Hot CMM Technology Assessment. All three documents will guide the user to the optimal coordinate measuring machine selection.

42 ENGINEERING↗