Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Plate measurement techniques and reduction methods used by the West German satellite observers, and resulting consequences for the observation

The West German tracking stations are equipped with ballistic cameras. Plate measurement and plate reduction must therefore follow photogrammetric methods. Approximately 100 star positions and 200 satellite positions are measured on each plate. The mathematical model for spatial rotation of the bundle of rays is extended by including terms for distortion and internal orientation of the camera as well as by providing terms for refraction which are computed for the measured coordinates of the star positions on the plate. From the measuring accuracy of the plate coordinates it follows that the timing accuracy for the exposures has to be about one millisecond, in order to obtain a homogeneous system.

Deker, H.↗

Applications of dynamic measurement techniques to wind-tunnel testing

The uses of laser Doppler velocimeter, hot wire, and surface hot film techniques in the study of turbulent flows are described, and data obtained in compressible flows are discussed. Applications are illustrated with measurements of wind tunnel freestream turbulence characteristics and with data obtained in transitional, turbulent, and separated shear flows. A new method which was developed for the study of time dependent and unsteady turbulent flows is also presented.

Owen, F. K.↗

Development of reactivity feedback effect measurement techniques under sub-critical condition in fast reactors

The first-of-a-kind reactor has been licensed by a safety examination of the plant design based on the measured data in precedent mock-up experiments. The validity of the safety design can be confirmed without a mock-up experiment, if the reactor feed-back characteristics can be measured before operation, with the constructed reactor itself. The 'Synthesis Method', a systematic and sophisticated method of sub-criticality measurement, is proposed in this work to ensure the safety margin before operation. The 'Synthesis Method' is based on the modified source multiplication method (MSM) combined with the noise analysis method to measure the reference sub-criticality level for MSM. A numerical simulation for the control-rod reactivity worth and the isothermal feed-back reactivity was conducted for typical fast reactors of 100 MWe-size, 300 MWe-size, 750 MWe-size, and 1500 MWe-size to investigate the applicability of Synthesis Method. The number of neutron detectors and their positions necessary for the measurement were investigated for both methods of MSM and the noise analysis by a series of parametric survey calculations. As a result, it was suggested that a neutron detector located above the core center and three or more neutron detectors located above the radial blanket region enable the measurement of sub-criticality within 10% uncertainty from -$0.5 to -$2 and within 15% uncertainty for the deeper sub-criticality. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of methane emission estimates from multiple measurement techniques at natural gas production pads

This study presents the results of a campaign that estimated methane emissions at 268 gas production facilities in the Fayetteville shale gas play using onsite measurements (261 facilities) and two downwind methods - the dual tracer flux ratio method (Tracer Facility Estimate - TFE, 17 facilities) and the EPA Other Test Method 33a (OTM33A Facility Estimate - OFE, 50 facilities). A study onsite estimate (SOE) for each facility was developed by combining direct measurements and simulation of unmeasured emission sources, using operator activity data and emission data from literature. The SOE spans 0-403 kg/h and simulated methane emissions from liquid unloadings account for 88% of total emissions estimated by the SOE, with 76% (95% CI [51%-92%]) contributed by liquid unloading at two facilities. TFE and SOE show overlapping 95% CI between individual estimates at 15 of 16 (94%) facilities where the measurements were paired, while OFE and SOE show overlapping 95% CI between individual estimates at 28 of 43 (65%) facilities. However, variance-weighted least-squares (VWLS) regressions performed on sets of paired estimates indicate statistically significant differences between methods. The SOE represents a lower bound of emissions at facilities where onsite direct measurements of continuously emitting sources are the primary contributor to the SOE, a sub-selection of facilities which minimizes expected inter-method differences for intermittent pneumatic controllers and the impact of episodically-emitting unloadings. At 9 such facilities, VWLS indicates that TFE estimates systematically higher emissions than SOE (TFE-to-SOE ratio = 1.6, 95% CI [1.2 to 2.1]). At 20 such facilities, VWLS indicates that OFE estimates systematically lower emissions than SOE (OFE-to-SOE ratio of 0.41 [0.26 to 0.90]). Given that SOE at these facilities is a lower limit on emissions, these results indicate that OFE is likely a less accurate method than SOE or TFE for this type of facility.

03 NATURAL GAS↗

LISA phase measurement technique

The LISA mission will form the equivalent of a Michelson interferometric beat signal from the 1064nm laser beams traversing the inter-spacecraft arms. The design gravitational wave sensitivity requires measurement of round trip path differences for each detector to be about 10 pddHz over a frequency range from 10^10-4 to 10^-1 Hz. Thus LISA'S phasemeter must measure the beat signal phase to 10^-5 cycle/square root of Hz at 1mHz. Doppler shifts between spacecraft in their orbits are expected to range from 1 to 15 MHz. Phase measurement using the digital phase-locked loop approach incorporated in a modified TurboRogue GPS receiver has been investigated in this study. It is found that only resolution in the range of 10^-4 to 10^-3 cycle/square root of Hz at 1 mHz is achievable with this hardware. Abrupt fluctuations in the phase measurement at the millicycle level are responsible for the limitation.

phasemeter↗

Optical Measurement Technique for Space Column Characterization

A simple optical technique for the structural characterization of lightweight space columns is presented. The technique is useful for determining the coefficient of thermal expansion during cool down as well as the induced strain during tension and compression testing. The technique is based upon object-to-image plane scaling and does not require any photogrammetric calibrations or computations. Examples of the measurement of the coefficient of thermal expansion are presented for several lightweight space columns. Examples of strain measured during tension and compression testing are presented along with comparisons to results obtained with Linear Variable Differential Transformer (LVDT) position transducers.

Barrows, Danny A.↗

The Dynamic Assimilation Technique measures photosynthetic CO2 response curves with similar fidelity as steady-state approaches in half the time

The net CO2 assimilation (A) response to intercellular CO2 concentration (Ci) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/Ci protocols rely on steady-state measurements and take 15-40 minute per measurement, limiting data resolution or biological replication. Additionally, there are several CO2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady state Dynamic Assimilation Technique (DAT) protocol and the three most used CO2 protocols in steady-state measurements, and tested whether different CO2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis.

A/Ci response↗

The Dynamic Assimilation Technique measures photosynthetic CO 2 response curves with similar fidelity to steady-state approaches in half the time

The net CO 2 assimilation (A) response to intercellular CO 2 concentration (C i ) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/C i protocols rely on steady-state measurements and take 15–40 min per measurement, limiting data resolution or biological replication. Additionally, there are several CO 2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady-state Dynamic Assimilation Technique (DAT) protocol and the three most used CO 2 protocols in steady-state measurements, and tested whether different CO 2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis. The DAT protocol reduced the measurement time by almost half without compromising estimation accuracy or precision. The monotonic protocol was the fastest steady-state method. Estimations of biochemical limitations to photosynthesis were very consistent across all CO 2 protocols, with slight differences in Rubisco carboxylation limitation. The A/C i curves were not affected by the direction of the change of CO 2 concentration but rather the time spent under triose phosphate utilization (TPU)-limited conditions. Our results suggest that the maximum rate of Rubisco carboxylation (V cmax ), linear electron flow for NADPH supply (J), and TPU measured using different protocols within the literature are comparable, or at least not systematically different based on the measurement protocol used.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.

Meginnis, Ian M.↗

Modulation Transfer Function (MTF) measurement techniques for lenses and linear detector arrays

Application is the determination of the Modulation Transfer Function (MTF) for linear detector arrays. A system set up requires knowledge of the MTF of the imaging lens. Procedure for this measurement is described for standard optical lab equipment. Given this information, various possible approaches to MTF measurement for linear arrays is described. The knife edge method is then described in detail.

Schnabel, J. J., Jr.↗

The study of pressure measurement techniques and devices in the range of 10(exp -1) to 10(exp -5) torr (2 millipsi to 0.2 micropsi)

The atmospheric pressure range was studied in a region where conventional pressure sensing devices do not provide meaningful measurements. However, a hot filament gauge was developed and miniaturized which will measure the pressure in the 10(exp -1) to 10(exp -5) torr (2 millipsi to 0.2 micropsi) region, hence the name Micropsi gauge. Laboratory studies were made comparing the currently available devices with the newly developed miniature low power 'Micropsi' pressure sensor.

Hoffman, John H.↗

IN SITU MEASUREMENT TECHNIQUES FOR CHARACTERIZING PULSE JET MIXING OF SLURRIES

Metrics to characterize mixing are the just suspended velocity (UJS) and the cloud height (HC). Two ultrasonic instruments to characterize pulse jet mixing of slurries were developed and deployed to measure related metrics: the thickness of the settled bed and the concentration within the cloud as a function of elevation [C(Z)]. Ultrasonic Doppler velocimetry was used to measure the thickness of the bed of nonmoving particles (the settled solids layer). During pulse jet mixing at the critical suspension velocity (UCS) the settled solids layer thickness approached zero at the end of the jet pulse. The UCS is related to the just suspended velocity (UJS) for steady mixing. Ultrasonic attenuation was used to measure the suspended solids concentration at locations in the vessel to determine the concentration profile as a function of radial position and elevation. The concentration profile provided data inside the cloud and complemented the visual measurement of the cloud height (HC). The UDV and the ultrasonic concentration probe data are used to evaluate the desired metrics based on relative measurements. The relative measurements are correlated with results obtained from a series of working standards created for each slurry, and used to develop correlations specific to each slurry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theory and Methods of Photovoltaic Material Characterization: Optical and Electrical Measurement Techniques

This book provides an extensive review of the theory of transport and recombination properties in semiconductors. The emphasis is placed on electrical and optical techniques. There is a presentation of the latest experimental and theoretical techniques used to analyze minority-carrier lifetime. The relevant hardware and instrumentation are described. The newest techniques of lifetime mapping are presented. The issues are discussed relating to effects that mask carrier lifetime in certain device structures. The discrepancy between photoconductive and photoluminescence measurement results are analyzed.

14 SOLAR ENERGY↗

Downward-deployed tethered satellite systems, measurement techniques, and instrumentation - A review

This paper describes a number of scheduled and proposed Shuttle-based downward-deployed tethered satellite systems (TSSs) the purpose of which is to determine the structure of the lower thermosphere and to measure the atmospheric and aerodynamic effects in the vicinity of the satellite, the aerothermodynamic effects on the satellite's surface, and the dynamics of the tether and its endmass, the satellite. The instruments for the downward-deployed tethered missions will include mass spectrometers and other density sensors, plasma instrumentation, optical spectrophotometers, magnetometers, and instrumentation to measure the effects on satellite surface (such as the surface temperature, heat transfer, and pressure; gas adsorption on surfaces, chemistry with other gas molecules and surface material, and desorption from the surface; and surface charging).

Brown, Kenneth G.↗

Synchronous (Lock-in) Measurement Techniques for Magnetic Contrast Enhancement in STXM

We have explored the capabilities of synchronous ('lock-in') point detection techniques to enhance the x-ray magnetic circular dichroism (XMCD) contrast in scanning x-ray transmission microscopy (STXM) of magnetic thin-film microstructures. Local absorption contrast, measured synchronously with low-amplitude (<10 Oe) and low-frequency (<200 hz) longitudinal fields perturbing the near-remanent magnetization state, reveal a strong spatial dependence of the response, with a roll-off in frequency response above 200 Hz. In this context, synchronous measurement affords us a basis for imaging the relation between energy loss and the sweeping rate. We speculate that the lock-in approach will be uniquely suited for detailing stochastic and deterministic frequency-dependent events in the process of magnetization reversal.

36 MATERIALS SCIENCE↗

Acoustic analysis of aft noise reduction techniques measured on a subsonic tip speed 50.8 cm (twenty inch) diameter fan

Sound data which were obtained during tests of a 50.8 cm diameter, subsonic tip speed, low pressure ratio fan were analyzed. The test matrix was divided into two major investigations: (1) source noise reduction techniques; and (2) aft duct noise reduction with acoustic treatment. Source noise reduction techniques were investigated which include minimizing second harmonic noise by varying vane/blade ratio, variation in spacing, and lowering the Mach number through the vane row to lower fan broadband noise. Treatment in the aft duct which includes flow noise effects, faceplate porosity, rotor OGV treatment, slant cell treatment, and splitter simulation with variable depth on the outer wall and constant thickness treatment on the inner wall was investigated. Variable boundary conditions such as variation in treatment panel thickness and orientation, and mixed porosity combined with variable thickness were examined. Significant results are reported.

Stimpert, D. L.↗

Full-field Deformation Measurement Techniques for a Rotating Composite Shaft

Test methods were developed to view global and local deformation in a composite tube during a test in which the tube is rotating at speeds and torques relevant to rotorcraft shafts. Digital image correlation (DIC) was used to provide quantitative displacement measurements during the tests. High speed cameras were used for the DIC measurements in order to capture images at sufficient frame rates and with sufficient resolution while the tube was rotating at speeds up to 5,000 rpm. Surface displacement data was resolved into cylindrical coordinates in order to measure rigid body rotation and global deformation of the tube. Tests were performed on both undamaged and impact damaged tubes in order to evaluate the capability to detect local deformation near an impact damaged site. Measurement of radial displacement clearly indicated a local buckling deformation near the impacted site in both dynamic and static tests. X-ray computed tomography (CT) was used to investigate variations in fiber architecture within the composite tube and to detect impact damage. No growth in the impact damage area was observed by DIC during dynamic testing or by x-ray CT in post test inspection of the composite tube.

Kohlman, Lee W.↗