Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A review of experimental methods to determine bioaerosol transfer in energy recovery ventilators

Increasing ventilation is an effective method to reduce indoor airborne disease transmission. An Energy recovery ventilator (ERV) is a passive energy recovery device used to reduce the energy consumption of heating, ventilation and air-conditioning (HVAC) systems for conditioning the ventilation air. It preconditions the ventilation air by transferring energy from building exhaust air. Therefore, the ventilation and exhaust air streams interact directly/indirectly in the ERV for energy transfer. It is surmised that the ERV may transfer bioaerosols (with pathogens) from the exhaust air to ventilation air, resulting in the spread of infectious diseases. Consequently, many pandemic HVAC guidelines recommend that the use of ERVs be limited. This is a highly unsustainable direction given the increased energy requirements associated with the high ventilation provision advocated for pandemic operation. It must be noted that no validated experimental evidence exists in literature for bioaerosol transfer in ERVs. Hence, it is necessary to conduct extensive bioaerosol transfer research before adopting the unsustainable practice of limiting the utilization of ERVs. The main objective of this review study is to summarize the experimental methods and instrumentation for bioaerosol transfer research in ERVs. This comprehensive article provides a detailed overview of the generation, sampling, and analysis of bioaerosols for conducting the experiments. Further, it explains the possible mechanisms for bioaerosol transfer in various types of ERVs based on which the ERVs that need immediate attention are identified. The main contribution of this research paper is that it provides a novel experimental method which encompasses the biosafety aspects, instrumentation, performance parameters and uncertainties in conducting virus contained bioaerosol transfer study in ERVs. The findings from this review will be helpful in designing bioaerosol transfer experiments and developing future ERV test standards for such experiments.

42 ENGINEERING↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exploring Coupled Extreme Environments via In-situ Transmission Electron Microscopy

In-situ transmission electron microscopy (TEM) provides an avenue to explore time-dependent nanoscale material changes induced by a wide range of environmental conditions that govern material performance and degradation. The In-situ Ion Irradiation TEM (I 3 TEM) at Sandia National Laboratories is a JEOL 2100 microscope that has been highly modified with an array of hardware and software that makes it particularly well suited to explore fundamental mechanisms that arise from coupled extreme conditions. Here, examples pertaining to multibeam ion irradiation, rapid thermal cycling, and nanomechanical testing on the I 3 TEM are highlighted, along with prospective advancements in the field of in-situ microscopy.

47 OTHER INSTRUMENTATION↗

Uncertainty analysis of steady-state measurements with a hot-filament type calorimetric emissometer

Calorimetric emissometers measure total hemispherical emissivity by measuring the heat transferred from a heated sample to its surroundings under a vacuum. The accuracy of emissometers standardized by the ASTM C835-06 are well understood. This work uses the Guide to the Evaluation of Uncertainty in Measurement (GUM) for the propagation uncertainties for an ASTM compliant emissometer. The GUM method was able to develop a measurement model and expressions to determine the uncertainty for other emissometers of this type. Data on ‘as-received’ Hastelloy X was used to develop a detailed uncertainty analysis of the emissivity measurement. Data on ‘as-received’ SS 347 and sandblasted A387 Gr. 91 and previous data by the group on A508/A533B were used to determine uncertainty over the ranges 0.16 to 0.81. For all samples, relative uncertainties in emissivities varied from 0.77% to 2.5% when using a fluxgate magnetometer sensor (FMS) to measure the DC heating current. Data on Hastelloy X using a Hall-effect sensor for DC current and low alloy steel showed the DC current and voltage across the test section to be dominate sources of uncertainty. When these sources were reduced, the specimen temperature and the surface area of the test sections were main sources of uncertainty in the emissivity, especially at higher temperatures. As thermal expansion of the surface was considered in the calculations, correlation between specimen temperature and surface area was examined. It was found to be a small contribution to emissivity's uncertainty despite the differences in linear CTE and its uncertainty for the materials analyzed in this study. For low temperatures, the chamber temperature can be a significant source of uncertainty if not sufficiently cooled. The GUM was also briefly compared to uncertainty from the 2nd and 3rd expansions of the Taylor series. We found that the results were the same when rounding to two significant figures.

42 ENGINEERING↗

Combining cross-pivot flexures to generate improved kinematically equivalent flexure systems

In this work, we show that new kinematic equivalents with improved performance of standard flexure elements can be systematically synthesized by combination of cross-pivot flexures. Cross-pivot flexures provide a unique feature of kinematic stability under both high loading and large displacement conditions which can be exploited to synthesize a range of kinematic equivalents to standard flexure elements which retain much greater stiffness, load capacity and range capacity than the traditional elements. Cross-pivot synthetic elements provide a means to expand the performance of a large range of flexure-based structures including motion stages, manufacturing equipment and optical systems. This could result in better data collection, smaller systems, and less distortion in operation.

42 ENGINEERING↗

Exploring physics of ferroelectric domain walls via Bayesian analysis of atomically resolved STEM data

The physics of ferroelectric domain walls is explored using the Bayesian inference analysis of atomically resolved STEM data. We demonstrate that domain wall profile shapes are ultimately sensitive to the nature of the order parameter in the material, including the functional form of Ginzburg-Landau-Devonshire expansion, and numerical value of the corresponding parameters. The preexisting materials knowledge naturally folds in the Bayesian framework in the form of prior distributions, with the different order parameters forming competing (or hierarchical) models. Here, we explore the physics of the ferroelectric domain walls in BiFeO 3 using this method, and derive the posterior estimates of relevant parameters. More generally, this inference approach both allows learning materials physics from experimental data with associated uncertainty quantification, and establishing guidelines for instrumental development answering questions on what resolution and information limits are necessary for reliable observation of specific physical mechanisms of interest.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A scanning resonator for probing quantum coherent devices

Superconducting resonators with high quality factors are extremely sensitive detectors of the complex impedance of materials and devices coupled to them. This capability has been used to measure losses in multiple different materials and, in the case of circuit quantum electrodynamics (circuit QED), has been used to measure the coherent evolution of multiple different types of qubits. Here, we report on the implementation of a scanning resonator for probing quantum coherent devices. Our scanning setup enables tunable coherent coupling to systems of interest without the need for fabricating on-chip superconducting resonators. We measure the internal quality factor of our resonator sensor in the single-photon regime to be >104 and demonstrate capacitive imaging using our sensor with zeptoFarad sensitivity and micron spatial resolution at milliKelvin temperatures. We then use our setup to characterize the energy spectrum and coherence times of multiple transmon qubits with no on-chip readout circuitry. Our experiments introduce a new tool for using circuit QED to measure existing and proposed qubit platforms.

47 OTHER INSTRUMENTATION↗

Infrared spectroscopy of nearby radio active early-type galaxies - II: spectral atlas

ABSTRACT We present a near-infrared spectroscopic atlas of nearby, bright early-type galaxies with radio emission, containing 163 galaxies observed by the Palomar 200″ TripleSpec instrument, measuring the emission line fluxes for H, He, [Fe ii], and H2 and determined the nuclear excitation mechanisms. By stacking spectra, we deduced the H2 excitation temperature (1957 ± 182 K) and dominant excitation mechanism (thermal and shock heating combined) from the K-band emission line sequence. Stacking also produces an ‘average’ spectrum of absorption features and spectral indices from the literature; the CO12 absorption line index versus J − K colour shows a trend of stronger nuclear activity producing a weaker CO12 index and a redder (flatter) continuum. The correlations between the radio and the emission-line luminosities finds a trend with radio power; however, the large scatter in the upper limits shows that the two are not directly coupled and the duty cycles of SF and AGN activity are not synchronized.

79 ASTRONOMY AND ASTROPHYSICS↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

Studying Interfacial Dark Reactions of Glyoxal and Hydrogen Peroxide Using Vacuum Ultraviolet Single Photon Ionization Mass Spectrometry

Aqueous secondary organic aerosol (aqSOA) formation from volatile and semivolatile organic compounds at the air–liquid interface is considered as an important source of fine particles in the atmosphere. However, due to the lack of in situ detecting techniques, the detailed interfacial reaction mechanism and dynamics still remain uncertain. In this study, synchrotron-based vacuum ultraviolet single-photon ionization mass spectrometry (VUV SPI-MS) was coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI) to investigate glyoxal dark oxidation products at the aqueous surface. Mass spectral analysis and determination of appearance energies (AEs) suggest that the main products of glyoxal dark interfacial aging are carboxylic acid related oligomers. Furthermore, the VUV SPI-MS results were compared and validated against those of in situ liquid time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reaction mechanisms of the dark glyoxal interfacial oxidation, obtained using two different approaches, indicate that differences in ionization and instrument operation principles could contribute to their abilities to detect different oligomers. Therefore, the mechanistic differences revealed between the VUV SPI-MS and ToF-SIMS indicate that more in situ and real-time techniques are needed to investigate the contribution of the air–liquid interfacial reactions leading to aqSOA formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relative Cost-Effectiveness of Electricity and Transportation Policies as a Means to Reduce CO2 Emissions in the United States: A Multi-Model Assessment

Two common energy policy instruments in the United States are tax incentives and technology standards. Although these instruments have been shown to be less cost-effective as a means to reduce CO2 emissions than direct emissions pricing mechanisms, it can be challenging to compare the CO2 emissions reduction costs of such policies across sectors, given the wide range in estimates for any given policy and inconsistencies in how such estimates are constructed across studies. This study addresses this analytical gap by simultaneously comparing the cost-effectiveness of policies across the electricity and transportation sectors using three publicly available US energy system models (EM-NEMS, ReEDS, and GCAM-USA). Four policies are explicitly compared: wind and solar tax credits, a renewable portfolio standard (RPS), a renewable fuel standard (RFS), and an electric vehicle (EV) tax credit. An economy-wide carbon tax is used as a benchmark for cost-effectiveness. Results from this study confirm prior insights about the cost-effectiveness of economy-wide carbon pricing relative to sectoral instruments but also reveal several novel insights about particular sectoral policies. Specifically, this study finds that (1) current electricity tax incentives provide uneven support for wind and solar technologies, (2) despite known inefficiencies, renewable energy policies in the electricity sector are less expensive than earlier estimates due to technology advancement and changes in market conditions, (3) within transportation, an expanded RFS with increasing advanced biofuel targets is more cost-effective than an EV tax credit extension under plausible assumptions, (4) EV incentives lead to a rebound in conventional vehicle fuel economy that further erodes cost-effectiveness, and (5) the change in policy costs over time is not known a priori, but the relative cost ordering among these policies does not depend on the timeframe of analysis. These results are largely robust to the underlying modeling framework, increasing the confidence with which they can be applied to climate policy evaluation.

economics↗

Ultra-pure nickel for structural components of low-radioactivity instruments

The next generation of nuclear and particle physics rare-event search experiments demand structural materials combining ultra-low levels of radioactive contamination with exceptional mechanical strength. Here, this study evaluates chemical vapor deposition (CVD) nickel as a low radioactive background candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates was assayed via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution. These material assays produced measured bulk concentration of 232 Th, 238 U, and nat K at the levels of ~70 ppq, ≲100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 μ m beneath the surface, likely associated with the aluminum growth substrate. Additionally, the CVD Ni underwent tensile testing alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, heat treatment was found to reduce the tensile strength to levels comparable to standard Ni, with implications for high-temperature weld joining methods. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in surface cleaning and weld-joining techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

47 OTHER INSTRUMENTATION↗

Physical origins of the varying performance and unusual transport behaviors among thermoelectric A Mg 2 Sb 2 materials ( A = Ca, Sr, Sm, Yb, and Mg)

Contrary to the similar thermoelectric performance among both AZn 2 Sb 2 and AMg 2 Bi 2 compounds, their isostructural counterparts, AMg 2 Sb 2 , can exhibit thermoelectric figure of merit values that vary by orders of magnitude with different A elements. Here, we reveal physical origins accounting for the significantly differing performance among AMg 2 Sb 2 -based compounds (A = Ca, Sr, Sm, Yb, and Mg) through comprehensive analyses, where it is shown that the dispar- ities in performance at the macroscale essentially originate from the widely varying activation energies that equal amounts of dopant can induce. Meanwhile, a few unusual transport behaviors regarding electrical conductivity, carrier concentration, or lattice thermal con- ductivity among these compounds have been identified, and we also present their rationales in depth. Furthermore, this mechanism-focused study can not only promote further understanding of the complex transport behaviors in condensed matter but be instrumental in rationally tun- ing the physical properties of materials as well.

36 MATERIALS SCIENCE↗

Diagnostics for multiple frequency heating and investigation of underlying processes

The development of new facilities routinely challenges ion source designers to build and operate sources that can achieve ever higher beam intensities and energies. As shown in this work, electron cyclotron resonance ion sources have proven to be extremely capable in meeting these challenges through the production of intense beams of medium and high-charge state ions. As performance boundaries are pushed, source stability becomes an issue as does the technology required to meet the challenge. Multiple frequency heating, the simultaneous use of two or more plasma heating frequencies, is a powerful tool in meeting the simultaneous need of intensity and stability. Relatively straightforward to utilize, the technique has been employed at numerous facilities to increase beam current and achievable charge state while also stabilizing the plasma. Its application has expanded the operational boundaries of existing and next generation sources, demonstrating that these devices have not yet achieved their full operational potential. To better understand the underlying physics, the diagnostics used to probe the source operational boundaries and the plasma properties have become increasingly sophisticated. In concert with detailed modeling, they are beginning to provide insight into the heating mechanism and, with that, the prospect of future advances.

47 OTHER INSTRUMENTATION↗

Liquid Chromatography Mass Spectrometry of eutectic bis(2,2-dinitropropyl) acetal/formal Methodology Development

This report documents the methodology development undergone using a liquid chromatography tandem mass spectrometry (LC-MS/MS) system to investigate the chemical changes produced in the aging process of a eutectic bis( 2,2 - dinitropropyl) acetal/formal nitroplasticizer (NP). Detailed discussion is given to explain why it is essential to develop these methods in LC-MS/MS for analyzing these chemical agents. This report is the second of a series on the use of LC-MS/MS to understand the degradation mechanisms of NP.

36 MATERIALS SCIENCE↗

Sensing Modalities Deployed - Acoustic

Acoustic approaches to OLM are based on analyzing changes in various forms of pressure waves propagating in solids, fluids or gases. These pressure waves can vary in frequency content from infrasound (seismic events) to the megahertz region (acoustic emissions). A wide variety of commercially available pressure or stain sensing devices are used to make acoustic measurements. These sensors differ in the transduction mechanism used to convert the pressure or strain signal to an electrical output, the sensitivity, dynamic range, bandwidth, directional characteristics, and physical size. All acoustic sensors must be integrated with signal conditioning electronics to convert the sensors’ analog output to discrete digital signals that can then be further analyzed for OLM. Ultimately, the sensing properties listed above will be a function of the sensor transduction mechanism, the sensor design and the conditioning electronics.

47 OTHER INSTRUMENTATION↗