Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microfluidic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials

Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of nine materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A sui generis whipping-instability-based self-sequencing multi-monodisperse 2D spray from an anisotropic microfluidic liquid jet device

Well-defined aerosols pave the way for versatile basic and applied research. Here, we demonstrate a unique whipping instability that generates from a high-aspect-ratio microfluidic device resulting in a unique steady-state gas-focused whipping jet (WJ) without any need for electrification. This WJ device emanates a multi-monodisperse whipping spray jet with a two-dimensional (2D) profile. We demonstrate this phenomenon based on various fluidic parameters theoretically and experimentally. The 2D WJ’s unique behavior is derived using analytical fluid dynamics to explain jet diameter, whipping regime, and spreading angle. The phenomenon is further characterized experimentally by measuring the angle with respect to the flow rate, the distances between droplets, the droplet shapes, and the reproducibility of these parameters. We also explain the precise fabrication of such inexpensive devices. Lastly, we highlight these devices’ potential use as sample environments in versatile applications ranging from cryoelectron microscopy over mass spectrometry to drug formulation and structural studies at X-ray free-electron lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Nanocrystal Synthesis: Lessons from 25 Years of Robots, Microfluidics, and Machine Learning

Here, this perspective highlights the evolution of techniques for automating the synthesis of colloidal nanocrystals. Over the past 25 years, microfluidic reactors and robotic workflows have been developed to enhance the reproducibility of nanocrystal synthesis, facilitate rapid screening of reaction conditions, optimize material properties, and perform multistep syntheses of high-quality nanoparticles with complex heterostructures. Modern automated systems are now valued for their ability to generate robust data sets for validating physical models, supporting chemical mechanisms, training machine learning models, and for directing autonomous experimentation. We discuss the early challenges and limitations of these technologies and present key lessons for effectively utilizing automated and ML-guided tools to accelerate nanocrystal discovery for the next 25 years.

Nanocrystals↗

Emergent Behavior at the Calcite–Water Interface during Reactive Transport in a Simple Microfluidic Channel

Geochemical reactive transport processes in natural mineral-fluid systems may produce a wide array of emergent phenomena that are difficult to predict from basic principles and to reproduce in model systems. In this study, we present experimental results obtained from a simple microfluidic system with which we explored the consequences of reacting the calcite (104) cleavage surface with an acidic Pb-bearing solution (pH = 3.5, [Pb] total = 5 mM) as a function of flow rate. This system is relevant to passive remediation systems for Pb-rich acid mine drainage. We observed periodic banding in the amounts of Pb sorption at flow velocities ≥ 926 μm s -1 , where the band spacing was spatially correlated with the amount of calcite dissolution and the development of micropyramidal topography on the calcite (104) surface. The equivalent coverage of Pb deposited in these Pb-rich bands was at least several monolayers per unit cell, yet there was no evidence for precipitation of any secondary Pb phase implying incorporation of Pb within the near-surface calcite lattice. We also observed spatial variations in nucleation and growth of euhedral secondary Pb-carbonate minerals hydrocerusite and cerussite at flow rates ≤ 278 μm s -1 ,. These findings demonstrate potential for exploiting the rich phenomenology afforded by the interplay among transport phenomena and chemical kinetics in experimental systems designed to yield deeper insights into geochemical self-organization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Genetic Selection for Small Molecule Production in Competitive Microfluidic Droplets

Biosensors can be used to screen or select for small molecule production in engineered microbes. However, mutations to the biosensor that interfere with accurate signal transduction are common, producing an excess of false positives. Strategies have been developed to avoid this limitation by physically separating the production pathway and biosensor, but these approaches have only been applied to screens, not selections. In this work, we have developed a novel biosensor-mediated selection strategy using competition between cocultured bacteria. When applied to the biosynthesis of cis,cis-muconate, we show that this strategy yields a selective advantage to producer strains that outweighs the costs of production. By encapsulating the competitive cocultures into microfluidic droplets, we successfully enriched the muconate-producing strains from a large population of control nonproducers. Finally, facile selections for small molecule production will increase testing throughput for engineered microbes and allow for the rapid optimization of novel metabolic pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Reagent-free and portable detection of Bacillus anthracis spores using a microfluidic incubator and smartphone microscope

Rapid, cost-effective bacterial detection systems are needed to respond to potential biothreat events. Here we report the use of smartphone-based microscopy in combination with a simple microfluidic incubation device to detect 5000 Bacillus anthracis spores in 3 hours. This field-deployable approach is compatible with real-time PCR for secondary confirmation.

B. anthracis↗

Mass spectrometry-based monitoring of millisecond protein–ligand binding dynamics using an automated microfluidic platform

Characterizing protein-ligand binding dynamics is crucial for understanding protein function and developing new therapeutic agents. We have developed a novel microfluidic platform that features rapid mixing of protein and ligand solutions, variable incubation times, and on-chip electrospray ionization to perform label-free, solution-based monitoring of protein-ligand binding dynamics. This platform offers many advantages including automated processing, rapid mixing, and low sample consumption.

Environmental Molecular Sciences Laboratory↗

Mechanistic understanding of carbon mineralization in fracture systems using microfluidics

Carbon mineralization in mafic and ultramafic rocks presents an opportunity for permanent carbon storage in the Earth's subsurface. However, due to their lower permeability, pre-existing fracture networks are key for mineralization to occur. Therefore, to fully develop this technology, a mechanistic understanding of the mineralization behavior in fractures with the consideration of hydrodynamic components is required. We use high-pressure microfluidics to investigate key mechanisms influencing dissolution–precipitation in a fracture network. The experiments were conducted in micromodels made of natural rocks with a comb-shaped flow channel to mimic a fracture network. This enabled studying the effect of injection rate on coupled dissolution–precipitation in advection and diffusion-dominated flow paths. We used gypsum carbonation as an analog reaction to allow for realistic experimental time frames due to its rapid reaction kinetics. The experimental work is coupled with high-fidelity numerical simulations to enhance our understanding of the parameters affecting the mineralization reaction. Our results demonstrate the importance of flow rate on the rate and nature of the gypsum carbonation reaction revealing that higher flow rates enable deeper penetration of the mineral precipitation front into the dead-end channels. This is an important finding since for sustained mineralization in a fracture network, precipitation in dead-ends while still allowing for flowing fractures is critical. Detailed characterization of the precipitates showed that lower flow rates led to porous and loose precipitates in the form of aragonite while higher flow rates mimicked supersaturation behavior leading to the formation of calcite. The reactive transport simulations further demonstrated the significance of flow velocity in advection-dominated channels to influence the efficiency of carbon mineralization in diffusion-dominated channels, potentially clogging of dead-end channels. These findings highlight the need for coupling chemical, mechanical, and hydrodynamic processes to evaluate the nature and extent of carbon mineralization in fractured media critical for permanent storage in mafic and ultramafic formations. This research further highlights the need for more investigation in potential subsurface fracture generation techniques to aid carbon mineralization.

25 ENERGY STORAGE↗

Oxygenates production in a microfluidic dielectric barrier discharge device sustained in Ar/CH 4 /O 2

Reforming of methane (CH 4 ) is a process to produce syngas (CO/H 2 ) and other value-added chemicals including oxygenates such as methanol (CH 3 OH). Atmospheric pressure plasmas have the potential to be more energy efficient than traditional reforming methods as value-added chemicals can be synthesized directly in the plasma without requiring an additional step. In this paper, we discuss the results from a computational investigation of the formation of oxygenates by CH 4 oxidation in the presence of Ar, including CH 3 OH and CH 2 O, in a nanosecond pulsed dielectric barrier discharge. The plasma is formed in a microfluidic channel whose small dimensions are ideal for plasma formation at atmospheric pressure. The production and consumption mechanisms of dominant radicals and long-lived species are discussed in detail for the base case conditions of Ar/CH 4 /O 2 = 50/25/25. CH 3 OH is produced primarily by CH 3 O reacting with CH 3 O and CH 3 O 2 reacting with OH, while CH 2 O formation relies on reactions involving CH 3 O and CH 3 . The most abundant oxygenate formed is CO (produced by H abstraction from CHO). However, the greenhouse gas CO 2 is also formed as a by-product. The effects of gas mixture are examined to maximize the CH 3 OH and CH 2 O densities while decreasing the CO 2 density. Increasing the Ar percentage from 0% to 95% decreased the CH 3 OH and CH 2 O densities. At low Ar percentages, this is due to an increase in consumption of CH 3 OH and CH 2 O, while at high Ar percentages (>40% Ar), the production of CH 3 OH and CH 2 O is decreased. However, both CO and CO 2 reached peak densities at 70%–90% Ar. Changing the CH 4 /O 2 ratio while keeping 50% Ar in the discharge led to increased CH 3 OH and CH 2 O production, reaching peak densities at 35%–40% CH 4 . The CO and CO 2 densities decreased beyond 20% CH 4 , indicating that a CH 4 rich discharge is ideal for forming the desired oxygenates.

03 NATURAL GAS↗

Wettability control on multiphase flow in patterned microfluidics

Significance The simultaneous flow of multiple fluid phases through a porous solid occurs in many natural and industrial processes—for example, rainwater infiltrates into soil by displacing air, and carbon dioxide is stored in deep saline aquifers by displacing brine. It has been known for decades that wetting—the affinity of the solid to one of the fluids—can have a strong impact on the flow, but the microscale physics and macroscopic consequences remain poorly understood. Here, we study this in detail by systematically varying the wetting properties of a microfluidic porous medium. Our high-resolution images reveal the fundamental control of wetting on multiphase flow, elucidate the inherently 3D pore-scale mechanisms, and help explain the striking macroscopic displacement patterns that emerge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing multiscale dissolution dynamics in natural rocks through microfluidics and compositional analysis

Mineral dissolution significantly impacts many geological systems. Carbon released by diagenesis, carbon sequestration, and acid injection are examples where geochemical reactions, fluid flow, and solute transport are strongly coupled. The complexity in these systems involves interplay between various mechanisms that operate at timescales ranging from microseconds to years. Current experimental techniques characterize dissolution processes using static images that are acquired with long measurement times and/or low spatial resolution. These limitations prevent direct observation of how dissolution reactions progress within an intact rock with spatially heterogeneous mineralogy and morphology. We utilize microfluidic cells embedded with thin rock samples to visualize dissolution with significant temporal resolution (100 ms) in a large observation window (3 × 3 mm). Here we injected acidic fluid into eight shale samples ranging from 8 to 86 wt % carbonate. The pre- and postreaction microstructures are characterized at the scale of pores (0.1 to 1 µm) and fractures (1 to 1,000 µm). We observe that nonreactive particle exposure, fracture morphology, and loss of rock strength are strongly dependent on both the relative volume of reactive grains and their distribution. Time-resolved images of the rock unveil the spatiotemporal dynamics of dissolution, including two-phase flow effects in real time and illustrate the changes in the fracture interface across the range of compositions. Moreover, the dynamical data provide an approach for characterizing reactivity parameters of natural heterogeneous samples when porous media effects are not negligible. The platform and workflow provide real-time characterization of geochemical reactions and inform various subsurface engineering processes.

58 GEOSCIENCES↗

Microfluidics-based separation of actinium-225 from radium-225 for medical applications

Separation of 225 Ra (t 1/2 = 15 d) from its daughter isotope 225 Ac (t 1/2 = 10 d) is necessary to obtain pure 225 Ac for cancer alpha-therapy. In this study, microscale separation of 225 Ra from its daughter 225 Ac using BioRad AG50X4 cation exchange resin was achieved with good reproducibility across microdevices, and ≥90% purity was achieved for 225 Ac, which is comparable to conventional chromatography. These results indicate the potential for greater use of microfluidics for biomedical radiochemistry. The modularity of the system and its compatibility with different resins allows for quick and easy adaptation to the various needs of a separation campaign.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A user-friendly plug-and-play cyclic olefin copolymer-based microfluidic chip for room-temperature, fixed-target serial crystallography

Over the past two decades, serial X-ray crystallography has enabled the structure determination of a wide range of proteins. With the advent of X-ray free-electron lasers (XFELs), ever-smaller crystals have yielded high-resolution diffraction and structure determination. A crucial need to continue advancement is the efficient delivery of fragile and micrometre-sized crystals to the X-ray beam intersection. This paper presents an improved design of an all-polymer microfluidic `chip' for room-temperature fixed-target serial crystallography that can be tailored to broadly meet the needs of users at either synchrotron or XFEL light sources. The chips are designed to be customized around different types of crystals and offer users a friendly, quick, convenient, ultra-low-cost and robust sample-delivery platform. Compared with the previous iteration of the chip [Gilbile et al. (2021), Lab Chip , 21 , 4831–4845], the new design eliminates cleanroom fabrication. It has a larger imaging area to volume, while maintaining crystal hydration stability for both in situ crystallization or direct crystal slurry loading. Crystals of two model proteins, lysozyme and thaumatin, were used to validate the effectiveness of the design at both synchrotron (lysozyme and thaumatin) and XFEL (lysozyme only) facilities, yielding complete data sets with resolutions of 1.42, 1.48 and 1.70 Å, respectively. Overall, the improved chip design, ease of fabrication and high modifiability create a powerful, all-around sample-delivery tool that structural biologists can quickly adopt, especially in cases of limited sample volume and small, fragile crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Pneumatic Actuated Microfluidic Beads-Trapping Device

The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

42 ENGINEERING↗

Microfluidic molecular assay platform for the detection of miRNAs, mRNAs, proteins, and post-translational modifications at single-cell resolution

In this study, cell signaling is a dynamic and complex process. A typical signaling pathway may begin with activation of cell surface receptors, leading to activation kinase cascade that culminates in induction of mRNA and non-coding miRNA production in the nucleus, followed by modulation of mRNA expression by miRNAs in the cytosol, and end with production of proteins in response to the signaling pathway. Signaling pathways involve proteins, miRNA, and mRNAs, along with various forms of transient post-translational modifications, and detecting each type of signaling molecule requires categorically different sample preparation methods such as Western blotting for proteins, PCR for nucleic acids, and flow cytometry for post-translational modifications. Since we know that cells in populations behave heterogeneously1, especially in the cases of stem cells, cancer, and hematopoiesis, there is need for a new technology that provides capability to detect and quantify multiple categories of signaling molecules in intact single cells to provide a comprehensive view of the cell’s physiological state. In this technical brief, we describe our microfluidic platform with a portfolio of customized molecular assays that can detect nucleic acids, proteins, and post-translational modifications in single intact cells with >95% reduction in reagent requirement in under 8 hours.

42 ENGINEERING↗

Microfluidic-Based sample chips for radioactive solutions

Historical nuclear fuel cycle process sampling techniques required sample volumes ranging in the tens of milliliters. The radiation levels experienced by analytical personnel and equipment, in addition to the waste volumes generated from analysis of these samples, have been significant. These sample volumes also impacted accountability inventories of required analytes during process operations. To mitigate radiation dose and other issues associated with the historically larger sample volumes, a microcapillary sample chip was chosen for further investigation. The ability to obtain microliter volume samples coupled with a remote automated means of sample loading, tracking, and transporting to the analytical instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste volumes. Sample chip testing was completed to determine the accuracy, repeatability, and issues associated with the use of microfluidic sample chips used to supply µL sample volumes of lanthanide analytes dissolved in nitric acid for introduction to an analytical instrument for elemental analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization and application of a high-resolution microfluidic device in atmospheric ice nucleation research and integrated science teaching

Ambient ice-nucleating particles (INPs) represent an important subset of aerosol particles that facilitate heterogeneous formation of ice crystals in the atmosphere, which can impact Earth system and energy. In this work, we developed an affordable high-resolution platform to replicate atmospheric immersion freezing through the unique capabilities of microfluidics to measure INP concentration of known ice nucleation active materials, as well as high-latitude soil samples. The new instrument produced comparable and extended freezing efficiency data for a multitude of samples over the temperature range of -5 to -35 °C as compared to an existing freezing assay within known uncertainties. Moreover, the new assay was integrated into science teaching at a primarily undergraduate and Hispanic-serving institute, contributing to fostering a deeper understanding of ice nucleation processes among college students, instilling their enthusiasm for science, and addressing the critical need for a well-informed citizenry. Student research assistants were involved in both research and pedagogical development processes. Three students from our team visited the Pacific Northwest National Laboratory to help characterize physicochemical properties of our test samples and to test modeling of atmospheric ice nucleation using a box model as well as a global climate model (E3SM) for the regional-scale conditions over the North Slope of Alaska (NSA) and Southern Great Plains (SGP). We also assessed student learning experience via hands-on training, research processes, and development of educational materials. On pre- and post-participation surveys and in exit interviews, students reported personal growth as advancements in breadth of experience, research-related skill sets, and regarding their educational and career goals. They also affirmed that the methods enacted incorporated the NASA Minority University Research and Education Program (MUREP) STEM Engagement Best Practices.

58 GEOSCIENCES↗