Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monodispersity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Impact and explosion crater ejecta, fragment size, and velocity

A model was developed for the mass distribution of fragments that are ejected at a given velocity for impact and explosion craters. The model is semi-empirical in nature and is derived from (1) numerical calculations of cratering and the resultant mass versus ejection velocity, (2) observed ejecta blanket particle size distributions, (3) an empirical relationship between maximum ejecta fragment size and crater diameter and an assumption on the functional form for the distribution of fragements ejected at a given velocity. This model implies that for planetary impacts into competent rock, the distribution of fragments ejected at a given velocity are nearly monodisperse, e.g., 20% of the mass of the ejecta at a given velocity contain fragments having a mass less than 0.1 times a mass of the largest fragment moving at that velocity. Using this model, the largest fragment that can be ejected from asteroids, the moon, Mars, and Earth is calculated as a function of crater diameter. In addition, the internal energy of ejecta versus ejecta velocity is found. The internal energy of fragments having velocities exceeding the escape velocity of the moon will exceed the energy required for incipient melting for solid silicates and thus, constrains the maximum ejected solid fragment size.

Okeefe, J. D.↗

Combustion characteristics in the transition region of liquid fuel sprays

A monodisperse aerosol generator was modified to study ignition requirements, flammability limits, and flame speeds in the transition region. An ignition system was developed and tested. The fabrication of an optical drop sizing system is nearly complete. Preliminary measurements of droplet size effects on the minimum ignition energy for n-heptane sprays performed. Parameteric studies of droplet size effects on minimum ignition energies of various fuels including alcohols are in progress.

Cernansky, N. P.↗

Structure of particle-laden jets - Measurements and predictions

Measurements of mean and fluctuating velocities of both phases as well as particle mass fluxes were completed in turbulent, particle-laden jets containing monodisperse particles with well-defined initial and boundary conditions. The new measurements were used to evaluate a stochastic separated flow model of the process which treated effects of interphase slip and turbulent dispersion using random-walk computations for particle motion. The continuous phase was treated using a modified k-epsilon model allowing for direct contributions of interphase transport to both mean and turbulence properties. The model performed reasonably well over the new data base, with all empirical parameters fixed from earlier work. In contrast, simplified models ignoring either interphase slip or turbulent dispersion yielded poor agreement with the measurements.

Shuen, J.-S.↗

A technique combining the visibility of a Doppler signal with the peak intensity of the pedestal to measure the size and velocity of droplets in a spray

A technique combining the visibility of a Doppler signal and the intensity of the scattered light to measure the size and velocity of particles is presented. It is shown that using only the visibility technique can lead to large errors under many conditions such as dense sprays. It is also shown that this error is considerably reduced and very high resolution is obtained by combining the visibility with the intensity of the scattered light. An instrument was developed using this new concept and measurements were performed in sprays of known characteristics. The results of monodispersed, bimodal and trimodal sprays are reported.

Hess, C. F.↗

Development of the phase/Doppler spray analyzer for liquid drop size and velocity characterizations

The present novel method for spray drop size and velocity measurement is analogous to a laser Doppler velocimeter, obtaining data from the spatial frequency of the interference fringe pattern produced by light scattering. Monodisperse droplet streams were used as a basic test of the theory, as well as of the susceptibility of the method to effects involved in actual application. Either beam intersection angle or detector spacing can be changed to achieve the same result. Polydispersed sprays were also measured.

Bachalo, W. D.↗

Calibrating Droplet Generator for Pressurized Testing Vessel

Device helps to aline laser for droplet-sizing interferometer. Monodispersing Droplet Generator creates uniformly sized droplets. Laser source and receiver of interferometer alined and focused on droplets. MDG mounted in high-pressure flange on tank. Line extensions pass through flange to outside. Flange allows MDG to operate at high injector back pressures used for tests.

Defever, G. J.↗

The structure of dilute combusting sprays

An experimental and theoretical study of drop processes in a turbulent flame is described. The experiments involved a monodisperse (105 and 180 micro m initial diameter) stream of methanol drops injected at the base of a turbulent methane-fueled diffusion flame burning in still air. The following measurements were made: mean and fluctuating phase velocities, mean drop number flux, drop-size distributions and mean gas-phase temperatures. Measurements were compared with predictions of two separated flow models: (1) deterministic separated flow, where drop-turbulence interactions are ignored; and (2) stochastic separated flow, where drop-turbulence interactions are considered using random-walk computations. The stochastic separated flow analysis yielded best agreement with measurements, since it provides for turbulent dispersion of drops which was important for present test conditions (and probably for most combusting sprays as well). Distinguishing the presence or absence of envelope flames around the drops, however, was relatively unimportant for present test conditions, since the drops spent most of their lifetime in fuel-rich regions of the flow where this distinction is irrelevant.

Shuen, J. S.↗

Research study of droplet sizing technology leading to the development of an advanced droplet sizing system

An instrument to measure the size and velocity of droplets was developed. The instrument uses one of two techniques, as appropriate. In the first technique two small laser beams of one color identify the center of a larger laser beam of a different color. This defines a region of almost uniform intensity where the light scattered by the individual droplets can be related to their size. The first technique uses the visibility of a Doppler burst and validates it against the peak intensity of the signal's pedestal. Results are presented for monodisperse, bimodal, trimodal, and polydisperse sprays produced by the Berglund-Liu droplet generator and a pressure nozzle. Size distributions of a given spray obtained using three different size ranges show excellent self-consistency in the overlapping region. Measurements of sprays of known characteristics exhibit errors in the order of 10%. The principles of operation and design criteria of the instrument are discussed in great detail.

Hess, C. F.↗

National Space Transportation Systems Program mission report

The 515-41B National Space Transportation Systems Program Mission Report contains a summary of the major activities and accomplishments of the sixth operational Shuttle flight and fourth flight of the OV-099 vehicle, Challenger. Since this flight was the first to land at Kennedy Space Center, the vehicle was towed directly to the OPF (Orbiter Processing Facility) where preparations for flight STS-41C, scheduled for early April 1984, began immediately. The significant problems that occurred during STS-41B are summarized and a problem tracking list that is a complete list of all problems that occurred during the flight is given. None of the problems will affect the STS 41C flight. The major objectives of flight STS-41B were to successfully deploy the Westar satellite and the Indonesian Communications Satellite-B2 (PALAPA-B2); to evaluate the MMU (Manned Maneuvering Unit) support for EVA (Extravehicular Activities); to exercise the MFR (Manipulator Foot Restraint); to demonstrate a closed loop rendezvous; and to operate the M.R (Monodisperse Latex Reactor), the ACES (Acoustic Containerless Experiment System) and the IEF (Isoelectric Focusing) in cabin experiments; and to obtain photographs with the Cinema 360 Cameras.

Collins, M. A., Jr.↗

Spray characterization with a nonintrusive technique using absolute scattered light

A technique to measure the size and velocity of particles is discussed, and results are presented. In this technique two small laser beams of one color identify the center of a laser beam of a different color. This defines a region of almost uniform intensity where the light scattered by the individual particles can be related to their sizes. A variation of this technique that uses two polarizations of the same color of laser beam is also presented. Results are presented for monodisperse, bimodal, trimodal, and polydisperse sprays produced by the Berglund-Liu droplet generator and a pressure nozzle. Size distributions obtained at three different ranges for the same spray show excellent self-consistency in the overlapping regions. Measurements of a spray of known characteristics exhibit errors in the order of 10 percent.

Hess, C. F.↗

Drop-turbulence interactions in a diffusion flame

A monodisperse stream of methanol drops injected along the axis of a turbulent, methane-fueled diffusion flame burning in still air is studied experimentally and theoretically, in order to determine mean and fluctuating phase velocities, mean drop number flux, drop size distributions, and mean gas phase temperature. Measured values were compared with the predictions of two separated flow analyses, namely deterministic separated flow and stochastic separated flow. The stochastic analysis yielded the best agreement with measurements, due to its providing for the turbulent dispersion of drops.

Shuen, J.-S.↗

Predicting rime ice accretion on airfoils

A method for predicting the droplet impingement and resulting rime ice accretion on airfoils in an incompressible, inviscid flowfield is presented. The governing equations for the water droplet trajectories are described briefly and the appropriate similarity parameters presented. Droplet impingement parameters are described for both monodisperse and arbitrary droplet size distributions. A time-stepping ice accretion process is presented where the flowfield and droplet impingement characteristics are updated periodically to model the time-dependent nature of the process. The method compares well to experimental results of both droplet impingement and rime ice shapes. The time stepping improves the accuracy of the ice shape predictions. Recommendations are given for further research.

Bragg, M. B.↗

Particle size distributions of several commonly used seeding aerosols

During the course of experimentation, no solid particle powder could be found which produced an aerosol with a narrow particle size distribution when fluidization was the only flow process used in producing the aerosol. The complication of adding particle size fractionation processes to the aerosol generation effort appears to be avoidable. In this regard, a simple sonic orifice is found to be effective in reducing the percentage of agglomerates in the several metal oxide powders tested. Marginally beneficial results are obtained for a 0.5/99.5 percent by weight mixture of the flow agent and metal oxide powder. However, agglomeration is observed to be enhanced when the flow agent percentage is increased to 5 percent. Liquid atomization using the Collison nebulizer as well as a version of the Laskin nozzle resulted in polydispersed aerosols with particle size distributions heavily weighted by the small particle end of the size spectrum. The aerosol particle size distributions produced by the vaporization/condensation seeder are closer to the ideal monodispersed aerosol than any of the other aerosols tested. In addition, this seeding approach affords a measure of control over particle size and particle production rate.

Crosswy, F. L.↗

Overview of solid particle LV seeding techniques used at UTRC

Due to the failure of existing seeders to meet the stringent specifications required for benchmark experiments in high pressure, high temperature, rapidly accelerating flowfields, an effort is made to improve an existing solid particle seeder. The goal is to produce a more monodisperse seed from the 0.3 micro alumina powder with more than 99 percent of the particles in the submicron range while maintaining a high seeding rate. Coiled-wire inserts are installed within the ends of the nitrogen injection lines in the primary seeder to produce swirling conical jets to vigorously agitate the seed bed. A secondary swirler, constructed from a 25 cm length of 3.8 cm ID steel pipe having threaded end caps, is connected to the output line of the primary seeder. The seeded nitrogen from the primary seeder is injected tangentially at near sonic velocity into the secondary swirler 9.4 cm above its base. Independently controlled auxiliary nitrogen used to increase the swirl in the secondary chamber is also injected tangentially 2.5 cm below the seeded nitrogen lines. Large seed particles are collected by bleeds in the swirler cap and directed overboard. The remaining seeded nitrogen is collected on the center line of the secondary swirler and ducted to the rig.

Patrick, W. P.↗

Transition region ignition characteristics of n-heptane fuel sprays

Ignition studies were perferred on monodisperse n-heptane sprays at atmospheric pressure over a range of equivalence ratios and droplet diameters. A capacitive discharge spark ignition system was used as the ignition source, providing independent control of spark energy and duration. Preliminary measurements were made to optimize spark duration and spark gap, optimum conditions being those at which the maximum frequency or probability of ignition was observed. The effect of spark duration on ignition frequency for several spark energies was determined for equivalence ratios of 0.5 and 1.0 and initial droplet diameters of 28 and 68 microns. Spark duration had little effect on ignition frequency over the entire 15 to 170 mu s range examined. Spark durations of 70 to 80 mu s were used for all subsequent work. The spark gap was optimized at equivalence ratios of 0.6, 0.8 and 1.0 and initial droplet diameters of 30, 40, 50, 60 and 70 microns by varying the electrode spacing from 0.5 to 5.0 mm while maintaining a constant spark energy. The optimum gap was determined to be 3.0 mm for nearly all conditions.

Danis, A. M.↗

Real-time measurement of sodium chloride in individual aerosol particles by mass spectrometry

The method of particle analysis by mass spectrometry has been applied to the quantitative measurement of sodium chloride in individual particles on a real-time basis. Particles of known masses are individually introduced, in the form of a beam, into a miniature Knudsen cell oven (1600 K). The oven is fabricated from rhenium metal sheet (0.018 mm thick) and is situated in the ion source of a quadrupole mass spectrometer. A particle once inside the oven is trapped and completely volatilized; this overcomes the problem of partial volatilization due to particles bouncing from the filament surface. Individual particles are thermally volatilized and ionized inside the rhenium oven, and produce discrete sodium ion pulses whose intensities are measured with the quadrupole mass spectrometer. An ion pulse width of several milliseconds (4-12 ms) is found for particles in the mass range 1.3 x 10 to the -13th to 5.4 x 10 to the -11th g. The sodium ion intensity is found to be proportional to the particle mass to the 0.86-power. The intensity distribution for monodisperse aerosol particles possesses a geometric standard deviation of 1.09, showing that the method can be used for the determination of the mass distribution function with good resolution in a polydisperse aerosol.

Sinha, M. P.↗

Evaluation of the importance of the relative velocity during evaporation of drops in sprays

The importance of relative velocity past individual drops composing a burning spray with an envelope flame is estimated by applying the Bellan and Cuffel (1983) spray evaporation model to an ambient flow going around the spray without penetrating it. The model assumes a spherical spray composed of monodisperse uniformly distributed droplets which all move at the same speed, and relative gas/spray velocities, and spray radii used were representative of boiler and furnace operations. Numerical calculations indicate that the spray is more prone to ambient flow penetration for leaner mixtures (particularly for n = 1/cu cm), lower initial temperatures of gas phase and droplet, and more dilute spray configurations.

Bellan, J.↗