Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiple Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Robust Positioning in the Presence of Multipath and NLOS GNSS Signals

GNSS signals can be blocked and reflected by nearby objects, such as buildings, walls, and vehicles. They can also be reflected by the ground and by water. These effects are the dominant source of GNSS positioning errors in dense urban environments, though they can have an impact almost anywhere. Non- line-of-sight (NLOS) reception occurs when the direct path from the transmitter to the receiver is blocked and signals are received only via a reflected path. Multipath interference occurs, as the name suggests, when a signal is received via multiple paths. This can be via the direct path and one or more reflected paths, or it can be via multiple reflected paths. As their error characteristics are different, NLOS and multipath interference typically require different mitigation techniques, though some techniques are applicable to both. Antenna design and advanced receiver signal processing techniques can substantially reduce multipath errors. Unless an antenna array is used, NLOS reception has to be detected using the receiver's ranging and carrier-power-to-noise-density ratio (C/N0) measurements and mitigated within the positioning algorithm. Some NLOS mitigation techniques can also be used to combat severe multipath interference. Multipath interference, but not NLOS reception, can also be mitigated by comparing or combining code and carrier measurements, comparing ranging and C/N0 measurements from signals on different frequencies, and analyzing the time evolution of the ranging and C/N0 measurements.

McGraw, Gary A.↗

Theory and implementation of a fast algorithm linear equalizer

The theory and implementation of a multiplication-free linear mean-square error criterion equalizer for data transmission are considered. For many real-time signal processing situations, a large number of multiplications is objectionable. The linear estimation problem on a binary computer is considered where the estimation parameters are constrained to be powers of two and thus all multiplications are replaced by shifts. The optimal solution is obtained from an integer-programming-like problem except that the allowable discrete points are non-integers. The branch-and-bound algorithm is used to obtain the coefficients of the equalization TDL. Specific experimental performance results are given for an equalizer implemented with a 12 bit A/D device and a 8080 microprocessor.

Yan, T. Y.↗

Lidar measurements of cloud extinction coefficient distribution and its forward scattering phase function according to multiply scattered lidar returns

The study of the inversion algorithm for the single scatter lidar equation, for quantitative determination of cloud (or aerosol) optical properties, has received much attention over the last thirty years. Some of the difficulties associated with the solution of this equation are not yet solved. One problem is that a single scatter lidar equation has two unknowns. Because of this, the determination of the far-end boundary value, in the case of Klett's algorithm, is a problem if the atmosphere is optically inhomogeneous. Another difficulty concerns multiple scattering. There is a large error in the extinction distribution solution, in many cases, if only the single scattering component is considered, while neglecting the multiple scattering component. However, the use of multiple scattering in the remote sensing of aerosol or cloud optical properties is promising. In our early study, an inversion method for simultaneous determination of the cloud (or aerosol) Extinction Coefficient Distribution (ECD) and its Forward Scattering Phase Function (FSPF) was proposed according to multiply scattered lidar returns with two fields of view for the receiver. The method is based on a parameterized multiple scatter lidar equation. This paper is devoted to further numerical tests and an experimental study of lidar measurements of cloud ECD and FSPF using this method.

Qiu, Jinhuan↗

System-Wide Error Attribution in Multi-Vehicle Operations: Theoretical Explanation, Implications, and Applications

In multi-vehicle aerial operation contexts, a single or several human operators (m) are responsible for managing multiple uncrewed vehicles (N). This is referred to as the m:N operational paradigm. When automation error occurs during m:N operations, especially if multiple vehicles exhibit automation error, a question is raised: What level of system globality will the error be attributed to? Globality refers to the levels within the conceptual hierarchy of a perceptual object. Significant costs could be incurred if the error is falsely attributed to a higher globality level than it should be (e.g., multiple groups of vehicles as opposed to a single vehicle), and those vehicles are subsequently subject to grounding and evaluation/maintenance. Likewise, it could be problematic if error is falsely attributed to a component (i.e., a lower globality level), resulting in ongoing, unsafe operation of vehicles that should be grounded or evaluated. Thus, to meet required safety standards and facilitate commercial viability, multi-vehicle operators must be capable of appropriately attributing the level of globality of automation error within the system they are responsible for.

Error↗

Improving streamflow estimates through the use of LANDSAT

Estimates of low flow and flood frequency in several southwestern Wisconsin basins were improved by determining land cover from LANDSAT imagery. With the use of estimates of land cover in multiple-regression techniques, the standard error of estimate (SE) for the least annual 7-day low flow for 2- and 10-year recurrence intervals of ungaged sites were lowered by 9% each. The SE of flood frequency in the 'Driftless Area' of Wisconsin for 10-, 50-, and 100-year recurrence intervals were lowered by 14%. Four of nine basin characteristics determined from satellite imagery were significant variables in the multiple-regression techniques, whereas only 1 of the 12 characteristics determined from topographic maps was significant. The percentages of land cover categories in each basin were determined by merging basin boundaries, digitized from quadrangles, with a classified LANDSAT scene. Both the basin boundary X-Y polygon coordinates and the satellite coordinates were converted to latitude-longitude for merging compatibility.

Allord, G. J.↗

Common-Path Wavefront Sensing for Advanced Coronagraphs

Imaging of faint companions around nearby stars is not limited by either intrinsic resolution of a coronagraph/telescope system, nor is it strictly photon limited. Typically, it is both the magnitude and temporal variation of small phase and amplitude errors imparted to the electric field by elements in the optical system which will limit ultimate performance. Adaptive optics systems, particularly those with multiple deformable mirrors, can remove these errors, but they need to be sensed in the final image plane. If the sensing system is before the final image plane, which is typical for most systems, then the non-common path optics between the wavefront sensor and science image plane will lead to un-sensed errors. However, a new generation of high-performance coronagraphs naturally lend themselves to wavefront sensing in the final image plane. These coronagraphs and the wavefront sensing will be discussed, as well as plans for demonstrating this with a high-contrast system on the ground. Such a system will be a key system-level proof for a future space-based coronagraph mission, which will also be discussed.

adaptive optics↗

Prediction of annual soil respiration from its flux at mean annual temperature

Accurately scaling soil respiration (SR, the soil-to-atmosphere flow of CO2) across time and space is important to constrain and understand ecosystem to global scale SR, a major terrestrial carbon flux to the atmosphere. Year-round SR measurements are however expensive and sometimes impossible to perform. Bahn et al. (2010) developed an approach to estimate annual SR (SRannual) from the flux measured at mean soil temperature (SRMAST), but the robustness of this approach needs to be evaluated in diverse ecosystem types and climatic conditions globally. We used a global soil respiration database (SRDB-V4, with 823 SR observations worldwide) to test the capability of SRMAST to predict SRannual. SRMAST estimated using a variety of methods all showed clear relationships with annual SRannual. Two single-rate methods (i.e., using the single SR rate most close to mean annual soil temperature, or the single SR rate most close to mean annual air temperature) showed the most pronounced divergence from the true SRannual, but errors significantly decreased when using multiple SR rates within 1 ? of the mean annual soil temperature to estimate SRMAST. SRannual was most closely correlated with SRMAST estimated via a Q10 relationship, but this method has a potential autocorrelation issue that we explore and discuss. Air temperature data are much more widely available than is soil temperature, and we found that SR at mean annual air temperature (SRMAAT) can be used to predict SRannual as well. This study builds on Bahn et al. (2010) to demonstrate that SR measured at both annual mean soil and air temperature can be used to predict annual SR, with well-quantified errors. This capability could be used to reduce SR measurement frequency required for estimating SRannual and greatly decrease cost, factors that are generally important but especially in lower-income countries and cold, inaccessible regions.

Soil respiration, temperature, modeling↗

Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations

Purpose: The objective of this study was to evaluate and validate the use of the Geant4 application for emission tomography (GATE) Monte Carlo simulation platform for clinical intensity modulated radiotherapy (IMRT) dosimetry studies. Methods: The first step consisted of modeling a 6 MV photon beam linear accelerator (LINAC), with its corresponding validation carried out using percent depth dose evaluation, transverse profiles, tissue phantom ratio, and output factor on water phantom. The IMRT evaluation was performed by comparing simulation and measurements in terms of absolute and relative doses using IMRT dedicated quality assurance phantoms considering seven different patient datasets. Results: Concerning the LINAC simulated model validation tissue phantom ratios at 20 and 10 cm in water TPR{sub 10}{sup 20} obtained from GATE and measurements were 0.672 {+-} 0.063 and 0.675, respectively. In terms of percent depth dose and transverse profiles, error ranges were, respectively: 1.472%{+-} 0.285% and 4.827%{+-} 1.323% for field size of 4 Multiplication-Sign 4, 5 Multiplication-Sign 5, 10 Multiplication-Sign 10, 15 Multiplication-Sign 15, 20 Multiplication-Sign 20, 25 Multiplication-Sign 25, 30 Multiplication-Sign 30, and 40 Multiplication-Sign 40 cm{sup 2}. Most errors were observed at the edge of radiation fields because of higher dose gradient in these areas. Output factors showed good agreement between simulation and measurements with a maximum error of 1.22%. Finally, for IMRT simulations considering seven patient datasets, GATE provided good results with a relative error of 0.43%{+-} 0.25% on absolute dose between simulated and measured beams (measurements at the isocenter, volume 0.125 cm{sup 3}). Planar dose comparisons were also performed using gamma-index analysis. For the whole set of beams considered the mean gamma-index value was 0.497 {+-} 0.152 and 90.8%{+-} 3.6% of the evaluated dose points satisfied the 5%/ 4 mm criterion. Conclusions: These results show that GATE allows reliable simulation of complex beams in radiotherapy after an accurate LINAC modeling is validated. A simple cross-calibration procedure proposed in this work allows obtaining absolute dose values even in complex fields.

60 APPLIED LIFE SCIENCES↗

ON THE ACCURACY OF MEASUREMENTS MADE UPON FILMS PHOTOGRAPHED BY BAKER-NUNN SATELLITE TRACKING CAMERAS

The photographs taken by the Baker-Nunn cameras of the Smithsonian Astrophysical Observatory were formerly measured with Van Biesbroeck goniometers, but are now measured exclusively with Mann two-screw comparators. Instead of measuring point images, we usually have to measure oblong images, either trails or breaks (the latter produced by interruption of the exposure). We can therefore expect that the accuracy of the determination of their positions is more influenced by the personal errors than it is in conventional astrometry. Approximately 800 measurements were made on 34 images of different length, and, from these, the frequency distribution of settings was determined. Then the relationship between this distribution and the length of the image (trail or break) was examined, and the relationship between the "magnitude error" and the length of image was determined. Measurements were made at different angles formed by the trails and the reticle lines, and it was found that the accuracy was not affected by the angle of the setting. Position determinations have been made using reference stars at different distances. On the basis of these results, we can conclude that the accuracy is neither influenced by the distortion of the emulsion nor by the optical distortion within an area of a diameter of S cm (5°.8). We believe that we are justified in using the linear plate constant method, at least within this area. From numerous double and multiple measurements, the following standard errors were determined for a single position.

ASTROMETRY↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sample-Clock Phase-Control Feedback

To demodulate a communication signal, a receiver must recover and synchronize to the symbol timing of a received waveform. In a system that utilizes digital sampling, the fidelity of synchronization is limited by the time between the symbol boundary and closest sample time location. To reduce this error, one typically uses a sample clock in excess of the symbol rate in order to provide multiple samples per symbol, thereby lowering the error limit to a fraction of a symbol time. For systems with a large modulation bandwidth, the required sample clock rate is prohibitive due to current technological barriers and processing complexity. With precise control of the phase of the sample clock, one can sample the received signal at times arbitrarily close to the symbol boundary, thus obviating the need, from a synchronization perspective, for multiple samples per symbol. Sample-clock phase-control feedback was developed for use in the demodulation of an optical communication signal, where multi-GHz modulation bandwidths would require prohibitively large sample clock frequencies for rates in excess of the symbol rate. A custom mixedsignal (RF/digital) offset phase-locked loop circuit was developed to control the phase of the 6.4-GHz clock that samples the photon-counting detector output. The offset phase-locked loop is driven by a feedback mechanism that continuously corrects for variation in the symbol time due to motion between the transmitter and receiver as well as oscillator instability. This innovation will allow significant improvements in receiver throughput; for example, the throughput of a pulse-position modulation (PPM) with 16 slots can increase from 188 Mb/s to 1.5 Gb/s.

Quirk, Kevin J.↗

Constraining estimates of terrestrial carbon uptake: new opportunities using long‐term satellite observations and data assimilation

Summary The response of terrestrial carbon uptake to increasing atmospheric [ CO 2 ], that is the CO 2 fertilization effect ( CFE ), remains a key area of uncertainty in carbon cycle science. Here we provide a perspective on how satellite observations could be better used to understand and constrain CFE . We then highlight data assimilation ( DA ) as an effective way to reconcile different satellite datasets and systematically constrain carbon uptake trends in Earth System Models. As a proof‐of‐concept, we show that joint DA of multiple independent satellite datasets reduced model ensemble error by better constraining unobservable processes and variables, including those directly impacted by CFE . DA of multiple satellite datasets offers a powerful technique that could improve understanding of CFE and enable more accurate forecasts of terrestrial carbon uptake.

Smith, William K.↗

A block matching-based registration algorithm for localization of locally advanced lung tumors

Purpose: To implement and evaluate a block matching-based registration (BMR) algorithm for locally advanced lung tumor localization during image-guided radiotherapy. Methods: Small (1 cm{sup 3}), nonoverlapping image subvolumes (“blocks”) were automatically identified on the planning image to cover the tumor surface using a measure of the local intensity gradient. Blocks were independently and automatically registered to the on-treatment image using a rigid transform. To improve speed and robustness, registrations were performed iteratively from coarse to fine image resolution. At each resolution, all block displacements having a near-maximum similarity score were stored. From this list, a single displacement vector for each block was iteratively selected which maximized the consistency of displacement vectors across immediately neighboring blocks. These selected displacements were regularized using a median filter before proceeding to registrations at finer image resolutions. After evaluating all image resolutions, the global rigid transform of the on-treatment image was computed using a Procrustes analysis, providing the couch shift for patient setup correction. This algorithm was evaluated for 18 locally advanced lung cancer patients, each with 4–7 weekly on-treatment computed tomography scans having physician-delineated gross tumor volumes. Volume overlap (VO) and border displacement errors (BDE) were calculated relative to the nominal physician-identified targets to establish residual error after registration. Results: Implementation of multiresolution registration improved block matching accuracy by 39% compared to registration using only the full resolution images. By also considering multiple potential displacements per block, initial errors were reduced by 65%. Using the final implementation of the BMR algorithm, VO was significantly improved from 77% ± 21% (range: 0%–100%) in the initial bony alignment to 91% ± 8% (range: 56%–100%;p < 0.001). Left-right, anterior-posterior, and superior-inferior systematic BDE were 3.2, 2.4, and 4.4 mm, respectively, with random BDE of 2.4, 2.1, and 2.7 mm. Margins required to include both localization and delineation uncertainties ranged from 5.0 to 11.7 mm, an average of 40% less than required for bony alignment. Conclusions: BMR is a promising approach for automatic lung tumor localization. Further evaluation is warranted to assess the accuracy and robustness of BMR against other potential localization strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variationally Derived Discontinuity Factors for the Asymptotic Homogenized Diffusion Equation

Here in this work, we derive and test variational discontinuity factors (DFs) for the asymptotic homogenized diffusion equation. We begin with a functional for optimally estimating the reactor multiplication factor, then introduce asymptotic expressions for the forward and adjoint angular fluxes, and finally require that all first-order error terms vanish. In this way, the reactor multiplication factor can be calculated with second-order error. The analysis leads to (1) an alternate derivation of the asymptotic homogenized diffusion equation, (2) variational boundary conditions for large periodic systems, and (3) variational DFs to be applied between adjacent periodic regions (e.g., fuel assemblies). Numerical tests show that applying the variational DFs to the asymptotic homogenized diffusion equation yields the most accurate estimates of the reactor multiplication factor compared to other DFs for a wide range of problems. However, the resulting assembly powers are less accurate than those obtained using other DFs for many realistic problems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast-neutron Multiplicity Counter for Passive and Active Measurements of Special Nuclear Material

We developed a fast-neutron multiplicity counter (FNMC) based on organic scintillators (liquid and stilbene). The system is able to detect correlated photon and neutron multiplets emitted by fission reactions. We tested the system both in passive and active operation mode, and present the results of the experiments, both carried out at the Zero Power Physics Reactor of Idaho National Laboratory. The system was operated in coincidence mode (with a gate time of 50 nanoseconds) and two calibration-based approaches were used to estimate the 240Pu effective (240Pueff) and 235U mass of the samples. In passive mode, we assayed two types of plutonium metal plates, i.e. PAHN and PANN, with a 240Pueff mass of 4.7 g and 25.05 g per plate, respectively. The 239Pu mass percentage was 74% for the PAHN and 95% for the PANN series. We measured neutrons emitted in coincidence by several plate assemblies, having an overall 240Pueff mass in the 4.7 g to 500 g range. In active mode, we characterized several uranium samples. We used two AmLi sources (~50000 neutrons emitted per second) to induce fission in the samples. The first six measured samples were certified reference materials (CRM, set 149), having a constant enrichment, i.e. 93.2 wt%, and mass in the range between 0.5 and 4 kg. Additionally, we assayed three CRM-146 samples, with constant total mass of 500 g and an enrichment of 20.1 wt%, 52.8 wt% and 93.2 wt%. In both configurations, the system succeeded in estimating the fissile mass of an unknown sample with a statistical uncertainty lower than 1% (4-minute assay) and 7% (10-minute assay), in passive and active mode, respectively. In passive mode, the statistical uncertainty is lower than the one achieved by standard 3He counters for plutonium metal samples of similar mass. The difference between the estimated and the declared 240Pueff mass, i.e., the bias error, measured by the fast neutron multiplicity counter was consistently lower compared to the bias error of a standard thermal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-257: Output Constancy: Reducing Measurement Variations in a Large Practice Group

Purpose: To standardize output constancy check procedures in a large medical physics practice group covering multiple sites, in order to identify and reduce small systematic errors caused by differences in equipment and the procedures of multiple physicists. Methods: A standardized machine output constancy check for both photons and electrons was instituted within the practice group in 2010. After conducting annual TG-51 measurements in water and adjusting the linac to deliver 1.00 cGy/MU at Dmax, an acrylic phantom (comparable at all sites) and PTW farmer ion chamber are used to obtain monthly output constancy reference readings. From the collected charge reading, measurements of air pressure and temperature, and chamber Ndw and Pelec, a value we call the Kacrylic factor is determined, relating the chamber reading in acrylic to the dose in water with standard set-up conditions. This procedure easily allows for multiple equipment combinations to be used at any site. The Kacrylic factors and output results from all sites and machines are logged monthly in a central database and used to monitor trends in calibration and output. Results: The practice group consists of 19 sites, currently with 34 Varian and 8 Elekta linacs (24 Varian and 5 Elekta linacs in 2010). Over the past three years, the standard deviation of Kacrylic factors measured on all machines decreased by 20% for photons and high energy electrons as systematic errors were found and reduced. Low energy electrons showed very little change in the distribution of Kacrylic values. Small errors in linac beam data were found by investigating outlier Kacrylic values. Conclusion: While the use of acrylic phantoms introduces an additional source of error through small differences in depth and effective depth, the new standardized procedure eliminates potential sources of error from using many different phantoms and results in more consistent output constancy measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Quantifying wildfire drivers and predictability in boreal peatlands using a two-step error-correcting machine learning framework in TeFire v1.0

Abstract. Wildfires are becoming an increasing challenge to the sustainability of boreal peatland (BP) ecosystems and can alter the stability of boreal carbon storage. However, predicting the occurrence of rare and extreme BP fires proves to be challenging, and gaining a quantitative understanding of the factors, both natural and anthropogenic, inducing BP fires remains elusive. Here, we quantified the predictability of BP fires and their primary controlling factors from 1997 to 2015 using a two-step correcting machine learning (ML) framework that combines multiple ML classifiers, regression models, and an error-correcting technique. We found that (1) the adopted oversampling algorithm effectively addressed the unbalanced data and improved the recall rate by 26.88 %–48.62 % when using multiple datasets, and the error-correcting technique tackled the overestimation of fire sizes during fire seasons; (2) nonparametric models outperformed parametric models in predicting fire occurrences, and the random forest machine learning model performed the best, with the area under the receiver operating characteristic curve ranging from 0.83 to 0.93 across multiple fire datasets; and (3) four sets of factor-control simulations consistently indicated the dominant role of temperature, air dryness, and climate extreme (i.e., frost) for boreal peatland fires, overriding the effects of precipitation, wind speed, and human activities. Our findings demonstrate the efficiency and accuracy of ML techniques in predicting rare and extreme fire events and disentangle the primary factors determining BP fires, which are critical for predicting future fire risks under climate change.

54 ENVIRONMENTAL SCIENCES↗

Designing dynamically corrected gates robust to multiple noise sources using geometric space curves

Noise-induced gate errors remain one of the main obstacles to realizing a broad range of quantum information technologies. Dynamical error suppression using carefully designed control schemes is critical for overcoming this challenge. Such schemes must be able to correct against multiple noise sources simultaneously afflicting a qubit to reach error-correction thresholds. Here we present a general framework for designing control fields that simultaneously suppress both noise in the fields themselves as well as transverse dephasing noise. Using the recently developed space curve quantum control formalism, in which robust quantum evolution is mapped to closed geometric curves in a multidimensional Euclidean space, we derive the minimal conditions necessary to guarantee the simultaneous cancellation of both types of noise to leading order. In particular, we find that the cancellation of control field noise requires the derivative of the space curve to have zero-area projections, which is a much more subtle property compared to the closed-curve condition needed to suppress transverse dephasing. We present several techniques for solving both these conditions simultaneously and provide explicit examples of error-resistant control fields. Finally, our work also sheds light on the relation between holonomic evolution and the suppression of control field errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗