Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON FLUENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Materials property changes in ETU-10 graphite due to neutron irradiation at elevated temperatures

Graphite grade ETU-10, from IBIDEN Co., Ltd. Has been irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The irradiation program was developed to provide a preliminary study the irradiation-induced property changes to the dimensions/volume, elastic properties, strength, electrical resistivity, coefficient of thermal expansion, and thermal diffusivity/conductivity over a range of temperatures and neutron exposures that may be relevant for future nuclear reactors. The irradiation envelope covers a range of irradiation temperatures (300°C–900 °C) and fluences (up to 40 × 10 25 n/m 2 [E > 0.1 MeV] or ~30 dpa) that would be relevant for advanced nuclear reactors. Further, the dimensional change was observed to be anisotropic for an isotropic graphite, the specimen dimensions, volume, Young's modulus, shear modulus, and strength all displayed a parabolic fluence dependence, the electrical resistivity had a rapid rise followed by a decrease and a later increase, at high fluence the mean coefficient of thermal expansions was similar for all irradiation temperatures, and thermal conductivity rapidly decreased followed by a continued loss.

36 MATERIALS SCIENCE↗

Potential for neutron and proton transmutation doping of GaN and Ga 2 O 3

As the potential applications of GaN and Ga 2 O 3 are limited by the inadequacy of conventional doping techniques, specifically when uniform selective area p-type doping is required, the potential for transmutation doping of these materials is analyzed. All transmuted element concentrations are reported as a function of time for several common proton and neutron radiation sources, showing that previously published results considered a small subset of the dopants produced. A 40 MeV proton accelerator is identified as the most effective transmutation doping source considered, with a 2.25 × 10 17 protons per cm 2 fluence yielding net concentrations of uncompensated p-type dopants of 7.7 × 10 15 and 8.1 × 1015 cm -3 for GaN and Ga 2 O 3 , respectively. Furthermore, it is shown that high energy proton accelerator spectra are capable of producing dopants required for magnetic and neutron detection applications, although not of the concentrations required for current applications using available irradiation methods.

36 MATERIALS SCIENCE↗

4D evolution of Cr 23 C 6 precipitates in neutron-irradiated and annealed HT-UPS steel observed via synchrotron micro-computed tomography

High-temperature-ultrafine precipitate strengthened (HT-UPS) steel is a potential structural material for advanced nuclear reactors; however, its irradiation response is not well understood. This research provides insight into irradiation-induced effects, such as precipitate evolution mechanisms and four-dimensional morphological evolution, in HT-UPS steel using synchrotron micro-computed tomography. Identical specimens were characterized pre-irradiation and post-irradiation following neutron exposure up to 0.3 displacements per atom at 600 °C. Irradiation effects were also differentiated from the annealing response of precipitates. Following neutron irradiation, the average Cr 23 C 6 precipitate size reduced, affected by the synergy of nucleation and growth, ballistic dissolution, and inverse coarsening, which was observed at fluences an order of magnitude lower than previously observed. Annealing at 600 °C for 32 h increased the average Cr 23 C 6 precipitate size and decreased the phase fraction, attributed to precipitate coarsening. The precipitate morphology evolution and resultant mechanisms can be utilized to parameterize and validate microstructural models simulating radiation damage or annealing.

36 MATERIALS SCIENCE↗

A quantitative study of retention and release of deuterium and tritium during irradiation of y-LiAlO2 pellets

This study reports on the quantification of deuterium in ion-irradiated gamma-LiAlO2 pellets as a function of dose and temperature. The gamma-LiAlO2 pellets were sequentially irradiated with He+ and D2+ ions to the same fluences of 5E16, 1E17 and 2E17 He++D+/cm2 at 188 K. Additional irradiation was performed to 1E17, 2E17 and 4E17 He++D+/cm2 at 573 K. A set of the pellets irradiated at 188 K was shipped and stored at low temperatures from 80 to 132 K and characterized using time-of-flight secondary ion mass spectrometry at ~173 K. The deuterium depth profiles show a Gaussian-like distribution in the low-temperature pellets. The total deuterium retention is found to be directly proportional to the ion fluence. About 27 at.% of the implanted deuterium atoms were released from the pellet irradiated to 2E17 He++D+/cm2 at 188 K during storage at room temperature for ~1 month. Retention of the trapped or bound deuterium during ion irradiation at 573 K increases initially with ion fluence and tends to saturate at a high fluence. The amount of the released deuterium is observed to be quantitatively consistent with that of the released tritium from similar standard pellets during neutron irradiation at 573 K.

Deuterium retention and release, ion irradiation, ↗

Recent Metallic Fuel Data Recovery in FIPD

The Metallic Fuels Irradiation and Physics Database (FIPD) [1] is an organized collection of metallic fuel test pin data (U-xPu-yZr, = 0 ~ 28; y = 2 ~ 10) and documentation available to industry. FIPD mainly contains three types of data: (1) Fuel pin fabrication data, including fuel slug diameter, fuel slug length, cladding diameter, smear density, etc. (2) Fuel pin operation conditions, including axial distributions for power, temperatures, fluences, burnup, and isotopic densities, etc. and (3) Fuel pin post-irradiation examination (PIE) data, including fission gas release and gas chemistry, profilometry, and neutron radiography, etc. The operating conditions for pins with PIE data available in FIPD span significant ranges across key parameters. The fuel peak burnup extends from less than 5% up to 20 at%. The cladding peak temperature varies from about 490°C to 660°C. Finally, the cladding peak DPA shows a wide range from less than 5 to 120. These broad ranges reflect the diverse testing conditions and operational parameters captured in the available PIE data. More detail about FIPD can be found in ref. [2]. The database development is an ongoing effort covering metallic fuel experiments from the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF). As reported in the ref. [3, 4], most of the PIE data generated during the IFR program [5] has been collected, reviewed, processed, and integrated into FIPD. The most recently added PIE data can be found in ref. [4], which shows the collection of over 95% of the PIE data by the time of this paper. The recent improvements to the database are summarized in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Requirements Description of GAMSOR and GAMSRC

This report presents the modeling and simulation capabilities of Argonne National Laboratory’s GAMSOR and GAMSRC code that is used in present reactor analysis activities. These capabilities will then be used to establish the set of verification tasks necessary to verify GAMSOR for use on commercial projects. A similar approach was taken for the PERSENT, REBUS and DIF3D software packages. The GAMSOR program is a modified version of DIF3D used to obtain the coupled neutron gamma flux distributions for a given reactor system. GAMSOR was first developed in the 1980s and its work has progressed in parallel with DIF3D throughout its various development phases. While GAMSOR is compatible with DIF3D-FD and DIF3D-Nodal, DIF3D-VARIANT is most commonly used today and will be the focus of the present verification effort. As covered in [1], GAMSOR was built to provide more accurate heating distributions by explicitly solving for both the gamma and neutron heating distributions. Without this consideration, gamma heat is normally assumed to be deposited locally at the site of gamma production. This is acceptable for modeling some phenomena because the total energy production is preserved, but it can lead to inaccurate approximations of fluence-dependent behaviors such as fuel performance, swelling, cladding embrittlement, radiation induced creep, and power peaking. The outputs from GAMSOR are contained in multiple intermediate and final output files: FIXSRC, VARSRC, GTFLUX, GHFLUX, PWDINT, NPDINT, and GPDINT. DIF3D normally produces a PWDINT file containing power density results, with the assumption that gamma rays are absorbed where they are emitted (i.e., energy deposition is local with no modeled transport). With GAMSOR, neutron power density (NPDINT) and gamma power density (GPDINT) are both produced, with their summed power densities replacing the results in PWDINT for total heating (i.e., recoverable) power density.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measured Reaction Rate Ratios of 235 U, 238 U, 237 Np, 239 Pu Samples in the PFUNS 235 U Prompt Fission Neutron Spectrum Criticality Experiment

The Prompt Fission Uranium Neutron Spectrum experiment, an experiment to reduce uncertainties in the high energy tail of the 235 U prompt fission spectrum, achieved success by performing two separate irradiations measuring approximately 40 different IRDFF-II reactions total using over 20 different foil materials at the National Criticality Experiments Research Center in February 2024. The criticality experiment utilized a set of highly enriched uranium hemispherical shells of increasing diameters with a large void in the center where the samples were located. The focus of this work is the first of two PFUNS irradiations focused on irradiating two of each fission foils, one bare and one cadmium covered, along with metal activation foils containing reaction products with short half-lives, such as indium, iron, and gold along with nickel fluence monitors. This work focuses on presenting the initial reaction rate ratio results of the fission foils from the aforementioned first irradiation to assist in nuclear data validation of those species in a nearly pure 235 U prompt fission neutron spectrum and compares to the Lady Godiva and Flattop-25 historic experiments at the Los Alamos Critical Experiments Facility. Future work will combine fission foil and metallic activation foil reaction rate ratio results from both the first and second higher power irradiation and reaction rates for a final spectral adjustment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Flux Wire Selection on Neutron Spectrum Adjustment

In reactor dosimetry, spectrum unfolding methods are used to assess the energy-dependent neutron flux following the irradiation of flux wires or foils. For some spectrum unfolding methods, an a priori, or initial guess, spectrum is necessary. However, if the a priori spectrum is not representative of the irradiation spectrum experienced by the flux wires, the spectrum unfolding method may fail or create a nonphysical adjusted spectrum. The unfolded spectrum is dependent on flux wire reaction rates, and therefore cross section. As a result, each selection or combination of flux wires will have a different sensitivity to the group-wise fluence difference between the a priori spectrum and the irradiation spectrum. Therefore, a selection of flux wires that are insensitive to errors in the a priori spectrum would be considered robust choices for reactor dosimetry. In this work, flux wire reaction rates are calculated using a simulated neutron spectrum from the High Flux Isotope Reactor (HFIR) and spectrum unfolding methods are used in each flux wire combinations. The flux wire combinations are compared against a traditional flux wire set of Ti, Fe, and Co, with a summary table of the deemed “good” wire combinations that are insensitive to number of a priori neutron energy groups, group-wise difference between the a priori and irradiation, and magnitude of difference.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compositionally-driven surface nanostructuring on refractory compositionally complex alloys under low energy helium bombardment

Additive manufacturing enables user-defined control of the compositional complexity, opening new design spaces for complex concentrated alloys (CCAs). Refractory CCAs may offer enhanced performance in the divertor region of a fusion reactor environment where plasma-facing materials will be subject to high temperatures, low energy He and D particles, and 14 MeV neutrons. In this work, specimens with the nominal composition of NbTaMoTi, NbTaMo, NbTaTi, and NbTa were fabricated via directed energy deposition (DED) then bombarded with 40 eV He ions to a fluence of 2x10 26 m −2 at ∼ 1000 K. Post irradiation, the surface morphology and composition were examined with electron microscopy and x-ray photoelectron spectroscopy to offer information on the spatial distribution of surface nano-structuring. Sub-surface He bubbles driving the nano-structuring were examined with electron microscopy techniques. Analysis indicates the local composition directly influences the He bubble and tendril size, while the region with the highest complexity showed the shortest nano-structuring. Molecular Dynamics simulations complement the experimental results, showing comparable helium bubble growth and migration as a function of compositional complexity. This work demonstrates the compositional dependence of surface nanostructure formation of compositionally complex alloys, important for future design of complex plasma facing materials in fusion reactors.

Complex concentrated alloys↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.↗

Advances in Metallic Fuel Database Development and Data Qualification

The Fuels Irradiation and Physics Database (FIPD [1]) is a comprehensive repository of data and documents related to Uranium-Zirconium based metallic fuel test pins. This database stores operational conditions of these pins, calculated using a suite of Argonne National Laboratory analysis codes developed during the Integral Fast Reactor (IFR) program. Key calculated data include axial distributions of power, temperature, fluence, burnup, and isotopic densities. Additionally, the FIPD holds post-irradiation examination (PIE) data such as fission gas release, gas chemistry measurements, and axial distributions derived from profilometry, gamma scanning, and neutron radiography. Complementing these data is an extensive archive of documents related to various pins and experiments. These include raw PIE records, design details, safety analyses, and operational reports. More detail about FIPD can be found in ref. [2]. The database development is an ongoing effort covering metallic fuel experiments from the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF). The recent improvements to the database and the data QA status are summarized in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Post Irradiation Examination of Pressurized Water Reactor Stainless Steel Internal Components

Internal structural components of pressurized water reactors (PWR), such as baffle former bolts, are subjected to significant neutron irradiation and mechanical stresses at elevated temperatures during plant operation. Over the long operation of the power plant, these conditions lead to potential degradation and reduced load-carrying capacity of these bolts. To understand property degradation more fully, to confirm the results of experimental irradiation programs, and to predict operational lifetime performance of structural materials in internal components, post irradiation examination of harvested materials from operating nuclear reactors is required. In this work, two high fluence 316 stainless steel baffle former bolts were retrieved from a commercial Westinghouse two-loop downflow type PWR and then sectioned for analysis via mechanical testing and microstructural characterization. The irradiation damage fluctuated along the bolt length with damage levels from 15 to 41 displacements per atom with the bolt head receiving approximately twice the neutron damage levels as that of the bolt thread section. Mechanical testing evaluations showed extensive irradiation hardening and a sharp decrease in fracture toughness in all parts of the bolt, though with limited variation along the bolt length. Microstructural characterization using analytical scanning transmission electron microscopy and atom probe tomography showed significant radiation induced precipitation, segregation, and dislocation loop and cavity formation. However, unlike the mechanical behavior, there was considerable variation along the bolt length but opposite of what may be expected, with more precipitation and cavity formation in the bolt thread where the neutron radiation dose is less than in the bolt head where the neutron radiation dose is higher. The cause of this variation is likely due to gradients in temperature, neutron energy spectra, and gamma irradiation.

Lach, Tim↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Search for Ultra-high-energy Photons from Gravitational Wave Sources with the Pierre Auger Observatory

A search for time-directional coincidences of ultra-high-energy (UHE) photons above 10 EeV with gravitational wave (GW) events from the LIGO/Virgo runs O1 to O3 is conducted with the Pierre Auger Observatory. Due to the distinctive properties of photon interactions and to the background expected from hadronic showers, a subset of the most interesting GW events is selected based on their localization quality and distance. Time periods of 1000 s around and 1 day after the GW events are analyzed. No coincidences are observed. Upper limits on the UHE photon fluence from a GW event are derived that are typically at ~7 MeV cm -2 (time period 1000 s) and ~35 MeV cm -2 (time period 1 day). Due to the proximity of the binary neutron star merger GW170817, the energy of the source transferred into UHE photons above 40 EeV is constrained to be less than 20% of its total GW energy. These are the first limits on UHE photons from GW sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing the flux effect on the irradiation embrittlement of reactor pressure vessel steels using machine learning

In-service exposure to high-energy neutrons embrittles reactor pressure vessel (RPV) steels. An increase in the yield stress (Δσ y ) results in a corresponding increase in the brittle to ductile transition temperature (ΔT c ). Most existing models underpredict ΔT c at higher fluence following accelerated irradiations in test reactors. High fluence, up to 10 20 n/cm 2 in some cases, will be reached over extended RPV vessel operation of 80 years, or more, at low service flux. Embrittlement has been extensively studied in accelerated, higher flux test reaction irradiations. However, the use of test reactor data naturally raises the question of flux effects. Here, this study used a machine learning approach trained on a set of hardening data, covering a wide range of flux, fluence, and steel compositions to determine the interactive effects of both irradiation and material variables on Δσ y . The analysis included machine learning-based cross-plots of the variable dependence of Δσ y for six core steels (i.e., CM6, LC, LD, LG, LH, and LI), with controlled differences in their Cu and Ni contents. A primary objective is to evaluate an effective to actual fluence (Φt e /Φt) ratio, as a function of flux, fluence, and steel composition. This is information critical to properly use intermediate flux-high fluence data in calibrating a low flux-high fluence embrittlement model. The predicted Φt e /Φt is reasonably consistent with estimates previously derived from a physics-based solute recombination trap model.

36 MATERIALS SCIENCE↗

Evaluation of HPK n + - p planar pixel sensors for the CMS Phase-2 upgrade

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation campaign of HPK prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

In this work, we report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of were irradiated in steps of roughly 2 up to a fluence of 3. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at °C.

47 OTHER INSTRUMENTATION↗