Search NASA⌕ Search

SEARCH · Search NASA

Results for “NO cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

15 GEOTHERMAL ENERGY↗

Baseline Airfoil Cooling Designs For 5-10MW Gas Turbines

This paper describes conventional cooling technologies that have been identified after a thorough review of public literature as a baseline for more detailed analysis and future testing. This effort is unique because the cooling features (i.e., leading edge, mid-chord, and trailing edge) are integrated together within an airfoil of realistic scale. The engineering models that have been developed to characterize the cooling performance for these baseline configurations will be described. It is believed that the cooling designs described in this paper are representative of gas turbines in the 5-10 MWe size range, but not identical to any commercial product. The present effort to establish a state-of-the-art cooling scheme is a first, and necessary, step in an on-going project to identify and test more advanced cooling concepts for CHP systems that are enabled by additive manufacturing.

Straub, Douglas↗

Baseline Airfoil Cooling Designs For 5-10MW Gas Turbines - Conference Paper

This paper describes conventional cooling technologies that have been identified after a thorough review of public literature as a baseline for more detailed analysis and future testing. This effort is unique because the cooling features (i.e., leading edge, mid-chord, and trailing edge) are integrated together within an airfoil of realistic scale. The engineering models that have been developed to characterize the cooling performance for these baseline configurations will be described. It is believed that the cooling designs described in this paper are representative of gas turbines in the 5-10 MWe size range, but not identical to any commercial product. The present effort to establish a state-of-the-art cooling scheme is a first, and necessary, step in an on-going project to identify and test more advanced cooling concepts for CHP systems that are enabled by additive manufacturing.

Straub, Douglas↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

Chainer, Timothy J.↗

Turbine component and methods of making and cooling a turbine component

A turbine component includes a root and an airfoil extending from the root to a tip opposite the root. The airfoil forms a leading edge and a trailing edge portion extending to a trailing edge. A plurality of axial cooling channels in the trailing edge portion of the airfoil are arranged to permit axial flow of a cooling fluid from an interior of the turbine component at the trailing edge portion to an exterior of the turbine component at the trailing edge portion. A method of making a turbine component includes forming an airfoil having a trailing edge portion with axial cooling channels. The axial cooling channels are arranged to permit axial flow of a cooling fluid from an interior to an exterior of the turbine component at the trailing edge portion. A method of cooling a turbine component is also disclosed.

Dutta, Sandip↗

Adsorption cooling system using metal organic frameworks

An adsorptive cooling system includes two highly adsorptive structures positioned to receive thermal energy from a thermal energy source, each highly adsorptive structure includes a substrate and a metal-organic framework (MOF) coupled to the respective substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions. The adsorptive cooling system includes a cooling unit and a circulation system adapted for circulating the refrigerant from one of the highly adsorptive structures to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant from the cooling unit to the same or other highly adsorptive structure. Each substrate may include a plurality of microchannels, providing ingress and egress paths for a refrigerant, defined by grooves in a surface of the substrate nearest the MOF and/or surfaces of a plurality of microcapillaries of the substrate. The microchannels provide ingress and egress paths for a refrigerant.

Baumann, Theodore F.↗

Two-point and multiple-point spot heating and cooling

Apparatus and methods for producing thermal comfort using two point or multipoint heating or cooling that is applied to portion of a human body part to produce a warm or cool sensation over a larger area than that where the heating or cooling is directly applied. The body is induced to heat or cool itself by adjusting its neutral temperature setpoints. Increased warming perception from two-point, multipoint, and switching point stimulation causes downward adaptation in the neutral skin temperature of the user. Because spot heating and cooling sources operate at higher temperature differences from the skin than do area sources, they create a stronger perceived thermal sensation for the same power consumption. Point heating or cooling, rather than whole-area heating, can result in power savings and cost savings while improving occupant comfort.

Arens, Edward↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Systems and methods for laser diode array having integrated microchannel cooling

The present disclosure relates to a laser diode system. The system may have at least one laser diode emitter having a substrate, at least one laser diode supported on the substrate, and a facet which a laser beam generated by the laser diode is emitted. A cooling subsystem is included which is disposed in contact with the substrate of the laser diode emitter. The cooling subsystem includes a plurality of cooling fins forming a plurality of elongated channels for circulating a cooling fluid therethrough to cool the laser diode emitter. The cooling fluid also flows over the facet of the laser diode emitter.

Kotovsky, Jack↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

Two-tone Doppler cooling of radial two-dimensional crystals in a radio-frequency ion trap

We study the Doppler-cooling of radial two-dimensional (2D) Coulomb crystals of trapped barium ions in a radiofrequency trap. Ions in radial 2D crystals experience micromotion of an amplitude that increases linearly with the distance from the trap center, leading to a position-dependent frequency modulation of laser light in each ion's rest frame. We use two tones of Doppler-cooling laser light separated by approximately 100 MHz to efficiently cool distinct regions in the crystals with differing amplitudes of micromotion. This technique allows us to trap and cool more than 50 ions populating 4 shells in a radial two-dimensional crystal, where with a single tone of Doppler cooling light we are limited to 30 ions in 3 shells. Here, we also individually characterize the micromotion of all ions within the crystals, and use this information to locate the center of the trap and to determine the Matthieu parameters q x and q y .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced cooling tower technology for power plant efficiency increase and operating flexibility

The Final Report describes the results of the work completed during the “Enhanced Cooling Tower Technology for Power Plant Efficiency Increase and Operating Flexibility” project. The objectives of work were to develop and demonstrate the prototype (up to 100 kWth) of an economically viable “all weather” Sub-Dew Point Cooling Tower (SDPCT) with inlet air cooling and dehumidification including testing in laboratory-controlled environment for simulating various ambient conditions. The inlet air is cooled and dehumidified by a Pressure Dehumidifying System (PDHS) installed at the cooling tower inlet.

20 FOSSIL-FUELED POWER PLANTS↗

Providing Thermal Stability for an Exascale Supercomputer: A Case Study of Frontier's Cooling System

High performance computing (HPC) systems frequently produce large dynamic power swings, even under typical operating conditions, that can present a significant challenge for their direct-liquid cooling systems. Further, the primary cooling loops that must remove this waste heat have response times measured in minutes while the underlying HPC component thermal stress is measured in seconds. The per-socket power demand for both compute processing units (CPUs) and graphic processing units ( GPUs) continues to increase with each successive generation while case temperatures are declining. New HPC systems are expected to exacerbate the challenge of these dynamic power swings and the impact on effective and timely cooling systems. This paper describes the cooling and controls system for Oak Ridge National Laboratory’s Frontier Supercomputer, the first sustained exascale system, as a case study for this situation. The cooling and control system for Frontier demonstrates specific success, but with a number of trade-offs and decisions that suggest further design and operating optimizations for the community at large to consider.

42 ENGINEERING↗

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable and Inexpensive Polydimethylsiloxane Sponges for Daytime Radiative Cooling

Radiative cooling is an emerging cooling technology that can passively release heat to the environment. To obtain a subambient cooling effect during the daytime, chemically engineered structural materials are widely explored to simultaneously reject sunlight and preserve strong thermal emission. However, many previously reported fabrication processes involve hazardous chemicals, which can hinder a material’s ability to be mass produced. In order to eliminate the hazardous chemicals used in the fabrication of previous works, this article reports a white polydimethylsiloxane (PDMS) sponge fabricated by a sustainable process using microsugar templates. By substituting the chemicals for sugar, the manufacturing procedure produces zero toxic waste and can also be endlessly recycled via methods widely used in the sugar industry. The obtained porous PDMS exhibits strong visible scattering and thermal emission, resulting in an efficient temperature reduction of 4.6 °C and cooling power of 43 W m –2 under direct solar irradiation. In addition, due to the air-filled voids within the PDMS sponge, its thermal conductivity remains low at 0.06 W (m K) –1 . This unique combination of radiative cooling and thermal insulation properties can efficiently suppress the heat exchange with the solar-heated rooftop or the environment, representing a promising future for new energy-efficient building envelope material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Cooling Rates on Self-Reinforced Polyethylene Composites via Multiscale Experimental Characterizations

This study investigates cooling rate effects on self-reinforced polyethylene composites (PE-SRCs), focusing on macroscopic thermal and mechanical properties, and micro- to sub-micron morphologies. Unlike conventional fiber-reinforced composites (e.g., carbon and glass fiber based), cooling rate effects on SRCs remain less studied. PE-SRCs were fabricated from ultrahigh molecular weight polyethylene (UHMWPE) fabric and high-density polyethylene (HDPE) matrix with cooling rates from 0.76°C/min to 425°C/min. Tensile properties, including modulus (~9.5 GPa), strength (~360 MPa), and ultimate elongation (~6%), showed no significant cooling rate dependence. However, thermal analysis revealed melting temperature of HDPE matrix decreased from ~130°C to ~126.5°C with total crystallinity reducing from 84% to 75%. Wide-angle X-ray scattering confirmed decreasing crystallinity but at lower values (67%–59%), as thermal analysis might overestimate crystallinity. Small-angle X-ray scattering showed long period decreased from 24.3 to 17.4 nm, attributed to thinner lamellae and closer packing, suggesting limited crystal growth and faster nucleation. While cooling rates alter melting point and crystalline structures of HDPE matrix, these changes do not translate to substantial impact on macroscale mechanical properties of PE-SRCs. This insensitivity might be related to low interfacial shear strength at PE/PE interfaces, enabling process optimization while maintaining mechanical performance.

Cooling rate↗

Build plate conduction cooling for thermal management of wire arc additive manufactured components

Wire arc additive manufacturing (WAAM) allows for quick, large component manufacturing with fast deposition rates while leveraging readily available wire feedstock that is significantly cheaper than metal powder. However, the increased deposition rate of this process requires enhanced thermal management as failures can occur due to overheating. A common strategy to mitigate overheating is to dwell, or pause, between individual layers; however, this can significantly increase build times and eliminate the advantage of additive manufacturing being able to manufacture components quickly. To help mitigate this issue, this study explores the use of active cooling to maintain process control and to decrease overall build time. In this work, conductive cooling applied to either the bottom or side of the print substrate was explored. Results from this study showed that bottom build plate active cooling can be used to decrease dwell times by up to 50% and decrease cool-down to room temperature after the building process by up to 75%. Results from this study demonstrate that the use of active cooling strategies for WAAM can be used for better thermal control over the process and should be further investigated.

36 MATERIALS SCIENCE↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗