Avatars in Analytical Gaming

This paper discusses the design and use of anthropomorphic computer characters as nonplayer characters (NPC’s) within analytical games. These new environments allow avatars to play a central role in supporting training and education goals instead of planning the supporting cast role. This new ‘science’ of gaming, driven by high-powered but inexpensive computers, dedicated graphics processors and realistic game engines, enables game developers to create learning and training opportunities on par with expensive real-world training scenarios. However, there needs to be care and attention placed on how avatars are represented and thus perceived. A taxonomy of non-verbal behavior is presented and its application to analytical gaming discussed.

99 GENERAL AND MISCELLANEOUS↗

Design of Low Inductance Busbar for 500 kVA Three-Level ANPC Converter

The adoption of SiC devices in high power applications enables higher switching speed, which requires lower circuit parasitic inductance to reduce the voltage overshoot. This paper presents the design of a busbar for a 500 kVA three-level active neutral point clamped (ANPC) converter. The layout of the busbar is discussed in detail based on the analysis of the multiple commutation loops, magnetic canceling effect, and DC-link capacitor placement. The loop inductance of the busbar is verified with simulation, impedance measurements, and converter experiments. The results match with each other, and the inductances of small and large loop are 6.5 nH and 17.5 nH respectively, which is significantly lower than the busbars of NPC type converters in other references.

Gui, Handong↗

Methodology of Low Inductance Busbar Design for Three-Level Converters

Three-level (3L) converters are more susceptible to parasitics compared with two-level converters because of their complicated structure with multiple switching loops. In this article, the methodology of busbar layout design for 3L converters based on the magnetic cancellation effect is presented. The methodology can fit for 3L converters with symmetric and asymmetric configurations. A detailed design example is provided for a high-power 3L-active neutral point clamped (ANPC) converter, which includes the module selection, busbar layout, and dc-link capacitor placement. The loop inductance of the busbar is verified with simulation, impedance measurements, and converter experiments. Furthermore, the results match with each other, and the inductances of short and long loops are 6.5 and 17.5 nH, respectively, which are significantly lower than the busbars of NPC-type converters in other references.

42 ENGINEERING↗

Experiences and Lessons from Field Demonstration of Grid-forming Inverter in An AC Microgrid

The validation of GFM control strategies through simulation and hardware demonstration is important before their large-scale deployments in the real grid. Considering the importance of testing and validation, several works have explored the GFM inverter’s capability to blackstart a microgrid, synchronize and share loads, and interact with various types of generation sources and loads present in the grid. Herein, this paper complements the existing works by presenting the results and analysis of a field demonstration in an actual AC microgrid. The capability of a three-level neutral point clamped (NPC) GFM inverter equipped with a recursive feedback type of non-linear device level control to operate with PV source on its DC input and off-the-shelf PVGFL inverters and EV chargers of different kinds on the AC side is explored. The analysis and conclusions drawn would inform the readers to make better decisions during the field demonstration process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vulnerability of a VOC-Based Inverter Due to Noise Injection and Its Mitigation

Even though virtual oscillator control (VOC)-based inverters do not communicate with each other, they need to make local measurements for control. The impact of tampering with these measured or sensed signals on the performance of a VOC-based inverter and synchronization of multiple such inverters is an important but open-ended issue. As such, this letter explores the impact of intentional side-channel noise intrusion (SNI) on the synchronization of VOC-based communication-free self-synchronizing inverters (CFSIs). Two different scenarios are investigated via experimental and analytical studies using a half-bridge neutral point clamped (NPC) single-phase CFSI. Furthermore, they address the impact of SNI on the ability of a CFSI to ensure a stable 60-Hz limit cycle and on the parallel operation of two such CFSIs to ensure synchronism to a common 60-Hz load frequency.

42 ENGINEERING↗

Structural Constraints on Autoprocessing of the Human Nucleoporin Nup98

Nucleoporin Nup98, a 98-kDa protein component of the nuclear pore complex, plays an important role in both protein and RNA transport. During its maturation process, Nup98 undergoes post-translational autoproteolysis, which is critical for targeting to the NPC. Here we present high-resolution crystal structures of the C-terminal autoproteolytic domains of Nup98 (2.3 Angstroms for the wild type and 1.9 Angstroms for the S864A precursor), and propose a detailed autoproteolysis mechanism through an N-O acyl shift. Structural constraints are found at the autocleavage site, and could thus provide a driving force for autocleavage at the scissile peptide bond. Such structural constraints appear to be generated, at least in part, by anchoring a conserved phenylalanine side chain into a highly conserved hydrophobic pocket at the catalytic site. Our high-resolution crystal structures also reveal that three highly conserved residues, Tyr866, Gly867, and Leu868, provide most of the interactions between the autoproteolytic domain and the C-terminal tail. These results suggest that Nup98 may represent a new subtype of protein that utilizes autoprocessing to control biogenesis pathways and intracellular translocation.

36 MATERIALS SCIENCE↗

A novel conformity index for intensity modulated radiation therapy plan evaluation

Purpose: Intensity modulated radiation therapy (IMRT) has gained popularity in the treatment of cancers. Manual evaluation of IMRT plans for head-and-neck cancers has been especially challenging necessitating efficient and objective assessment tools. In this work, the authors address this issue by developing a personalized conformity index (CI) for comparison of IMRT plans for head-and-neck cancers and evaluating its plan quality discerning power in comparison with other widely used CIs. Methods: A two-dimensional CI with dose and distance incorporated (CI{sub DD}) was developed using the MATLAB program language, to quantify the planning target volume (PTV) coverage. Valuable information contained in the digital imaging and communication in medicine (DICOM) RT objects were harvested for computation of each of the CI{sub DD} components. Apart from the dose penalty factor, a distance-based exponential function was employed by varying the penalty weight associated with the location of cold spots within the PTV. With the goal of deriving a customized penalty factor, the distances between individual pixel and its nearest PTV boundary was found. Using the exponential function, the impact of distance penalty was substantially larger for cold spots closer to the PTV centroid but petered out quickly wherever they were situated in the vicinity of PTV border. In order to evaluate the CI{sub DD} scoring system, three CT image data sets of nasopharyngeal carcinoma (NPC) patients were collected. Ten IMRT plans with degrading qualities were generated from each dataset and were ranked based on CI{sub DD} and other existing indices. The coefficient of variance was calculated for each dataset to compare the degree of variation. Results: The CI{sub DD} scoring system that considered spatial importance of each voxel within the PTV was successfully developed. The results demonstrated that the CI{sub DD} including four discrete factors could provide accurate rankings of plan quality by examining the relative importance of each cold spot within the PTVs. Apart from the dose penalty factor, a distance-based exponential function was employed taking the specific tumor geometry into account. Compared with other commonly used CIs, the CI{sub DD} resulted in the largest coefficient of variance among the ten IMRT plans for each dataset, indicating that its discerning power was the best among the CIs being compared. Conclusions: The CI{sub DD} scoring system was successfully developed to incorporate patient-specific spatial dose information and provide a geometry-based physical index for comparison of IMRT plans for head-and-neck cancers. By taking individual tumor geometry into account, the superiority of CI{sub DD} in plan discerning power was demonstrated. The use of CI{sub DD} could provide an effective means of benchmarking performance, reducing treatment plan variability, and advancing the quality of current IMRT planning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-422: Correlation Between 2D Passing Rates and 3D Dose Differences for Pretreatment VMAT QA

Purpose: Volumetric modulated arc therapy (VMAT) quality assurance (QA) is typically using QA methods and action levels taken from fixedbeam intensity-modulated radiotherapy (IMRT) QA methods. However, recent studies demonstrated that there is no correlation between the percent gamma passing rate (%GP) and the magnitude of dose discrepancy between the planned dose and the actual delivered dose for IMRT. The purpose of this study is to investigate whether %GP is correlated with clinical dosimetric difference for VMAT. Methods: Twenty nasopharyngeal cancer (NPC) patients treated with dual-arc simultaneous integrated boost VMAT and 20 esophageal cancer patients treated with one-arc VMAT were enrolled in this study. Pretreatment VMAT QA was performed by a 3D diode array ArcCheck. Acceptance criteria of 2%/2mm, 3%/3mm, and 4%/4mm were applied for 2D %GP. Dose values below 10% of the per-measured normalization maximum dose were ignored.Mean DVH values obtained from 3DVH software and TPS were calculated and percentage dose differences were calculated. Statistical correlation between %GP and percent dose difference was studied by using Pearson correlation. Results: The %GP for criteria 2%/2mm, 3%/3mm, and 4%/4mm were 82.33±4.45, 93.47±2.31, 97.13±2.41, respectively. Dose differences calculated from 3DVH and TPS for beam isocenter, mean dose of PTV, maximum dose of PTV, D2 of PTV and D98 of PTV were -1.04±3.24, -0.74±1.71, 2.92±3.62, 0.89±3.29, -1.46±1.97, respectively. No correction were found between %GP and dose differences. Conclusion: There are weak correlations between the 2D %GP and dose differences calculated from 3DVH. The %GP acceptance criteria of 3%/3mm usually applied for pretreatment QA of IMRT and VMAT is not indicating strong clinical correlation with 3D dose difference. 3D dose reconstructions on patient anatomy may be necessary for physicist to predict the accuracy of delivered dose for VMAT QA.

60 APPLIED LIFE SCIENCES↗

SU-E-P-21: Impact of MLC Position Errors On Simultaneous Integrated Boost Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma

Purpose: To investigate the impact of MLC position errors on simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for patients with nasopharyngeal carcinoma. Methods: To compare the dosimetric differences between the simulated plans and the clinical plans, ten patients with locally advanced NPC treated with SIB-IMRT were enrolled in this study. All plans were calculated with an inverse planning system (Pinnacle3, Philips Medical System{sub )}. Random errors −2mm to 2mm{sub )},shift errors{sub (} 2mm,1mm and 0.5mm) and systematic extension/ contraction errors (±2mm, ±1mm and ±0.5mm) of the MLC leaf position were introduced respectively into the original plans to create the simulated plans. Dosimetry factors were compared between the original and the simulated plans. Results: The dosimetric impact of the random and system shift errors of MLC position was insignificant within 2mm, the maximum changes in D95% of PGTV,PTV1,PTV2 were-0.92±0.51%,1.00±0.24% and 0.62±0.17%, the maximum changes in the D0.1cc of spinal cord and brainstem were 1.90±2.80% and −1.78±1.42%, the maximum changes in the Dmean of parotids were1.36±1.23% and −2.25±2.04%.However,the impact of MLC extension or contraction errors was found significant. For 2mm leaf extension errors, the average changes in D95% of PGTV,PTV1,PTV2 were 4.31±0.67%,4.29±0.65% and 4.79±0.82%, the averaged value of the D0.1cc to spinal cord and brainstem were increased by 7.39±5.25% and 6.32±2.28%,the averaged value of the mean dose to left and right parotid were increased by 12.75±2.02%,13.39±2.17% respectively. Conclusion: The dosimetric effect was insignificant for random MLC leaf position errors up to 2mm. There was a high sensitivity to dose distribution for MLC extension or contraction errors.We should pay attention to the anatomic changes in target organs and anatomical structures during the course,individual radiotherapy was recommended to ensure adaptive doses.

60 APPLIED LIFE SCIENCES↗

SU-E-P-44: The Characteristics and Clinical Application of the ArcCHECK for VMAT Verification

Purpose: To evaluate the characteristics and clinical suitability of the ArcCHECK QA system for VMAT verification. Methods: The intrinsic sensitivity,short and long term reproducibility,dose and dose rate dependence,dose per pulsed dependence,field sizes dependence and directional response of the diodes were measured.The results of the diodes were compared with the measurement results of an ionization chamber and calculated results of TPS. Gamma index (3mm distance to agreement and 3% percentage difference ) was used to analyze the dose difference between the calculation and measurement for random selected 211 verified VMAT plans. Results: The ArcCHECK diodes performed well for all tests except directional dependence, which varies from a minimum of −3.9% (seen only when the beam is incident on the diode at 180°) to a maximum of 7.7% (approximately at 255°). Average gamma analysis passing rates with 3mm/3% for 113 NPC,48 cervical cancer and 50 rectal cancer VMAT plans are 93.5%,95.7% and 97.5%, statistical significance has been found between either two of the groups(t=−12.69∼−4.88,all P<0.01). Conclusion: With proposed calibration method,the ArcCHECK QA system is very suitable for VMAT pretreatment verification,the complexity of VMAT plan is the main factor affecting the passing rate.

60 APPLIED LIFE SCIENCES↗

SU-D-BRC-03: Development and Validation of an Online 2D Dose Verification System for Daily Patient Plan Delivery Accuracy Check

Purpose: All plan verification systems for particle therapy are designed to do plan verification before treatment. However, the actual dose distributions during patient treatment are not known. This study develops an online 2D dose verification tool to check the daily dose delivery accuracy. Methods: A Siemens particle treatment system with a modulated scanning spot beam is used in our center. In order to do online dose verification, we made a program to reconstruct the delivered 2D dose distributions based on the daily treatment log files and depth dose distributions. In the log files we can get the focus size, position and particle number for each spot. A gamma analysis is used to compare the reconstructed dose distributions with the dose distributions from the TPS to assess the daily dose delivery accuracy. To verify the dose reconstruction algorithm, we compared the reconstructed dose distributions to dose distributions measured using PTW 729XDR ion chamber matrix for 13 real patient plans. Then we analyzed 100 treatment beams (58 carbon and 42 proton) for prostate, lung, ACC, NPC and chordoma patients. Results: For algorithm verification, the gamma passing rate was 97.95% for the 3%/3mm and 92.36% for the 2%/2mm criteria. For patient treatment analysis,the results were 97.7%±1.1% and 91.7%±2.5% for carbon and 89.9%±4.8% and 79.7%±7.7% for proton using 3%/3mm and 2%/2mm criteria, respectively. The reason for the lower passing rate for the proton beam is that the focus size deviations were larger than for the carbon beam. The average focus size deviations were −14.27% and −6.73% for proton and −5.26% and −0.93% for carbon in the x and y direction respectively. Conclusion: The verification software meets our requirements to check for daily dose delivery discrepancies. Such tools can enhance the current treatment plan and delivery verification processes and improve safety of clinical treatments.

60 APPLIED LIFE SCIENCES↗

SU-F-J-98: Improvement and Evaluation Of Deformation Image Registration On Parotid Glands During Radiation Therapy for Nasopharyngeal Cancer

Purpose: To quantitatively evaluate the strategic innovation and accuracy variation of deformation registration algorithm for parotid glands using the similarity Dice coefficient during the course of radiation therapy (RT) for nasopharyngeal cancer (NPC). Methods: Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed. The data were acquired using tomotherapy (TomoTherapy, Accuray) at the PLA General Hospital. The prescription dose to the primary target was 70Gy in 33 fractions. Two kinds of contours for parotid glands on daily MVCTs were obtained by populating these contours from planning CTs to the daily CTs via rigid-body registration with or without the rotation shifts using the in-house tools and the Adaptive plan software (Adaptive Plan, TomoTherapy), and were edited manually if necessary. The diffeomorphic Demons algorithm developed in the in-house tool was used to propagate the parotid structures from the daily CTs to planning CTs. The differences of the mapped parotid contours in two methods were evaluated using Dice similarity index (DSI). Two-tailed t-test analysis was carried out to compare the DSI changes during the course of RT. Results: For 10 patient plans, the accuracy of deformation image registration (DIR) with the rotation shift was obviously better than those without the rotation shift. The Dice scores of the ipsi- and contra-lateral parotids for with and without the rotation shifts were found to be correlated with each other [0.904±0.031 vs 0.919±0.030 (p<0.001); 0.900±0.031 vs 0.910±0.032 (p<0.001)]. The Dice scores for the parotids have shown the reduction with the changes of parotid volumes during RT. The DSI values between the first and last fraction were 0.932±0.020 vs 0.899±0.030 in 10 patient plans. Conclusion: DIR was successfully improved using the strategic innovation for ART. And the decrease of DIR accuracy has also been found during the delivery of fractionated radiotherapy. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11105225).

60 APPLIED LIFE SCIENCES↗

Factors that will influence oil and gas supply and demand in the 21st century

A recent report published by the National Petroleum Council (NPC) in the United States predicted a 50-60% growth in total global demand for energy by 2030. Because oil, gas, and coal will continue to be the primary energy sources during this time, the energy industry will have to continue increasing the supply of these fuels to meet this increasing demand. Achieving this goal will require the exploitation of both conventional and unconventional reservoirs of oil and gas in (including coalbed methane) an environmentally acceptable manner. Such efforts will, in turn, require advancements in materials science, particularly in the development of materials that can withstand high-pressure, high-temperature, and high-stress conditions.

01 COAL, LIGNITE, AND PEAT↗

NREL Comparison Between Absolute Cavity Pyrgeometers and Pyrgeometers Traceable to World Infrared Standard Group and the InfraRed Integrating Sphere

The comparison of the Absolute Cavity Pyrgeometers (ACPs) Comparison with a PIR Pyrgeometer Traceable to the World Infrared Standard Group (WISG) and a Kipp & Zonen (KZ) pyrgeometer traceable to the InfraRed Integrating Sphere Radiometer (IRIS) was held during the NREL Pyrheliometer Comparison (NPC-2018) from September 24 to October 5, 2018. Data from all instruments was collected during night time clear sky conditions only. The irradiance measured by the ACPs and the PIR pyrgeometer traceable to the WISG were collected every 10 seconds during the ACPs self-calibration and every 30 seconds during the measurement runs. The measurement runs were for two hours while the calibration runs were for 6 minutes. The irradiance measured by the Kipp & Zonen pyrgeometer was collected every 30 seconds. During the comparison the average (av) irradiance difference measured by three ACPs varied from 0.2 W/m 2 to -0.5 W/m 2 , with a standard deviation (sd) from 0.5 W/m 2 to 0.8 W/m 2 . The average irradiance difference measured by the three ACPs minus the irradiance measured by the PIR is 4.3 W/m 2 and sd 4.2 W/m 2 , and that of measured irradiance by the KZ is 2.3 W/m 2 and sd 3.5 W/m 2 .

14 SOLAR ENERGY↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Proposed Path Forward for Transportation of High-Assay Low-Enriched Uranium

Many of the advanced reactors that are being designed will use high-assay low-enriched uranium (HALEU) as the reactor fuel. HALEU is fuel that is enriched between 5% – 20% uranium-235. With the change to higher enriched material, the industry will have new challenges with the development and regulatory approval of enrichment and fuel fabrication facilities and suitable transportation packages to support the economic use of HALEU materials. One area of concern relates to ensure sub-criticality of the material during transportation as identified by the Nuclear Energy Institute (NEI). To evaluate the relevant work, experts, and industry perspectives on HALEU, a workshop was organized to share relevant experience and insights into HALEU transportation, handling, and management. At the August 30 and 31, 2018 workshop, NEI and industry provided the following recommendations to DOE and the national lab complex. 1. DOE and the lab complex should communicate and educate the Nuclear Regulatory Commission (NRC) on criticality issues related to HALEU. 2. Idaho National Laboratory (INL) should support work needed to certify package design for the transportation of HALEU. a. Suggest amending the Certificate of Compliance of an existing package used for the shipment of commercial quantities. b. Suggest DOE provide funding to package designer(s) for analysis and engineering work for a package to be submitted to NRC for approval. 3. INL should provide specific, or a range, of the expected impurities that will be present in recycled naval fuel. 4. In the longer term, DOE and the lab complex should increase the availability of criticality benchmark data to further reduce conservatism in package design. In addition, a couple key takeaways were identified, including: 1. Although the labs can provide additional criticality experiments, industry has enough data to license facilities, overpacks, and cylinders. Validation from additional critical experiments to establish less uncertainty in the benchmarks will be helpful. 2. A collective effort from industry is needed to express consistency on how much information exists or is needed related to criticality. Based on interactions with industry, DOE, and national laboratories, it appears that large-volume transportation of fresh HALEU appears feasible from a criticality perspective. Specifically, an initial review of applicable criticality benchmark experiments identified numerous applicable experiments. However, a more thorough review of a realistic transportation package design is suggested. Therefore, the following next steps are proposed: 1. Evaluate a large volume package with uranium dioxide enriched to 20%. Specifically, the GNF-A NPC package was proposed as a potentially viable option. 2. Based on the results of (1), determine if additional package designs and fuel material should be evaluated. 3. Based on the results of (1), determine if additional criticality experiments would be beneficial to improve the margins for criticality due to uncertainties. 4. Determine DOE transportation needs (packages sizes, shielding requirements, handling/operational requirements, and timing of availability) related to HALEU. 5. Continue to interface with NEI and interested industry companies to determine the appropriate time to engage the NRC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NREL Comparison of Absolute Cavity Pyrgeometers and Pyrgeometers Traceable to the World Infrared Standard Group and the Infrared Integrating Sphere: September 23-October 4, 2019

The comparison of the absolute cavity pyrgeometers (ACPs) with a precision infrared radiometer (PIR) pyrgeometer traceable to the World Infrared Standard Group (WISG) and a Kipp & Zonen (KZ) pyrgeometer traceable to WISG and the InfraRed Integrating Sphere Radiometer (IRIS) was held during the National Renewable Energy Laboratory (NREL) Pyrheliometer Comparison (NPC-2019) from September 23 to October 4, 2019. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs, PIR, and CG4 pyrgeometers collected 30 seconds during the measurement runs. The measurement runs lasted for two hours, while the calibration runs lasted for 6 minutes. During the comparison, the average (av) irradiance difference measured by three ACPs varied from 0.2 W/m 2 to 0.8 W/m 2 , with a standard deviation (sd) from 0.4 W/m 2 to 0.8 W/m 2 . The average irradiance difference measured by the three ACPs minus the irradiance measured by the PIR was 7.1 W/m 2 and sd 1.0 W/m 2 , and the average irradiance difference measured by the KZ traceable to WISG was 8.1 W/m2 and sd 0.9 W/m 2 , and average irradiance difference measured by the KZ traceable to IRIS was 4.0 W/m2 and sd 0.9 W/m 2 .

14 SOLAR ENERGY↗