Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Reflectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Observation of a Giant Goos-Hänchen Shift for Matter Waves

The Goos-Hänchen (GH) shift describes a phenomenon in which a specularly reflected beam is translated along the reflecting surface such that the incident and reflected rays no longer intersect at the surface. Using a neutron spin-echo technique and a specially designed magnetic multilayer mirror, we have measured the relative phase between the reflected up and down neutron spin states in total reflection. The relative GH shift calculated from this phase shows a strong resonant enhancement at a particular incident neutron wave vector, which is due to a waveguiding effect in one of the magnetic layers. Calculations based on the observed phase difference between the neutron states indicate a propagation distance along the waveguide layer of 0.65 mm for the spin-down state, which we identify with the magnitude of the giant GH shift. The existence of a physical GH shift is confirmed by the observation of neutron absorption in the waveguide layer. Here, we propose ways in which our experimental method may be exploited for neutron quantum-enhanced sensing of thin magnetic layers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The crystal acceleration effect for cold neutrons

A new mechanism of neutron acceleration is discussed and studied experimentally in detail for cold neutrons passing through the accelerated perfect crystal with the energies close to the Bragg one. The effect arises due to the following reason. The crystal refraction index (neutron-crystal interaction potential) for neutron in the vicinity of the Bragg resonance sharply depends on the parameter of deviation from the exact Bragg condition, i.e. on the crystal-neutron relative velocity. Therefore the neutrons enter into accelerated crystal with one neutron-crystal interaction potential and exit with the other. Neutron kinetic energy cannot vary inside the crystal due to its homogeneity. So after passage through such a crystal neutrons will be accelerated or decelerated because of the different energy change at the entrance and exit crystal boundaries.

74 ATOMIC AND MOLECULAR PHYSICS↗

Accurate Crystal Structure Refinement of La{sub 3}Ta{sub 0.25}Zr{sub 0.50}Ga{sub 5.25}O{sub 14}

An accurate X-ray diffraction study of a La{sub 3}Ta{sub 0.25}Zr{sub 0.50}Ga{sub 5.25}O{sub 14} single crystal (a = 8.2574(4) A, c = 5.1465(4) A, sp. gr. P321, Z = 1, R/R{sub w} = 0.62/0.57% for 4144 unique reflections and 91 parameters) has been performed with a simultaneous neutron diffraction analysis. Tantalum, zirconium, and gallium atoms are found to occupy the mixed octahedral position (symmetry 32). Gallium atoms and a few zirconium atoms are in the position on axis 2 in the tetrahedron. The tetrahedral position on axis 3 is completely occupied by gallium atoms, while the large polyhedron on axis 2 is occupied by lanthanum atoms. The high resolution and averaging of the results obtained in two independent X-ray experiments with the same sample provided accu- rate structural data, in particular, on the anharmonicity of thermal atomic vibrations (atomic displacements). The X-ray and neutron diffraction data on the atomic displacements are compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The scientific case for concurrent neutron and X-ray scattering and spectroscopy

The interrogation of materials with X-rays or neutrons to determine structure, energetics, and dynamics is fundamental to advancing physical and chemical materials science and enabling innovative material technologies. A persistent challenge in materials development is that progress depends on understanding structure and dynamics across multiple length and time scales in increasingly complex, multicomponent systems featuring interfaces, heterogeneity, and hierarchical organization. Despite rapidly growing demands on materials characterization, current experimental approaches are almost exclusively based on isolated X-ray or neutron scattering and spectroscopy, reflecting a paradigm largely unchanged for decades. To assess the scientific need for a new experimental paradigm, a 3-day workshop sponsored by the U.S. National Science Foundation (NSF) was held at the SpringHill Suites, San Jose, California, from June 2 to 4, 2022. The workshop brought together 70 national and international experts who critically evaluated opportunities enabled by concurrent neutron and X-ray (NeX) scattering, spectroscopy, and imaging experiments. The participants reached a clear consensus that establishing NeX capabilities is crucial for advancing the science of complex materials in the United States. This report illustrates the scientific drivers for NeX experiments through representative examples spanning biomaterials, energy materials, soft matter, nanomaterials, quantum materials, geoscience, and applied materials research. The complementarity of neutrons and X-rays is essential for robust model development and refinement, particularly in multiphase and multicomponent systems. While joint refinement of data from separate experiments is valuable, concurrent measurements uniquely eliminate uncertainties arising from sample evolution, environmental drift, and irreproducibility associated with experiments performed at different locations and times. Realizing NeX capabilities will require the development of new instrumentation, data analysis frameworks, and robust sample environments compatible with both neutron and X-ray probes. Addressing these challenges will enable unambiguous interpretation of complex materials behavior and open new frontiers in materials research.

X-ray↗

ANISOTROPY OF X-RAY BURSTS FROM NEUTRON STARS WITH CONCAVE ACCRETION DISKS

Emission from neutron stars and accretion disks in low-mass X-ray binaries is anisotropic. The non-spherical shape of the disk as well as blocking of the neutron star by the disk make the observed flux dependent on the inclination angle of the disk with respect to the line of sight. This is of importance for the interpretation of thermonuclear X-ray bursts from neutron stars. Because part of the X-ray burst is reflected off the disk, the observed burst flux depends on the anisotropies for both direct emission from the neutron star and reflection off the disk. This influences measurements of source distance, mass accretion rate, and constraints on the neutron star’s equation of state. Previous predictions of the anisotropy factors assumed a geometrically flat disk. Detailed observations of two so-called superbursts allowed for the direct and the reflected burst fluxes to each be measured separately. The reflection fraction was much higher than what the anisotropies of a flat disk can account for. We create numerical models to calculate the anisotropy factors for different disk shapes, including concave disks. We present the anisotropy factors of the direct and reflected burst fluxes separately, as well as the anisotropy of the persistent flux. Reflection fractions substantially larger than unity are produced in the case where the inner accretion disk increases steeply in height, such that part of the star is blocked from view. Such a geometry could possibly be induced by the X-ray burst if X-ray heating causes the inner disk to puff up.

79 ASTRONOMY AND ASTROPHYSICS↗

NEXAFS Microscopy and Resonant Scattering: Composition and Orientation Probed in Real and Reciprocal Space

Near Edge X-ray Absorption Fine Structure (NEXAFS) spectromicroscopy, resonant scattering and resonant reflectivity are specialized, synchrotron radiation based, soft X-ray characterization tools that provide moiety-specific contrast and either real-space imaging at {approx}30 nm spatial resolution, or scattering signals which can be inverted to provide chemically sensitive information at an even higher spatial resolution (<5 nm). These X-ray techniques complement other real and reciprocal space characterization tools such as various microscopies and conventional electron, X-ray and neutron scattering. We provide an overview of these synchrotron based tools, describe their present state-of-the-art and discuss a number of applications to exemplify their unique aspects.

43 PARTICLE ACCELERATORS↗

Exploring the Links between Structural Distortions, Orbital Ordering, and Multipolar Magnetic Ordering in Double Perovskites Containing Re(VI) and Os(VII)

A combination of high-resolution powder diffraction techniques and solid-state NMR has been employed to explore the links between crystal structure, orbital ordering, and magnetism in three isostructural double perovskites containing transition metal ions with a 5d 1 configuration. In Ba 2 ZnReO 6 , both neutron and synchrotron X-ray powder diffraction data reveal a cubic-to-tetragonal transition at 23 K that breaks the degeneracy of the t 2g orbitals and leads to a pattern of orbital ordering that stabilizes magnetic ordering when the sample is cooled below 16 K. Similar behavior is observed in Ba 2 MgReO 6 , with an orbital ordering temperature of 33 K and a magnetic ordering temperature of 18 K. Prior theoretical works suggest that the pattern of orbital order seen in the P42/mnm space group is needed to stabilize the heavily canted antiferromagnetism of these compounds. Unfortunately, powder diffraction data is not sensitive enough to differentiate between the I4/mmm and P42/mnm structural models, as the distortions are too subtle to be unambiguously identified from either neutron or synchrotron X-ray powder diffraction methods. In contrast, both diffraction and 7 Li NMR data indicate that Ba 2 LiOsO 6 retains the cubic structure down to 1.7 K. The antiferromagnetic ground state and lack of any sign of orbital ordering in Ba 2 LiOsO 6 provide compelling evidence that the electronically driven tetragonal distortion seen in Ba2ZnReO6, and Ba2MgReO6 is intimately linked to the magnetic ordering seen in those compounds. The absence of magnetic reflections in high intensity neutron powder diffraction data collected on Ba 2 MgReO 6 strongly suggests ordering of multipolar moments on Re(VI), likely ferro-octupolar ordering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Lead Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 13, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube, and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc, depositing energy in a Si solid-state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Polyethylene Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 19, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc depositing energy in a Si solid state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron skin thickness and neutron star equations of state: a strong relationship

A density dependent hadronic model and a common parametrization of the non-linear Walecka model are used to obtain the lead neutron skin thickness through its proton and neutron density profiles. The neutron skin thickness is known to reflect the equation of state properties. A direct correlation between the neutron skin thickness and the slope of the symmetry energy is found.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real time reciprocal space mapping of nano-islands induced by quantum confinment.

The effects of quantum confinement have been observed pronouncedly in the island morphology of Pb thin films. The evolution of these nano-islands on Si (111)-(7 x 7) and sapphire (001) surfaces has been studied with a new X-ray diffraction method. A charge-coupled device (CCD) camera was used to collect two- and three-dimensional (2-D and 3-D, respectively) maps of the surface X-ray diffraction in real time. Large ranges of the reflectivity curves, with rocking curves at every point on the reflectivity curves, could be measured continuously in a relatively short amount of time. The abundance of information from 2-D k-space maps reveals clear changes in the growth modes of these thin Pb films. With the 3-D extension of this method, it was possible to observe the ordering of the islands. The islands maintain a nearly uniform interisland distance but lack any angular correlation. The interisland ordering is correlated well with the development of 'magic' island heights caused by quantum confinement.

36 MATERIALS SCIENCE↗

Evaluation of the Crystalline Quality of Strongly Curved 3C-SiC/Si Epiwafers Through X-Ray Diffraction Analyses

The value of the full width at half maximum of the rocking curve of symmetric 3C SiC reflection, often considered as the ''quality indicator'' of the epitaxial film, is in fact a convolution of several contributions, among which the curvature related part may play a dominant role. Thus, a precise determination of the curvature related broadening is necessary to extract the information on the film quality from the rocking curve. In this paper we demonstrate experimentally the coexistence of two independent curvature related broadening effects. We also propose an analytical model that describes quantitatively both effects.

36 MATERIALS SCIENCE↗

Woodgrain defect on tinned steel Flandres foil

Tin electrocoated steel strip, also referred to as Flandres foil, is largely used for manufacturing food containers. Tinplates must have good corrosion resistance, workability, weldability, as well as a bright appearance. The woodgrain defect, a not yet fully understood defect that occurs on tinplates and accounts for their high scrap rate, consists of alternate bands of bright/dull reflectivity and resembles longitudinally cut wood. Observations of the woodgrain defect by scanning electron microscopy showed that the molten tin spreads irregularly during both the melting and solidification stages. X-ray diffraction analyses showed that the metallic tin tended to crystallize in the (200) direction for coupons with and without the woodgrain defect. Nevertheless, the preferential orientation degree decreased for coupons with the woodgrain defect. The rocking curves, also known as omega-scan, showed that the tin grains were uniformly aligned parallel to the strip surface for coupons with no defects, whereas for tinplates with woodgrain, the tin grains were not uniformly oriented, probably due to the misalignment of the grains in relation to the surface. - Graphical abstract: The woodgrain defect occurs on Flandres tinplates and consists in the formation of alternate bands of different reflectivity (bright/dull), which looks like longitudinally cut wood. X-ray diffractometry showed that the typical bright surface of tinplate is associated to the uniform distribution of aligned (200) Sn grains, whereas in tinplate with the woodgrain defect, the Sn grains were not uniformly oriented, due to the misalignment of the (200) Sn planes relative to the surface. Research highlights: {yields} The bright surface of tinplate is associated to the uniform distribution of aligned (200) Sn grains. {yields} The woodgrain defect on tinplate consists in alternate bands of bright/dull appearance. {yields} In tinplate with the woodgrain defect, the Sn grains were not uniformly oriented, due to the misalignment of the (200) Sn planes relative to the surface.

36 MATERIALS SCIENCE↗

Processing of X-ray snapshots from crystals in random orientations

A new method for the treatment of partial reflections from X-ray snapshots is implemented in the program package nXDS, which yields intensity data of almost the same quality as those obtained by the classical rotation method. A functional expression is introduced that relates scattered X-ray intensities from a still or a rotation snapshot to the corresponding structure-factor amplitudes. The new approach was implemented in the program nXDS for processing monochromatic diffraction images recorded by a multi-segment detector where each exposure could come from a different crystal. For images containing indexable spots, the intensities of the expected reflections and their variances are obtained by profile fitting after mapping the contributing pixel contents to the Ewald sphere. The varying intensity decline owing to the angular distance of the reflection from the surface of the Ewald sphere is estimated using a Gaussian rocking curve. This decline is dubbed ‘Ewald offset correction’, which is well defined even for still images. Together with an image-scaling factor and other corrections, an explicit expression is defined that predicts each recorded intensity from its corresponding structure-factor amplitude. All diffraction parameters, scaling and correction factors are improved by post-refinement. The ambiguous case of a lower point group than the lattice symmetry is resolved by a method reminiscent of the technique of ‘selective breeding’. It selects the indexing alternative for each image that yields, on average, the highest correlation with intensities from all other images. Processing a test set of rotation images by XDS and treating the same images by nXDS as snapshots of crystals in random orientations yields data of comparable quality, clearly indicating an anomalous signal from Se atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

General guide concepts for compact, high-brilliance neutron moderators

The trend in neutron sciences is toward integrating compact, high-brightness moderators into new or upgraded facilities. Transporting neutrons from the source to the sample position with a phase-space distribution tailored to specific requirements is crucial to leverage high source brilliance. Here we have investigated four guide concepts using Monte Carlo ray tracing simulations: Montel beamline with nested Kirkpatrick–Baez mirrors, curved-tapered beamline with a bender and straight sections, straight-elliptical beamline, and curved-elliptical beamline. The straight-elliptical (curved-elliptical) beamline features two half-ellipse guides connected by a straight (non-straight) guide section. The neutron transport efficiency and phase space homogeneity have been quantitatively compared. Our results show that the straight-elliptical beamline performs best because of few neutron bounces on the guide surface with small reflection angles, minimizing flux loss. The Montel beamline provides the best spatial confinement of neutrons within the desired region; however, there is a high thermal-neutron loss due to large reflection angles. The curved-tapered beamline suffers from significant flux loss due to high bounces, and it shows a non-uniform angular distribution related to broad ranges of bounces and reflection angles. The non-straight guide section of the curved-elliptical beamline increases the phase space inhomogeneity, leading to a spatially non-uniform beam profile. The results apply to general neutron instruments that require transporting thermal and cold neutrons from a compact, high-brilliance moderator to the sample location with a moderate phase-space volume.

47 OTHER INSTRUMENTATION↗

RHEGAL: Resistive heating gas enclosure loadframe for in situ neutron scattering

In situ neutron scattering is a powerful tool to reveal materials atomic structural response such as phase transformation, lattice straining, and texture under external stimuli. The advent of a high flux neutron source such as the Spallation Neutron Source (SNS) allows fast measurement in even non-equilibrium conditions, i.e., phase transformation in steels. However, the commercial fast heating apparatus such as commercial physical simulation equipment is not designed for in situ neutron scattering, which limits its application to in situ materials research by using neutrons. Here we present a resistive heating gas enclosure loadframe (RHEGAL) for non-equilibrium phase transformation studies by using in situ neutron scattering, which takes the advantage of high flux neutron sources like SNS. RHEGAL enables fast resistive heating of metal samples to 1200 °C at a rate up to 60 °C/s in an inert atmosphere. It provides both horizontal and vertical positions for scattering optimization. The mechanical loading capability also allows in situ high temperature tension above the oxidation temperature limit. The optimized translucent neutron scattering window by silicon allows both reflection and transmission measurements, making this equipment applicable for neutron diffraction, small angle scattering, and imaging. Furthermore, to demonstrate the fast heating capability, the phase transformations of an example of advanced high strength steel heated at 3 °C/s and 30 °C/s were measured with the VULCAN engineering diffractometer, and the different phase transformation kinetics by neutron diffraction were presented.

47 OTHER INSTRUMENTATION↗

Stability Measurements for Alignment of the NIF Neutron Imaging System Pinhole Array

The alignment system for the National Ignition Facility's neutron imaging system has been commissioned and measurements of the relative stability of the 90-315 DIM, the front and the back of the neutron imaging pinhole array and an exploding pusher target have been made using the 90-135 and the 90-258 opposite port alignment systems. Additionally, a laser beam shot from the neutron-imaging Annex and reflected from a mirror at the back of the pinhole array was used to monitor the pointing of the pinhole. Over a twelve hour period, the relative stability of these parts was found to be within {approx} {+-}18 {micro}m rms even when using manual methods for tracking the position of the objects. For highly visible features, use of basic particle tracking techniques found that the front of the pinhole array was stable relative to the 90-135 opposite port alignment camera to within {+-}3.4 {micro}m rms. Reregistration, however, of the opposite port alignment systems themselves using the target alignment sensor was found to change the expected position of target chamber center by up to 194 {micro}m.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗