Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Monte-Carlo Method of Calculating Weakly Coupled Systems Using the PRIZMA-DSP Code

A Monte Carlo method implemented in the PRIZMA-DSP code to calculate multiplying systems, including weakly coupled systems, is described. In the code, the basis of the method is a sequential calculation of a prescribed chain of active generations, which is described by, first and foremost, the dominant ratio of the system. The fission points of the running generation serve as a source for constructing neutron trajectories, new fission points arising on a trajectory are transmitted unchanged to calculate the next generation, and so on. In the calculation of the active generation, K{sub eff} and made-to-order linear-fractional functions are evaluated. In order for the distribution to become established, a passive calculation with prescribed chain length is made before the active calculation. In addition, after the calculation of each generation the operation of random mixing of the entire set of fission points and their distribution over the nuclei is performed in order to obtain a uniform distribution. At the start of the calculation, a special rejection procedure performs a pre-set number of preliminary computational iterations so that an arbitrary zeroth distribution over all nuclei goes to a distribution obtained via a characteristic function.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calculation of Activated Water Radiation Maps in ITER

ITER is a nuclear machine designed for 500 MW DT fusion power emitting an immense power in the form of 14 MeV neutrons (∼400 MW). These high energy neutrons activate the water used to cool the first wall, blanket modules, vacuum vessel etc. The principal isotopes generated in water coolant are {sup 16}N and {sup 17}'N from oxygen isotopes. Both these radioisotopes are generated by neutrons having energy more than 10 MeV. Even though these isotopes are short-lived (T{sub 1/2} {sup 16}N: 7.13 s and T{sub 1/2} {sup 17}N: 4.17 s) they generate significant radiation fields outside the bio-shield due to high neutron fluence at irradiation end, large volume of the coolant, high speed of the coolant, emission of high energy nuclear radiations from {sup 16}N (gammas) and {sup 17}N (neutrons). Therefore, radiation fields generated by the activated water need to be calculated in order to design the plant systems to withstand radiation dosage and for the safety of the workers as per regulatory limits. This paper presents the calculation methodology of the {sup 16}N and {sup 17}N sources in the coolant lines, manifolds, heat exchangers etc., which are distributed over the wide area outside the bio-shield. The calculated source is modelled in the MCNP building model which is approximately 120 m x 80 m x 50 m. The building model has significant amount of shielding walls (∼3 m thickness). This presents a challenge to get the sufficient statistics everywhere in the global model. The radiation transport is performed with the code MCNP to calculate the radiation fields (biological dose rate, absorbed dose in silicon, 1 MeV silicon equivalent fluence, neutron flux) throughout the tokamak complex.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and construction of pulsed neutron diagnostic system for plasma focus device (SBUPF1)

In this paper, two designs of pulsed neutron counter structure are introduced. To increase the activation counter efficiency, BC-400 plastic scintillator plates along with silver foils are utilized. Rectangular cubic and cylindrical geometries for activation counter cell are modeled using MCNP4C code. Eventually, an optimum length of 14 cm is calculated for the detector cell and optimum numbers of 20 silver foils for rectangular cubic geometry and ten foils for cylindrical geometry have been acquired. Due to the high cost of cutting, polishing of plastics, and etc., the rectangular cubic design is found to be more economical than the other design. In order to examine the functionality and ensure the detector output and corresponding designing, neutron yield of a 2.48 kJ plasma focus device (SBUPF1) in 8 mbar pressure with removal source method for calibration was measured (3.71{+-}0.32)x10{sup 7} neutrons per shot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of an RPM based on Gd-lined plastic scintillator for neutron and gamma detection [ANIMMA--2015-IO-372]

A Radiation Portal Monitor (RPM) was developed by the Istituto Nazionale di Fisica Nucleare (INFN) and Ansaldo Nucleare (ANN) within the FP7 SCINTILLA European project. The system was designed to detect both gamma and neutron radiation with a single technology. It is conceived to monitor vehicle and cargo containers in transits across borders or ports, to find radioactive elements and to avoid illegal trafficking of strategic nuclear materials. The system is based on a {sup 3}He-free neutron detection technology using plastic scintillators coupled to Gadolinium to detect and discriminate gamma from neutron signals. During the 3 years of the SCINTILLA project the construction and test of the first two prototypes drove the definition of the final layout of a full RPM system consisting of two twin pillars as a portal for vehicle and cargo container scan. A custom System Control Software (SCS) manages the electronics of the RPM, the ancillary devices and the data analysis. The combination of the detector layout and of the software functionalities enables both to distinguish neutrons and gammas and to identify the energy range of a detected gamma source. The system was initially characterized via static tests with gamma and neutron sources in the INFN laboratory. These measurements were used to calibrate the detector, evaluate the response of the single pillars as well as of the full system, and optimize the RPM configuration and discrimination algorithm. During this phase, specific tests were performed to study the stability over time of the system, monitoring the measured the neutron and gamma count rates over periods of several weeks. The results allow us to demonstrate the reliability and robustness of the RPM. In a second time the RPM performance was studied via dynamic tests performed during the SCINTILLA test and benchmark campaigns. These measurements took place in the JRC ITRAP+10 facility at Ispra (Varese-Italy). The laboratory is equipped with an experimental set-up for dynamic tests of multiple systems according to international standards. The performed measurements utilized radioactive sources with activities selected according to ANSI and IEC standards to test the detector alarm performances in terms of gamma and neutron response, sensitivity to high gamma fields, sensitivity to moderated neutron sources as well as false alarm rates (FAR). In addition, the RPM was tested in challenging configurations exceeding the requirements set by international standards to determine the real limits of the system. The results obtained during these campaigns demonstrated that the system detection efficiency is not only compliant to international standards for its category, but often exceeds them, demonstrating the validity of the chosen technology and of the implemented layout. The positive performance also showed the effectiveness of the SCS and of its functionalities. To further demonstrate the system capabilities, a test in a real-life environment of the RPM is planned to happen in a near future by installing the detectors in a seaport. In this presentation I will give an overview of the RPM characteristics, of its performances as determined in the test campaign mentioned above and of future plans, to demonstrate how this technology can be an effective choice for the realization of {sup 3}He-free RPM detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dry etching techniques for active devices based on hexagonal boron nitride epilayers

Hexagonal boron nitride (hBN) has emerged as a fundamentally and technologically important material system owing to its unique physical properties including layered structure, wide energy bandgap, large optical absorption, and neutron capture cross section. As for any materials under development, it is necessary to establish device processing techniques to realize active devices based on hBN. The authors report on the advancements in dry etching techniques for active devices based on hBN epilayers via inductively coupled plasma (ICP). The effect of ICP radio frequency (RF) power on the etch rate and vertical side wall profile was studied. The etching depth and angle with respect to the surface were measured using atomic force microscopy showing that an etching rate ∼1.25 μm/min and etching angles >80° were obtained. Profilometer data and scanning electron microscope images confirmed these results. This work demonstrates that SF{sub 6} is very suitable for etching hBN epilayers in RF plasma environments and can serve as a guide for future hBN device processing.

36 MATERIALS SCIENCE↗

Prompt Gamma Neutron Activation Analysis of Niobium for Characterization of Light Interstitials

High purity niobium metal is used in the construction of superconducting radio frequency (SRF) cavities in superconducting particle accelerators. The Spallation Neutron Source at Oak Ridge National Laboratory is an example of an SRF linear accelerator (LINAC) that requires this high purity niobium material. For the SRF cavities to function well, it is necessary that the cavity wall have a high thermal conductivity so that the radio frequency (RF) power can be dissipated into the liquid helium coolant. For a high thermal conductivity of the niobium metal to be achieved, it is required to have extremely low levels of impurities. The current industry standard for determining the quality of the high purity niobium material is the residual resistivity ratio (RRR) technique. In this technique, the temperature dependency of a niobium metal sample is determined at temperatures near that of liquid helium in order to establish where the superconducting jump occurs. With this method, it is possible to find the general level of impurity of the metal sample, but not the specific elements that are contributing to the impurity. The impurities that are of particular interest to manufacturers of niobium for SRF use are tantalum and light interstitials, such as hydrogen, carbon, nitrogen, and oxygen. In this research, we focus on determining the analytical sensitivity of the detector system and characterizing the light interstitial content in high purity niobium metal through the use of Prompt Gamma Neutron Activation Analysis (PGNAA). PGNAA is an analytical technique that can be utilized to determine the concentration of elemental components in a wide variety of materials with high precision and reproducibility. In this process, neutrons bombard a sample material, causing the emission of gamma rays from the sample. Each element emits a unique spectrum of gamma radiation, which allows for identification of the elements present in the sample. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AFIP-7 Tomography – 2013 Status Report

This project seeks to assess the geometric stability of the U-Mo monolithic fuel system by evaluating the radiation-induced changes in the AFIP-7 experiment device. Neutron radiography and computed tomography (CT) provide valuable information about the post-irradiation condition of the fuel specimen. Tomographic reconstructions of the AFIP-7 fuel element will be analyzed to assess the geometric condition of the element after irradiation and provide information regarding the condition of the fuel, including gross geometric defects, bowing, twist, plate buckling, cracks, and other defects. The INL, in collaboration with Oregon State University (OSU), Missouri University of Science and Technology (Missouri S&T), and Real Time Tomography, is developing advanced neutron detector systems and tomographic reconstruction techniques to evaluate the AFIP-7 fuel element. Neutron computed tomography using the current neutron radiography technique available at the Neutron Radiography reactor (NRAD) is impractical due to the long time and high cost to produce a set of images for tomographic reconstruction. Advanced neutron radiography systems such as the micro-channel plate (MCP) detector and neutron computed radiography (CR) may reduce the time and cost of acquiring images for neutron CT. The MCP detector system tested at OSU and Missouri S&T provides neutron radiographs and has lower gamma sensitivity compared to other digital acquisition image systems. However, some significant, but not prohibitive, challenges must be overcome to make its use for imaging nuclear fuel more practical. Images taken with the MCP require significant image processing to reduce distortions and correct for the dynamic detector response. Also, the small active area of the detector (~30 mm diameter) requires the collection and combination of several images of a specimen, which may become time-consuming. The MCP is tested in low gamma dose environments, but should also be tested in the gamma field at the INL. In addition to the MCP detector system, the INL is developing neutron computed radiography (CR), which uses the same foil transfer method currently employed at the NRAD, but replaces the film with a photostimulable storage phosphor imaging plate that is sensitive to the decay radiation from the activated transfer foils. Preliminary tests show that neutron CR provides lower, but comparable spatial resolution properties to film radiography images using the transfer method technique already employed at the NRAD. However, there are many factors that affect the spatial resolution of neutron CR that can be adjusted and possibly provide spatial resolution properties that exceed film radiography. The reduction in cost of neutron CR may be significant, which would make neutron imaging more appealing to programs that would benefit from this rare and valuable capability. Because transfer method neutron radiography is expensive and time-consuming, acquisition of a full set of radiographs for tomographic reconstruction is impractical. The INL is developing tomographic reconstruction techniques that require only a small set of radiographs of the AFIP-7 fuel element. These tomosynthesis techniques are tested using archived radiographs of TREAT experiments for CT as a proof of principle. These same techniques are applied to radiographs taken with an MCP detector of a mock-up of the AFIP-7 geometry. Acquisition angle should at least match the curvature of AFIP-7 plates. Lateral (in-plane) reconstruction resolution will be best when the projection angles include views at or near the desired reconstruction view angles. The ends of the fuel plates are angled at ±17.7° relative to the center of the plate. Increasing the number of projections is desirable, but given the constraint of minimizing the number of projections, the projection acquisition angle should also span at least ±17.7° to optimize the lateral resolution of the angled reconstruction planes used to visualize the gaps at the ends of the fuel plates. If possible, enough projections should be used within the initial acquisition angle of 35.4° (±17.7°) to bring the projection angular sampling closer to 1°. Further testing will determine a more specific recommendation for the number and angular distribution of neutron radiographs that will produce the highest quality tomographic reconstruction of the AFIP-7 fuel element.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Pulsar disk systems

It is proposed that radio pulsars have the same basic physical features as X-ray pulsars. Specifically, it is suggested that active radio pulsars are rotating neutron stars surrounded by fossil disks left over from the collapse event and that energy is extracted from the rotation of the neutron star by interaction with the disk to produce pulsar luminosity. Attention is given to a model in which the neutron star acts as a unipolar generator (or Faraday disk dynamo) and the disk acts as a load. The self-excitation of the disk/pulsar system is considered along with aspects of disk persistence, pulsed emission, and magnetically field aligned currents to the disk. An investigation is conducted regarding the possibility of a deposition of material in the form of a disk about a pulsar, taking into account questions concerning disk survival. It is found that there are some promising features regarding a disk system.

Michel, F. C.↗

Activation analysis of the concrete in the Fleurus cyclotron facility - 25604

The purpose of this paper is to discuss the approach and the results of a recent activation analysis concerning a cyclotron facility located in Fleurus, Belgium, where isotopes of medical applications were produced by irradiating either solid (Tl) or gaseous targets (Xe) with 20-30 MeV proton beams. This paper discusses the choice of the intra-nuclear cascade model implemented in MCNP/X to correctly simulate the spallation reactions of the protons in the target, since no nuclear data are available for the isotopes of interest. TENDL nuclear data library, which is based on the models of the nuclear code system TALYS, plays a key role in the selection of the model. The neutron flux distribution throughout the installation and the activation rates in the concrete walls are then calculated with the help of a comprehensive MCNPX model of the facility. The estimated activities are in good agreement with the measurements taken in 2017 in the frame of the ongoing decommissioning of this facility. (authors)

43 PARTICLE ACCELERATORS↗

Conversion from film to image plates for transfer method neutron radiography of nuclear fuel

This paper summarizes efforts to characterize and qualify a computed radiography (CR) system for neutron radiography of irradiated nuclear fuel at Idaho National Laboratory (INL). INL has multiple programs that are actively developing, testing, and evaluating new nuclear fuels. Irradiated fuel experiments are subjected to a number of sequential post-irradiation examination techniques that provide insight into the overall behavior and performance of the fuel. One of the first and most important of these exams is neutron radiography, which provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Results from neutron radiography are often the driver for subsequent examinations of the PIE program. Features of interest that can be evaluated using neutron radiography include irradiation-induced swelling, isotopic and fuel-fragment redistribution, plate deformations, and fuel fracturing. The NRAD currently uses the foil-film transfer technique with film for imaging fuel. INL is pursuing multiple efforts to advance its neutron imaging capabilities for evaluating irradiated fuel and other applications, including conversion from film to CR image plates. Neutron CR is the current state-of-the-art for neutron imaging of highly-radioactive objects. Initial neutron radiographs of various types of nuclear fuel indicate that radiographs can be obtained of comparable image quality currently obtained using film. This paper provides neutron radiographs of representative irradiated fuel pins along with neutron radiographs of standards that informed the qualification of the neutron CR system for routine use. Additionally, this paper includes evaluations of some of the CR scanner parameters and their effects on image quality.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validating the Melusine Gamma Spectroscopy Tool

This technical report describes testing to evaluate the gamma spectroscopy tool, Melusine, under development by Pacific Northwest National Laboratory. The goal was to verify that the software can successfully be used to provide accurate results and statistical uncertainties for the detection of isotopes of interest and their activities. Of special interest were spectra similar to those produced by radionuclide stations that contribute to the Comprehensive Nuclear Test Ban Treaty Organization’s International Monitoring System. Two data sets were used to test Melusine’s capabilities. The first was the result of a multi-lab calibration effort based on neutron activations produced at the University of California at Davis. The second was taken from the Proficiency Test Exercises conducted by the CTBTO directly in 2005. In 37 of 42 cases, Melusine produced results in agreement with the best answer presently available, in most cases with calculated uncertainties comparable to or better than competing analyses. In fact, Melusine technically provided one more result than CTBTO’s PTE analyses that agreed with the “book answer” (Monte Carlo simulation). Despite these promising results, the Melusine software is still under development. Effort is especially needed to simplify its analysis process, improve stability, and provide user documentation. Some significant analysis tasks require further vetting, such as those to address summing effects. However, our test results indicate that Melusine’s calculations as presently implemented are sound and can be used to reliably analyze spectra from the CTBTO’s radionuclide stations.

CTBTO↗

HETEROGENEOUS ISOTOPIC ANOMALIES OF SM AND GD IN THE NORTON COUNTY METEORITE: EVIDENCE FOR IRRADIATION FROM THE ACTIVE EARLY SUN

Large and heterogeneous isotopic variations of {sup 150}Sm/{sup 149}Sm and {sup 158}Gd/{sup 157}Gd due to neutron capture reactions caused by cosmic-ray irradiation were found in chemical and mineral separates from the Norton County meteorite. The light-colored separates, consisting mainly of enstatite (Mg{sub 2}Si{sub 2}O{sub 6}), have a very large neutron fluence of 1.98 Multiplication-Sign 10{sup 17} n cm{sup -2}, which is 10 times higher than that of the whole rock. Furthermore, four chemical separates showed a large variation in neutron fluences, ranging from 1.82 Multiplication-Sign 10{sup 16} to 1.87 Multiplication-Sign 10{sup 17} n cm{sup -2}. The variable amounts of neutron fluences from a small single fragment of the Norton County meteorite cannot be simply explained by single-stage cosmic-ray irradiation in space. Rare earth element (REE) analyses revealed that the fractions with high neutron fluences have similar chemical properties to those in the early condensates in the solar system, showing depletions of Eu and Yb in their REE abundance patterns. The data provide evidence for an activity of the early Sun (T Tauri), suggesting the migration of early and intense irradiation materials into the Norton County meteorite's parent body.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiple-Input Data Acquisition System (MIDAS) for Measuring the Carbon Content in Soil Using Inelastic Neutron Scattering

This report describes work funder under STTR grants Phase I and II and carried out jointly by XIA LLC and Brookhaven National Laboratory (BNL). The project goal was to develop a mobile nuclear activation analysis instrument that could be towed behind a tractor to document soil carbon levels in agricultural lands for carbon credit certification. XIA developed large NaI(Tl) detectors with integrated digital pulse processors controlled over USB 2.0 and delivered 16 of these units to BNL for integration into the prototype instrument, together with the necessary software to calibrate them and collect data. For reasons that are unknown to XIA, the BNL participants never completed the prototype vehicle, performed system integration, or carried out the proposed qualification and field tests, leaving the project incomplete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The abundances of zirconium and hafnium in the solar system

The concentrations of zirconium and hafnium have been determined in the Orgueil, Murchison, Allende, Bruderheim, and Alais meteorites by radiochemical neutron activation analysis. The mean Zr/Hf weight ratio in the first four of these meteorites is 31.3 (plus or minus 2.2), indicating no major fractionation of Zr from Hf. Alais contains anomalously high amounts of many refractory lithophile elements, including Zr and Hf. Orgueil contains 3.1 ppm Zr and 0.11 ppm Hf, corresponding to 9.0 and 0.16 atoms, respectively, relative to 1 million Si atoms.

Ganapathy, R.↗

Towards the Development of Molten Salt Reactor Multiphysics Modeling Capabilities: Depletion, Thermochemistry, Reactor Dynamics, and Species Tracking

This report documents the simulation and modeling work performed under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, utilizing the tools and codes developed under the program. The focus in this Fiscal Year (FY) is on the depletion, thermochemistry, reactor dynamics, and species transport in MSRs. The fission products travelling in the entire primary loop is unique in MSRs. There are many physical/chemical mechanisms that can significantly affect the fission products concentration in the fuel salt, e.g., diffusion into gas bubbles, diffusion in the core moderators, deposition on the surface of structures/pipes, etc. The fission product concentration in the fuel salt can potentially affect the neutronics, system dynamics, chemical potentials, etc., so accurately predicting the fission products distribution in the primary loop is important. Under the main objective, different activities are pursued to assess the NEAMS tools applicability for a variety of areas on species transport, including the depletion analyses using Griffin (fission product source), the redox potential assessment at different depletion points, the assessment of xenon transport effect on the neutronics and reactor dynamics, a survey of correlations for calculating the mass transfer coefficient of different fission products, etc.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Crystal Structure Evolution of U-Si Nuclear Fuel Phases as a Function of Temperature

The crystal structure of the U 3 Si 2 line compound in the U-Si system was investigated as a function of temperature from room temperature t o1373 K using high temperature neutron time-of-flight diffraction on the HIPPO diffractometer at LANSCE. The U-Si system is actively researched due to its promise as an accident tolerant nuclear fuel. The simultaneous Rietveld refinement of five histograms from the five HIPPO detector rings provided fundamental datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of minority phases as a result of the synthesis route and especially due to hyper-stoichiometry, a stoichiometric U 3 Si 2.00 sample and a hyper-stoichiometric U 3 Si 2.01 sample were studied. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were observed. However, significant differences in the thermal expansion behavior were identified between the two compositions that warrant future investigations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗