Search NASA⌕ Search

SEARCH · Search NASA

Results for “Noble gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Unraveling the Early-Stage Ordering of Krypton Solid Bubbles in Molybdenum: A Multimodal Study

Self-organization of defects such as fission gas bubbles in materials can lead to high inventory capacity for fission gas storage and help mitigate swelling caused by fission gases in nuclear fuel materials under radiation in nuclear reactors. Here, we report the physical mechanism of self-organization of krypton (Kr) gas bubbles in molybdenum (Mo) under ion implantation. The ion fluence and temperature-dependent formation of Kr solid bubble superlattice (SBS) in Mo were investigated by using both synchrotron-based small-angle X-ray scattering (SAXS) and transmission electron microscopy (TEM). Early stage self-organization of gas bubbles is observed at a fluence of 2.5 × 10 16 ions/cm 2 at temperatures of 300–400 °C. The bubble lattice constant increases with increasing implantation temperature from 300 to 400 °C. Both experiments and atomic kinetic Monte Carlo modeling indicate that the Kr solid bubbles are weakly ordered in comparison to previously studied helium (He) gas bubble superlattice (GBS) while the lattice constant are relatively smaller for Kr SBS compared to that of He GBS. The irradiation conditions suggest that spinodal decomposition, which is a form of phase separation, probably precedes gas bubble ordering in Mo. Altogether, our work sheds light on the formation mechanism of noble gas superlattice toward the development of radiation-tolerant materials which are important for the design of advanced nuclear reactors.

36 MATERIALS SCIENCE↗

Quantum Effects in Cosmochemistry: Complexation Energy and Van Der Waals Radii

The subject of quantum effects in cosmochemistry was recently addressed with the goal of understanding how they contribute to Q-phase noble gas abundances found in meteorites. It was the pursuit of the Q-phase carrier of noble gases and their anomalous abundances that ultimately led to the identification, isolation, and discovery of presolar grains. In spite of its importance, Q-phase investigations have led a number of authors to reach conclusions that do not seem to be supported by quantum chemistry. In view of the subject's fundamental significance, additional study is called for. Two quantum properties of Q-phase candidates known as endohedral carbon-cage clathrates such as fullerenes will be addressed here. These are complexation energy and instability induced by Pauli blocking (exclusion principle).

Mittlefehldt, D. W.↗

Possible cometary origin of heavy noble gases in the atmospheres of Venus, earth, and Mars

Due consideration of the probable history of the Martian atmosphere, as well as noble-gas data from the Mars-derived SNC meteorites and from laboratory tests on the trapping of noble gases in ice, are the bases of the presently hypothesized domination of noble gases in the atmospheres of all terrestrial planets by a mixture of internal components and a contribution from comets. If verified, this hypothesis would underscore the significance of impacts for these planets' volatile inventories. The sizes of the hypothesized comets are of the order of 120 km for Venus and only 80 km for that which struck the earth.

Owen, Tobias↗

Properties of an imaging gas scintillation proportional counter

An instrument which combines the improved energy resolution offered by the gas scintillation proportional counter (GSPC) with the submillimeter imaging capabilities of the multiwire proportional counter (MWPC) is described. The imaging gas scintillation proportional counter detects the centroid of the UV light excited by X-ray photons interacting in the noble gas of the GSPC with a UV sensitive gas in the MWPC. The prototype counter yields a measured performance of 9% (FWHM) energy resolution and 0.9 mm (FWHM) spatial resolution at 6 keV. Further design refinements should achieve 18% (FWHM) energy resolution and 0.6 mm (FWHM) spatial resolution at 1 keV.

Ku, W. H.-M.↗

Measurements of Argon-39 from locations near historic underground nuclear explosions

Measurement of radioactive gas seepage from an underground nuclear explosion is one of the primary methods to confirm whether an event was nuclear in nature. Radioactive noble gas indicators that are commonly targeted by such measurements (e.g. 133Xe, 37Ar) have half-lives of 35 days or less. Argon-39, an activation product similar to 37Ar, is produced by the interaction between neutrons and potassium in the surrounding geology and has a half-life of 269 years. Measurements taken at three sites near three historic underground nuclear test locations at the Nevada National Security Site have all shown highly elevated levels of 39Ar in subsurface air decades after the test events. Elevated levels of 39Ar (30-50 times background) were also detected in atmospheric air collected roughly 30 cm above ground level near two of these sites, and outside the entrance of the one tunnel site. These measurements demonstrate that 39Ar has the potential to be a long-term signature of an underground nuclear event which can be reliably detected at the surface or in the shallow subsurface. This radionuclide detection of an underground nuclear event decades after the event takes place is in contrast to the commonly held assumption that detecting underground nuclear events via radionuclides at the surface needs to be done in a matter of months. Depending upon what further studies show about the robustness of this signature in a variety of geological settings, it may in fact be easy to detect underground nuclear events at the surface for a very long time post-detonation.

Johnson, Christine M.↗

Tortuosity measurement and the effects of finite pulse widths on xenon gas diffusion NMR studies of porous media

We have extended the utility of NMR as a technique to probe porous media structure over length scales of approximately 100-2000 microm by using the spin 1/2 noble gas 129Xe imbibed into the system's pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous media. We utilized Pulsed Gradient Spin Echo NMR measurements of the time-dependent diffusion coefficient, D(t), of the xenon gas filling the pore space to study further the measurements of both the pore surface-area-to-volume ratio, S/V(p), and the tortuosity (pore connectivity) of the medium. In uniform-size glass bead packs, we observed D(t) decreasing with increasing t, reaching an observed asymptote of approximately 0.62-0.65D(0), that could be measured over diffusion distances extending over multiple bead diameters. Measurements of D(t)/D(0) at differing gas pressures showed this tortuosity limit was not affected by changing the characteristic diffusion length of the spins during the diffusion encoding gradient pulse. This was not the case at the short time limit, where D(t)/D(0) was noticeably affected by the gas pressure in the sample. Increasing the gas pressure, and hence reducing D(0) and the diffusion during the gradient pulse served to reduce the previously observed deviation of D(t)/D(0) from the S/V(p) relation. The Pade approximation is used to interpolate between the long and short time limits in D(t). While the short time D(t) points lay above the interpolation line in the case of small beads, due to diffusion during the gradient pulse on the order of the pore size, it was also noted that the experimental D(t) data fell below the Pade line in the case of large beads, most likely due to finite size effects.

Non-NASA Center↗

Pulsed-field-gradient measurements of time-dependent gas diffusion

Pulsed-field-gradient NMR techniques are demonstrated for measurements of time-dependent gas diffusion. The standard PGSE technique and variants, applied to a free gas mixture of thermally polarized xenon and O2, are found to provide a reproducible measure of the xenon diffusion coefficient (5.71 x 10(-6) m2 s-1 for 1 atm of pure xenon), in excellent agreement with previous, non-NMR measurements. The utility of pulsed-field-gradient NMR techniques is demonstrated by the first measurement of time-dependent (i.e., restricted) gas diffusion inside a porous medium (a random pack of glass beads), with results that agree well with theory. Two modified NMR pulse sequences derived from the PGSE technique (named the Pulsed Gradient Echo, or PGE, and the Pulsed Gradient Multiple Spin Echo, or PGMSE) are also applied to measurements of time dependent diffusion of laser polarized xenon gas, with results in good agreement with previous measurements on thermally polarized gas. The PGMSE technique is found to be superior to the PGE method, and to standard PGSE techniques and variants, for efficiently measuring laser polarized noble gas diffusion over a wide range of diffusion times. Copyright 1998 Academic Press.

NASA Discipline Environmental Health↗

Gas transport across the low-permeability containment zone of an underground nuclear explosion

Understanding the nature of gas transport from an underground nuclear explosion (UNE) is required for evaluating the ability to detect and interpret either on-site or atmospheric signatures of noble gas radionuclides resulting from the event. We performed a pressure and chemical tracer monitoring experiment at the site of an underground nuclear test that occurred in a tunnel in Nevada to evaluate the possible modes of gas transport to the surface. The site represents a very well-contained, low gaspermeability end member for past UNEs at the Nevada National Security Site. However, there is very strong evidence that gases detected at the surface during a period of low atmospheric pressure resulted from fractures of extremely small aperture that are essentially invisible. Our analyses also suggest that gases would have easily migrated to the top of the high-permeability collapse zone following the detonation minimizing the final distance required for migration along these narrow fractures to the surface. This indicates that on-site detection of gases emanating from such low-permeability sites is feasible while standoff detection of atmospheric plumes may also be possible at local distances for sufficiently high fracture densities. Finally, our results show that gas leakage into the atmosphere also occurred directly from the tunnel portal and should be monitored in future tunnel gas sampling experiments for the purpose of better understanding relative contributions to detection of radioxenon releases via both fracture network and tunnel transport.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Could icy impacts reconcile Venus with Earth and Mars

The problem of volatile sources in the martian atomosphere was studied. It is suggested that a combination of an impact by an icy planetesimal (radius about 150 km) and solar wind implantation of neon could explain the noble gas abundances on Venus. Early solar wind would supply the right amount of neon with the correct Ne-20/Ne-22 as compared with lunar soils. However, observations of noble gases in a fresh comet are needed to test this hypothesis.

Owen, T.↗

He, Ne and Ar in chondritic Ni-Fe as irradiation hardness sensors.

Noble gas analyses of the Ni-Fe of 9 L, 5 H, and 2 LL chondrites quantitatively support previous suggestions of radiogenic He-4 recoil and He-3 deficits. Furthermore, noble gases in the Ni-Fe show evidence for in situ produced radiogenic He-4 and in some cases for recoil loss of Ar-38 and gain of Ne-21. The ratio of spallogenic Ar-38 and Ne-21 in the metal phase is found to correlate strongly with He-3/Ne-21 and Ne-22/Ne-21 in bulk samples of these chondrites. This is proof of the dependence of these ratios on the irradiation hardness experienced by the meteoroid in space. 'Hardness indices' n equals 1.9-2.2 are found, indicating that on the average the stone meteoroids from which the samples came were smaller in mass than iron meteoroids. The spallogenic Ne-21/Ar-38 ratio in metallic Ni-Fe can be used with the semi-empirical production model deduced from the Grant iron meteorite to calibrate spallogenic He-3/Ne-21 and Ne-21/Ar-38 in bulk samples of L, LL and H chondrites for meteoroid size and sample location allowing the estimation of minimal meteoroid masses.

Nyquist, L.↗

Incorporation of Solar Noble Gases from a Nebula-Derived Atmosphere During Magma Ocean Cooling

The presence of solar noble gases in the deep interior of the Earth is inferred from the Ne isotopic compositions of MORB (Mid-ocean Ridge Basalts) and OIB (Oceanic Island Basalt); Ar data may also consistent with a solar component in the deep mantle. Models of the transport and distribution of noble gases in the earth's mantle allow for the presence of solar Ar/Ne and Xe/Ne ratios and permit the calculation of lower mantle noble gas concentrations. These mantle data and models also indicate that the Earth suffered early (0.7 to 2 x 10(exp 8) yr) and large (greater than 99 percent) losses of noble gases from the interior, a result previously concluded for atmospheric Xe. We have pursued the suggestion that solar noble gases were incorporated in the forming Earth from a massive, nebula-derived atmosphere which promoted large-scale melting, so that gases from this atmosphere dissolved in the magma ocean and were mixed downward. Models of a primitive atmosphere captured from the solar nebula and supported by accretion luminosity indicate that pressures at the Earth's surface were adequate (and largely more than the required 100 Atm) to dissolve sufficient gases. We have calculated the coupled evolution of the magma ocean and the overlying atmosphere under conditions corresponding to the cessation (or severe attenuation) of the sustaining accretion luminosity, prior to the complete removal of the solar nebula. Such a condition was likely to obtain, for instance, when most of the unaccumulated mass resided in large bodies which were only sporadically accreted. The luminosity supporting the atmosphere is then that provided by the cooling Earth, consideration of which sets a lower limit to the time required to solidify the mantle and terminate the incorporation of atmospheric gases within it. In our initial calculations, we have fixed the nebula temperature at To = 300K, a value likely to be appropriate for nebular temperatures at lAU in the early planet-building epoch. We treated the background (nebula) pressure as an adjustable, time-dependent parameter. Additional information is contained within the original extended abstract.

Woolum, D. S.↗

The Potassium-Argon Laser Experiment (KArLE): In Situ Geochronology for Planetary Robotic Missions

The Potassium (K) - Argon (Ar) Laser Experiment (KArLE) will make in situ noble-gas geochronology measurements aboard planetary robotic landers and roverss. Laser-Induced Breakdown Spectroscopy (LIBS) is used to measure the K abun-dance in a sample and to release its noble gases; the evolved Ar is measured by mass spectrometry (MS); and rela-tive K content is related to absolute Ar abundance by sample mass, determined by optical measurement of the ablated volume. KArLE measures a whole-rock K-Ar age to 10% or better for rocks 2 Ga or older, sufficient to resolve the absolute age of many planetary samples. The LIBS-MS approach is attractive because the analytical components have been flight proven, do not require further technical development, and provide complementary measurements as well as in situ geochronology.

KArLE↗

Sorption of noble gases by solids, with reference to meteorites. II - Chromite and carbon. III - Sulfides, spinels, and other substances; on the origin of planetary gases

The trapping of noble gases by chromite and carbon, two putative carriers of primordial noble gases in meteorites, was studied by synthesizing 19 samples in a Ne-Ar-Kr-Xe atmosphere at 440-720 K. Noble gas contents are found to approximately obey Henry's Law, but only slight correlations are found with composition, surface area, or adsorption temperature. Geometric mean distribution coefficients for bulk samples and HCl residues in 10 cu cm STP/g atm are: Xe 100, Kr 15, Ar 3.5, and Ne 0.62. Elemental fractionation data support the suggestion of Lewis et al. (1977) that chromite and carbon in C2 and C3 chondrites were formed by the reaction: Fe, Cr + 4CO yields (Fe, Cr)3O4 + 4C + carbides. In contrast to meteoritic minerals, the synthetic specimens show no isotopic fractionation of noble gases. In a subsequent study, attention is given to the cases of sulfides and spinels, on the way to consideration of the origin of planetary gases. Sulfides showed three distinctive trends relative to chromite or magnetite. The elemental fractionation pattern of Ar, Kr and Xe in meteorites, terrestrial rocks and planets resembles the adsorption patterns on the carbons, spinels, sulfides, and other solids studied. The high release temperature of meteoritic noble gases may be explained by transformation of the physisorbed or chemisorbed gas. The ready loss of meteoritic heavy gases on surficial oxidation is consistent with adsorption, as is the high abundance.

Yang, J.↗

Study of solid molecular deuterium D 2 growth under gas pressure

The injection of high-speed cryogenic pellets made of frozen hydrogen-isotopes, represents to date the most effective method to fuel magnetically confined thermonuclear fusion plasmas. Additionally, the injection of very large pellets composed of cryogenic solid of some suitable impurity (typically a noble-gas such as H 2 , Ne, or H 2 /Ne, D 2 /Ne mixtures), shattered in relatively small fragments just before entering the plasma, seems to be the most promising method to reduce the damage risks for the plasma-facing components in case of a plasma disruption. This technology, known as "Shattered Pellet Injection" (SPI), allows to spread out the plasma energy and mitigate possible damage to the in-vessel components, as well as to densify the plasma to suppress the formation of runaway electrons, and/or dissipate their energy. Several techniques to produce and launch cryogenic pellets have been investigated in the past decades. "Pipe gun" injectors are reliable and relatively simple devices are still commonly used today. They make use of single- or two-stage pneumatic light-gas guns to accelerate the pellet at high speeds. In these injectors, the cryogenic pellets are formed “ in situ ” (i.e., inside the launching barrel), by de-sublimating them directly from the gas phase, i.e., at temperatures and pressures below those of the triple point. The simplest case is pure deuterium pellets ($\mathcal{T}$ < 18.7 K, $\mathcal{P}$ < 171.3 hPa). The production of good quality solid deuterium, capable of withstanding the mechanical stress during the acceleration of the pellets, is a key issue. To this end the phase transition of deuterium from gas to solid (and vice versa) is modeled with extensive molecular-dynamics (MD) simulations. Furthermore, the solid growth from the gas phase is simulated in an ample range of temperatures and pressures, to find the best compromise between growth velocity and mechanical properties of the resulting solid system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn s magnetosphere, and a steady flux of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager1 . The ubiquitous, surface- hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 Km altitude (approximately 1hPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 141Dalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn's magnetosphere, and a steady flow of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager 1. The ubiquitous, surface-hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 km altitude (approximately lhPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 14lDalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

Stagnation-point heat transfer correlation for ionized gases

Based on previous laminar boundary-layer solutions for argon, xenon, nitrogen, and air, it is shown that the effect of gas ionization on stagnation-point heat transfer can be correlated with the variation of the frozen Prandtl number across the boundary layer. A formula is obtained for stagnation-point heat transfer in a noble gas and is shown to be valid from the low-temperature range to the region of strong ionization. It is concluded that the considered effect can be well correlated by the 0.7 power of the Prandtl-number ratio across the boundary layer.

Bade, W. L.↗

The regolith history of 14307

Noble gas and trace element analyses of matrix and a clast from breccia 14307 are reported. This sample was exposed to a large neutron fluence, as seen by an elevated Sm-150/Sm-149 ratio and by noble gases, particularly Xe-136 from neutron fission of U-235. Strong constraints on the exposure history result from combined consideration of Sm-150, Xe-136, and spallation noble gases. Both clast and matrix were irradiated for about 1 AE under substantial shielding beginning at least 2 AE ago, probably more than 3 AE ago. The manifestations of soil exposure seen in the matrix - solar wind gases, glass formation, etc. - thus must have been acquired in an ancient epoch. The matrix has had a longer exposure to cosmic rays than the clast, presumably during its prebrecciation history as a soil. Brecciation probably occurred more than 1 AE ago, perhaps more than 3 AE ago, but at least 0.4 AE after the formation of the matrix constituents.

Bernatowicz, T.↗