Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nonlinear optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

An Improved Sub-component Fatigue Testing Method for Material Characterization

In this paper an improved sub-component fatigue testing method is proposed, in which structural optimization is used to obtain specimens in which fatigue failure is precipitated in the designated area away from the boundaries, i.e., load application and fixture points. This is achieved by optimizing the nonlinear beam taper and the dynamic excitation. The major requirement for accurate material characterization through sub-component tests concerns unbiased stress states in the gauge section. However, empiricism shows that many sub-component high-cycle fatigue testing methods suffer from failure in the boundaries rather than the gauge section, which causes bias. The common practice for reinforcing those regions only shifts the issue into new areas of local discontinuities where failure is still caused remotely from the gauge section. An experimental proof of concept demonstrates that optimization of the beam taper can be used to obtain unbiased fatigue test data.

42 ENGINEERING↗

Controlled Nonlinear Stochastic Delay Equations: Part II: Approximations and Pipe-Flow Representations

This is the second part of a work dealing with key issues that have not been addressed in the modeling and numerical optimization of nonlinear stochastic delay systems. We consider new classes of models, such as those with nonlinear functions of several controls (such as products), each with is own delay, controlled random Poisson measure driving terms, admissions control with delayed retrials, and others. Part I was concerned with issues concerning the class of admissible controls and their approximations, since the classical definitions are inadequate for our models. This part is concerned with transportation equation representations and their approximations. Such representations of nonlinear stochastic delay models have been crucial in the development of numerical algorithms with much reduced memory and computational requirements. The representations for the new models are not obvious and are developed. They also provide a template for the adaptation of the Markov chain approximation numerical methods.

97 MATHEMATICS AND COMPUTING↗

Controlled Nonlinear Stochastic Delay Equations: Part I: Modeling and Approximations

This two-part paper deals with 'foundational' issues that have not been previously considered in the modeling and numerical optimization of nonlinear stochastic delay systems. There are new classes of models, such as those with nonlinear functions of several controls (such as products), each with is own delay, controlled random Poisson measure driving terms, admissions control with delayed retrials, and others. There are two basic and interconnected themes for these models. The first, dealt with in this part, concerns the definition of admissible control. The classical definition of an admissible control as a nonanticipative relaxed control is inadequate for these models and needs to be extended. This is needed for the convergence proofs of numerical approximations for optimal controls as well as to have a well-defined model. It is shown that the new classes of admissible controls do not enlarge the range of the value functions, is closed (together with the associated paths) under weak convergence, and is approximatable by ordinary controls. The second theme, dealt with in Part II, concerns transportation equation representations, and their role in the development of numerical algorithms with much reduced memory and computational requirements.

97 MATHEMATICS AND COMPUTING↗

Exploiting Power Flow Manifold to Solve AC Optimal Power Flow

AC optimal power flow has proven difficult to solve with interior point methods on GPUs. This is largely due to challenging linear algebra problems that current state of the art massively parallel linear solvers struggle with. However, the advent of Riemannian optimization techniques and the fact that the power flow equations form a smooth manifold present an alternative approach. In this talk, we present the basics of Riemannian optimization techniques in which optimization is done directly on a manifold. Then we present computational results showing that Riemannian techniques are capable of producing solutions of comparable quality as interior point methods.

AC optimal power flow↗

Online Optimization of NSLS-II Dynamic Aperture and Injection Transient (Facility Improvement Project)

The Facility Improvement Project (FIP) “Methods of online optimization of NSLS-II storage ring concurrent with user operations” proposed and approved in 2018 is now complete. The first goal is the online optimization of nonlinear beam dynamics to increase the beam lifetime and injection efficiency. We have developed a model-independent optimization technique using advanced algorithms. Using this technique, we increased the NSLS-II dynamic aperture by 20% and reduced the amplitude-dependent tune shift by a factor of two. We applied sextupole optimization to the new high-chromaticity lattice, which has been developed to improve the beam stability and to increase the single-bunch beam intensity. We were able to double the injection efficiency and exceed 90%. The second goal of this project is to provide the top-off injection with minimized perturbations of the beamline user operations. To achieve the transparent injection, we optimize the matching of four storage ring injection kickers reducing the perturbation of the stored beam orbit. The first application of the online optimization resulted in a reduction of the amplitude of residual beam oscillation by a factor of six, from 1300 μm down to 200 μm. Further improvement was limited by the timing jitter of the trigger boards. Then, we replaced all trigger boards with a new design and reduced the timing jitter by a factor of five, from 5 ns down to 1 ns. This upgrade resulted in the injection transient reduction from 200 μm to 120 μm. To optimize the full set of kicker parameters, including the trigger timing, amplitude, and pulse width, we upgraded all kicker power supplies with the capability of tunable waveform width. As a result, we have reduced the injection transient to the limit of 60 μm.

43 PARTICLE ACCELERATORS↗

Advanced control techniques for modern inertia based inverters

In this research three artificial intelligent (AI)-based techniques are proposed to regulate the voltage and frequency of a grid-connected inverter. The increase in the penetration of renewable energy sources (RESs) into the power grid has led to the increase in the penetration of fast-responding inertia-less power converters. The increase in the penetration of these power electronics converters changes the nature of the conventional grid, in which the existing kinetic inertia in the rotating parts of the enormous generators plays a vital role. The concept of virtual inertia control scheme is proposed to make the behavior of grid connected inverters more similar to the synchronous generators, by mimicking the mechanical behavior of a synchronous generator. Conventional control techniques lack to perform optimally in nonlinear, uncertain, inaccurate power grids. Besides, the decoupled control assumption in conventional VSGs makes them nonoptimal in resistive grids. The neural network predictive controller, the heuristic dynamic programming, and the dual heuristic dynamic programming techniques are presented in this research to overcome the draw backs of conventional VSGs. The nonlinear characteristics of neural networks, and the online training enable the proposed methods to perform as robust and optimal controllers. The simulation and the experimental laboratory prototype results are provided to demonstrate the effectiveness of the proposed techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear multiobjective and dynamic real-time predictive optimization for optimal operation of baseload power plants under variable renewable energy

Considering the increase of disruptive variable renewable energy penetration into the power grid, this article focuses on the investigation of a multiobjective and dynamic real-time optimization framework to address the cycling of large-scale power plants under renewable penetration. In this framework, a parallelized particle swarm optimization step is first performed to generate feasible initial points. Then, a multiobjective and dynamic real-time optimization formulation generates optimal trajectories. Further, the benefit of predictive capability is investigated for the dynamic component, which introduces the novel nonlinear multiobjective and dynamic real-time predictive optimization approach. Two multiobjective formulations to obtain Pareto front optimal in real time are explored: the modified Tchebycheff-based weighted metric and ϵ-constraint methods. Economic and environmental objectives are considered in this study. A novel topical discussion on the intersection of dynamic real-time optimization with model predictive control is also presented. The developed framework is successfully applied to a baseload coal-fired power plant with postcombustion CO 2 capture. Results indicate that the approach can be deployed for a large-scale system if automatic differentiation, model reduction, and parallelization are adopted to improve computational tractability, with computational improvement up to 120-folds after performing these steps. Finally, market and carbon policies showed an impact on the optimal compromise between the objectives with an additional 63 ton of CO 2 captured under favorable market conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Feasibility of Market Manipulation and Energy Storage Arbitrage via Load-Altering Attacks

Around the globe, electric power networks are transforming into complex cyber–physical energy systems (CPES) due to the accelerating integration of both information and communication technologies (ICT) and distributed energy resources. While this integration improves power grid operations, the growing number of Internet-of-Things (IoT) controllers and high-wattage appliances being connected to the electric grid is creating new attack vectors, largely inherited from the IoT ecosystem, that could lead to disruptions and potentially energy market manipulation via coordinated load-altering attacks (LAAs). In this article, we explore the feasibility and effects of a realistic LAA targeted at IoT high-wattage loads connected at the distribution system level, designed to manipulate local energy markets and perform energy storage (ES) arbitrage. Realistic integrated transmission and distribution (T&D) systems are used to demonstrate the effects that LAAs have on locational marginal prices at the transmission level and in distribution systems adjacent to the targeted network.

25 ENERGY STORAGE↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

MO-C-18A-01: Advances in Model-Based 3D Image Reconstruction

Recent years have seen the emergence of CT image reconstruction techniques that exploit physical models of the imaging system, photon statistics, and even the patient to achieve improved 3D image quality and/or reduction of radiation dose. With numerous advantages in comparison to conventional 3D filtered backprojection, such techniques bring a variety of challenges as well, including: a demanding computational load associated with sophisticated forward models and iterative optimization methods; nonlinearity and nonstationarity in image quality characteristics; a complex dependency on multiple free parameters; and the need to understand how best to incorporate prior information (including patient-specific prior images) within the reconstruction process. The advantages, however, are even greater – for example: improved image quality; reduced dose; robustness to noise and artifacts; task-specific reconstruction protocols; suitability to novel CT imaging platforms and noncircular orbits; and incorporation of known characteristics of the imager and patient that are conventionally discarded. This symposium features experts in 3D image reconstruction, image quality assessment, and the translation of such methods to emerging clinical applications. Dr. Chen will address novel methods for the incorporation of prior information in 3D and 4D CT reconstruction techniques. Dr. Pan will show recent advances in optimization-based reconstruction that enable potential reduction of dose and sampling requirements. Dr. Stayman will describe a “task-based imaging” approach that leverages models of the imaging system and patient in combination with a specification of the imaging task to optimize both the acquisition and reconstruction process. Dr. Samei will describe the development of methods for image quality assessment in such nonlinear reconstruction techniques and the use of these methods to characterize and optimize image quality and dose in a spectrum of clinical applications. Learning Objectives: Learn the general methodologies associated with model-based 3D image reconstruction. Learn the potential advantages in image quality and dose associated with model-based image reconstruction. Learn the challenges associated with computational load and image quality assessment for such reconstruction methods. Learn how imaging task can be incorporated as a means to drive optimal image acquisition and reconstruction techniques. Learn how model-based reconstruction methods can incorporate prior information to improve image quality, ease sampling requirements, and reduce dose.

60 APPLIED LIFE SCIENCES↗

A learning-augmented approach for AC optimal power flow

Because of the high nonlinearity of AC optimal power flow (OPF), numerous efforts have been made in recent decades to find efficient methods. Machine learning (ML) has proven to significantly reduce the computational costs in many real-world problems. Thus, this paper develops a learning-augmented method for solving AC OPF, which integrates both power network equations and ML to yield near-optimal solutions. More specifically, ML models are developed to first predict bus voltage magnitudes and angles. Then, physics-based network equations are employed to calculate the power injection at different buses. Three ML algorithms, i.e., random forest, multi-target decision tree, and extreme learning machine, are explored and compared. To evaluate the efficiency of the proposed learning-augmented AC OPF solver, the MATPOWER Interior Point Solver is adopted as a baseline. Case studies on both 500-bus and 4918-bus test networks show that the proposed learning-augmented method has reduced the computational time by 15–100 times depending on the network size with a minimal loss in optimality.

42 ENGINEERING↗

Optimizing the design and operation of water networks: Two decomposition approaches

We consider the design and operation of water networks simultaneously. Water network problems can be divided into two categories: the design problem and the operation problem. The design problem involves determining the appropriate pipe sizing and placements of pump stations, while the operation problem involves scheduling pump stations over multiple time periods to account for changes in supply and demand. Our focus is on networks that involve water co-produced with oil and gas. While solving the optimization formulation for such networks, we found that obtaining a primal (feasible) solution is more challenging than obtaining dual bounds using off-the-shelf mixed-integer nonlinear programming solvers. Therefore, we propose two methods to obtain good primal solutions. One method involves a decomposition framework that utilizes a convex reformulation, while the other is based on time decomposition. To test our proposed methods, we conduct computational experiments on a network derived from the PARETO case study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Control for Battery Storage Using Nonlinear Models

Battery storage system (BSS) becomes increasingly popular for grid applications due to the advance in battery and power electronics technologies as well as the growing need of flexibility and reserve from power systems with rapidly developed renewable generation. Successful assessment and deployment of BSS requires optimizing its operation and therefore maximizing the potential benefits. Although there exist studies that develop optimal control for evaluation or operational scheduling of BSS, modeling of charging/discharging operation and the corresponding impacts on state-of-charge (SOC) is over simplified in these methods. This paper develops an optimal control for BSS evaluation and operational scheduling using a general nonlinear model that expresses the change of SOC as a function of charging/discharging power and SOC level. The proposed method is compared with a typical existing method through a real-world energy storage evaluation project to show the significance of the proposed method.

battery, energy storage system, dynamic programmin↗

Fast model-based scenario optimization in NSTX-U enabled by analytic gradient computation

Model-based optimization offers a systematic approach to advanced scenario planning. In this case, the feedforward-control inputs (actuator trajectories) that are needed to attain and sustain a desired scenario are obtained by solving a nonlinear constrained optimization problem. This class of problems generally minimize a cost function that measures the difference between desired and actual plasma states. Several numerical optimization algorithms, such as sequential quadratic programming, require repeated calculation of the cost function gradients with respect to the input trajectories. Calculating these gradients numerically can be computationally intensive, increasing the time needed to solve the feedforward-control optimization problem. Here, this work introduces a method to analytically calculate these cost function gradients from the current profile evolution model. This can significantly reduce the computational time and allow for fast feedforward-control optimization, which would eventually enable optimal scenario planning between discharges. The performance of the feedforward optimizer with analytical gradients is compared to a traditional optimization algorithm based on numerical gradients for different NSTX-U scenarios. The plasma dynamics in the optimization algorithm are simulated using the Control Oriented Transport SIMulator (COTSIM). Results of the work show that analytical gradients consistently reduce the computation time while achieving trajectories that are comparable to those obtained by traditional optimization algorithms based on numerical gradients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phonon-informed Neural Thermal Scattering (NeTS) Optimization for Crystalline Graphite and Beryllium Metal

Fast neutrons born from fission lose energy through scattering interactions in the process of slowing-down. As neutrons thermalize to the order of $k$ $b$ $T$ (where $k$ $b$ is the Boltzmann constant, and $T$ is the temperature of the medium), their de Broglie wavelength and energy approaches the order of inter-atomic spacing and quantized lattice vibrations, i.e., phonons. At thermal energies, the thermal scattering law (TSL), i.e., $S$($α, β$), captures crystal binding contributions to the total reaction rate, or cross section. This dimensionless material property describes the energy ($β$) and momentum ($α$) exchanges available in a medium. Currently, $S$($α, β$) is evaluated in the Full Law Analysis Scattering System Hub (FLASSH) code for discrete inputs and stored as ENDF/B File 7 for 0-phonon elastic (MT 2) and n-phonon inelastic (MT 4) processes. Further processing recasts $S$($α, β$) into cumulative distribution functions for sampling post-collision scattering kinematics. In practice, interpolation schemes are employed to access data between tabulated values. An improvement to this juncture of the nuclear data pipeline is supplying cross sections on-the-fly (OTF), as has been developed for the un-resolved resonance region to minimize non-physical interpolation errors. This capability may improve simulation accuracy for accident and transient analyses, where rapidly varying changes in temperature and pressure are difficult to predict beforehand. To do so, deep artificial neural networks (ANNs) can be employed which collapse non-linear, complex data into a lightweight dictionary of neural weights and biases. This has been successfully demonstrated for the hydrogen in light water $S$($α, β$) dataset in the form of a Neural Thermal Scattering (NeTS) module. In this work, the NeTS framework is extended to consider the impact of material-dependent dynamical features on optimal neural pre-processing and architecture design decisions, such as number of neurons per hidden layer, residual skip connections and neural depth. New NeTS modules for crystalline graphite and beryllium metal illuminate a novel correlation between dynamical nonlinearity and optimal neural parametrization when deploying $S$($α, β$) on-the-fly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimal Allocation of Dynamic Var Sources Using the Voronoi Diagram Method Integrating Linear Programing

Dynamic reactive power (var) sources can effectively mitigate fault-induced delayed voltage recovery (FIDVR) issues. This paper optimizes the sizes of dynamic var sources at given locations against FIDVR issues under severe contingencies. First, the geometric characteristics about the non-convex solution space of this problem are studied. Accordingly, a Voronoi diagram approach integrating linear programming (LP) is proposed, which disperses a number of sample points of potential solutions in the searching space to construct a Voronoi diagram blending the local cost functions over the entire space by Barycentric interpolation in Voronoi regions. New sample points are then recursively added, including the tentative optimal point using LP, the most depopulated area point ensuring global fidelity, and the connecting point, until the stopping criterion is met. The new approach is demonstrated in detail on the WSCC 9-bus system. A case study on the NPCC 140-bus system also validates that the proposed approach can effectively estimate the boundary and the geometry of the feasible solution region in the searching space and find the optimal solution.

barycentric interpolation↗

A Nonlinear Regression Method for Composite Protection Modeling of Induction Motor Loads

Protection equipment are used to prevent damages to induction motor loads by isolating those from the power network in the event of severe faults. Modeling the response of induction motor loads and their protection is vital for power system planning and operation, especially in understanding system's response moments after a fault has occurred. This article proposes an optimization based framework to generate composite protection models for commercial building motor loads. Introducing a mathematical abstraction, the task of finding a suitable (simplified) model of the composite protection scheme is formulated as a nonlinear regression problem. Numerical examples are provided to illustrate the application of the framework.

Kundu, Soumya↗

Optimization of District Heating Network Parameters in Steady-State Operation

Here we examine the modeling, simulation, and optimization of district heating systems, which are widely used for thermal transport using steam or hot water as a carrier. We propose a generalizable framework to specify network models and scenario parameters, and develop an optimization method for evaluating system states including pressures, fluid flowrates, and temperatures throughout the network. The network modeling includes pipes, thermal plants, pumps, and passive or controllable loads as system components. We propose basic models for thermodynamic fluid transport and enforce the balance of physical quantities in steady-state flow over co-located outgoing and return networks. We formulate an optimization problem with steam and hot water as the outgoing and return carriers, as in legacy twentieth century systems. The physical laws and engineering limitations are specified for each component type, and the thermal network flow optimization problem is formulated and solved for a realistic test network under several scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗