Development of a drift-correction procedure for a direct-reading spectrometer

A procedure which provides automatic correction for drifts in the radiometric sensitivity of each detector channel in a direct-reading emission spectrometer is described. Such drifts are customarily controlled by the regular analyses of standards, which provide corrections for changes in the excitational, optical, and electronic components of the instrument. This standardization procedure, however, corrects for the optical and electronic drifts. It is a step that must be taken if the time, effort, and cost of processing standards is to be minimized. This method of radiometric drift correction uses a 1,000-W tungsten-halogen reference lamp to illuminate each detector through the same optical path as that traversed during sample analysis. The responses of the detector channels to this reference light are regularly compared with channel response to the same light intensity at the time of analytical calibration in order to determine and correct for drift. Except for placing the lamp in position, the procedure is fully automated and compensates for changes in spectral intensity due to variations in lamp current. A discussion of the implementation of this drift-correction system is included.

Chapman, G. B., II↗

Low-background trace-gas detector

Spectrophone detects very small concentrations of trace gases. With gas in sample cell, laser is tuned to absorption line of interest. Molecular absorption in cell produces pulsed acoustical pressure at chopper frequency. Two optical paths with very different absorption lengths are used to pretune cell to balance out background absorption by cell windows.

Rosengren, L.↗

Development of a drift-correction procedure for a photoelectric spectrometer

A technique has been developed to automatically correct for drifts in the radiometric sensitivity of the detector channels in a direct-reading emission spectrometer. The method utilizes a 1000 W tungsten-halogen reference lamp to illuminate the detectors through the same optical path as that traversed during the analysis of the sample. Detector channel responses to the light are compared to those for the same light intensity at the time of analytical calibration. This corrects for the drift. It is noted that with the exception of positioning the lamp, the procedure is fully automatic.

Chapman, G. B., II↗

Measurements of constituents of interest in the photochemistry of the ozone layer using infrared techniques

Infrared solar spectra and infrared atmospheric emission spectra were obtained from the ground, from aircraft and from balloons. The initial detection of most stratospheric molecules was achieved by the solar spectral technique because better resolution helps remove interference from other molecules. Because the sun is an intense source of radiation, the resolution which can be obtained with good signal-to-noise, is greater than with atmospheric emission spectroscopy. Data are generally taken using a method that enhances the number of molecules in the optical path i.e. at large solar zenith angles for solar spectra and at low elevation angles for atmospheric emission spectra. The search for molecules which are predicted to be present but which, the detection of a molecule known to be present from other measurement techniques but observed for the first time in infrared solar spectra, and some further data on the variability of HNO3 are discussed.

Murcray, D. G.↗

Infra-red measurements of stratospheric composition. I - The balloon instrument and water vapour measurements

The design and construction of a balloon-borne instrument for remote-sensing of stratospheric composition is described. Thermal emission from the constituents is detected and the spectral selectivity of the instrument is tailored to a specific gas by the use of a cell of the same gas in the optical path of the radiometer. The pressure of the gas in the cell is cycled and the resultant transmission function is shown to be highly selective to radiation from the same gas in the atmosphere. The first flight of the instrument and the retrieval of a water vapour profile in the range 15-40 km is described.

Chaloner, C. P.↗

High-resolution spectrometrometry/interferometer

Modified double-pass interferometer has several features that maximize its resolution. Proposed for rocket-borne probes of upper atmosphere, it includes cat's-eye retroreflectors in both arms, wedge-shaped beam splitter, and wedged optical-path compensator. Advantages are full tilt compensation, minimal spectrum "channeling," easy tunability, maximum fringe contrast, and even two-sided interferograms.

Breckinridge, J. B.↗

Laser Doppler velocity simulator

A method and apparatus for inducing a Doppler frequency shift in a reference beam laser velocimeter light beam to simulate target velocity are described. The light beam is passed through a rotating refractive transparent block positioned between two reference points along the beam which results in a continuous change in the light beam optical path length between the reference points according to a known function. The velocity indicated by the laser velocimeter is compared to the known simulated velocity function for velocimeter testing and calibration.

Franke, J. M.↗

Velocity servo for continuous scan Fourier interference spectrometer

A velocity servo for continuous scan Fourier interference spectrometer of the double pass retroreflector type having two cat's eye retroreflectors is described. The servo uses an open loop, lead screw drive system for one retroreflector with compensation for any variations in speed of drive of the lead screw provided by sensing any variation in the rate of reference laser fringes, and producing an error signal from such variation used to compensate by energizing a moving coil actuator for the other retroreflector optical path, and energizing (through a highpass filter) piezoelectric actuators for the secondary mirrors of the retroreflectors.

Schindler, R. A.↗

Multispectral scanner optical system

An optical system for use in a multispectral scanner of the type used in video imaging devices is disclosed. Electromagnetic radiation reflected by a rotating scan mirror is focused by a concave primary telescope mirror and collimated by a second concave mirror. The collimated beam is split by a dichroic filter which transmits radiant energy in the infrared spectrum and reflects visible and near infrared energy. The long wavelength beam is filtered and focused on an infrared detector positioned in a cryogenic environment. The short wavelength beam is dispersed by a pair of prisms, then projected on an array of detectors also mounted in a cryogenic environment and oriented at an angle relative to the optical path of the dispersed short wavelength beam.

Stokes, R. C.↗

Internal image motion compensation system for the Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope Facility (SIRTF) is being designed as a 1-m, cryogenically cooled telescope capable of a thirty-fold improvement over currently available infrared instruments. The SIRTF, mounted in the Orbiter bay on the Instrument Pointing System (IPS), requires that the image at the focal plane be stabilized to better than 0.1 arcsec with an absolute accuracy of 1 arcsec in order to attain this goal. Current estimates of IPS performance for both stability and accuracy indicate that additional stabilization will be necessary to meet the SIRTF requirements. An Image Motion Compensation (IMC) system, utilizing a Charge Coupled Device (CCD) star tracker located at the focal plane and a steerable mirror in the SIRTF optical path, has been designed to work in conjunction with the IPS.

Lorell, K. R.↗

Tunable birefringent networks

Consideration is given to mechanically tuned birefringent filters for the spectral range 4500-7500 A with bandpasses as narrow as 50 mA and stability of better than 5 mA. Two tuning techniques are described: optical path change and waveplate tuning. The tuning techniques are mechanically simple and require minimal demands on encoders and drive electronics. Tuning to a random wavelength can be accomplished in less than one second while adjacent wavelengths can be reached in a fraction of a second.

Title, A. M.↗

Modification to Scott's method for direct integration of gaseous transmission to improve speed and accuracy

Two limitations to the method of Scott for rapid direct integration of gaseous transmission in a finite spectral interval over an inhomogeneous optical path are discussed. One of these is the inability to use a precomputed form of the Voigt line shape, which can be parameterized via the linewidth alone. This is rectified using the Voigt shape approximation of Kielkopf, which involves a linear combination of three functions which can be pre-computed: the Lorentz shape, the Doppler shape and a correction function. The other limitation involves situations where lines must be treated individually, either line positions must be known with great precision or a uniform value for the widths of all lines in the spectral interval does not describe the transmission adequately. In this case, the strongest lines are treated individually, while the remainder are treated assuming uniform line widths and line positions coincident with positions on the frequency grid, i.e. following Scott's method directly.

Orton, G. S.↗

The optical and probe measurement of NO - A comparative study

Measurements were made of NO formation in both subsonic turbulent and nonturbulent media generated from gaseous and liquid fuels. Quartz and metallic, cooled and uncooled probes were employed, and optical measurements were made in the UV with narrow-line and continuum lamps. The extent of systematic error bias in these methods was studied over a wide range of conditions. High resolution measurements were made only on flat flames using a high pressure Xe lamp, while low resolution measurements were done with a hollow cathode lamp on flat flame, swirl burner and jet combustor exhausts. Optical data were reduced using a first principles spectral model and multiple zone treatment of the optical path. No major discrepancies related to processes occurring in probes were identified. Good agreement can be expected in measurements made in subsonic exhaust streams up to 2000 K.

Zabielski, M. F.↗

Solid-state laser sources for remote sensing

Recent progress in slab-geometry and conventional rod Nd:YAG solid-state lasers for applications in remote sensing is presented. Developments in slab geometry lasers, which were aimed at improving pulse energy and tuning range, have been based on the use of a Nd:glass substrate with a zig-zag optical path, with selective Raman shifting in gases and harmonic generation in LiNbO3 and KDP to extend the tuning range into the UV and visible regions. The theoretically predicted advantages of the elimination of birefringence and thermal and stress-induced focusing in the slab-geometry laser have been confirmed in measurements on a test-bed Nd:glass system, and a CW lamp pumped Nd:YAG oscillator, which have also demonstrated an order of magnitude improvement in laser performance. A single axial mode Nd:YAG oscillator has also been designed which, operating in a 3-msec quasi-CW mode, has a chirp rate of 30 kHz/microsec and a free-running stability of + or - 20 MHz. With chirp compensation, this stability is adequate for wind velocity measurements by coherent lidar.

Byer, R. L.↗

RIMSTAR: Rapid image scanning technology and archiving

Conventional schemes for digitizing large volumes of photographic data are far too costly and time consuming to encourage the undertaking of the ambitious projects using traditional technology. There is a distinct need for fast digitizing systems such as could be derived from development of large format, optically multiplexed CCD systems designed to address these problems. The use of CCD chips for data handling and the capability of using polaroids in the optical path for reduced light scattering are discussed.

Craine, E. R.↗

Frost grain size metamorphism - Implications for remote sensing of planetary surfaces

The effective grain size of a material on a planetary surface affects the strength of absorption features observed in the reflectance of a particulate surface. In the case of a planetary surface containing volatile ices, the absorption characteristics can change in connection with processes leading to a change in the grain size of the material. The present investigation is concerned with an evaluation regarding the occurrence of such processes and the implications for remote sensing applications. It is found that quantitative modeling of the kinetics of grain growth and destruction by thermal and nonthermal processes can provide a means to reconcile apparent optical paths in the volatile portions of planetary surfaces with the physical history of those surfaces. Attention is also given to conditions in the case of the Pluto/Triton system, Uranus and Saturnian satellites, and the Galilean system.

Clark, R. N.↗

Null tests for oblate spheroids

In most real cases requiring simple null optics, the optical path difference cannot be reduced to zero but can be kept at a fractional wavelength level so that interferometric data reduction can be used to account for the residual error. In other cases, computer-generated holograms may be used to obtain apparently straight fringes when the desired surface is obtained. Two examples, one involving an f/2.5 concave oblate spheroid and the other a Paul-Baker secondary, are examined. It is shown that although the null tests are not generally perfect, the residual error is small and the tests are simple.

Rodgers, J. M.↗

Turbidity very near the critical point of methanol-cyclohexane mixtures

The turbidity of a critical mixture of methanol and cyclohexane has been measured extremely close to the consolute point. The data span the reduced-temperature range between 10 to the -7th and 10 to the -3d, which is two decades closer to Tc than previous measurements. In this temperature range, the turbidity varies approximately as 1nt, as expected from the integrated form for Ornstein-Zernike scattering. A thin cell (200-micron optical path) with a very small volume (0.08 ml) was used to avoid multiple scattering. A carefully controlled temperature history was used to mix the sample and to minimize the effects of critical wetting layers. The data are consistent with a correlation-length amplitude of 3.9 plus or minus 1.0 A, in agreement with the value 3.5 A calculated from two-scale-factor universality and heat-capacity data from the literature.

Kopelman, R. B.↗