Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Optical Particle Measurements during EPCAPE Field Campaign Report

This campaign requested the deployment of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility optical particle counter (OPC) at the first ARM Mobile Facility (AMF1) located at the Scripps Pier in La Jolla, California during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE). The addition of the OPC was requested for two reasons. (1) Close the gap between the scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) size distribution from the Aerosol Observing System (AOS) measurements. (2) Principal investigator Petters has been working with Tracking Aerosol Convection Interaction Experiment (TRACER) data to compute particle fluxes from Doppler lidar (Petters et al. 2024). Briefly, backscatter flux is obtained using the eddy covariance technique using the Doppler vertical velocity and attenuated backscatter. Building upon prior studies, we were able to relate backscatter to particle number concentration by calibrating the lidar retrievals against optical particle counter-measured ground-based aerosol size distribution and radiosonde-interpolated relative humidity at lidar sample height. Performing similar analysis was of interest to EPCAPE to better understand the emissions and vertical transport of large particles into the overlying stratus clouds. However, as stated above, this analysis requires an optical size distribution that covers the 0.3-30-μm-diameter size range. The OPC was deployed between 2023-04-14 and 2024-02-14. The deployment, data quality analysis, and data archiving was handled by the DOE ARM instrument mentor team without additional involvement by the principal investigator. Data quality was marked as “routine” for the majority of the campaign.

54 ENVIRONMENTAL SCIENCES↗

Proton Dynamics Scenarios in the Integrable Optics Test Accelerator (IOTA) at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab provides a versatile platform for studying the interplay of space-charge, impedance, and non-linear optics in high-intensity hadron beams within synchrotrons and storage rings. This report examines the parameters and dynamics of 2.5~MeV proton beam operations in two configurations of the bare IOTA lattice: one for demonstrating Non-linear Integrable Optics with the Danilov-Nagaitsev magnet, and the other for use with electron cooling. We offer order-of-magnitude estimates of the transverse emittance growth rate as a function of beam intensity, highlighting contributions from residual gas scattering, intra-beam scattering, and space-charge effects. Under nominal conditions, the beam lifetime is projected to be less than 7~minutes at low intensity with the current vacuum quality, and fewer than 100,000~turns at high intensity due to strong space-charge effects. The calculations presented here will guide strategies to mitigate emittance growth and inform future IOTA experiments.

43 PARTICLE ACCELERATORS↗

Steady-State Microbunching using Optical Stochastic Cooling

Optical Stochastic Cooling (OSC) is a state-of-the-art beam cooling technology first demonstrated in 2021 at the IOTA storage ring at Fermilab's FAST facility. A second phase of the research program is planned to run in 2026 and will incorporate an optical amplifier to enable significantly increased cooling rates and greater operational flexibility. In addition to beam cooling, an OSC system can be configured to enable advanced control over the phase space of the beam. An example operational mode could enable crystallization, where the particles in a bunch are locked into a self-reinforcing, regular microstructure at the OSC fundamental wavelength; we refer to this as Optical Stochastic Crystallization (OSX). OSX represents a new path toward Steady-State Microbunching (SSMB), which may enable light sources combining the high brightness of a free-electron laser with the high repetition rate of a storage ring. Such a source has applications from the terahertz to the extreme ultraviolet (EUV), including high-power EUV generation for semiconductor lithography. This contribution will discuss the integration of OSX development as part of the OSC program at IOTA. The design of an accelerator lattice to enable the mechanism and associated high fidelity simulations demonstrating the beam dynamics will be shown, and a path to realizing an experimental demonstration will be discussed.

Wallbank, Michael James [Fermilab]↗

Overview of On-Line Optical Measurements at High Pressure for Flue Gases, Particulates and Acid-dew Point of Pressurized Oxy-Combustion

Optical flow cells are critical measurement interfaces, yet sampling under harsh conditions — high pressure, high temperature, particles, moisture, or corrosive gases — makes it difficult to maintain optical quality without perturbing the measurement. To address this challenge, a new flow cell was developed using a laminar coaxial flow field that separates the purge and sample flows. A dedicated test system was built to evaluate particle size distribution (PSD) measurements using a Malvern Panalytical Insitec analyzer. Results demonstrated that the sample flow alone defines the measurement zone, while the purge flow effectively shields the optical windows from deposition, eliminating sampling bias. The flow cell enables reliable PSD measurement under high pressure and temperature in moist, corrosive environments. As a key demonstration, the instrument was successfully deployed for on-line PSD measurement of flue gas from a 100 kWth pressurized oxy-coal combustor at 15 bara.

Cheng, Mao↗

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Low-cost particulate matter sensors have seen increased use for monitoring at personal and local levels due to their affordability, ease of operation, and high time resolution. However, the quality of data reported by these sensors can be questionable, and a thorough evaluation of their performance is necessary. This study evaluated the particle sizing accuracy of several commonly used optical sensors, including the Alphasense optical particle counter (OPC), TSI DustTrak DRX aerosol monitor, Plantower PMS5003 sensor, and Sensirion SPS30 sensor, using laboratory-generated monodisperse particles. The OPC and DRX agreed partially with reference instruments and showed promise in detecting coarse-size particles. However, the PMS5003 and SPS30 did not correctly size fine and coarse particles. Furthermore, their reported mass distributions do not directly correspond to their number distribution. Despite these limitations, field measurements involving a dust storm period showed that the SPS30 correlated reasonably well with reference instruments for both PM2.5 and PM10, though the regression slopes differed significantly. These findings underscore the need for caution when interpreting data from low-cost optical sensors, particularly for coarse particles. Recommendations for improving the performance of these sensors are also provided.

Gautam, Prakash↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

Efficient Optical Control of Magnon Dynamics in van der Waals Ferromagnets

Optical control of magnons in two-dimensional (2D) materials promises new functionalities for spintronics and magnonics in atomically thin devices. Here, we report control of magnon dynamics, using laser polarization, in a ferromagnetic van der Waals (vdW) material, Fe 3.6 Co 1.4 GeTe 2 . The magnon amplitude, frequency, and lifetime are controlled and monitored by time-resolved pump-probe spectroscopy. We show substantial (over 25%) and continuous modulation of magnon dynamics as a function of incident laser polarization. Our results suggest that the modification of the effective demagnetization field and magnetic anisotropy by the pump laser pulses with different polarizations is due to anisotropic optical absorption. This implies that pump laser pulses modify the local spin environment, which enables the launch of magnons with tunable dynamics. Our first-principles calculations confirm the anisotropic optical absorption of different crystal orientations. Our findings suggest a new route for the development of opto-spintronic or opto-magnonic devices.

36 MATERIALS SCIENCE↗

Enhancing lifetime, forecasting, and economic benefits of photovoltaic technologies undergoing UV-induced degradation with optical filtering

Ultraviolet-induced degradation (UV-ID) of various PV cell types was analyzed under optical UV filters with different cutoff wavelengths. Cell types studied included interdigitated back contact (IBC), passivated emitter and rear totally diffused (PERT), and heterojunction technology (HJT) based on crystalline Si (c-Si), and metal halide perovskite (MHP) cells. Analyzing degradation rates in two distinct regimes proved beneficial for all cell types. We used empirical linearizing functions ln(t) for c-Si technologies and 2 √t for MHP samples where t is time. These were applied to extrapolate UV-induced degradation over the lifetime of PV modules under various levels of optical UV filtering and used to predict the relative economic benefits for PV power plants. Degradation rates for all technologies were generally faster under the long pass optical filters having shorter cutoff wavelengths transmitting more UV irradiation and at elevated temperatures when testing MHP samples in the range between 60 °C and 90 °C.

14 SOLAR ENERGY↗

Optical Photometric Indicators of Galaxy Cluster Relaxation

Abstract The most dynamically relaxed clusters of galaxies play a special role in cosmological studies as well as astrophysical studies of the intracluster medium (ICM) and active galactic nucleus feedback. While high-spatial-resolution imaging of the morphology of the ICM has long been the gold standard for establishing a cluster’s dynamical state, such data are not available from current or planned surveys, and thus require separate, pointed follow-up observations. With optical and/or near-IR photometric imaging, and red-sequence cluster finding results from those data, expected to be ubiquitously available for clusters discovered in upcoming optical and millimeter-wavelength surveys, it is worth asking how effectively photometric data alone can identify relaxed cluster candidates, before investing in, e.g., high-resolution X-ray observations. Here we assess the ability of several simple photometric measurements, based on the redMaPPer cluster finder run on Sloan Digital Sky Survey data, to reproduce X-ray classifications of dynamical state for an X-ray selected sample of massive clusters. We find that two simple metrics contrasting the bright central galaxy (BCG) to other cluster members can identify a complete sample of relaxed clusters with a purity of ∼40% in our data set. Including minimal ICM information in the form of a center position increases the purity to ∼60%. However, all three metrics depend critically on correctly identifying the BCG, which is presently a challenge for optical red-sequence cluster finders.

79 ASTRONOMY AND ASTROPHYSICS↗

Realizing Steady-State Microbunching with Optical Stochastic Crystallization

Optical Stochastic Cooling (OSC) is a state-of-the-art beam cooling technology first demonstrated in 2021 at the IOTA storage ring at Fermilab's FAST facility. A second phase of the research program is planned to run in early 2025 and will incorporate an optical amplifier to enable significantly increased cooling rates and greater operational flexibility. In addition to beam cooling, an OSC system can be configured to enable advanced control over the phase space of the beam. An example operational mode could enable crystallization, where the particles in a bunch are locked into a self-reinforcing, regular microstructure at the OSC fundamental wavelength; we refer to this as Optical Stochastic Crystallization (OSX). OSX represents a new path toward Steady-State Microbunching (SSMB), which may enable light sources combining the high brightness of a free-electron laser with the high repetition rate of a storage ring. Such a source has applications from the terahertz to the extreme ultraviolet (EUV), including high-power EUV generation for semiconductor lithography. This contribution will discuss the status of the OSC experimental program and its potential to achieve the first demonstration of SSMB during the upcoming experimental run.

43 PARTICLE ACCELERATORS↗

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record↗

Polarizing 3 He via metastability exchange optical pumping using a 1.2 mbar sealed cell at magnetic fields up to 5 T

Here, we report high nuclear polarization of 1.2 mbar 3 He gas in a sealed cell in magnetic fields up to 5 T using Metastability Exchange Optical Pumping (MEOP). The creation of a highly polarized 3 He gas target for use in the 5 T field of Jefferson Lab’s CLAS12 spectrometer would enable new studies of spin-dependent asymmetries on the neutron. We describe a systematic study which was conducted for the first time up to the full 5 T field required for the final target design to evaluate the effects of discharge intensity, pump laser power, and optical pumping transition schemes on nuclear polarization and pumping rates. Steady-state polarizations up to 86% in magnetic fields between 2 and 5 T were achieved, with a discharge-on relaxation time of 898 s at 5 T. These results underscore the potential of MEOP for high-field applications in nuclear physics experiments.

3He polarization↗

Directionally asymmetric nonlinear optics in ferrorotational MnTiO 3

Ferrorotationally ordered materials possess a planar chiral lattice of electric dipoles that are a promising platform for exhibiting directionally asymmetric response functions. A key characteristic of such order is that enantiomorph conversion occurs when the solid is flipped by 180° about an in-plane axis. Using second-harmonic interferometry, we show here that when circularly polarized light is incident on MnTiO 3 , the generated harmonic intensity depends on whether the incident light is parallel or antiparallel to the ferrorotational axis. For a particular photon helicity, constructive interference occurs in one direction while destructive interference occurs in the other. Here, our observations represent a fundamentally new optical effect, associated with circularly polarized light in ferrorotational solids, that is distinct from conventional optical activity observed in three-dimensional chiral and Faraday media.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical functions of uniaxial rutile and anatase (TiO 2 ) revisited

In this study, the optical functions of uniaxial rutile and anatase (TiO2) were determined from 200 to 850 nm (6.2 to 1.46 eV) using several of four optical techniques: (1) standard spectroscopic two-modulator generalized ellipsometry (2-MGE), (2) near-normal-incidence two-modulator generalized ellipsometry microscopy (2-MGEM), (3) Mueller matrix transmission of rutile, and (4) polarized transmission of rutile. The 2-MGE measurements yielded highly accurate values of the dielectric functions and error estimates from 1.46 to 6.2 eV, whereas the polarization-dependent transmission yielded more accurate values of the absorption coefficient below the band edge of rutile. The 2-MGEM also measured the diattenuation, which is related to the birefringence, and other parameters but at near-normal incidence at a single wavelength (577 nm).

36 MATERIALS SCIENCE↗

Utah FORGE: Well 16B(78)-32 DTS, RFS DSS Strain, and Absolute Strain Circulation Test Fiber Optic Data - August 2024

This dataset contains processed fiber optic measurements collected during the extended cross-well circulation test at the Utah FORGE site in August 2024. The data was acquired from the 16B(78)-32 well using distributed fiber optic sensing (DFOS) technology, including distributed temperature sensing (DTS) on multimode fiber and distributed strain sensing (DSS) measurements on single-mode fiber. The dataset includes Brillouin absolute strain, Rayleigh frequency shift (RFS) DSS strain change, RFS DSS strain change rate, and temperature (DTS) data, all stored in HDF5 format. Time coordinates are provided in UTC, and depth measurements are given in measured depth relative to the rotary kelly bushing (MD RKB) in feet. The spatial sampling on the RFS DSS strain data and the Brillouin Absolute Total Strain data is 20 cm and the spatial sampling on the DTS data is 1m. The dataset is accompanied by a report from Neubrex, which provides further documentation.

15 GEOTHERMAL ENERGY↗

Commercialization of Reflected Target Non-Intrusive Assessment (ReTNA) Tool, for Indoor Optical Analysis of Heliostats

Under HelioCon, NLR began developing a new optical measurement system, called Reflected Target Non-Intrusive Assessment (ReTNA). ReTNA has shown promise towards addressing metrology gaps for heliostat used in concentrated solar thermal (CST) plant. This project is focused on advancing this measurement system from the laboratory into industry, where it can provide valuable information for heliostat developers during research, development, and qualification of a heliostat design, and be used for quality assurance during heliostat manufacture. Over the course of this project, ReTNA was deployed at several commercial heliostat facilities. The system developed and deployed with the primary project partner, Solar Dynamics LLC, is described in detail. The report discusses each project Milestone, the ending status, the achieved value, and how these Milestones improve and qualify the ReTNA measurement tool. Finally, the final report covers the market advancements, path forward, commercial successes, and lessons learned. Final Technical report for TCF Base Technology-Specific project TCF-23-20118, Commercialization of Reflected Target Non-Intrusive Assessment (ReTNA) tool, for indoor optical analysis of Heliostats.

14 SOLAR ENERGY↗

Optical image analysis for graphene layer detection: Enhanced green channel methodology

Graphene, a material of increasing research interest, requires accurate layer identification due to its sensitivity to layer count. Existing methods for graphene layer number identification are either time-consuming or of low accuracy, with high-accuracy methods often requiring expensive processes. This paper aims to address this challenge by proposing a cost-effective and efficient approach. Specifically, the current work highlights only the green channel—one of the three primary color channels (red, green, blue) that make up an optical image—from images of exfoliated graphene flakes for layer count identification. A linear regression is performed between pixel position and substrate green channel value, and this effect is subtracted from the entire optical image to mitigate background effects. By storing the range of green channel values for each type of flake (monolayer, bilayer, or tri-layer) based on a few images, we establish thresholds for identifying different types of layers in a particular setup. Additionally, our methodology allows for flexible threshold tuning using a single reference image, enabling adjustment to changes in detection setup such as illumination level, magnification, or microscope used. Finally, demonstrating high accuracy and flexibility, this methodology presents a suitable technique for graphene layer number identification without the need for large datasets or expensive instruments.

2D materials↗

Glassy carbon formation from pyrolysis of polymeric coatings on fiber-optic sensors

Deploying fiber-optic sensors in nuclear reactors requires a detailed understanding of radiation effects on the fiber materials and the transmitted signals. Previous work has shown large wavelength shifts in the reflected spectra obtained from polymer-coated fiber-optic temperature sensors exposed to high neutron fluences. The sensor drift resulting from these wavelength shifts cannot be explained by radiation effects on fused silica glass. These shifts are hypothesized to be caused by the conversion of the polymeric fiber coating to a glassy carbon via radiolysis and/or pyrolysis and subsequent radiation-induced compaction. Here, thermal degradation of these polymeric coatings was studied to provide insight into the potential origins of the sensor drift phenomenon. Acrylate- and polyimide-coated fibers were heated under various temperatures (250–1300 °C) and environments (oxidative and inert), and the resulting coating products were characterized via mass-loss data, scanning electron microscope imaging, and Raman spectroscopy. Results suggest that the polymer decomposition product of both coating types, at least under inert conditions, is indeed a glassy carbon. Analytical models that account for radiation-induced glassy carbon coating compaction show significant compressive fiber strains and predicted wavelength shifts that agree well with experimental measurements, providing additional evidence that supports the hypothesized origins of the sensor drift.

36 MATERIALS SCIENCE↗