Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A high-fidelity residential building occupancy detection dataset

Abstract This paper describes development of a data acquisition system used to capture a range of occupancy related modalities from single-family residences, along with the dataset that was generated. The publicly available dataset includes: grayscale images at 32-by-32 pixels, captured every second; audio files, which have undergone processing to remove personally identifiable information; indoor environmental readings, captured every ten seconds; and ground truth binary occupancy status. The data acquisition system, coined the mobile human presence detection (HPDmobile) system, was deployed in six homes for a minimum duration of one month each, and captured all modalities from at least four different locations concurrently inside each home. The environmental modalities are available as captured, but to preserve the privacy and identity of the occupants, images were downsized and audio files went through a series of processing steps, as described in this paper. This dataset adds to a very small body of existing data, with applications to energy efficiency and indoor environmental quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Singleplex, multiplex and pooled sample real-time RT-PCR assays for detection of SARS-CoV-2 in an occupational medicine setting

Abstract For workplaces which cannot operate as telework or remotely, there is a critical need for routine occupational SARS-CoV-2 diagnostic testing. Although diagnostic tests including the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (CDC Diagnostic Panel) (EUA200001) were made available early in the pandemic, resource scarcity and high demand for reagents and equipment necessitated priority of symptomatic patients. There is a clearly defined need for flexible testing methodologies and strategies with rapid turnaround of results for (1) symptomatic, (2) asymptomatic with high-risk exposures and (3) asymptomatic populations without preexisting conditions for routine screening to address the needs of an on-site work force. We developed a distinct SARS-CoV-2 diagnostic assay based on the original CDC Diagnostic Panel (EUA200001), yet, with minimum overlap for currently employed reagents to eliminate direct competition for limited resources. As the pandemic progressed with testing loads increasing, we modified the assay to include 5-sample pooling and amplicon target multiplexing. Analytical sensitivity of the pooled and multiplexed assays was rigorously tested with contrived positive samples in realistic patient backgrounds. Assay performance was determined with clinical samples previously assessed with an FDA authorized assay. Throughout the pandemic we successfully tested symptomatic, known contact and travelers within our occupational population with a ~ 24–48-h turnaround time to limit the spread of COVID-19 in the workplace. Our singleplex assay had a detection limit of 31.25 copies per reaction. The three-color multiplexed assay maintained similar sensitivity to the singleplex assay, while tripling the throughput. The pooling assay further increased the throughput to five-fold the singleplex assay, albeit with a subtle loss of sensitivity. We subsequently developed a hybrid ‘multiplex-pooled’ strategy to testing to address the need for both rapid analysis of samples from personnel at high risk of COVID infection and routine screening. Herein, our SARS-CoV-2 assays specifically address the needs of occupational healthcare for both rapid analysis of personnel at high-risk of infection and routine screening that is essential for controlling COVID-19 disease transmission. In addition to SARS-CoV-2 and COVID-19, this work demonstrates successful flexible assays developments and deployments with implications for emerging highly transmissible diseases and future pandemics.

60 APPLIED LIFE SCIENCES↗

Simultaneous occupancy of Cu C and Cu D in the ammonia monooxygenase active site

Ammonia monooxygenase (AMO), a copper-dependent membrane enzyme, catalyzes the first and rate-limiting step of nitrification: the oxidation of ammonia to hydroxylamine. Despite its central role in the global nitrogen cycle and its biotechnological relevance, structural characterization of AMO has lagged behind that of its homolog, particulate methane monooxygenase (pMMO), due to the slow growth rates of ammonia-oxidizing bacteria and the instability of AMO upon purification. Recent cryoEM studies of Nitrosomonas europaea AMO and Methylococcus capsulatus (Bath) pMMO in native membranes revealed new structural features, including two adjacent copper-binding sites in the transmembrane region, Cu C and Cu D , believed to constitute the active site. Although multiple structures were determined under various conditions, simultaneous occupancy of Cu C and Cu D was never observed, leaving their potential functional interplay unresolved. Here we report the 2.6 Å resolution cryoEM structure of AMO from Nitrosospira briensis C-128 in isolated native membranes. This structure reveals the first instance of simultaneous copper occupancy of the Cu C and Cu D sites, along with occupancy of the periplasmic Cu B site. Electron paramagnetic resonance (EPR) spectroscopic data indicate that the Cu B site is primarily occupied by Cu(II), while Cu C and Cu D are primarily occupied by diamagnetic ions, presumably Cu(I). Notably, a lipid molecule is bound between the Cu C and Cu D sites, separating them by ∼8.0 Å. The results underscore the importance of studying these enzymes in their native environments across species to resolve conserved and divergent molecular features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE HALO OCCUPATION DISTRIBUTION OF SDSS QUASARS

We present an estimate of the projected two-point correlation function (2PCF) of quasars in the Sloan Digital Sky Survey (SDSS) over the full range of one- and two-halo scales, 0.02 h{sup -1} Mpc < r{sub p} < 120 h{sup -1} Mpc. This was achieved by combining data from SDSS DR7 on large scales and Hennawi et al. (with appropriate statistical corrections) on small scales. Our combined clustering sample is the largest spectroscopic quasar clustering sample to date, containing {approx}48, 000 quasars in the redshift range 0.4 {approx}< z {approx}< 2.5 with median redshift 1.4. We interpret these precise 2PCF measurements within the halo occupation distribution (HOD) framework and constrain the occupation functions of central and satellite quasars in dark matter halos. In order to explain the small-scale clustering, the HOD modeling requires that a small fraction of z {approx} 1.4 quasars, f{sub sat} = (7.4 {+-} 1.4) Multiplication-Sign 10{sup -4}, be satellites in dark matter halos. At z {approx} 1.4, the median masses of the host halos of central and satellite quasars are constrained to be M{sub cen} = 4.1{sup +0.3}{sub -0.4} Multiplication-Sign 10{sup 12} h{sup -1} M{sub Sun} and M{sub sat} = 3.6{sup +0.8}{sub -1.0} Multiplication-Sign 10{sup 14} h{sup -1} M{sub Sun }, respectively. To investigate the redshift evolution of the quasar-halo relationship, we also perform HOD modeling of the projected 2PCF measured by Shen et al. for SDSS quasars with median redshift 3.2. We find tentative evidence for an increase in the mass scale of quasar host halos-the inferred median mass of halos hosting central quasars at z {approx} 3.2 is M{sub cen} = 14.1{sup +5.8}{sub -6.9} Multiplication-Sign 10{sup 12} h{sup -1} M{sub Sun }. The cutoff profiles of the mean occupation functions of central quasars reveal that quasar luminosity is more tightly correlated with halo mass at higher redshifts. The average quasar duty cycle around the median host halo mass is inferred to be f{sub q} = 7.3{sup +0.6}{sub -1.5} Multiplication-Sign 10{sup -4} at z {approx} 1.4 and f{sub q} = 8.6{sup +20.4}{sub -7.2} Multiplication-Sign 10{sup -2} at z {approx} 3.2. We discuss the implications of our results for quasar evolution and quasar-galaxy co-evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

THE HALO OCCUPATION DISTRIBUTION OF X-RAY-BRIGHT ACTIVE GALACTIC NUCLEI: A COMPARISON WITH LUMINOUS QUASARS

We perform halo occupation distribution (HOD) modeling of the projected two-point correlation function (2PCF) of high-redshift (z {approx} 1.2) X-ray-bright active galactic nuclei (AGNs) in the XMM-COSMOS field measured by Allevato et al. The HOD parameterization is based on low-luminosity AGNs in cosmological simulations. At the median redshift of z {approx} 1.2, we derive a median mass of 1.02{sub -0.23}{sup +0.21} Multiplication-Sign 10{sup 13} h{sup -1} M{sub sun} for halos hosting central AGNs and an upper limit of {approx}10% on the AGN satellite fraction. Our modeling results indicate (at the 2.5{sigma} level) that X-ray AGNs reside in more massive halos compared to more bolometrically luminous, optically selected quasars at similar redshift. The modeling also yields constraints on the duty cycle of the X-ray AGN, and we find that at z {approx} 1.2 the average duration of the X-ray AGN phase is two orders of magnitude longer than that of the quasar phase. Our inferred mean occupation function of X-ray AGNs is similar to recent empirical measurements with a group catalog and suggests that AGN halo occupancy increases with increasing halo mass. We project the XMM-COSMOS 2PCF measurements to forecast the required survey parameters needed in future AGN clustering studies to enable higher precision HOD constraints and determinations of key physical parameters like the satellite fraction and duty cycle. We find that N {sup 2}/A {approx} 5 Multiplication-Sign 10{sup 6} deg{sup -2} (with N the number of AGNs in a survey area of A deg{sup 2}) is sufficient to constrain the HOD parameters at the 10% level, which is easily achievable by upcoming and proposed X-ray surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

The DESI One-Percent survey: exploring the Halo Occupation Distribution of Emission Line Galaxies with AbacusSummit simulations

The One-Percent survey of the Dark Energy Spectroscopic Instrument collected ~ 270k emission line galaxies (ELGs) at 0.8 < z < 1.6. The high completeness of the sample allowed the clustering to be measured down to scales never probed before, 0.04 Mpc/h in rp for the projected 2-point correlation function (2PCF) and 0.17 Mpc/h in galaxy pair separation s for the 2PCF monopole and quadrupole. The most striking feature of the measurements is a strong signal at the smallest scales, below 0.2 Mpc/h in rp and 1 Mpc/h in s. We analyse these data in the halo occupation distribution framework. We consider different distributions for central galaxies, a standard power law for satellites with no condition on the presence of a central galaxy and explore several extensions of these models. For all considered models, the mean halo mass of the sample is found to be log10 $\langle$Mh$\rangle$ ~ 11.9. We obtain a satellite mean occupation function which agrees with physically motivated ELG models only if we introduce central-satellite conformity, meaning that the satellite occupation is conditioned by the presence of central galaxies of the same type. To achieve in addition a good modelling of the clustering between 0.1 and 1 Mpc/h in rp, we allow for ELG positioning outside of the halo virial radius and find 0.5% of ELGs residing in the outskirts of halos. Furthermore, the satellite velocity dispersion inside halos is found to be ~ 30% larger than that of the halo dark matter particles. These are the main findings of our work. Here we investigate assembly bias as a function of halo concentration, local density or local density anisotropies and observe no significant change in our results. We split the data sample in two redshift bins and report no significant evolution with redshift. Lastly, changing the cosmology in the modelling impacts only slightly our results.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-dependent occupation numbers in reduced-density-matrix-functional theory: Application to an interacting Landau-Zener model

We prove that if the two-body terms in the equation of motion for the one-body reduced density matrix are approximated by ground-state functionals, the eigenvalues of the one-body reduced density matrix (occupation numbers) remain constant in time. This deficiency is related to the inability of such an approximation to account for relative phases in the two-body reduced density matrix. We derive an exact differential equation giving the functional dependence of these phases in an interacting Landau-Zener model and study their behavior in short- and long-time regimes. The phases undergo resonances whenever the occupation numbers approach the boundaries of the interval [0,1]. In the long-time regime, the occupation numbers display correlation-induced oscillations and the memory dependence of the functionals assumes a simple form.

74 ATOMIC AND MOLECULAR PHYSICS↗

Entanglement entropy, single-particle occupation probabilities, and short-range correlations

For quantum many-body systems with short-range correlations (SRCs), the intimate relationship between their magnitude, the behavior of the single-particle occupation probabilities at momenta larger than the Fermi momentum, and the entanglement entropy is a new qualitative aspect not studied and exploited yet. A large body of recent condensed matter studies indicates that the time evolution of the entanglement entropy describes the nonequilibrium dynamics of isolated and strongly interacting many-body systems, in a manner similar to the Boltzmann entropy, which is strictly defined for dilute and weakly interacting many-body systems. Both theoretical and experimental studies in nuclei and cold atomic gases have shown that the fermion momentum distribution has a generic behavior n(k)=C/k 4 at momenta larger than the Fermi momentum, due to the presence of SRCs, with approximately 20% of the particles having momenta larger than the Fermi momentum. Further, the presence of the long momentum tails in the presence of SRCs changes the textbook relation between the single-particle kinetic energy and occupation probabilities, n mf ⁡(k) = 1/{1+ exp ⁡β[ϵ⁡(k)-μ]} for momenta very different form the Fermi momentum, particularly for dynamics processes. SRCs induced high-momentum tails of the single-particle occupation probabilities increase the entanglement entropy of fermionic systems, which in its turn affects the dynamics of many nuclear reactions, such as heavy-ion collisions and nuclear fission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of hydrogen site and occupancy in hydrous Mg 2 SiO 4 spinel by single-crystal neutron diffraction

Ringwoodite [(Mg,Fe 2+ ) 2 SiO 4 spinel] has been considered as one of the most important host minerals of water in the Earth's deep mantle. Its extensive hydration was observed in high-pressure synthesis experiments and also by its natural occurrence. Water can dissolve into ringwoodite as structurally bound hydrogen cations by substituting other cations, although the hydrogen site and its occupancy remain unclear. In this study, neutron time-of-flight single-crystal Laue diffraction analysis was carried out for synthetic hydrous ringwoodite. Hydrogen cations were found only in the sites in MgO 6 octahedra in the ringwoodite structure, which compensated the reduced occupancies of both magnesium and silicon cations. The refined cation occupancies suggest that the most plausible hydration mechanism is that three hydrogen cations simultaneously occupy an MgO 6 octahedron, whereas four such hydrogenated octahedra surround a vacant SiO 4 tetrahedron.

36 MATERIALS SCIENCE↗

Fault Detection via Occupation Kernel Principal Component Analysis

Reliable operation of automatic systems is heavily dependent on the ability to detect faults in the underlying dynamics. While traditional model-based methods have been widely used for fault detection, data-driven approaches have garnered increasing attention due to their ease of deployment and minimal need for expert knowledge. In this letter, we present a novel principal component analysis (PCA) method that uses occupation kernels. Occupation kernels result in feature maps that are tailored to the measured data, have inherent noise-robustness due to the use of integration, and can utilize irregularly sampled system trajectories of variable lengths for PCA. The occupation kernel PCA method is used to develop a reconstruction error approach to fault detection and its efficacy is validated using numerical simulations.

42 ENGINEERING↗

OpenStudio-Occupant-Variability-Gem v1.0

This gem contains methods to introduce occupant-related variability to extend core OpenStudio SDK. The goal of introducing the variability is to improve the assumptions related to stochastic occupant movement, occupant-related lighting and electric equipment, and thermostat set points schedules in traditional OpenStudio and EnergyPlus models.

Li, Han↗

Occupational Experience Effects on Physiological and Perceptual Responses of Common Soldiering Tasks

Abstract Cohen BS, Redmond JE, Haven CC, Foulis SA, Canino MC, Frykman PN, Sharp MA. Occupational Experience Effects on Physiological and Perceptual Responses of Common Soldiering Tasks. J Strength Cond Res 37(4): 894–901, 2023—This study measured the impact of occupational experience (i.e., time spent deployed, in military service, and in job and task performance frequency in training, deployment, and study practice) on the physiological (heart rate [HR] and oxygen consumption [VO 2 ]) and perceptual (rate of perceived exertion [RPE]) responses to performance of critical physically demanding tasks (CPDTs). Five CPDTs (road march, build a fighting position, move under fire, evacuate a casualty, and drag a casualty to safety), common to all soldiers, were performed by 237 active duty soldiers. Linear regression models examined the association between measures of experience and physiological and perceptual performance responses to task demands. The level of significance was adjusted for multiple comparisons and set at ρ ≤ 0.0125 for this study. Significant and notable effect sizes included the impact of time spent deployed on the physiological measures of the road march (PostHR F = 24.84, p < 0.0001, β=-9.65), sandbag fill (PostHR F = 8.26, p = 0.005, β = −2.83), and sandbag carry (MeanHR F = 7.51, p = 0.007, β = −1.12; PostHR F = 7.35, p = 0.007, β = −0.87). For the road march task, there was a nearly 10 bpm decrease in postperformance HR for every year spent deployed. Road march, sandbag fill, and sandbag carry tasks PostHRs were also notably negatively associated with the experience measures of time in their MOS (job and time in military service but not for other physiological and perceptual responses, including VO 2 and RPE. Frequency of task performance in training, deployment, and study practice was not meaningfully associated with experience. The results suggest that increasing task familiarization through on-the-job occupational operational experience may result in greater proficiency and reduced physiological effort.

Sport Sciences↗

Assessing Occupant and Outdoor Air Impacts on Indoor Air Quality in New California Homes

In 2008 the State of California adopted new building codes that required the use of mechanical ventilation systems in homes that meet the requirements of ASHRAE Standard 62.2. The standard requires both a dwelling unit mechanical ventilation system and exhaust fans in kitchens and bathrooms. A field study was undertaken to evaluate the IAQ and ventilation performance of homes built to these requirements. For ventilation system performance, the airflows of all mechanical ventilation systems were measured and their use was monitored for a one-week period. To evaluate IAQ, key pollutants were measured indoors and outdoors during the week, and occupants completed satisfaction surveys. The key pollutants included: formaldehyde, humidity, PM2.5 and NO2. Passive samplers were used to determine average concentrations for the week. Active samplers were used to develop time-series results that can be used to correlate pollutant concentrations with occupant activities. Other ventilation/IAQ related parameters were also recorded, such as stove top temperatures to indicate cooking, exterior door contact switches to know when large openings were being used for ventilation and sensors to determine when clothes dryers were being used. The building envelope and duct leakage were measured to enable estimates of infiltration and duct leakage effects. This paper presents an overview of the test procedures and preliminary results from several homes. The results show that although average concentrations may be reasonable compared to available standards (with the exception of formaldehyde), occupants have a strong impact on pollutant variability and source strength and that outdoor concentrations cannot be ignored. Overall, these mechanically ventilated homes have reasonable IAQ. The homes and duct systems are moderately tight, though not excessively so, by US standards. Significant concerns have been expressed regarding compliance with the ventilation requirements in the California building code. However, almost all the ventilation systems in this study complied with the ventilation air flow requirements and on average were significantly higher than the minimum required air flow rates.

Walker, IS↗

Review of Literature on Terminal Box Control, Occupancy Sensing Technology and Multi-zone Demand Control Ventilation (DCV)

This report presents an overall review of the standard requirement, the terminal box control, occupancy sensing technology and DCV. There is system-specific guidance for single-zone systems, but DCV application guidance for multi-zone variable air volume (VAV) systems is not available. No real-world implementation case studies have been found using the CO 2 -based DCV. The review results also show that the constant minimum air flow set point causes excessive fan power consumption and potential simultaneous heating and cooling. Occupancy-based control (OBC) is needed for the terminal box in order to achieve deep energy savings. Key to OBC is a technology for sensing the actual occupancy of the zone served in real time. Several technologies show promise, but none currently fully meets the need with adequate accuracy and sufficiently low cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes – such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study’s results will be used to identify cost-effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot, Cold, or Just Right? Using a Wide-View Infrared Biometric Sensor to Improve Occupant Comfort and Reduce Overcooling in Buildings via Closed-loop Control (CRADA Final Report)

This research adds to the understanding of building energy management by fundamentally challenging the long-standing paradigm of controlling an environmental parameter—air temperature—and assuming occupant comfort will follow. The project developed and demonstrated a novel approach that directly senses physiological indicators of human comfort to enable closedloop, human-centric control of heating, ventilation, and air conditioning (HVAC) systems. This work shifts the focus from open-loop environmental control to a closed-loop system that prioritizes the occupants' actual thermal state. The primary benefit to the public is the potential for a simultaneous improvement in the quality of indoor environments, where people spend most of their time, and a significant reduction in national energy consumption. Overcooling, or the overuse of cooling energy in a way that discomforts occupants, wastes approximately 0.5 Quads of primary energy annually in U.S. commercial buildings and creates unproductive indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗