Tracking Study for Top-off Safety Validation at SSRL

A tracking study was performed at SSRL to identify necessary controls and to prove the safety of top-off operation from radiation hazard under such conditions. The safety rationale, tracking setup and the results are presented. Top-off operational mode has become a trend for existing and planned third-generation storage ring light sources for the many benefits such as increased average brightness, improved thermal stability and elimination of the interruption to user experiments due to traditional injection [1, 2]. Unlike the traditional decay mode injection which happens a few times a day and during which the photon beamline shutters are closed, top-off mode injection requires photon beamline shutters to remain open during injection and occurs much more frequently, from once every 5 seconds to once every 30 minutes. Therefore injection may be transparent to user experiments and the stored current variation can be significantly reduced. For a facility equipped with a full-energy injector, the biggest challenge to the implementation of the top-off mode may be the control of radiation hazard. Studies at ALS and SSRL [2, 3] have shown that a single injected electron pulse that enters the photon beamline and exits the radiation shield wall would cause unacceptable radiation doses on the experimental floor. For the protection of users and experimental equipment, it is hence a prerequisite for top-off operation to establish controls that absolutely prevent such occurrences. Similar to other facilities such as ALS and APS [2, 4], tracking simulations were conducted at SSRL to identify the control measures, define the specifications and prove the radiation safety. However, a different approach toward the proof of safety is taken at SSRL. In this paper we first describe the SSRL accelerator complex with emphasis on the aspects related to top-off in section 2. The general considerations and requirements for top-off are presented in section 3. Section 4 and 5 give a detailed description of the tracking setup and results. Concluding remarks are given in section 6.

43 PARTICLE ACCELERATORS↗

ISHM Decision Analysis Tool: Operations Concept

The state-of-the-practice Shuttle caution and warning system warns the crew of conditions that may create a hazard to orbiter operations and/or crew. Depending on the severity of the alarm, the crew is alerted with a combination of sirens, tones, annunciator lights, or fault messages. The combination of anomalies (and hence alarms) indicates the problem. Even with much training, determining what problem a particular combination represents is not trivial. In many situations, an automated diagnosis system can help the crew more easily determine an underlying root cause. Due to limitations of diagnosis systems,however, it is not always possible to explain a set of alarms with a single root cause. Rather, the system generates a set of hypotheses that the crew can select from. The ISHM Decision Analysis Tool (IDAT) assists with this task. It presents the crew relevant information that could help them resolve the ambiguity of multiple root causes and determine a method for mitigating the problem. IDAT follows graphical user interface design guidelines and incorporates a decision analysis system. I describe both of these aspects.

Source record↗

Research on Hazardous States of Awareness and Physiological Factors in Aerospace Operations

The technical memorandum describes research conducted to examine the etiologies and nature of hazardous states of awareness and the psychophysiological factors involved in their onset in aerospace operations. A considerable amount of research has been conducted at NASA that examines psychological and human factors issues that may play a role in aviation safety. The technical memorandum describes some of the research that was conducted between 1998 and 2001, both in-house and as cooperative agreements, which addressed some of these issues. The research was sponsored as part of the physiological factors subelement of the Aviation Operation Systems (AOS) program and Physiological / Psychological Stressors and Factors project. Dr. Lance Prinzel is the Level III subelement lead and can be contacted at l.j.prinzel@larc.nasa.gov.

Prinzel, Lawrence J., III↗

Glenn Extreme Environments Rig (GEER) Independent Review

The Chief of the Space Science Project Office at Glenn Research Center (GRC) requested support from the NASA Engineering and Safety Center (NESC) to satisfy a request from the Science Mission Directorate (SMD) Associate Administrator and the Planetary Science Division Chief to obtain an independent review of the Glenn Extreme Environments Rig (GEER) and the operational controls in place for mitigating any hazard associated with its operation. This document contains the outcome of the NESC assessment.

Jankovsky, Robert S.↗

Thunderstorm currents and lightning charges at the NASA Kennedy Space Center

The NASA Kennedy Space Center, (KSC) and the U.S. Air Force are currently operating an extensive network of ground-based electric-field mills in order to detect atmospheric electrical hazards to ground operations, launches, and landings of spacecraft. Over the past 10 years, the University of Arizona has utilized data provided by this network, and other instrumentation, to investigate the electrical structure of thunderstorms and lightning in Florida. Recent analyses have included estimates of the Maxwell current density that thunderstorms produce at the ground and computations of the locations and magnitudes of lightning-caused changes in the cloud charge distribution. This work is reviewed, and an example of how thunderstorm current patterns and lightning charges develop in both space and time is presented.

Krider, E. P.↗

Glovebox Handling of High-Consequence Materials with Super Baxter and Gesture-Based Programming - 18598

The handling of high-consequence materials is a difficult task requiring safe object manipulation while avoiding the risk of contamination or spillage. Specific operations including opening containers, segregating the wastes, and repackaging are required to be safely executed inside contained spaces such as gloveboxes. However, the workers' ability and dexterity to manipulate objects through thick protective gloves are compromised in many aspects. The fixed position of the glovebox arm ports restricts the movements of the workers' arms, which also makes it hard to lift heavy objects. Further, the operational workspace inside the glovebox is restricted by the gloves' reachability. Safety of workers is the paramount concern in glovebox operations and the very reason for their existence. Sharp edges and tools increases the risk of glove punctures, which may expose the operator to chemicals and radiation and risks contamination in the vicinity outside the glovebox. The operators are also affected by ergonomic stressors due to prolonged and repetitive operations. To achieve a high degree of human safety, robotic solutions to handle high-consequence materials inside the glovebox are desirable, as they remove the operators from the hazards listed above. However, robots, in general, lack the degree of adaptability necessary for most high-consequence material handling tasks as these tasks are often unstructured or highly variable. Likewise, most human operators, while highly skilled in the tasks at hand (task expertise), lack the robot programming skills necessary to adapt the robot's motions to the variations (programming expertise). A way to bridge this divide is to make robot programming more intuitive to human operators. Since humans naturally teach one another through demonstration and learning, robotic 'programming by demonstration' paradigms have begun to appear to reduce the burden of robot reprogramming. Gesture-Based Programming attempts to achieve that by enabling a robot to observe the normal actions and affordances of a human performing a task to learn to map those onto the skills of the robot. In the end, this approach permits benefits from both the human and the robot: the human's adaptive decision making and the robot's resilience to high-consequence material. Robotic solutions assuringly provide protection for the operators, however their autonomy brings about other potential risks. Artificial Intelligence is not perfect; it is a black box, which can produce results, but the full extent of those results may not be known precisely. In self-driving cars, a hypothetical AI problem is the 'green man detector'. Since self-driving cars have presumably never seen a green man, how can we know it won't veer toward him the first time it sees a green man? Likewise, even though GbP provides an open method for safe task execution replicating a human, incorrect task inferences can lead to potential collisions or unintended operations. Thus, a hardware safety measure is proposed to provide reliable operation inside the glovebox, and true safe operations are achieved by mechanically limiting the operational range of each arm link. The operational range is computed and validated through exhaustive offline simulations, which can be streamlined by affordable computing power. Super Baxter is one such robot which incorporates these capabilities. It is a human-like, bimanual robot, being developed at the Collaborative Robotics Lab (CRL) in conjunction with the Dept. of Energy/Environmental Management, Rethink Robotics, Barrett Technology, and the NSF Center for Robots and Sensors for the Human Well-Being (RoSe-HUB). Super Baxter is envisioned to represent the next generation of collaborative robots that will be intrinsically human-safe, as well as exceptionally human-intuitive. In summary, Super Baxter will enable safe glovebox operations through low-shot Gesture based Programming incorporated with hardware safety measures. Two aspects of safety will be discussed in the paper. First, the safety of the operator achieved by allowing him to program Super Baxter remotely through Gesture based Programming. Second, the safety of the glovebox, achieved by incorporating hardware safety measures using joint limits. Further, the capability of Super Baxter on Gesture based Programming is demonstrated through typical object manipulation tasks in glovebox operations. (authors)

42 ENGINEERING↗

Tools to Address Glare and Avian Flux Hazards from Solar Energy Systems

This report describes software tools that can be used to evaluate and mitigate potential glare and avian-flux hazards from photovoltaic and concentrating solar power (CSP) plants. Enhancements to the Solar Glare Hazard Analysis Tool (SGHAT) include new block-space receptor models, integration of PVWatts for energy prediction, and a 3D daily glare visualization feature. Tools and methods to evaluate avian-flux hazards at CSP plants with large heliostat fields are also discussed. Alternative heliostat standby aiming strategies were investigated to reduce the avian-flux hazard and minimize impacts to operational performance. Finally, helicopter flyovers were conducted at the National Solar Thermal Test Facility and at the Ivanpah Solar Electric Generating System to evaluate the alternative heliostat aiming strategies and to provide a basis for model validation. Results showed that the models generally overpredicted the measured results, but they were able to simulate the trends in irradiance values with distance. A heliostat up-aiming strategy is recommended to alleviate both glare and avian-flux hazards, but operational schemes are required to reduce the impact on heliostat slew times and plant performance. Future studies should consider the trade-offs and collective impacts on these three factors of glare, avian-flux hazards, and plant operations and performance.

14 SOLAR ENERGY↗

Critical Drivers for Safety Culture: Examining Department of Energy and U.S. Army Operational Experiences - 12382

Evaluating operational incidents can provide a window into the drivers most critical to establishing and maintaining a strong safety culture, thereby minimizing the potential project risk associated with safety incidents. By examining U.S. Department of Energy (DOE) versus U.S. Army drivers in terms of regulatory and contract requirements, programs implemented to address the requirements, and example case studies of operational events, a view of the elements most critical to making a positive influence on safety culture is presented. Four case studies are used in this evaluation; two from DOE and two from U.S. Army experiences. Although the standards guiding operations at these facilities are different, there are many similarities in the level of hazards, as well as the causes and the potential consequences of the events presented. Two of the incidents examined, one from a DOE operation and the other from a U.S. Army facility, resulted in workers receiving chemical burns. The remaining two incidents are similar in that significant conduct of operations failures occurred resulting in high-level radioactive waste (in the case of the DOE facility) or chemical agent (in the case of the Army facility) being transferred outside of engineering controls. A review of the investigation reports for all four events indicates the primary causes to be failures in work planning leading to ineffective hazard evaluation and control, lack of procedure adherence, and most importantly, lack of management oversight to effectively reinforce expectations for safe work planning and execution. DOE and Army safety programs are similar, and although there are some differences in contractual requirements, the expectations for safe performance are essentially the same. This analysis concludes that instilling a positive safety culture comes down to management leadership and engagement to (1) cultivate an environment that values a questioning attitude and (2) continually reinforce expectations for the appropriate level of rigor in work planning and procedure adherence. A review of the root causes and key contributing causes to the events indicate: - Three of the four root cause analyses cite lack of management engagement (oversight, involvement, ability to recognize issues, etc.) as a root cause to the events. - Two of the four root cause analyses cite work planning failures as a root cause to the events and all cause analyses reflect work planning failures as contributing factors to the events. - All events with the exception of the Tuba City plant shutdown indicate procedure noncompliance as a key contributor; in the case of Tuba City the procedure issues were primarily related to a lack of procedures, or a lack of sufficiently detailed procedures. - All events included discussion or suggestion of a lack of a questioning attitude, either on the part of management/supervision, work planners, or workers. This analysis suggests that the most critical drivers to safety culture are: - Management engagement, - Effective work planning and procedures, and - Procedure adherence with a questioning attitude to ensure procedural problems are identified and fixed. In high-hazard operational environments the importance of robust work planning processes and procedure adherence cannot be overstated. However, having the processes by themselves is not enough. Management must actively engage in expectation setting and ensure work planning that meets expectations for hazard analysis and control, develop a culture that encourages incident reporting and a questioning attitude, and routinely observe work performance to reinforce expectations for adherence to procedures/work control documents. In conclusion, the most critical driver to achieving a workforce culture that supports safe and effective project performance can be summarized as follows: 'Management engagement to continually reinforce expectations for work planning processes and procedure adherence in an environment that cultivates a questioning attitude'. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stable boundary layer wind shear model for aircraft flight hazard definition

It is pointed out that wind shear, particularly at the lower altitudes in the terminal area, has been identified as being hazardous to aircraft operations. Accurate and reliable wind profiles are required for use in fast time and manned flight simulation studies aimed at fully defining and understanding the wind shear hazard. A description is presented of wind speed profiles for neutral and stable atmospheric conditions developed for the simulation studies to improve the safety and reliability of operations in the terminal area. The wind shear is mathematically modeled and the mathematical scenarios are presented in a format for direct application to wind shear hazard/flight simulation studies.

Frost, W.↗

Development Testing of the Gateway Integrated Bipropellant Refueling Subsystem

The Lunar Gateway is a deep space orbiting outpost being developed by the National Aeronautics and Space Administration (NASA) in partnership with the European Space Agency (ESA) and other domestic and international partners. Because Gateway is a vital component of NASA’s Artemis program supporting long-term human exploration of the moon, it is designed for on-orbit refueling to allow for a longer life performance. The reaction control system (RCS) bipropellant refueling system onboard the station will have the capability to transfer propellants, monomethyl hydrazine (MMH) and mixed oxides of nitrogen-3 (MON-3), under controlled conditions and will span across three modules: the European System Providing Refueling Infrastructure and Telecommunication Refueling Module (ESPRIT-RM or ERM), the Habitation and Logistics Outpost (HALO), and the Propulsion and Power Element (PPE). These propellant transfers are complex operations with known hazards, and one of the risk areas is exceeding the flight system’s maximum design pressure (MDP) in priming and refueling pause/stop operations. In priming, liquid propellant is transferred from a pressurized source tank to evacuated transfer lines, which could result in excessive transient surge pressures and potentially damage hardware. In refueling pause/stop operations, fast-acting isolation valves (IV) are closed, which could lead to damaging water hammer. To mitigate these risks and develop the system, a collaborative NASA/ESA/Thales Alenia Space – United Kingdom (TAS-UK) test program was completed at TAS-UK on a simplified refueling breadboard representing ERM, HALO, and PPE bipropellant transfer systems. The objectives of the integrated breadboard testing were to (1) gather performance data to characterize and demonstrate critical refueling operations, (2) help inform flight designs, and (3) to validate numerical models that can be extended to predicting flight system performance. Integrated breadboard test data has shown the architected system performance is closing initial design assumptions. Further testing with propellant on a higher fidelity fluid simulator and analysis are planned.

Adela D Han↗

Development Testing of the Gateway Integrated Bipropellant Refueling Subsystem

The Lunar Gateway is a deep space orbiting outpost being developed by the National Aeronautics and Space Administration (NASA) in partnership with the European Space Agency (ESA) and other domestic and international partners. Because Gateway is a vital component of NASA’s Artemis program supporting long-term human exploration of the moon, it is designed for on-orbit refueling to allow for a longer life performance. The reaction control system (RCS) bipropellant refueling system onboard the station will have the capability to transfer propellants, monomethyl hydrazine (MMH) and mixed oxides of nitrogen-3 (MON-3), under controlled conditions and will span across three modules: the European System Providing Refueling Infrastructure and Telecommunication Refueling Module (ESPRIT-RM or ERM), the Habitation and Logistics Outpost (HALO), and the Propulsion and Power Element (PPE). These propellant transfers are complex operations with known hazards, and one of the risk areas is exceeding the flight system’s maximum design pressure (MDP) in priming and refueling pause/stop operations. In priming, liquid propellant is transferred from a pressurized source tank to evacuated transfer lines, which could result in excessive transient surge pressures and potentially damage hardware. In refueling pause/stop operations, fast-acting isolation valves (IV) are closed, which could lead to damaging water hammer. To mitigate these risks and develop the system, a collaborative NASA/ESA/Thales Alenia Space – United Kingdom (TAS-UK) test program was completed at TAS-UK on a simplified refueling breadboard representing ERM, HALO, and PPE bipropellant transfer systems. The objectives of the integrated breadboard testing were to (1) gather performance data to characterize and demonstrate critical refueling operations, (2) help inform flight designs, and (3) to validate numerical models that can be extended to predicting flight system performance. Integrated breadboard test data has shown the architected system performance is closing initial design assumptions. Further testing with propellant on a higher fidelity fluid simulator and analysis are planned.

Adela D Han↗

In-Time Safety Assessment & Risk Prediction for Unmanned Aerial Systems

One of the critical challenges in emerging autonomous systems is timely mitigation of hazards encountered during operation which may not be known or accounted for at the time of design. Efficient execution of unmanned systems therefore demands a paradigm shift from scheduled periodic maintenance to predictive risk analysis that includes condition-based-monitoring, real-time reliability assessment and hazard mitigation. Particularly, the state-of-health parameters needs to be computed at the component level, unit level as well as the integrated system level. While in the former two levels, the physics of health propagation may be based on underlying electro-mechanical properties, system level prognostics often relies on data-driven models. Further, uncertainty from model, measurements and input sources should be accurately quantified to generate meaningful prediction results that can be fed into reliable decision making processes. Finally, the expected risk and time to failure has to be computed based on the current state-of-health of the overall system. This talk presents a conceptual design of such an in-time safety assurance approach for unmanned aerial vehicles (UAV) operating at low altitudes near and over populated areas. Typical in-flight hazard incidents include unplanned detour, proximity to obstacles, mid-flight component faults, limited battery life and poor quality of GPS measurements. Safety assessment therefore comprises trajectory generation and re-plan, battery RUL computation, distributed fault diagnostics and uncertainty management of predicted trajectory based on GPS measurement noise. The entire monitoring framework will be demonstrated on simulated as well as real UAV flight experiments conducted at the NASA Langley Research Center. This tutorial will therefore guide the audience through a step-by-step tracking of an autonomous system with focus on in-time risk prediction in the presence of unforeseen hazards and uncertain environment.

diagnostics↗

Waste Encapsulation and Storage Facility Stabilization and Ventilation Project-18121

Department of Energy contractor CH2M HILL Plateau Remediation Company (CH2M) is responsible for the safe and compliant operation of the Waste Encapsulation and Storage Facility (WESF), a nuclear materials storage facility at Hanford containing 1,936 highly radioactive capsules containing cesium and strontium. The capsules are currently stored under approximately 4 m (13 ft) of water. The water shields workers from radiation and helps cool the capsules. WESF is a large, concrete structure nominally 48 m (160 ft) long, 30 m (98 ft) wide and 12 m (40 ft) high with the pool cells being approximately 4 m (13 ft) below grade level. It is a robust facility with walls ranging from 0.3 m to 1 m (1 ft to 3 ft) thick. While the capsules are currently in a safe configuration, WESF is an aging facility, and DOE and CH2M are modifying the facility to ensure continued safe and compliant operations and to support the eventual transfer of capsules to dry storage. Dry storage would eliminate the possibility of a release of radioactive material in the unlikely event of a major earthquake that might result in loss of pool storage water and overheating and breach of one or more capsules. The project was divided into two major deliverables: 1) Ventilation: replacement of the existing ventilation system which included a below-grade high efficiency particulate air (HEPA) filter pit with an above grade HEPA filter skid and new fans and ducting. 2) Stabilization: grouting deactivated facility hot cells and other void spaces to the maximum extent practical to reduce material at risk from legacy contamination. The aging ventilation system relied on HEPA filters that exceeded their operational life. Due to the high levels of radionuclide contamination, replacing the filters was impractical and highly hazardous. CH2M installed a new ventilation system to provide safe and compliant ventilation for future operations. The project used an existing, unused ventilation skid that was designed for another project. Repurposing the unused skid presented additional technical challenges to modify the system for the project specific requirements. The new system is above ground, easier to maintain and is built to current standards. New connections inside the facility were installed to allow the new ventilation to operate effectively. The stabilization project is unique in that core drilling and grouting was performed in an operating Hazard Category 2 nuclear facility, which brought forth safety basis and environmental regulatory challenges. The hot cells were isolated from all existing support utilities including electrical, process chemicals, manipulator ports, instrument air, etc. to seal the hot cells and prevent highly contaminated supernate or grout from leaking into adjacent galleries. A high flow grout was used to maximize the distance between injection ports. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hazardous Waste Management Progress Report [SB14]

The Department of Energy (DOE) is the owner and part operator of multiple facilities in Northern California. The facilities include those located at Lawrence Livermore National Laboratory (LLNL), Lawrence Berkeley National Laboratory (LBNL), Sandia National Laboratories/California (SNL/CA) and SLAC National Accelerator Laboratory (SLAC) among other sites. Through their operations, the facilities generate hazardous waste and, thereby, are subject to the requirements of Chapter 31 of the Title 22 California Code of Regulations, Waste Minimization. The Northern California sites are primarily research and development facilities in the areas relating to national security, high-energy physics, engineering, bioscience and environmental health and safety disciplines. As mentioned above these DOE facilities are primarily research and development facilities. The hazardous wastes generated may be associated with operations that range in size from small, bench scale R&D to major maintenance and operations waste streams. Therefore, even though this document breaks down the waste streams based on California Waste Codes (CWC), the quantities of waste within one waste code category could be from many different locations and dissimilar processes. Because of the nature of the work at the sites, it is not economically feasible to try to implement source reduction measures for every process that generates a portion of the waste stream. This document identifies the processes that generate the major portion of the waste within an identified major waste stream and reports on progress made toward source reduction. In accomplishing the mission, it is DOE’s goal to eliminate waste generation and emissions giving priority to those that may present the greatest risk to human health and the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System architecture for the telerobotic work system

The functional and performance requirements and design concepts for a telerobotic work system (TWS) being considered as an adjunct to the Shuttle Remote Manipulator System and other applications are described. The multiple-armed free-flyer would be controlled by an operator in the Orbiter cabin and would perform remote sensing and manipulative tasks that EVA crew otherwise carry out. The TWS could also perform hazardous tasks, construction operations, and be an asset to the Space Station. Alternative system architectures are described, including the man-machine interface, the types of manipulators and their stowage, and the controls and backup systems. Potential terrestrial applications of the TWS concept, augmented with AI capabilities, are discussed.

Jenkins, Lyle M.↗

Step 1: Human System Integration Pilot-Technology Interface Requirements for Weather Management

This document involves definition of technology interface requirements for Hazardous Weather Avoidance. Technology concepts in use by the Access 5 Weather Management Work Package were considered. Beginning with the Human System Integration (HIS) high-level functional requirement for Hazardous Weather Avoidance, and Hazardous Weather Avoidance technology elements, HSI requirements for the interface to the pilot were identified. Results of the analysis describe (1) the information required by the pilot to have knowledge of hazardous weather, and (2) the control capability needed by the pilot to obtain hazardous weather information. Fundamentally, these requirements provide the candidate Hazardous Weather Avoidance technology concepts with the necessary human-related elements to make them compatible with human capabilities and limitations. The results of the analysis describe how Hazardous Weather Avoidance operations and functions should interface with the pilot to provide the necessary Weather Management functionality to the UA-pilot system. Requirements and guidelines for Hazardous Weather Avoidance are partitioned into four categories: (1) Planning En Route (2) Encountering Hazardous Weather En Route, (3) Planning to Destination, and (4) Diversion Planning Alternate Airport. Each requirement is stated and is supported with a rationale and associated reference(s).

Source record↗

The dual axis radiographic hydrodynamic test (DARHT) facility personnel safety system (PSS) control system

The mission of the Dual Axis Radiograph Hydrodynamic Test (DARHT) Facility is to conduct experiments on dynamic events of extremely dense materials. The PSS control system is designed specifically to prevent personnel from becoming exposed to radiation and explosive hazards during machine operations and/or the firing site operation. This paper will outline the Radiation Safety System (RSS) and the High Explosive Safety System (HESS) which are computer-controlled sets of positive interlocks, warning devices, and other exclusion mechanisms that together form the PSS.

43/57↗

CMMAD Usability Case Study in Support of Countermine and Hazard Sensing

During field trials, operator usability data were collected in support of lane clearing missions and hazard sensing for two robot platforms with Robot Intelligence Kernel (RIK) software and sensor scanning payloads onboard. The tests featured autonomous and shared robot autonomy levels where tasking of the robot used a graphical interface featuring mine location and sensor readings. The goal of this work was to provide insights that could be used to further technology development. The efficacy of countermine systems in terms of mobility, search, path planning, detection, and localization were assessed. Findings from objective and subjective operator interaction measures are reviewed along with commentary from soldiers having taken part in the study who strongly endorse the system.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗