Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Prototype high speed optical delay line for stellar interferometry

The long baselines of the next-generation ground-based optical stellar interferometers require optical delay lines which can maintain nm-level path-length accuracy while moving at high speeds. NASA-JPL is currently designing delay lines to meet these requirements. The design is an enhanced version of the Mark III delay line, with the following key features: hardened, large diameter wheels, rather than recirculating ball bearings, to reduce mechanical noise; a friction-drive cart which bears the cable-dragging forces, and drives the optics cart through a force connection only; a balanced PZT assembly to enable high-bandwidth path-length control; and a precision aligned flexural suspension for the optics assembly to minimize bearing noise feedthrough. The delay line is fully programmable in position and velocity, and the system is controlled with four cascaded software feedback loops. Preliminary performance is a jitter in any 5 ms window of less than 10 nm rms for delay rates of up to 28 mm/s; total jitter is less than 10 nm rms for delay rates up to 20 mm/s.

Colavita, M. M.↗

Two-dimensional spectral shearing interferometry resolved in time for ultrashort optical pulse characterization

We present a new scheme for coherent measurement of ultrashort optical pulses that relies on spectral shearing interferometry combined with all-optical time gating. The spectral phase is encoded along a temporal coordinate resulting in a two-dimensional (2D) self-referenced and self-calibrating set of data. The method works without time delay between the two interfering signals. The pulse amplitude and phase are reconstructed with a high signal-to-noise ratio using a direct algorithm that applies a Fourier transform (FT) to the 2D recorded interference pattern. Characterization of low-energy, high-repetition-rate femtosecond pulses of various shapes and validation of a single-shot operation are reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical nanofiber testbeds for benchmarking membrane-waveguide photonic integrated circuit platforms toward on-chip quantum inertial sensing

Recent advances in cold atom interferometry with optical and magnetic atom guides have set the stage for quantum inertial sensors capable of operating in dynamic environments. In this work, we present three key innovations—evanescent-field (EF) atom guides, optical nanofiber testbeds, and membrane-waveguide photonic integrated circuit (PIC) platforms—to advance EF-guided atom interferometry. First, we demonstrate EF atom guides on optical nanofiber testbeds, which serve as performance benchmarks for our membrane-waveguide PIC platforms. Second, we achieve low-power (⁠ ~ 5 mW) guiding of freely moving, laser-cooled 133 Cs atoms in two-color, traveling-wave EF optical dipole traps at the novel, heat-efficient magic wavelengths of 793 and 937 nm (i.e., “793/937-nm EF atom guides”). Concurrently, we design and fabricate membrane-waveguide PIC platforms for these EF atom guides; in our prior work, we showed that these structures safely accommodate 4–6 times the required optical trap power under vacuum and enable dense cold atom generation via magneto-optical trapping in the vicinity of the optical wavguide for efficient loading. Third, we verify preserved atomic coherence via microwave fields and EF-coupled Doppler-free Raman beams; to our knowledge, this is the first report of coherence fringes driven by co-propagating EF-coupled Raman beams with only 150 nW of total optical power. By providing a direct comparison between optical nanofiber testbeds and membrane-waveguide PIC platforms, our results lay critical groundwork for the on-chip realization of EF-guided atom interferometry and the development of fully integrated, compact, lightweight, and low-power quantum accelerometers and gyroscopes.

Orozco, Adrian [Sandia National Laboratories (SNL-↗

Microwave–photonic low-coherence interferometry for dark zone free distributed optical fiber sensing

A microwave–photonic low-coherence interferometry (MPLCI) system is proposed for fully distributed optical fiber sensing. Assisted by an unbalanced Michelson interferometer, a low-coherence laser source is used to interrogate cascaded Fabry–Perot interferometers along with an optical fiber for a dark zone free (or spatially continuous) distributed measurement. Here, by combining the advantages of microwaves and photonics, the MPLCI system can synergistically achieve high sensitivity and high spatial resolution. Our tests have confirmed a strain resolution of 95 nε at the spatial resolution of 10 cm.

42 ENGINEERING↗

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗

Thermal characterization of optical fibers using wavelength-sweeping interferometry

In this paper, we report a new method of thermal characterization of optical fibers using wavelength-sweeping interferometry and discuss its advantages compared to other techniques. The setup consists of two temperature-stabilized interferometers, a reference Michelson and a Mach-Zehnder, containing the fiber under test. The wavelength sweep is produced by an infrared tunable laser diode. We obtained the global phase shift coefficients of a large effective area fiber and gold-coated fiber optics with a 10{sup -7} accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical-precision alignment of diffraction grating mold in moire interferometry

A high-precision optical method is presented for aligning diffraction grating molds with the edges of specimens in moire interferometry. The alignment fixture is simple and convenient to operate. The conventional method of grating-mold alignment has a wide band of uncertainty in the range of error which is not compatible with the required precision of high-sensitivity moire interferometry. Following a description of the alignment technique, both the single-edge and parallel-edge guide bar optical alignment methods are introduced and compared.

Joh, D.↗

Multi-component measurements of the Jefferson Lab energy recovery linac electron beam using optical transition and diffraction radiation

DOI: http://dx.doi.org/10.1103/PhysRevSTAB.11.082801 High brightness electron accelerators, such as energy recovery linacs (ERL), often have complex particle distributions that can create difficulties in beam transport as well as matching to devices such as wigglers used to generate radiation from the beam. Optical transition radiation (OTR), OTR interferometry (OTRI) and optical diffraction-transition radiation interferometry (ODTRI) have proven to be effective tools for diagnosing both the spatial and angular distributions of charged particle beams. OTRI and ODTRI have been used to measure rms divergences and optical transverse phase space mapping has been demonstrated using OTRI. In this work we present the results of diagnostic experiments using OTR and ODR conducted at the Jefferson Laboratory 115 MeV ERL which show the presence of two separate components within the spatial and angular distributions of the beam. By assuming a correlation between the spatial and angular fe

43 PARTICLE ACCELERATORS↗

Invited Review Article: Measurement uncertainty of linear phase-stepping algorithms

Phase retrieval techniques are widely used in optics, imaging and electronics. Originating in signal theory, they were introduced to interferometry around 1970. Over the years, many robust phase-stepping techniques have been developed that minimize specific experimental influence quantities such as phase step errors or higher harmonic components of the signal. However, optimizing a technique for a specific influence quantity can compromise its performance with regard to others. We present a consistent quantitative analysis of phase measurement uncertainty for the generalized linear phase stepping algorithm with nominally equal phase stepping angles thereby reviewing and generalizing several results that have been reported in literature. All influence quantities are treated on equal footing, and correlations between them are described in a consistent way. For the special case of classical N-bucket algorithms, we present analytical formulae that describe the combined variance as a function of the phase angle values. For the general Arctan algorithms, we derive expressions for the measurement uncertainty averaged over the full 2{pi}-range of phase angles. We also give an upper bound for the measurement uncertainty which can be expressed as being proportional to an algorithm specific factor. Tabular compilations help the reader to quickly assess the uncertainties that are involved with his or her technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Report for the Pathfinder Project: A Laser-Based / Fiber Optic IAEA Seal That Implements Spectral Interferometry

This is the first progress report for the Laser / Fiber-Optic Based IAEA Seal. This seal implements spectral interferometry, which is crucial for its resilience to tampering. Indeed, based on our understanding of telecommunications-based fiber optic technology, it is essentially impossible to tamper with the fiber without detection either immediately (with an active system) or subsequently (with a passive system).

36 MATERIALS SCIENCE↗

Fiber-optic projected-fringe digital interferometry

A phase-stepped projected-fringe interferometer was developed which uses a closed-loop fiber-optic phase-control system to make very accurate surface profile measurements. The closed-loop phase-control system greatly reduces phase-stepping error, which is frequently the dominant source of error in digital interferometers. Two beams emitted from a fiber-optic coupler are combined to form an interference fringe pattern on a diffusely reflecting object. Reflections off of the fibers' output faces are used to create a phase-indicating signal for the closed-loop optical phase controller. The controller steps the phase difference between the two beams by pi/2 radians in order to determine the object's surface profile using a solid-state camera and a computer. The system combines the ease of alignment and automated data reduction of phase-stepping projected-fringe interferometry with the greatly improved phase-stepping accuracy of our closed-loop phase-controller. The system is demonstrated by measuring the profile of a plate containing several convex surfaces whose heights range from 15 to 25 micron high.

Mercer, Carolyn R.↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technology development for the Space Interferometry Mission (SIM) - status and plans

Optical and infrared interferometry will open new vistas for astronomy over the next decade. The Interferometry Technology Program at NASA's Jet Propulsion Laboratory is addressing these challenges with a development program that plans to establish technology readiness for the Space Interferometry Mission by end of 2001.

interferometry metrology↗

Fast electron transport and induced heating in solid targets from rear-side interferometry imaging

Fast adiabatic plasma heating of a thin solid target irradiated by a high intensity laser has been observed by an optical fast interferometry diagnostic. It is driven by the hot electron current induced by the laser plasma interaction at the front side of the target. Radial and longitudinal temperature profiles are calculated to reproduce the observed rear-side plasma expansion. The main parameters of the suprathermal electrons (number, temperature, and divergence) have been deduced from these observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A desktop interferometer for optical synthesis imaging

A simple desktop optical interferometer is described and demonstrated as a teaching tool for concepts of long-baseline stellar interferometry. The invariance of closure phase is introduced and illustrated. The differences between image synthesis with this interferometer and astronomical interferometers are shown and discussed.

interferometry↗

Measurement of longitudinal displacement using lateral shearing cyclic path optical configuration setup and phase shifting interferometry

We present a technique for the measurement of longitudinal displacement using a lateral shearing cyclic path optical configuration (CPOC) setup and phase shifting interferometry. In the technique, a plane mirror mounted on a linear translation stage, placed slightly away from the focal plane of a lens, introduces a longitudinal focal shift to the incident focusing beam. The resulting spherical wavefront emerging from the lens is sheared into two orthogonally polarized beams using the CPOC setup. By applying polarization phase shifting interferometry (PPSI), the longitudinal focal shift of the beam focus is calculated by determining the slope of the optical path difference variation between the sheared beams. Similarly, the additional focal shift introduced due to longitudinal translation of the mirror, by an unknown amount, is determined using PPSI. Half of the difference between the two longitudinal focal shifts measured gives the longitudinal displacement of the mirror. The technique can be used for an extended range of distance measurement. The novelty of the technique is the introduction of CPOC for the distance measurement. The advantages of the technique compared to other related methods are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗