Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimized electrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Status of nickel-hydrogen cell technology

Nickel hydrogen cell technology has been developed which solves the problems of thermal management, oxygen management, electrolyte management, and electrical and mechanical design peculiar to this new type of battery. This technology was weight optimized for low orbit operation using computer modeling programs but is near optimum for other orbits. Cells ranging in capacity up to about 70 ampere-hours can be made from components of a single standard size and are available from two manufacturers. The knowledge gained is now being applied to the development of two extensions to the basic design: a second set of larger standard components that will cover the capacity range up to 150 ampere-hours; and the development of multicell common pressure vessel modules to reduce volume, cost and weight. A manufacturing technology program is planned to optimize the producibility of the cell design and reduce cost. The most important areas for further improvement are life and reliability which are governed by electrode and separator technology.

Warnock, D. R.↗

Analysis of Fluid Gauge Sensor for Zero or Microgravity Conditions using Finite Element Method

In this paper the Finite Element Method (FEM) is presented for mass/volume gauging of a fluid in a tank subjected to zero or microgravity conditions. In this approach first mutual capacitances between electrodes embedded inside the tank are measured. Assuming the medium properties the mutual capacitances are also estimated using FEM approach. Using proper non-linear optimization the assumed properties are updated by minimizing the mean square error between estimated and measured capacitances values. Numerical results are presented to validate the present approach.

Deshpande, Manohar D.↗

Optimized Li-Ion Electrolytes Containing Fluorinated Ester Co-Solvents

A number of experimental lithium-ion cells, consisting of MCMB (meso-carbon microbeads) carbon anodes and LiNi(0.8)Co(0.2)O2 cathodes, have been fabricated with increased safety and expanded capability. These cells serve to verify and demonstrate the reversibility, low-temperature performance, and electrochemical aspects of each electrode as determined from a number of electrochemical characterization techniques. A number of Li-ion electrolytes possessing fluorinated ester co-solvents, namely trifluoroethyl butyrate (TFEB) and trifluoroethyl propionate (TFEP), were demonstrated to deliver good performance over a wide temperature range in experimental lithium-ion cells. The general approach taken in the development of these electrolyte formulations is to optimize the type and composition of the co-solvents in ternary and quaternary solutions, focusing upon adequate stability [i.e., EC (ethylene carbonate) content needed for anode passivation, and EMC (ethyl methyl carbonate) content needed for lowering the viscosity and widening the temperature range, while still providing good stability], enhancing the inherent safety characteristics (incorporation of fluorinated esters), and widening the temperature range of operation (the use of both fluorinated and non-fluorinated esters). Further - more, the use of electrolyte additives, such as VC (vinylene carbonate) [solid electrolyte interface (SEI) promoter] and DMAc (thermal stabilizing additive), provide enhanced high-temperature life characteristics. Multi-component electrolyte formulations enhance performance over a temperature range of -60 to +60 C. With the need for more safety with the use of these batteries, flammability was a consideration. One of the solvents investigated, TFEB, had the best performance with improved low-temperature capability and high-temperature resilience. This work optimized the use of TFEB as a co-solvent by developing the multi-component electrolytes, which also contain non-halogenated esters, film forming additives, thermal stabilizing additives, and flame retardant additives. Further optimization of these electrolyte formulations is anticipated to yield improved performance. It is also anticipated that much improved performance will be demonstrated once these electrolyte solutions are incorporated into hermetically sealed, large capacity prototype cells, especially if effort is devoted to ensure that all electrolyte components are highly pure.

Prakash, G. K. Surya↗

Advancing the Performance of Anion Exchange Membrane Electrolysis by Employing a Powder-Based Ionomer during Anode Catalyst Layer Fabrication

The performance of anion exchange membrane water electrolysis (AEMWE) can be significantly improved by utilizing powdered ionomers during the fabrication of the anode catalyst layer (CL) to modify the CL properties. When comparing powdered ionomers to dispersed ionomers across various catalysts including cobalt oxide (Co 3 O 4 ), nickel−iron oxide (NiFe 2 O 4 ), and iridium oxide (IrO 2 ) the anode fabricated with powdered ionomers demonstrates improved performance in polarization curves, enhanced charge transfer kinetics, and reduced ohmic and transport losses, as evidenced by voltage breakdown and electrochemical impedance spectroscopy analyses. Optimal performance is achieved using a Co 3 O 4 catalyst with a 10 wt % powdered ionomer via the catalystcoated substrate method. Microscopy analyses reveal that electrodes formed with powdered ionomers during fabrication exhibit a more uniform catalyst and ionomer distribution, increased porosity with smaller pore areas, improved electronic conduction with less catalyst agglomeration isolated by a nonconductive ionomer, and enhanced interfacial contact with the membrane and transport layer. These findings highlight that ionomers in a powdered form can promote beneficial properties and are a promising approach to improving AEMWE efficiency.

08 HYDROGEN↗

Effect of thrust chamber configuration on MPD arcjet performance

The performance of quasisteady multimegawatt MPD thrusters is significantly affected by anode thickness, location, and orifice radius, and by cathode length. Terminal voltage oscillations and electrode erosion are deferred until higher currents by anodes at more downstream locations and of smaller orifice radius and by cathodes of greater length. Without an optimized geometry, specific impulses of 3300 s and thrust efficiencies up to 31% are implied by the best data.

King, D. Q.↗

Mercury ion thruster technology

The Mercury Ion Thruster Technology program was an investigation for improving the understanding of state-of-the-art mercury ion thrusters. Emphasis was placed on optimizing the performance and simplifying the design of the 30 cm diameter ring-cusp discharge chamber. Thruster performance was improved considerably; the baseline beam-ion production cost of the optimized configuration was reduced to Epsilon (sub i) perspective to 130 eV/ion. At a discharge propellant-utilization efficiency of 95 percent, the beam-ion production cost was reduced to about 155 eV/ion, representing a reduction of about 40 eV/ion over the corresponding value for the 30 cm diameter J-series thruster. Comprehensive Langmuir-probe surveys were obtained and compared with similar measurements for a J-series thruster. A successful volume-averaging scheme was developed to correlate thruster performance with the dominant plasma processes that prevail in the two thruster designs. The average Maxwellian electron temperature in the optimized ring-cusp design is as much as 1 eV higher than it is in the J-series thruster. Advances in ion-extraction electrode fabrication technology were made by improving materials selection criteria, hydroforming and stress-relieving tooling, and fabrications procedures. An ion-extraction performance study was conducted to assess the effect of screen aperture size on ion-optics performance and to verify the effectiveness of a beam-vectoring model for three-grid ion optics. An assessment of the technology readiness of the J-series thruster was completed, and operation of an 8 cm IAPS thruster using a simplified power processor was demonstrated.

Beattie, J. R.↗

An analysis of the frequency limitations of an Al(x)Ga(1-x)As/GaAs optical modulator

An analysis is made of the frequency response of an Al(x)Ga(1-x)As/GaAs optical modulator operating at a wavelength of 0.83 micron and utilizing the linear-optic effect in a Mach-Zehnder configuration. It is shown that, in semiconductor modulators, electroabsorption should be taken into account in optimizing the frequency response of the device. It is also shown that, by incorporating an insulator (a semiconductor with a large band gap) between the metallic electrode and the channel, the capacitance of the electroabsorptive modulator can be kept low at a reasonable value under the worst conditions.

Tabib-Azar, M.↗

Flexible Microsensor Array for the Monitoring and Control of Plant Growth System

Testing for plant experiments in space has begun to explore active nutrient delivery concepts in which water and nutrients are replenished on a continuous basis for long-term growth. The goal of this study is to develop a novel microsensor array to provide information on the dissolved oxygen environment in the plant root zone for the optimum control of hydroponics and solid substrate plant cultivation systems in the space environment. Miniaturized polarographic dissolved oxygen sensors have been designed and fabricated on a flexible Kapton (trademark) (polyimide) substrate. Two capabilities of the new microsensor array were explored. First, measurements of dissolved oxygen in the plant root zone in hydroponics and solid substrate culture systems were made. The microsensor array was fabricated on a flexible substrate, and then cut out into a mesh type to make a suspended array that could be placed either in a hydroponics system or in a solid substrate cultivation system to measure the oxygen environments. Second, the in situ self-diagnostic and self-calibration capability (two-point for oxygen) was adopted by dynamically controlling the microenvironment in close proximity to the microsensors. With a built-in generating electrode that surrounds the microsensor, two kinds of microenvironments (oxygen-saturated and oxygen-depleted phases) could be established by water electrolysis depending on the polarity of the generating electrode. The unique features of the new microsensor array (small size, multiple sensors, flexibility and self-diagnosis) can have exceptional benefits for the study and optimization of plant cultivation systems in both terrestrial and microgravity environments. The in situ self-diagnostic and self-calibration features of the microsensor array will also enable continuous verification of the operability during entire plant growth cycles. This concept of automated control of a novel chemical monitoring system will minimize crew time required for maintenance, as well as reduce volume, mass, and power consumption by eliminating bulky diagnosis systems including calibrant (fluid and gas) reservoir and flow system hardware.

Kim, Chang-Soo↗

Three-Dimensional Numerical Modeling of Magnetohydrodynamic Augmented Propulsion Experiment

Over the past several years, NASA Marshall Space Flight Center has engaged in the design and development of an experimental research facility to investigate the use of diagonalized crossed-field magnetohydrodynamic (MHD) accelerators as a possible thrust augmentation device for thermal propulsion systems. In support of this effort, a three-dimensional numerical MHD model has been developed for the purpose of analyzing and optimizing accelerator performance and to aid in understanding critical underlying physical processes and nonideal effects. This Technical Memorandum fully summarizes model development efforts and presents the results of pretest performance optimization analyses. These results indicate that the MHD accelerator should utilize a 45deg diagonalization angle with the applied current evenly distributed over the first five inlet electrode pairs. When powered at 100 A, this configuration is expected to yield a 50% global efficiency with an 80% increase in axial velocity and a 50% increase in centerline total pressure.

Turner, M. W.↗

Regulating in situ gaseous deposition to construct highly durable Fe–N–C oxygen-reduction fuel cell catalysts

The activity–stability trade-off challenges the design of high-performance atomically dispersed iron–nitrogen–carbon (Fe–N–C) catalysts for the acidic oxygen reduction reaction in polymer electrolyte fuel cells. Here we develop an in situ chemical vapour deposition approach during catalyst synthesis to break the trade-off, producing highly stable Fe–N–C catalysts while maintaining adequate oxygen reduction reaction activity. The optimal catalyst exhibits a half-wave potential of 0.867 V, remaining unchanged after an accelerated stress test (AST) of 100,000 potential cycles in rotating disk electrode tests. In membrane electrode assemblies under H 2 –air conditions, it delivers 93 mA cm −2 at 0.8 V after a standard AST of 30,000 voltage cycles, and shows minimal current density losses (2.9% at 0.6 V; 14.2% at 0.7 V) after an extended AST up to 120,000 cycles. Furthermore, the catalyst’s durability improvement is primarily due to the in situ chemical vapour deposition, which strengthens Fe–N bonds, increases active-site density, mitigates iron aggregates and reduces surface porosity.

Chemical engineering↗

Generating multi-scale Li-ion battery cathode particles with radial grain architectures using stereological generative adversarial networks

Abstract Understanding structure-property relationships of Li-ion battery cathodes is crucial for optimizing rate-performance and cycle-life resilience. However, correlating the morphology of cathode particles, such as in LiNi0.8Mn0.1Co0.1O2 (NMC811), and their inner grain architecture with electrode performance is challenging, particularly, due to the significant length-scale difference between grain and particle sizes. Experimentally, it is not feasible to image such a high number of particles with full granular detail. A second challenge is that sufficiently high-resolution 3D imaging techniques remain expensive and are sparsely available at research institutions. Here, we present a stereological generative adversarial network-based model fitting approach to tackle this, that generates representative 3D information from 2D data, enabling characterization of materials in 3D using cost-effective 2D data. Once calibrated, this multi-scale model can rapidly generate virtual cathode particles that are statistically similar to experimental data, and thus is suitable for virtual characterization and materials testing through numerical simulations. A large dataset of simulated particles with inner grain architecture has been made publicly available.

25 ENERGY STORAGE↗

Silver Electrolysis for Disinfection of Spacecraft Potable Water: 2023 Update

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. Last year’s paper reported a fault condition termed “electrode bridging,” in which silver deposits on interelectrode wetted materials, eventually bridging the electrode gap and providing an alternate conduction pathway that diminishes the silver output of the reactor. Since then, two strategies have been developed that prevent this fault from occurring: 1) increasing the frequency of polarity reversal and 2) separating the active surface of the electrode from the interelectrode wetted material. These strategies were tested independently, and in both cases, the reactor performed as expected with no occurrence of bridging for at least one crew-year equivalent of cumulative operation. Additional tests were conducted at varying levels of influent dissolved oxygen to better understand the nature of the cathode reaction and its impact on reactor performance. Results indicate that the primary cathode reaction is the reduction of dissolved oxygen, which could imply a dependence of reactor performance on dissolved oxygen concentration. However, it was found that at the typical oxygen concentrations anticipated for spacecraft processed water, the impact on silver electrolysis performance was negligible. Finally, multiphysics modelling of the reactor fluid mechanics and electrochemistry was undertaken to provide the capability to optimize the design of a future reactor prototype.

silver electrolysis↗

In-situ TEM EELS analysis of memristive thin films for neuromorphic computing

Neuromorphic computing stands as a promising frontier for advancing AI algorithms and applications like ChatGBT, offering significant energy efficiency gains. This paper delves into the hardware design intricacies of memristive thin films and their elementary switching mechanisms, including anion migration, electron migration, and phase transitions. Through comprehensive analysis of electron energy loss spectroscopy (EELS) data via in-situ transmission electron microscopy (TEM), we will deduce the primary memristive switching mechanisms vital for optimizing thin film fabrication parameters and achieving desired film thickness, conductivity, and memory retention. A single crystal ptype Si substrate was used with TiN as the bottom metal electrode, TiO x as the insulating dielectric layer, and Pt as the top metal electrode. In-situ TEM was able to tell us the thin film didn’t behave like a filamentary or phase transition material. EELS data deduced that electron trapping/detrapping was one of the primary switching mechanisms. By shedding light on these elementary mechanisms, our study aims to catalyze the development of more 2 efficient and effective neuromorphic computing systems to be deployed into mainstream technologies.

97 MATHEMATICS AND COMPUTING↗

Improving Sensorimotor Function Using Stochastic Vestibular Stimulation

Astronauts experience sensorimotor changes during spaceflight, particularly during G-transition phases. Post flight sensorimotor changes may include postural and gait instability, spatial disorientation, and visual performance decrements, all of which can degrade operational capabilities of the astronauts and endanger the crew. Crewmember safety would be improved if these detrimental effects of spaceflight could be mitigated by a sensorimotor countermeasure and even further if adaptation to baseline could be facilitated. The goal of this research is to investigate the potential use of stochastic vestibular stimulation (SVS) as a technology to improve sensorimotor function. We hypothesize that low levels of SVS will improve sensorimotor performance through stochastic resonance (SR). The SR phenomenon occurs when the response of a nonlinear system to a weak input signal is optimized by the application of a particular nonzero level of noise. Two studies have been initiated to investigate the beneficial effects and potential practical usage of SVS. In both studies, electrical vestibular stimulation is applied via electrodes on the mastoid processes using a constant current stimulator. The first study aims to determine the repeatability of the effect of vestibular stimulation on sensorimotor performance and perception in order to better understand the practical use of SVS. The beneficial effect of low levels of SVS on balance performance has been shown in the past. This research uses the same balance task repeated multiple times within a day and across days to study the repeatability of the stimulation effects. The balance test consists of 50 sec trials in which the subject stands with his or her feet together, arms crossed, and eyes closed on compliant foam. Varying levels of SVS, ranging from 0-700 micro A, are applied across different trials. The subject-specific optimal SVS level is that which results in the best balance performance as measured by inertial measurement units placed on the upper and lower torso of the subjects. Additionally, each individual’s threshold for illusory motion perception of suprasensory electrical vestibular stimulation is measured multiple times within and across days to better understand how multiple SVS test methods compare. The second study aims to demonstrate stochastic resonance in the vestibular system using a perception based motion recognition task. This task measures an individual’s velocity threshold of motion recognition using a 6-degree of freedom Stewart platform and a 3-down/1-up staircase procedure. For this study, thresholds are determined using 150 trials in the upright, head-centered roll tilt motion direction at a 0.2 Hz frequency. We aim to demonstrate the characteristic bell shaped curve associated with stochastic resonance with each subject’s motion recognition thresholds at varying SVS levels ranging from 0 to 1500 micro A. The curve includes the individual’s baseline threshold with no SVS, optimal or minimal threshold at some mid-level of SVS, and finally degraded or increased threshold at a high SVS level. An additional aim is to formally retest each subject at his or her individual optimal SVS level on a different day than the original testing for additional validity. The overall purpose of this research is to further quantify the effects of SVS on various sensorimotor tasks and investigate the practical implications of its use in the context of human space flight so that it may be implemented in the future as a component of a comprehensive countermeasure plan for adaptation to G-transitions.

Galvan, R. C.↗

Silver Electrolysis for Disinfection of Spacecraft Potable Water: 2023 Update

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. Last year’s paper reported a fault condition termed “electrode bridging,” in which silver deposits on interelectrode wetted materials, eventually bridging the electrode gap and providing an alternate conduction pathway that diminishes the silver output of the reactor. Since then, two strategies have been developed that prevent this fault from occurring: 1) increasing the frequency of polarity reversal and 2) separating the active surface of the electrode from the interelectrode wetted material. These strategies were tested independently, and in both cases, the reactor performed as expected with no occurrence of bridging for at least one crew-year equivalent of cumulative operation. Additional tests were conducted at varying levels of influent dissolved oxygen to better understand the nature of the cathode reaction and its impact on reactor performance. Results indicate that the primary cathode reaction is the reduction of dissolved oxygen, which could imply a dependence of reactor performance on dissolved oxygen concentration. However, it was found that at the typical oxygen concentrations anticipated for spacecraft processed water, the impact on silver electrolysis performance was negligible. Finally, multiphysics modelling of the reactor fluid mechanics and electrochemistry was undertaken to provide the capability to optimize the design of a future reactor prototype.

silver electrolysis↗

Impact of CuInP 2 S 6 –metal interfaces on the stabilization of polar phases and polarization switching

The multifunctionality of two-dimensional ferroelectric CuInP 2 S 6 (CIPS) arises from the existence of multiple polar phases combined with a high ionic conductivity that facilitates polarization switching in unusual ways. The van der Waals (vdW) layered structure provides ultrathin flakes and ideal interfaces to integrate with other materials for microelectronics and neuromorphic elements. However, device integration necessitates metal contacts to read, write, or transmit signals. In this work, we find that different types of metal–CIPS interfaces strongly impact the stabilization of specific polar phases and the field-induced transitions between the polarization states. Cu electrodes initially suppress the piezoresponse, whereas, at CIPS–Ag interfaces, the electromechanical signal is increased. Under electric fields, the Cu electrodes, Ag electrodes and surrounding CIPS surfaces can show distinct switching behavior as different phases and polarization orientations are stabilized. These findings highlight that metal–CIPS interfaces provide the opportunity to optimize functional material properties.

Ferroelectrics and multiferroics↗

Basic mechanisms study for MIS solar cell structures on GaAs

The solar cell structure examined is the MIS configuration on (n) GaAs. The metal room temperature oxide/(n) GaAs materials system was studied. Metals with electronegativities varying from 2.4 (Au) to 1.5 (Al) were used as the upper electrode. The thinnest metallization that did not interfere with the measurement techniques (by introducing essentially transmission line series resistance problems across a device) was used. Photovoltaic response was not optimized.

Fonash, S. J.↗

Development of Ultra Low Temperature, Impact Resistant Lithium Battery for the Mars Microprobe

The requirements of the power source for the Mars Microprobe, to be backpacked on the Mars 98 Spacecraft, are fairly demanding, with survivability to a shock of the order of 80,000 g combined with an operational requirement at -80 C. Development of a suitable power system, based on primary lithium-thionyl chloride is underway for the last eighteen months, together with Yardney Technical Products Inc., Pawcatuck, CT. The battery consists of 4 cells of 2 Ah capacity at 25 C, of which at least 25 % would be available at -80 C, at a moderate rate of C/20. Each probe contains two batteries and two such probes will be deployed. The selected cell is designed around an approximate 1/2 "D" cells, with flat plate electrodes. Significant improvements to the conventional Li-SOCl2 cell include: (a) use of tetrachlorogallate salt instead of aluminate for improved low temperature performance and reduced voltage delay, (b) optimization of the salt concentration, and (c) modification of the cell design to develop shock resistance to 80,000 g. We report here results from our several electrical performance tests, mission simulation tests, microcalorimetry and AC impedance studies, and Air gun tests. The cells have successfully gone through mission-enabling survivability and performance tests for the Mars Microprobe penetrator.

Frank, H.↗