Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARABOLIC FLIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The use of containerless processing in researching reactive materials

It has recently become possible to perform containerless, high-temperature liquid-phase processing of many nonvolatile materials without resort to orbital microgravity, thereby facilitating the conduct of materials research in conjunction with noncontact diagnostic instruments. The melt-levitation techniques are electromagnetic, aerodynamic, acoustic, aeroacoustic, and electrostatic; nonorbital microgravity conditions are obtainable aboard NASA's KC-135 aircraft on parabolic flight paths, as well as in drop tubes and towers. Applications encompass the purification of metals and the creation of nonequilibrium and metastable structures. Process control and property measurements include optical pyrometry and emissivity, laser polarimetry, and drop calorimetry.

Weber, J. K. R.↗

Process modeling KC-135 aircraft

Instrumentation will be provided for KC-135 aircraft which will provide a quantitative measure of g-level variation during parabolic flights and its effect on experiments which demonstrate differences in results obtained with differences in convective flow. The flight apparatus will provide video recording of the effects of the g-level variations on varying fluid samples. The apparatus will be constructed to be available to fly on the KC-135 during most missions.

Workman, Gary L.↗

Vibration isolation technology development to demonstration

The main thrust of these studies has resulted in an active inertial feedforward/feedback isolation system. This prototype magnetic suspension system has been demonstrated in a laboratory setting in six degrees-of-freedom and has been preliminarily characterized in its isolation performance with favorable results. This isolation system consists of a closed loop digital control system referencing a platform around six relative and six inertial sensors. These sensors control the isolated mass through nine attractive electromagnetic actuators with a system capability of +/- three-tenths of an inch travel in three dimensions. The development of a prototype system from design to fabrication leads directly into the demonstration phase of the project which will attempt a low gravity environmental demonstration of engineering hardware for the isolation of a scientific payload. The demonstration phase of the project will use an aircraft low gravity maneuver to establish a research testbed for the study of isolation hardware and control strategies in an off-loaded environment. In developing this demonstration capability the Lewis Learjet aircraft has been characterized through its parabolic flight maneuvers and a trunnioned experimental volume has been designed for the test of both active and passive isolation packages. This vibration isolation testbed is operational and has two data acquisition systems available for both autonomous and interactive operation, with a combined input capability of 32 channels.

Grodsinsky, Carlos↗

Convective flow analysis on the KC-135 aircraft

A study conducting bouyancy driven convective flow experiments on the NASA KC-135 aircraft is presented. The response of a contained fluid (with an imposed temperature gradient) to changing g-levels during parabolic flight was obtained. Models for both transient and steady state flows were developed utilizing PC-based CFD software. Comparisons between the theoretical models and the physical observations are quite good.

Workman, Gary L.↗

Control of robot dynamics using acceleration control

Acceleration control of robotic devices can provide improvements to many space-based operations using flexible manipulators and to ground-based operations requiring better precision and efficiency than current industrial robots can provide. This paper reports on a preliminary study of acceleration measurement on robotic motion during parabolic flights on the NASA KC-135 and a parallel study of accelerations with and without gravity arising from computer simulated motions using TREETOPS software.

Workman, G. L.↗

Tonic vibration reflexes and background force level

On earth, the functional stretch reflex is an important component in the maintenance of posture and muscle tone. In parabolic flight experiments, it is evaluated whether the functional stretch reflex, as reflected in the tonic vibration reflex, adjusts appropriately for changes in background gravitoinertial force level. Virtually immediate alterations of appropriate sign occurred.

Lackner, James R.↗

Effects of microgravity on the interaction of vestibular and optokinetic nystagmus in the vertical plane

The extent to which the slow phase velocity (SPV) of nystagmus elicited by a vertical optokinetic stimulation with constant velocity could be modulated by sinusoidal angular motion in the vertical plane was investigated under normal gravity condition and during the microgravity period of parabolic flight. In normal gravity, when the angular head motion and the optokinetic stimulation were in the same direction, the peak SPV was slower than the velocity of the optokinetic display. When the head motion and the optokinetic stimulation were in opposite directions, the peak SPV was equal to the velocity of the optokinetic display. In microgravity, the peak SPV was approximately equal to the velocity of the optokinetic display when head rotation and optokinetic stimulation were in the same direction, and was faster than the velocity of the optokinetic dispaly when head rotation and optokinetic stimulation were in opposite directions. In addition, the interaction of vestibular and optokinetic nystagmus was found to be nonlinear in microgravity, especially when the optokinetic stimulation was directed downward. These results suggest an interaction between the vestibular and the optokinetic systems modulated as a function of the gravitational state, and support the observation that visual input is more effective in reducing sensory conflict experienced in microgravity.

Clement, Gilles↗

A review of microgravity surgical investigations

The likelihood of performing a surgical procedure in space will increase as the Soviet Mir space station is expanded and the Space Station Freedom becomes operational. A review of previous research and hardware development, performed mostly in parabolic flight both in the Soviet Union and the U.S., reveals an interest in surgical chambers to prevent cabin atmosphere contamination. Surgical techniques appear to be no more difficult than in a 1-G environment if a restraint system is used. Minimizing the changes of wound infection from the high particle count spacecraft atmosphere is an additional concern. Additional research is necessary to delineate the clinical significance of these problems and to further develop surgical techniques in microgravity.

Campbell, Mark R.↗

Status of the CNRS-LCSR program on high pressure droplet vaporization and burning

Depending on the surrounding flow and thermodynamic conditions, a single droplet may experience several gasification regimes, ranging from the envelope flame regime to pure vaporization. In practical situations, such as rocket propulsion or diesel combustion, the size distribution of droplets is, at best, bimodal, so that the possibility exists for the simultaneous presence of various regimes. For example, very small droplets are transported by the gas phase with zero relative velocity. This picture validates then the spherical symmetry hypothesis applied to the droplet and to the diffusion flame enveloping it. On the other hand, for larger droplets, a relative velocity exists due to drag forces. The most important influence of forced convection on droplet burning is the possibility to extinguish globally the envelope flame, or to establish a flame stabilized in the wake region. The burning rates of these regimes differ strongly. The characteristic time of droplet gasification is also influenced by the surrounding pressure and temperature. A parametric investigation of single droplet burning regimes is then helpful in providing the necessary physical ideas for sub-grid models used in spray combustion numerical prediction codes. The CNRS-LCSR experimental program on droplet vaporization and burning deals with these various regimes: stagnant and convective monocomponent droplet burning convective mono and bicomponent droplet vaporization; high temperature convective mono and biocomponent droplet vaporization; burning regimes of hydrazine and hydroxyl-ammonium-nitrate based monopropellant droplets and the vaporization regimes of liquid oxygen droplets. Studies on interacting droplets and on liquid aluminum droplets will start in the near future. The influence of high pressure is a common feature of all these studies. This paper summarizes the status of the CNRS-LCSR program on the effects of high pressure on monocomponent single droplet burning and vaporization, and some recent results obtained under normal and reduced gravity conditions with suspended droplets are presented. In the work described here, parabolic flights of an aircraft is used to create a reduced gravity environment of the order of 10(exp -2) g.

Chauveau, Christian↗

Two techniques for measuring locomotion impact forces during zero G

A load-cell-instrumented treadmill mated to a Kistler force plate was used to investigate two methods of force measurement instrumentation during treadmill ambulation in zero g, created by parabolic flight on NASA's KC-135 aircraft. Current spaceflight treadmills do not have adequate instrumentation to determine the resultant foot impact force applied during restrained ambulation. Accurate measurement of foot-ground reaction forces is critical in attaining proper one-g loading, therefore ensuring proper musculoskeletal conditioning. Treadmill instrumentation and force plate measurements were compared for frequency response and linearity. Locomotion impact data were also collected under one-g laboratory settings and in Keplerian flight. The first resonant frequency for both techniques was found to be well above the primary frequency content of the locomotive forces. Peak impact forces measured by the two systems compared to within 10 percent.

Greenisen, Michael C.↗

Stardust: Studies in microgravity of condensation and agglomeration of cosmic dust analogue

A short description of the program Stardust whose goal is to study the formation and properties of high temperature particles and gases, including silicate and carbonaceous materials, that are of interest in astrophysics and planetary science, is given. The international program was carried out in microgravity conditions in parabolic flight. A description of the laboratory equipment, conceived to perform experimental tests in reduced gravity conditions, and which is based on the gas evaporation technique, is given. The gas evaporation technique utilizes one or more heated crucible to vaporize solids materials (SiO, Mg) in a low pressure of inert or reactive gas inside of a vacuum bell jar. The vapor pressures of the materials are controlled by the temperature of the crucibles. The temperature and pressure of inert gas are also controlled. By varying the vapor pressure relative to the gas temperature and pressure, the conditions for substantial grain condensation can be controlled and grain formation measured using light scattering techniques. Thus the partial pressure for grain condensation, can be measured as a function of temperature. The gas evaporation technique has the advantage that complex chemical systems can be studied by using multiple crucibles each containing solid source material. Experimental results and future trends are addressed.

Ferguson, F.↗

Torsional vestibulo-ocular reflex measurements for identifying otolith asymmetries possibly related to space motion sickness susceptibility

Recent studies have identified significant correlations between space motion sickness susceptibility and measures of disconjugate torsional eye movements recorded during parabolic flights. These results support an earlier proposal which hypothesized that an asymmetry of otolith function between the two ears is the cause of space motion sickness. It may be possible to devise experiments that can be performed in the 1 g environment on earth that could identify and quantify the presence of asymmetric otolith function. This paper summarizes the known physiological and anatomical properties of the otolith organs and the properties of the torsional vestibulo-ocular reflex which are relevant to the design of a stimulus to identify otolith asymmetries. A specific stimulus which takes advantage of these properties is proposed.

Peterka, Robert J.↗

Definition of two-phase flow behaviors for spacecraft design

Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. A boiling and condensing experiment was built in which R-12 was used as the working fluid. A two-phase pump was used to circulate a freon mixture and allow separate measurements of the vapor and liquid flow streams. The experimental package was flown five times aboard the NASA KC-135 aircraft which simulates zero-g conditions by its parabolic flight trajectory. Test conditions included stratified and annual flow regimes in 1-g which became bubbly, slug, or annular flow regimes on 0-g. A portion of this work is the analysis of adiabatic flow regimes. The superficial velocities of liquid and vapor have been obtained from the measured flow rates and are presented along with the observed flow regimes.

Reinarts, Thomas R.↗

Central circulatory hemodynamics as a function of gravitational stress

This study focuses on an evaluation of the central hemodynamics in a nonhuman primate model to variations in gravitational states. The baboon, phylogenectically close to man, was chosen as the human surrogate. The study environments selected are head-down and head-up tilt in the physiology laboratory, centrifugation to test hypergravic stress, and parabolic flights to test transient acute responses to microgravity.

Latham, Rick D.↗

Neurophysiological study on visuo-vestibular control of posture and movement in fish during adaptation to weightlessness

We can stand upright and walk smoothly without paying any particular attention to it. This is because we have established in ourselves an integration center that controls our body subconsciously in response to input from eyes, muscles, joints, foot soles, and also from the gravity sensor in the inner ear (the otolith organ). It has been shown that the cerebellum plays an important role for the establishment of the integration center and that the control pattern is comparable to that of a highly sophisticated computer system. The programming for the control, however, may well be acquired for the 1-g ground condition and does not cover the 0-g in space. Although each of the above organs function as it does on the ground, the signal pattern sent to the center must be different under 0-g and, in addition, complementary signals from the otolith organ are missing, leading to confusion in the integration center and causing a variety of symptoms similar to those of car-sickness or sea-sickness. After exposure to microgravity an immediate process of re-programming will begin and be completed in 2-4 days. There is strong supporting evidence for this sensory conflict theory as an explanation for space motion sickness (SMS) episodes. Fish were selected as test organisms for this investigation because they swim around freely in three dimensions and have well-developed organs for vision and gravity detection. They also have an innate nature to orient their back toward a light source. Actually, on the ground, the fish tilts its vertical axis toward the light when illuminated laterally, and the tilt angle is a function of the intensity of light and the magnitude of gravity, while its posture is completely light-dependent in the low-gravity environment produced by aircraft parabolic flight or when the otolith organs are removed. This implies that fish posture is entirely under visual and otolithic control. In this case, the cerebellum will also contribute to the control. In the space shuttle experiment, two fish (one with otolith-removed and the other with intact otoliths) are onboard for 7 days. The arrangement of the experiment is shown. Lamps illuminate each fish alternately from different directions at a duration of 20 seconds for 10 minutes totally, twice a day. The video images and the brain waves from the cerebellum are analyzed later. If the sensory conflict theory is acceptable, then the confusion at the onset and the following recovery process will be manifested both in the light-dependent behavior and also in the cerebellar activity. In addition, there should be some variation in response between the two fish. Even if the results are positive in the present fish experiment, they would not be extensive enough to allow us to understand the complete mechanisms of SMS. However, what is currently needed is a collection of evidence based on animal experiments on which to base future investigations. Countermeasures for SMS are mandatory since SMS-induced vomiting occurring within a space suit could be fatal for a crew member during extravehicular activities. We expect that countermeasures will be developed before the space station era starts, and that the results of these studies will be applied to improving human welfare.

Mori, Shigeo↗

Comparative measurement of visual stability in Earth and cosmic space (L-4)

The frequency and the intensity of space motion sickness was reviewed and investigated. Unusual induced-gravity situations, such as rotation, linear acceleration, parallel swinging etc. were investigated as well. Visually-induced motion sensation or distorted perception were evaluated with respect to visual stability by many investigators. These studies are all concerned with the effect of gravity and the induction of motion sickness through human visual perception. Direct investigation under the microgravity situation, such as parabolic flight, Skylab, and Spacelab, was carried out. These studies focused on how human visual stability is established through various sensory afferents in specific gravity conditions. Results from these investigations indicate that sensory mismatch probably plays an important role in space motion sickness. The interaction of visual, vestibular, and somatosensory perception is smoothly coordinated under normal gravitational conditions on the Earth in our daily life. When the cooperation is destroyed or a mismatch occurs among them, motion sickness may develop not only on the Earth but also in microgravity. The latter case may be the cause of space motion sickness or space adaption syndrome. How human beings obtain visual stability even with posture changes on the ground was investigated. Visual stability can be categorized as static or dynamic. Static visual stability is concerned with orientation and dynamic stability is concerned with object motion perception. The perception of visual stability is modified by many other sensations, such as somatosensory, vestibular, and muscle tension. We will mainly focus on modifications by vestibular inputs to visual perception produced by eye movements in microgravity. The Vestibular-Oscular Reflex (VOR) is a well-known characteristic which results from the relationship between eye mobility and vestibular afferent inputs. Eye movements also modify dynamic visual perception, such as perceived object motion velocity. The VOR is constantly simulated under 1-g conditions on Earth. In fact, human beings have been habituated and 'programmed' for orientation (visual stability) in their everyday, 1-g environment. When humans are exposed to a different gravity situation, this programmed behavior must change; that is, it is reprogrammed. This is called habituation or familiarization. We hope to examine how object motion perception is perturbed and subsequently adapted in the microgravity environment. This experiment is focused on the cooperation of visual, vestibular, and somatosensory perception coordination and how it is changed or reduced in space compared to 1-g environment. We will obtain information on the coordination between eye movement and neck muscle activity by using EOG and EMG. We will also collect data from Payload Specialists using a self-diagnostic questionnaire concerned with perceptual abnormality. When each sensory input function and its integration in the higher nervous system are well-characterized, then more effective techniques to control SAS may be developed.

Koga, Kazugo↗

Recovery of the vomiting reflex following area postrema ablation in squirrel monkeys

Current theory and recent evidence suggest that motion sickness occurs under conditions of sensory input in which the normal motor programs for producing eye, head, and body movements are not functionally effective, i.e. under conditions in which there are difficulties in maintaining posture and controlling eye movements. Conditions involving conflicting or inconsistent visual-vestibular (VV) simulation should thus result in greater sickness rates since the existing motor programs do not produce effective control of eye-head-body movements under such conditions. We feel that the relationship of postural control to motion sickness is an important one and one often overlooked. We reported the results of a study which showed that when postural requirements were minimized by fully restraining squirrel monkeys during hypogravity parabolic flight, no animals became motion sick, but over 80% of the same 11 animals became sick if they were unrestrained and maintained control of their posture.

Nancy G Daunton↗

Materials processing apparatus development for fluoride glass

Fluoride glasses have great potential for optical fiber communications due to the high transmittance when no microcrystallites occur during drawing operations. This work has developed apparatus to test the occurrence of microcrystallites during recrystallization in reduced gravity on the KC-135. The apparatus allows fluoride glass fiber, such as ZBLAN, to be melted and recrystallized during both the low and high g portions the parabolic flight.

Smith, Guy A.↗